• Title/Summary/Keyword: mm\

Search Result 35,969, Processing Time 0.058 seconds

Evaluation of Supplying Instream Flow by Operation Rule Curve for Heightening Irrigation Reservoir (이수관리곡선에 의한 증고저수지의 하천유지유량 공급 가능성 평가)

  • Lee, Jae-Nam;Noh, Jae-Kyoung
    • Korean Journal of Agricultural Science
    • /
    • v.37 no.3
    • /
    • pp.481-490
    • /
    • 2010
  • Baekgog reservoir is located in Jincheon county, Chungbuk province, of which full water levels will be heightened from EL. 100.1 m to EL. 102.1 m, and total storages from 21.75 $Mm^3$ to 26.67 $Mm^3$. The simulation for reservoir inflow was conducted by DAWAST model. The annual average irrigation water was estimated to 33.19 $Mm^3$ supplied to 2,975 ha and the instream flows could be allocated with 0.14 mm/d from October to April with annual average of 2.52 $Mm^3$. The operation rule curve was drawn using inflow, irrigation, and instream flow requirements data. The reservoir water storage was simulated on a daily basis in case of both normal and withdrawal limit operation. In case of normal operation, the annual average irrigation water supply increased from 31.95 $Mm^3$ to 33.32 $Mm^3$, the instream water supply from 2.40 $Mm^3$ to 2.44 $Mm^3$, the water storages from 15.74 $Mm^3$ to 19.88 $Mm^3$, and the water supply reliability from 77.3 % to 81.6 %. In case of operation with withdrawal limit, the amount of instream water supply was 2.52 $Mm^3$ from reservoir regardless of the condition while the water storage increased from 16.77 $Mm^3$ to 20.65 $Mm^3$. The irrigation water supply capacity was appropriate for the case of normal operation with 2 m heightened condition. The present instream water supply capacity was 35,000 $m^3$/d (6.86 $Mm^3$/y) while 42,000 $m^3$/d (8.36 $Mm^3$/y) in 2 m heightened condition in case of withdrawal limit operation.

Differences in retention of the reduction direction depending on dimensions and design CAD/CAM zirconia abutment for implant (Implant에 사용되는 CAD/CAM 전용 zirconia abutment의 표면적과 디자인에 따른 유지력 차이)

  • Nam, Taeg-Mo;Kim, Han-Gon;Kim, Byung-Sik;Lim, Si-Duk
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.317-325
    • /
    • 2010
  • Purpose: The aim of this study is to make some basic materials to find retention force difference based on the total height of CAD/CAM zirconia abutment used for implant, retention force difference based on how to regulate the height of the abutment, retention force difference based on the size and retention force difference based on the design group. Methods: The retention force was measured by being pulled at the speed of 1mm/min after being combined with zirconia block and abutment using Temp-BOND of Kerr. The experiment was done at the research lab of OSTEM in Busan by useing UNIVERSAL TESTING MACHINE on March 3rd, 2010. Results: After analysing the total height and the retention force, p-value had minor difference by 0.01 statistically. Namely, 3mm, 4mm, 5mm had the retention force difference and we could see retention force difference on 3mm and 5mm at the post test. After analyzing how to regulate the height and retention force, p-value had minor difference by 0.000 statistically. Namely, 1mm and 2mm had the retention difference and we could see that 1mm and 2mm with the total height had retention difference. After analyzing the retention force based on the size, p-value had minor retention force difference by 0.000 statistically. Namely, 7 different size had retention force difference and we could see the size 21.9mm, 32.9mm, 32.9mm, 38.4mm, 48.9mm and 54.9mm had retention force difference. Conclusion: Namely 9 different design group had retention difference and we could see that 9 design group with 5.6.7.8 design group and 9 design group with 1.2.3.4. design group had retention force.

Studies on drying rate, stress and defect with board thicknesses and drying schedules of Quercus grosseserrata B1. (물참나무 판재(板材)두께와 건조(乾燥)스케쥴별 건조(乾燥) 속도(速度), 응력과(應力)과 결함(缺陷)에 관(關)한 연구(硏究))

  • Lee, Sang-Jung;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.39-51
    • /
    • 1990
  • This research was carried out to offer the basis data for development of optimum drying schedule for a domestic oak species (Quercus grosseserrata B1.) by investigating drying rate. stress, defect, and moisuture gradient with board thicknesses and drying schedules (code number T4-C2 and T3-B1). The results were obtained as follows: 1. Average drying rate and total drying time from 52.2% to 5.8% were 0.105%/hr and 486 hours for drying schedule T4-C2 and those from 62.1% to 8.3% were 0.070%/hr. and 811 hours for drying schedule T3-B1. 2. Drying rates for 28mm- and 31mm-thick boards showed similar tendency, but were significantly different from 25mm- thick board in drying schedule T4-C2 and those for 22mm-, 25mm- 28mm- and 31mm-thick boards showed similar tendency but were significantly different from 19mm- thick boards in drying schedule T3-B1. 3. The moisture gradients for drying schedule T4-C2 were steeper than those for drying schedule T3-B1 during drying period. and especially in early drying stage slow slope of moisture gradients of drying schedule T3-B1 was effective in preventing serious problem of surface checks. 4. Drying stresses were lower in drying schedule T3-B1 than in drying schedule T4-C2 during drying period. 5. Drying schedule T4-C2 was appropriate for 25mm-thick board but not for 28mm- and 31mm-thick board because of strong drying condition. Drying schedule T3-B1 was appropriate for 28mm- and 31 mm-thick board but not for 19mm-, 22mm-, and 25mm-thick board because of weak drying condition.

  • PDF

A STUDY ON THE RANGE OF MANDIBULAR MOVEMENT OF NORMAL AND CLASS III MALOCCLUSION CHILDREN (정상교합과 III급 부정교합아동의 하악운동 범위에 대한 연구)

  • Jhee, In-Ae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.11 no.1
    • /
    • pp.41-56
    • /
    • 1984
  • The purpose of this study is to obtain the normal range of mandibular movement for 13 year old boys and girls, and to compare it to the range of mandibular movement of class III patient and normal adult for diagnosis and prognosis of class III malocclusion and TMJ dysfunction. The subjects were 20 normal boys 20 normal girls 22 class III boys and 18 class III girls. The author measured the ranges and shapes of movement of the mandible in the frontal, sagittal and horizontal trajectories using Saphon visitrainer C II (Tokyo Shizaisha Inc.) for the subjects. The results obtained are as follows: 1) The mean for maximum right laterotrusion in the frontal trajectory were 11.96mm in N.B., 11.10mm in N.G., 11.32mm in III. B., 11.24mm in III G. The mean for maximum left laterotrusion were 11.48mm, 11.0mm, 10.91mm, 10.44mm respectively, Area of border movement were 7.16cm in N.B., 6.59cm in N.G., 7.29cm in III. B., 7.50cm in III. G. 2) The mean for maximum protrusion in the sagittal trajectory were 11.7mm in N.B., 11.4mm in N.G.,11.87mm in III B., and 11.02mm in III. G. 3) The mean for maximum protrusion in the horizontal trajectory were 10.20mm in N.B.,10.00 mm in N.G., 9.12mm for III. B. and 9.36mm in III. G. 4) The mean for maximum protrusion of Class III subjects were shorter than those of normal subjects. 5) There was no sexual difference in the range of mandibular movement for 13 year old subjects. N.B; Normal boys N.G.; Normal girls III.B.; Class III boys III. G.; Class III girls.

  • PDF

A Study of the Intraocular Pressure of Korean Youth (한국인 청년의 안압 측정)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.91-97
    • /
    • 2006
  • The intraocular pressure for Korean youth were measured by using tonometer (AT555-Reichert). The relative frequency distributions of intraocular pressures have been studied for samples of 1,027 persons(475 males, 552 females). The most commonly recorded IOP for both men and women was around 14.5mmHg and 17.5mmHg, respectively. They were in the range of 7 to 23mmHg(males) and 7 to 22mmHg(females). The median pressure(cumulative frequency=0.5%) is 13.0~16.5mmHg for males and 16.5~18.5mmHg for females, so the values for females are slightly higher than males. The mean pressure is 15.2mmHg for males and 15.8mmHg for females, respectively. The 98% of population was in the range of the normal IOP. There are long-term diurnal variation in mean intraocular pressure and the IOP was decreased as a function of time from morning to night. The measured IOP was affected by several factors: exercise made to decrease the IOP and tight collars, dark places and posture of decubitus position got to elevate the IOP.

  • PDF

Measurements on Effects of Locations of Obstacles in an Explosion Chamber

  • Han, Jae-Beom;Lee, Young-Soon;Park, Dal-Jae
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.68-74
    • /
    • 2008
  • Measurements were performed to investigate the effects on flame and pressure development by varying locations of multiple obstacles in a top-venting explosion chamber. The chamber dimension was 1000 mm in height with a $700\;{\times}\;700\;mm^2$ cross-section and a rectangular vent area of $700\;{\times}\;700\;mm^2$. Three different multiple obstacles with blockage ratio of 30% were used by changing from 200 mm, 500 mm to 800 mm in heights within the chamber. Temporally resolved flame front images were recorded by a high speed camera to investigate the interaction between the propagating flame and the obstacles. The results showed that the triangular bar caused the fastest flame developments at given times whereas the lowest was obtained with the cylindrical bar. It was also found that local flame displacement speeds of different obstacles were sensitive to the locations of obstacles. The local speed becomes larger in going from 200 mm, to 500 mm and to 800 mm in heights. The obstacles in height of 800 mm yielded the highest overpressure whereas the lowest was in height of 200 mm.

  • PDF

Early Life History of Rhodeus Fish (R. uyekii and R. ocellatus) in the Nakdong River Water System

  • Park, Jae-Min;Han, Kyeong-Ho
    • Development and Reproduction
    • /
    • v.22 no.1
    • /
    • pp.39-53
    • /
    • 2018
  • The purpose of this study is to investigate the early life history of the Rhodeus fish, Rhodeus uyekii and R. ocellatus, in the Nakdong River to use as the preliminary data for the systematic study. The embryos used in the study were fertilized eggs (embryo) and larvae after artificial fertilization. The long diameter of the eggs of the R. uyekii was 3.39-3.97 mm (average $3.68{\pm}0.41mm$, n=30) and the short diameter was 1.36-1.55 mm (average $1.45{\pm}0.13mm$, n=30). The long diameter of the eggs of the R. ocellatus was 2.53-2.71 mm (average $2.62{\pm}0.12mm$, n=30) and the short diameter was 1.47-1.60 mm (average $1.53{\pm}0.09mm$, n=30). Hatching time was 48 hours for the R. uyekii and 50 hours for the R. ocellatus given that the average water temperature was $21.5^{\circ}C$. The hatched larvae were 4.95-5.00 mm (average $4.98{\pm}0.04mm$, n=5) for the R. uyekii and the total length was 3.66-3.69 mm (average $3.67{\pm}0.02mm$, n=5) for the R. ocellatus. R. uyekii was found to be 15.5-15.8 mm at total length (average $15.6{\pm}0.21mm$, n=5) on the 56 days after hatching with the number of dorsal fins being ⅲ-9, anal fins ⅲ-10, ventral fins ⅲ-5. The R. ocellatus was found to be 15.8-16.0 mm (average $15.9{\pm}0.14mm$, n=5) at total length on the 58 days with the number of dorsal fins being ⅲ-11, anal fins ⅲ-12 and ventral fins ⅲ-5 where the number of all fin stalks reached maximum.

Development of welding process to overcome misalignment in root pass at butt joint TIG welding of Stainless Steel (스테인리스강 TIG 맞대기 용접 루트 패스에서 단차 극복을 위한 공정 개발)

  • Im, Sung-Bin;Ham, Hyo-Sik;Ha, Jong-Moon;Seo, Ji-Suk;Cho, Sang-Myung
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.26-26
    • /
    • 2009
  • TIG 용접은 고품질이고 용접인자의 제어가 쉽고 정확하다는 장점이 있지만, 얕은 용입과 낮은 생산성과 같은 단점이 있다. TIG 오비탈 용접에서는 용입의 한계 때문에 작은 루트면과 넓은 그루브를 가공하여 다층 용접을 하며, 루트패스에서는 파이프 진원도에 의한 핏업 시 단차의 문제가 자주 발생하여 많은 현장에서 루트갭을 만들어 수동 용접하는 실정이다. 따라서 생산성이 낮으며 생산 단가가 높고 용접 품질이 작업자에 따라 다르게 된다. 이러한 문제점을 해결하여 자동 오비탈 용접을 위해 단차를 흡수 할 수 있는 용접 공정 개발이 필요하다. 본 연구의 목적은 TIG 용접에서 단차에 따른 용접성을 검토하여 이를 맞대기 용접에 적용했을 때 균일한 이면비드를 얻는 공정을 개발하는 것이다. 따라서 본 연구는 아래보기 자세에서 단차에 따른 용입 특성을 이면비드 및 단면으로 비교 분석하였다. 단차 없이 아크길이만 1mm, 2mm, 3mm로 변경하여 실험한 결과 아크길이가 짧아질수록 표면비드 폭은 좁아졌고 이면비드 폭은 증가하는 경향을 나타내어 아크길이가 짧아질수록 용융효율이 증가하는 것을 확인하였다. 단차 1mm에서 아크길이 3mm를 제외하고 표면비드 및 이면비드가 미려하였다. 하지만 단차 2mm에서는 아크길이 1mm, 2mm, 3mm 전부 이면비드가 생성되지 않았다. 이는 단차로 인해 아크길이가 증가하여 용융효율이 낮아졌기 때문이라 판단된다. 이면비드가 생성되지 못한 시험편을 백 베벨링(0.5mm, 1.0mm, 1.5mm, 2.0mm)하여 실험한 결과 단차 2mm, 아크길이 1-3mm 백 베벨링 2.0mm 적용한 시험편에서 양호한 이면비드를 얻을 수 있었다.

  • PDF

A Study on Fractal Monopole Antenna with Hexagonal Symmetrical Pattern (육각형 대칭 패턴 프랙탈 모노폴 안테나에 대한 연구)

  • Chang, Tae-Soon;Kang, Sang-Won
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.121-126
    • /
    • 2022
  • This study is about an antenna implemented in the form of a monopole having a hexagonal symmetric pattern by simplifying the modified Hilbert curve fractal monopole structure. The modified Hilbert curve fractal monopole structure was simplified and miniaturized, and the radiator was implemented in a hexagonal symmetrical pattern to improve performance. The dielectric constant of substrate is 4.7, and the total line length with a meander-shaped symmetrical structure is 59 mm. The size of the antenna is 10 mm × 10 mm × 0.8 mm, and the line width is 0.4 mm. The size of the antenna measuring jig is 64 mm × 21 mm × 1 mm. The resonant frequency is 1.57 GHz, and the frequency range is 1.51 to 1.615 GHz. The frequency bandwidth is 105 MHz. As for the antenna gain, the measurement gain of the YZ-plane was 2.32 dBi, and that of the XZ-plane was -1.03 dBi. As a result, we confirmed that antenna miniaturization is possible using a hexagonal symmetric pattern fractal structure. In addition, we confirmed that the antenna performance can be easily improved by changing the structure of the radiator.

The Benefit of KT-2000 Knee Ligament Arthrometer in Diagnosis of Anterior Cruciate Ligament Injury (슬관절 전방 십자 인대 파열의 진단에 있어서 KT-2000 기기의 유용성)

  • Park, Jai-Hyung;Kim, Hyoung-Soo;Jung, Kwang-Gyu;Yoo, Jeong-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.82-88
    • /
    • 2004
  • Purpose: In this study, we intended to ascertain the benefit of KT-2000 Knee arthrometer(KT-2000) in the diagnosis of ACL(Anterior cruciate ligament) injury by comparing the anterior displacement of normal knee with that of ACL deficient knee. Materials and Methods: We designated two examiners to measure the anterior displacement of the knee joint of 30 healthy individuals, using KT-2000, at 30$^{\circ}$ flexion setting of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation and analyzed these results according to the variables and measured the preoperative anterior displacement of the ACL injured knee in the 30 patients who have gone through an arthroscopic ACL reconstruction later. Results: The results of examiner 1 are 6.5${\pm}$1.5 mm, 2.5${\pm}$0.9 mm, 4.8${\pm}$1.2 mm, 6.4${\pm}$1.3 mm in right knee and 5.6${\pm}$1.3 mm, 2.1${\pm}$0.8 mm, 4.5${\pm}$1.2 mm, 5.2${\pm}$1.3 mm in left knee, in order of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation. The results of examiner 2 are 6.9${\pm}$1.2mm, 2.9${\pm}$1.1mm, 5.6${\pm}$1.6mm, 6.9${\pm}$1.5mm in right, 5.5${\pm}$1.7 mm,1.9${\pm}$0.9 mm, 5.1${\pm}$1.9 mm, 5.7${\pm}$1.6 mm in left knee, The side to side difference of examiner 1 in the setting of muscle relaxation is 0.9${\pm}$1.0 mm. The anterior displaement of ACL injured knee is average 11${\pm}$2.93 mm and difference of average 6.5${\pm}$2.31 mm form that of normal. In comparison between the right and left knees of healthy individuals, the both results of two examiners showed the statistical difference in the setting of muscle full relaxation but, the results showed the side to side difference below 2 mm in 25case(83%), 21case(70%) respectively and above 3 mm in just 1 case. In the comparison between the normal and ACL injured knees, the results show the statistical difference of the side to side difference in the setting of muscle relaxation(p<0.05). Conclusion: The KT-2000 result is affected by relaxation of muscles around knee, flexion angle of knee joint, rotation of tibia, the strength of displacing force, time of the test and physical factors as height and weight. However, the Accuracy of diagnosis of ACL injury by KT-2000 will increase if the examiner is skillful and the tests are made on the exact position of knee joint.

  • PDF