• Title/Summary/Keyword: mixtures

Search Result 4,732, Processing Time 0.032 seconds

Herbicidal efficacy of carfentrazone-ethyl mixtures in direct-seeding flooded rice (벼 담수직파에서 Carfentrazone-ethyl 혼합제의 제초활성)

  • Won, OK Jae;Park, Kee Woong;Park, Su Hyuk;Eom, Min Yong;Hwang, Ki Seon;Kim, Young Tae;Pyon, Jong Yeong
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • This study was conducted to evaluate the herbicidal efficacy of carfentrazone-ethyl mixtures in direct-seeding flooded rice. The efficacy of three different carfentrazone-ethly mixtures was greater than pyrazosulfuron-ethyl pyriminobac-methyl GR (PP GR). Weeding efficacy of three different carfentrazone-ethly mixtures was more than 96.9%. No phytotoxic effect was observed in the rice based on the plant height and the number of tillers. Yield of rice un three different carfentrazone-ethly mixtures application was more than both in the PP GR and in the hand weeding. Based on these data, three different carfentrazone-ethly mixtures can be applied to provide an effective weed management in direct-seeding flooded rice.

Surface Properties and Betergency of the Binary Surfactant Mixture (계면활성제 혼합용액의 계면특성 및 세척성에 관한 연구)

  • 심소희;박정희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.3
    • /
    • pp.632-640
    • /
    • 1997
  • Changes in surface properties and detergency of sunactant mixtures were investigated in order to study the optimum mixing ratio of anionic and nonionic surfactants by measuring surface tension, interfacial tension, suspendability, and emulsification as a Amction of mixing ratio. Also, surface tension and detergency of the surfactant mixtures were determined with the increase of water-hardness or temperature. The results were as follows: the addition of NPE to anionic surfactant solutions (LAS or SDS) by 0.1 mole fraction remarkably decreased surface tension. NPE (n=15)/anionic surfactant mixtures showed a synergistic effect in lowering interfacial tension and emulsification, but NPE (n=7.5)/anionic surfactant mixtures did not. In suspension stability, however, synergism appeared when LAS or 505 was mixed with both of NPE's. With respect to the hydrophile of NPE, NPE (n=15) was more effective than NPE (n=i.5) in improving suspension stability. Detergency of LAS/NPE mixture changed almost linearly with mixing ratio, but that of SDS/NPE mixture increased remarkably by the addition of 0.1 or 0.2 mole fraction of NPE at all temperatures. As the temperature increased, surface tension of surfactant mixtures decreased and detergency was improved, but their synergistic effect decreased. In hard water, the mixtures showed better detergency than single surfactuant solutions.

  • PDF

A Study on the Engineering Characteristics of PVA (Polyvinyl Alcohol) Fiber-Cement-Soil Mixtures (PVA 시멘트 혼합토의 공학적 특성 연구)

  • Kim, Young-Ik;Yeon, Kyu-Seok;Kim, Ki-Sung;Yoo, Kyeong-Wan;Kim, Yong-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.2
    • /
    • pp.35-43
    • /
    • 2011
  • This study aimed to investigate the engineering characteristics of PVA fiber-cement-soil mixture used to prevent or reduce brittle failure of cement-soil mixtures due to the tensile strength increase from the addition of a synthetic fiber. The engineering characteristics of PVA fiber-cement-soil mixtures composed of PVA fiber, soil, and a small amount of cement was analysed on the basis of the compaction test, the unconfined compression test, the tensile strength test, the freezing and thawing test, and the wetting and drying test. The specimens were manufactured with soil, cement and PVA fiber. The cement contents was 2, 4, 6, 8, and 10%, and the fiber contents was 0.4, 0.6, 0.8, and 1.0% by the weight of total dry soil. To investigate the strength characteristics depending on age, each specimen was manufactured after curing at constant temperature and humidity room for 3, 7 and 28 days, after which the engineering characteristics of PVA fiber-cement-soil mixtures were investigated using the unconfined compression test, the tensile strength test, the freezing and thawing test, and the wetting and drying test. The basic data were presented for the application of PVA fiber-cement-soil mixtures as construction materials.

Ecological Management of Turf Insects and Zoysia Large Patch by Mixing Turfgrass Species (잔디 혼식을 통한 생태학적 병충해 관리)

  • 박봉주
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.31 no.3
    • /
    • pp.107-113
    • /
    • 2003
  • Ecological control can contribute to the sustainibility of vegetation management systems by reducing the input currently derived from non-renewable fossil energy sources. The use of turfgrass mixtures is an important tool in turf management. Turfgrass mixtures of two or more compatible and adapted species provide improved tolerance to pest and environmental stress, more so than monostands. The objectives of this study were to evaluated turf insects, pests and zoysia large patch control by turgrass mixtures. In April 2001 and 2002, plots were inoculated with 50g of Rhizoctonia solani AG2-2LP inoculum. Inoculum were treated within a 29cm diamater circle at Zoysia japonica, Zoysia japonica, Poa pratenis, or Festuca arundinacea mixtures. After four weeks, disease severity in each plot was determined. plot area visual ratings were assessed visually on a linera 0 to 100%. In August 2001 and October 2002, turf insects and pests in each plot were investigated in 10cm deep soil cores with 8cm diameters using hole cut. Zoysia large patch affected zoysiagrass monostands more severly than zoysiagrass and cool-season turfgrasses mixtures. It was suggested that the barrier effect of cool-season turfgrass suppressed zoysia large patch in the mixture of zoysiagrass and cool-season turfgrasses. Also, warm-season and cool-season turfgrasses mixtures suppressed insect populations more efficiently than warm-season turfgrass monostands.

Breakdown Voltage and PD Characteristics of $SF_6/CF_4$ Mixtures in Nonuniform Field (불평등 전계에서 $SF_6/CF_4$ 혼합가스의 절연내력과 PD특성)

  • Hwang, Cheong-Ho;Sung, Heo-Gyung;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.635-640
    • /
    • 2008
  • New gas mixtures are now finding applications such as interrupting media for high-voltage circuit breakers. These mixtures consist of a high content of carbon tetrafluoride($CF_4$) added to sulfur hexafluoride($SF_6$). Nowdays $SF_6$ has been established for the use in gas insulated substations due to its high insulation withstand level and good arc quenching capability. At this paper Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltage and standard lightning impulse voltage(LI) was applied in a needle-plane electrodes. And partial discharge(PD) experiments were carried out in the test chamber which was made in needle-plane electrode. And ${\Phi}$-Q-N distribution of partial discharge signals was analyzed. The total pressure of the $SF_6/CF_4$ mixtures was varied within the range of 0.1-0.5 Mpa in the test chamber. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at positive impulse voltage and the PD inception voltage was increased slightly when pressure of $SF_6/CF_4$ Mixtures was increased. Maximum PD inception voltage is showed in 80% SF6/20%$CF_4$.

The Effect of Ions on Thermal Behaviors of Water in Poly(acrylic acid)/Water Mixtures (폴리아크릴산/$H_2O$ 혼합물에서 $H_2O$ 열적 거동에 미치는 이온의 영향)

  • Guan, Lan;Xu, Hongyan;Huang, Dinghai
    • Polymer(Korea)
    • /
    • v.34 no.4
    • /
    • pp.386-389
    • /
    • 2010
  • Thermal behaviors of water in the poly(acrylic acid) (PAA)/water mixtures with 0.1 M NaCl, HCl, and NaOH were investigated by DSC. It showed that adding ions in the mixtures affected the crystallization of water evidently. Compared with the PAA/water mixtures, the $T_m$ of freezable bound water in the mixtures with ions moved to lower values and varied with different cations and anions, due to the stabilization or destabilization of the hydrogen-bonding hydration between polymers and water molecules through ionic hydration. The content of non-freezable bound water in the non-crystalline phase of the PAA/water mixtures with ions was not constant, it increased with total water content gradually, owing to the more binding sites created by ions. The ions could change the distribution of different states of water in the polymer aqueous solutions evidently.

A flammability limit model for hydrogen-air-diluent mixtures based on heat transfer characteristics in flame propagation

  • Jeon, Joongoo;Choi, Wonjun;Kim, Sung Joong
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1749-1757
    • /
    • 2019
  • Predicting lower flammability limits (LFL) of hydrogen has become an ever-important task for safety of nuclear industry. While numerous experimental studies have been conducted, LFL results applicable for the harsh environment are still lack of information. Our aim is to develop a calculated non-adiabatic flame temperature (CNAFT) model to better predict LFL of hydrogen mixtures in nuclear power plant. The developed model is unique for incorporating radiative heat loss during flame propagation using the CNAFT coefficient derived through previous studies of flame propagation. Our new model is more consistent with the experimental results for various mixtures compared to the previous model, which relied on calculated adiabatic flame temperature (CAFT) to predict the LFL without any consideration of heat loss. Limitation of the previous model could be explained clearly based on the CNAFT coefficient magnitude. The prediction accuracy for hydrogen mixtures at elevated initial temperatures and high helium content was improved substantially. The model reliability was confirmed for $H_2-air$ mixtures up to $300^{\circ}C$ and $H_2-air-He$ mixtures up to 50 vol % helium concentration. Therefore, the CNAFT model developed based on radiation heat loss is expected as the practical method for predicting LFL in hydrogen risk analysis.

Strength and stiffness characteristics of cement paste-slime mixtures for embedded piles

  • Yong-Hoon Byun;Mi Jeong Seo;WooJin Han;Sang Yeob Kim;Jong-Sub Lee
    • Computers and Concrete
    • /
    • v.31 no.4
    • /
    • pp.359-370
    • /
    • 2023
  • Slime is produced by excavation during the installation of embedded piles, and it tends to mix with the cement paste injected into the pile shafts. The objective of this study is to investigate the strength and stiffness characteristics of cement pasteslime mixtures. Mixtures with different slime ratios are prepared and cured for 28 days. Uniaxial compression tests and elastic wave measurements are conducted to obtain the static and dynamic properties, respectively. The uniaxial compressive strengths and static elastic moduli of the mixtures are evaluated according to the curing period, slime ratio, and water-cement ratio. In addition, dynamic properties, e.g., the constrained, shear, and elastic moduli, are estimated from the compressional and shear wave velocities. The experimental results show that the static and dynamic properties increase under an increase in the curing period but decrease under an increase in the slime and water-cement ratios. The cement paste-slime mixtures show several exponential relationships between their static and dynamic properties, depending on the slime ratio. The bearing mechanisms of embedded piles can be better understood by examining the strength and stiffness characteristics of cement paste-slime mixtures.

AC Breakdown Characteristics of $Ar/N_2 and Kr/N_2$Gas Mixtures ($Ar/N_2 및 Kr/N_2$혼합가스의 교류절연파괴 특성)

  • Lee, Sang-Woo;Kim, In-Sik;Lee, Dong-In;Lee, Kwang-Sik;Kim, Lee-Kook
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.12
    • /
    • pp.599-606
    • /
    • 2001
  • In this paper, the ac breakdown characteristics of pure Ar, Kr and $N_2$ gas with gas pressure range of 58.8-137.3[kPa] under uniform and non-uniform fields were investigated, and the measured values were compared with those In Ar/$N_2$ and Kr/$N_2$ gas mixtures with pressure varying. Summarizing the experimental results, the breakdown voltages of Pure $N_2$gas, under uniform and non-uniform fields, were increased about 4.8 and 1.1 times than those of pure Ar gas, and about 4.4 and 1.2 times than those of pure Kr gas, and the ac breakdown voltage increased with the pressure increasing. The breakdown voltages of Ar/$N_2$ gas mixtures were decreased with decreasing the mixture ratio of Pure $N_2$ gas. In case of Ar(85%)/$N_2$ (15%) and Ar(70%)/$N_2$ (30%) gas mixtures comparing to the pure Ar gas, the breakdown voltages under uniform field were increased about 1.8 and 2.2 times, and under non-uniform field were increased about 1.1 and 1.3 times at the pressure of 101.3[kPa]. Also, in case of Kr(85%)/$N_2$ (15%) and Kr(70%)/$N_2$ (30%) gas mixtures comparing to the pure Kr gas, the breakdown voltages under uniform field were increased about 1.7 and 2.0 times, and under non-uniform field were increased about 1.0 and 1.2 times. Corona inception voltage of Kr(70%)/$N_2$(30%) gas mixtures under non-uniform fields were increased about 1.28 times than those of Ar(70%)/$N_2$ (30%) gas mixtures. In case of practical incandescent lamps, luminous and lifetime of Kr(70%)/$N_2$ (30%) gas mixtures were increased about 1.15 and 1.21 times than those of Ar(70%)/$N_2$ (30%) gas mixtures.

  • PDF

Transformation Characteristics of Chlorinated Aliphatic Hydrocarbon (CAH) Mixtures in a Two-Stage Column: 1st Chemical Column Packed with Zinc Natural Ore and 2nd Biological Column Stimulated with Propane-Oxidizing Microorganisms (아연 광석과 프로판산화 미생물을 이용한 이단 고정상 반응기에서의 염소계 지방족 탄화수소 혼합물 분해 특성)

  • Son, Bong-han;Kim, Nam-hee;Hong, Kwang-pyo;Yun, Jun-ki;Lee, Chae-young;Kwon, Soo-youl;Kim, Young
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.723-730
    • /
    • 2007
  • This study was conducted to develop a combined method for remediating a Chlorinated Aliphatic Hydrocarbons (CAHs) mixtures-contaminated aquifer. The process is consist of two processes. A chemical process (1st) using natural zinc ores for reducing higher concentrations of CAH mixtures to the level at which biological process is feasible; and A biological process (2nd) using aerobic cometabolism for treating lower concentration of CAH mixtures (less than 1 mg/L). Natural zinc ore showed relatively high transformation capacity, average dehalogenation percentage, and the best economic efficiency in previously our study. To evaluate the feasibility of the process, we operated two columns in series (that is, chemical and biological columns). In the first column filled with natural zinc ore and sand, CAH mixtures were effectively transformed with more than 95% efficiency, the efficiency depends on the Empty Bed Contact Time (EBCT) and the mass of zinc ore packed. Scanning Electron Microscope (SEM), X-Ray Diffraction (XRD) analysis were performed to make sure whether natural zinc ore played an key role in the dechlorination of the CAH mixtures. The characteristics of zinc metal surface changed after exposure to CAHs due to oxidation of $Zn^0$ to $Zn^{2+}$. In the biological column injecting propane, DO and effluent of the chemical column, only 1,1,1-TCA was cometabolically transformed. Consequently, the combined process would be effective to remediate an aquifer contaminated with high concentrations of CAH mixtures.