• 제목/요약/키워드: mixture refrigerant

검색결과 148건 처리시간 0.029초

2중 관형 열교환기내 비공비혼합냉매 R-22+R134a의 응축열전달 특성에 관한 연구 (Condensation Heat Transfer Characteristics of Non-Azeotropic Refrigerant Mixture(NARMs) Inside Double Pipe Heat Exchangers)

  • 노건상;오후규;권옥배
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권3호
    • /
    • pp.91-100
    • /
    • 1996
  • Experimental results for forced convection condensation of non-azeotropic refrigerant mixtures inside a horizontal smooth tube are presented. The mixtures of R-22+R-134a and pure refrigerants R-22 and R-134a are used as the test fluids and a double pipe heat exchanger of 7.5mm ID and 4800mm long inside tube is used. The range of parameters are 100-300kg/h of mass flow rate, 0-1.0 of quality, and 0, 33, 50, 67, and 100 weight percent of R-22 mass fraction in the mixtures. The heat flux, vapor pressure, vapor temperature and tube wall temperature were measured. Using the data, the local and average heat transfer coefficients for the condensation have been obtained. In the same given experimental conditions, the liquid heat transfer coefficients for NARMs were considerally lower than that of the pure refrigerant of R-22 and R-134a. Local heat transfer characteristics for NARMs were different from pure refrigerant R-22 and R-134a. In some regions, local heat transfer coefficients for NARMs were increased in the following order ; Bottom$\rightarrow$Top$\rightarrow$Side. The condensation heat transfer coefficients for NARMs increased with mass velocity, heat flux, and quality, but were considerably lower than that of pure refigerant R-22 and R-134a.

  • PDF

A STUDY ON THE EXPLOSION SAFETY ASSESSMENT OF HYDROCARBON REFRIGERANT REFRIGERATOR

  • Oh, Kyu-Hyung;Kim, Min-Kyu;Chu, Euy-Sung;Lim, Byung-Han;Kim, Man-Hoe;Park, Yoon-Ser
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.289-296
    • /
    • 1997
  • This paper discribes an experimental explosion risk assessment study on refrigerators containing flammable hydrocarbon refrigerant. A refrigerator used in this study is a larder fridge type, 215 liter in volume. The hydrocarbon refrigerant used in the refrigerator is iso-butane(C$_4$H$_{10}$). For the explosion safety assessment of the refrigerator, temperature of compressor, cooling air circulation fan motor, defrost heater and inner lamp were measured during the operation. And to confirm the ignitablity of flammable gas by the electric spark of the switches of the refrigerator, ON-OFF test of all switches were conducted with compulsorily near the stoichiometric concentration atmosphere of iso-butane-air mixture. As the result of experiment above mentioned and another experiment for the explosion safety assessment, we can conclude that explosion hazard in connection with the use of hydrocarbon refrigerant was few.w.

  • PDF

Miniature J-T cryocooler using argon and nitrous oxide mixture

  • Hwang, Gyu-Wan;Jeong, Sang-Kwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권4호
    • /
    • pp.38-42
    • /
    • 2008
  • Miniature J-T cryocooler using nitrogen or argon has been widely adopted in cooling infrared sensor for space/military application and cryosurgery. Argon or nitrogen, however, has relatively low specific cooling power compared to nitrous oxide, but the ultimate operating temperature is much lower than nitrous oxide. On the other hand, nitrous oxide has large specific cooling power, but the operating temperature is limited to its boiling point (>183K). To compromise the different characteristics of these gases, the performance of miniature J-T cryocooler using argon and nitrous oxide mixture is investigated in this paper. Three different compositions of mixture (25/75, 50/50, and 75/25 molar fraction) are blended and tested. The results are compared with the experiments of pure argon and pure nitrous oxide. The experimental results show some encouraging potentiality of mixed refrigerant J-T cryocooler. The critical clogging problem, however, was observed with argon and nitrous oxide mixture, and the lowest achievable temperature with this mixture was limited to the freezing point of nitrous oxide. The paper discusses detailed clogging process of the mixture and suggests an alternative.

CO2 압축기의 운전조건과 오일토출의 상관분석에 관한 실험적 연구 (An Experimental Study on Correlation between Oil Discharge and Various Operating Conditions of a CO2 Compressor)

  • 이익수;강병하
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.73-79
    • /
    • 2011
  • A portion of oil for lubrication of compressor flows together with refrigerant in the refrigeration system. If the oil discharge from a compressor is increased in the refrigeration system, not only pressure drop is increased in other components, such as evaporator and gas cooler, but also heat transfer coefficient in the heat exchangers is decreased. Oil discharge rate from a compressor may strongly depend on operating conditions of a compressor. In this study, one stage single rotary compressor is employed for measuring oil circulation ratio(OCR). Carbon dioxide and PAG oil are used as refrigerant and lubricant. Using a U-tube densimeter, mixture density is measured. Oil circulation ratio(OCR) can be estimated by measured mixture density. The results obtained indicate that the oil circulation ratio(OCR) is increased as the suction temperature or compressor operating frequency is increased. Oil circulation ratio(OCR) correlation of the compressor is also suggested.

평활관 내 R32/290 혼합냉매의 증발열전달 특성에 관한 실험적 연구 (Experimental studies on the evaporative heat transfer of R32/290 mixtures in a horizontal smooth tube)

  • 조진민;김주혁;윤석호;김민수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.268-273
    • /
    • 2005
  • Because of environmental issues caused by CFC, HCFC or HFC refrigerants, new alternative refrigerants has gained a significant attention. This paper presents experimental information on heat transfer coefficient and pressure drop behavior during evaporation process of R32/290 mixtures in a horizontal smooth tube. A smooth tube with outer diameter of 5 mm and length of 5 m was selected as a test tube. Heat transfer coefficients and pressure drop characteristics were measured for a range of mass fluxes from 497 to 994 $kg/m^2s$, heat fluxes from 12 to 20 $kW/m^2$ and for several mixture compositions(100/0, 75/25, 58.4/41.6, 2s/75, 100/0 by wt% of R32/290). The differences of measured heat transfer characteristics among various R32/290 refrigerant mixtures were analyzed for various compositions.

  • PDF

생활공간 냉난방용 열펌프의 성능개선을 위한 새로운 혼합냉매(RM-1) 개발 (Development of a New Refrigerant Mixture (RM-1) to improve the performance of Heat Pump System for Heating and Cooling of the Living Space)

  • 송헌;노정근
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.67-76
    • /
    • 2011
  • 생활공간 냉난방용 열펌프의 성능향상을 위해 R22의 대체 냉매로서 새로운 혼합냉매R22/R23/R152a(RM-1)을 개발하고 U. S. A.의 NIST사의 REFPRO Pprogram을 이용해 이 혼합냉매의 P-h diagram을 구성하여 실용화에 이용할 수 있도록 하였다. 본 연구는 실험을 통해 R22와 RM-1의 열펌프 성능효과를 분석하였다. 입 출구 물의 온도와 제2의 전열매체로서 물의 질량유량, 압축기의 소요 에너지 그리고 열펌프의 기타 열적 특성을 다양한 조건하에서 측정하였다. 이 실험 데이터를 통해 공기-물 열펌프 시스템에서의 RM-1과 R22의 성능계수(COP)를 비교하였다. 이를 통해, 혼합냉매 RM-1을 사용하는 열펌프 시스템은 외기온 $-17^{\circ}C$에서도 2.2의 성능계수로 작동하는 결과를 본 연구에서 보여주었다.

Forced Convective Boiling of Refrigerant-Oil Mixtures in a Bundle of Enhanced Tubes Having Pores and Connecting Gaps

  • Park, Ji-Hoon;Kim, Nae-Hyun;Kim, Do-Young;Byun, Ho-Won;Choi, Yong-Min;Kim, Soo-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권3호
    • /
    • pp.81-87
    • /
    • 2009
  • The effect of oil on convective boiling of R-123 in an enhanced tube bundle is experimentally investigated at $26.7^{\circ}C$ saturation temperature. The enhanced tube had pores (0.23 mm diameter) and connecting gaps (0.07 mm width), which had been optimized using pure R-123. The effects of oil concentration (0 to 5%), heat flux (10 to $40\;kW/m^2$), mass velocity (8 to $26\;kg/m2^s$) and vapor quality are investigated. The oil significantly reduces the bundle boiling heat transfer coefficient. With 1% oil, the reduction is approximately 35%. Further addition of oil further reduces the heat transfer coefficient. The data are also compared with the pool boiling counterpart. The reduction in the heat transfer coefficient is smaller in a bundle (convective boiling) than in a pool (single-tube pool boiling), with larger difference at a smaller heat flux. Similar to pure R-123 case, the effects of mass velocity and vapor quality are negligible for the convective boiling of R-123/oil mixture.

혼합냉매의 환상 유동 증발열전달 해석 (Analysis of Convective Boiling Heat Transfer for Refrigerant Mixtures in Annular Horizontal Flow)

  • 신지영;김민수
    • 대한기계학회논문집B
    • /
    • 제20권2호
    • /
    • pp.720-729
    • /
    • 1996
  • An analysis of convective boiling heat transfer for refrigerant mixtures is performed for an annular flow to investigate the degradation of the heat transfer rate. Annular flow is selected in this study because a great portion of the evaporator in the refrigeration and air conditioning system is known to be in the annular flow regime. Mass transfer effect due to composition difference between liquid and vapor is included in this analysis, which is considered to be one of driving forces for the mass transfer at the interface. Due to the concentration gradient at the interface the mass transfer is interfered, so is the evaporative heat transfer at the interface. The mass transfer resistance makes the interface temperature slightly higher and, as a result, the heat transfer coefficients decrease compared with those without mass transfer effects. The degradatioin of the heat transfer rate reaches its maximum at a certain composition. The composition difference between vapor core and vapor at the interface has a direct effect on the temperature difference between the vapor core and the interface and the degradation of the heat transfer rate. Correction factor $C_{F}$ for the mixture effects is added to the correlation for pure substances and the flow boiling heat transfer coefficients can be calculated using the modified equation.n.

R435A를 적용한 정수기 냉동시스템의 성능평가 (Performance Evaluation of R435A on Refrigeration System of Water Purifiers)

  • 이요한;강동규;최현주;정동수
    • 한국태양에너지학회 논문집
    • /
    • 제33권1호
    • /
    • pp.15-23
    • /
    • 2013
  • In this study, thermodynamic performance of R435A is examined both numerically and experimentally in an effort to replace HFC134a used in the refrigeration system of domestic water purifiers. Even though HFC134a is used predominantly in such a system these days, it needs to be phased out in the near future in Europe and most of the developed countries due to its high global warming potential. To solve this problem, cycle simulation and experimental measurements are carried out with a new refrigerant mixture of 20%R152a/80%RE170 using actual domestic water purifiers. This mixture is numbered and listed as R435A by ASHRAE recently. Test results show that the system performance with R435A is greatly influenced by the amount of charge due to the small internal volume of the refrigeration system of the domestic water purifiers. With the optimum amount of charge of 21 to 22 grams, about 50% of HFC134a, the energy consumption of R435A is 11.8% lower than that of HFC134a. The compressor discharge temperature of R435A $8^{\circ}C$ lower than that of HFC134a at the optimum charge. Overall, R435A, a new long term environmentally safe refrigerant, is a good alternative for HFC134a requiring little change in the refrigeration system of the domestic water purifiers.