• Title/Summary/Keyword: mixing gases

Search Result 152, Processing Time 0.023 seconds

A Study on the Dynamic Characteristics of Nitrogen Mixed Gas for Thermostatic Expansion Valve Sensing Blub (온도 감지식 팽창밸브 감온통 질소가스 혼합냉매의 동특성 연구)

  • Kim, Si-Young;Koo, Su-Jin;Ju, Chang-Sik
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.69-75
    • /
    • 2014
  • The pressure and temperature characteristics of mixed refrigerant gases in bulb for thermostatic expansion valve were studied using R22 refrigerant and $N_2$ gases. The characteristics of mixed refrigerant gases were investigated according to pressure variation and the variation of composition ratio of R22 refrigerant and $N_2$ gases in the temperature range of -$15^{\circ}C$~$15^{\circ}C$. The Maximum operating pressure(MOP) of mixed refrigerant gases were showed a tendency to decrease with decreasing the mixing ratio of $N_2$ gas. The characteristics in the case of the mixing ratio of 90:1 for R22 refrigerant and $N_2$ gases were the same result as Reference refrigerant. In addition, the characteristics of the mixed refrigerant gases in the mixing ratio of 90:1 for R22 refrigerant and $N_2$ gases were showed almost linear in the measurement range of pressure-temperature, and the physical properties also were showed similar results with Reference refrigerant. It was able to confirm that a MOP on the thermostatic expansion valve for sensing bulb can be maintained by adjusting the mixing ratio of R22 refrigerant and $N_2$ gases.

A Study on the Additives of mixed Gas charged in Thermostatic Bulb for Expansion Valve (팽창밸브 개폐용 감온통 혼합가스의 첨가제 연구)

  • Kim, Si-Young;Ju, Chang-Sik;Koo, Su-Jin
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.126-132
    • /
    • 2014
  • The P-T characteristics of mixed refrigerant in thermostatic expansion valve sensing bulb were studied using R-134a and R-410A refrigerant. The characteristics of mixed refrigerant were investigated according to pressure variation and the variation of composition ratio of R-134A and R-410A in the temperature range of $-15^{\circ}C{\sim}15^{\circ}C$. The Thermodynamic characteristic values of the mixed refrigerants were identified using the characteristic value analysis program of mixed refrigerant(Refrop v9.0, NIST). The P-T characteristics in the case of the mixing ratio of 90:10 for R-410A and R-134A were the same result as R-22. And the physical properties showed similar results with R-22. The Maximum operating pressure(MOP) of mixed refrigerant showed a tendency to decrease with decreasing the mixing ratio of additive gases($N_2$ or He) gases. The characteristics in the case of the mixing ratio of 80:1 for mixed refrigerant and additive gases were the similar result as Reference refrigerant.(R-22 MOP, Sporlan company) In addition $N_2$ and He, both showed the same results. It was able to confirm that a MOP on the thermostatic expansion valve sensing bulb can be maintained by adjusting the mixing ratio of mixed refrigerant gases and additive gases.

The Characteristics on Arc Pressure Distribution of TIG Welding with Shield Gas Mixing Ratio (TIG 용접에서의 실드 가스 혼합비에 따른 아크 압력분포 특성)

  • Oh Dong-Soo;Kim Yeong-Sik;Cho Sang-Myung
    • Journal of Welding and Joining
    • /
    • v.23 no.1
    • /
    • pp.41-47
    • /
    • 2005
  • Arc pressure is one of important factors in understanding physical arc phenomena. Especially it affects on the penetration, size and shape of TIG welding. Some researches were reported on the effect of arc pressure in low and middle current region. But there are not any research in high current region. The purpose of this study is to investigate the arc pressure distribution with mixing ratio of shield gas such as Ar and He gases. A Cu block with water cooling was specifically designed and used as an anode electrode in order to measure the arc pressure in high current region. Then, the arc pressure distribution was measured with change in welding current and mixing ratio of shield gases. The arc force was obtained by numerically integrating the measured results. As the results, it was shown that the arc pressure was concentrated at the central part of the arc in middle and high current regions when a pure Ar gas was used. In case of Ar + He mixing gas, the arc pressure was much lower than that of pure Ar gas. In addition, it was widely distributed to radial direction.

Numerical Studies of Cloud Acidification Processes Using a One Dimensional Cumulus Cloud Model (일차원 적운모델을 이용한 산성강우 형성에 관한 수치적 연구)

  • 곽노혁;안상욱;홍민선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.3
    • /
    • pp.145-149
    • /
    • 1991
  • A one dimensiional cumulus cloud model has been developed for the investigation of temporal and altitudinal variation of trace gases and the wet deposition rates of sulfate for different simulation conditions. The results show that the dynamic field, liquid mixing ratios and the solubility of trace gases affect the distribution of trace gases and the droplet pH. Temporal variation of the predicted surface precipitation and sulfate deposition rates agree well with the field data.

  • PDF

Removal Effect of Acid Gases by Reactant Mixer and Distributor of Bag Filter in Dry Scrubbing with NaHCO3 (중탄산나트륨 건식공정에서 반응제 혼합 장치 및 백필터 분배장치에 의한 산성가스 제거 영향)

  • Lee, Young-Man;Kwak, Yeon-Ho;Bae, Woo-Keun;Kwon, Ki-Wook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.402-409
    • /
    • 2009
  • Sodium bicarbonate ($NaHCO_3$) was used as a reactant for the removal of acid gases from a waste incinerator. The removal efficiencies of HCl and $SO_x$ were tested with a reactant mixing apparatus and a distributor installed at the bag filter inlet. It was shown that the stoichiometric ratio of $NaHCO_3$ to the acid gases which allows a removal of over 90% for both HCl and $SO_2$ was about 1.2. When a reactant mixing apparatus was installed on the duct, the removal efficiencies of HCl and $SO_2$ at the end of the duct were increased by approximately 1.5 and 3 times respectively, compared to when the apparatus was not installed. At the end of the bag filter, the removal efficiencies of the both were as high as 98% with a stoichiometric ratio of 1.35. Installing a reactant mixing apparatus on the duct and a distributor at the entrance of the bag filter and using $NaHCO_3$ as a reactant helped overcome the problem of low removal efficiencies of acid gases by dry scrubbing.

The Analysis of DC Plasmas Characteristics on SFSF6 and N2 Mixture Gases (SF6/N2 혼합기체의 DC 플라즈마 특성 분석)

  • So, Soon-Youl
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1485-1490
    • /
    • 2014
  • $SF_6$ gas has been used for power transformers or gas insulated switchgears, because it has the superior insulation property and the stable structure chemically. It has been, however, one of global warming gases and required to reduce the its amount. Some papers have reported that its amount could be reduced by mixing with other gases, such as $N_2$, $CF_4$, $CO_2$ and $C_4F_8$ and their mixture gases would cause the synergy effect. In this paper, we investigated the characteristics of DC plasmas on $SF_6$ mixture gases with $N_2$ at atmospheric pressure. $N_2$ gas is one of cheap gases and has been reported to show the synergy effect with mixing $SF_6$ gas, even though $N_2$ plasmas have electron-positive characteristics. 38 kinds of $SF_6/N_2$ plasma particles, which consisted of an electron, two positive ions, five negative ions, 30 excitation and vibration particles, were considered in a one dimensional fluid simulation model with capacitively coupled plasma chamber. The results showed that the joule heating of $SF_6/N_2$ plasmas was mainly caused by positive ions, on the other hand electrons acted on holding the $SF_6/N_2$ plasmas stably. The joule heating was strongly generated near the electrodes, which caused the increase of neutral gas temperature within the chamber. The more $N_2$ mixed-ratio increased, the less joule heating was. And the power consumptions by electron and positive ions increased with the increase of $N_2$ mixed-ratio.

The Effect of Nonrandom Distribution of Molecules on the Equation of State for Gases (분자의 논랜덤 분포가 기체의 상태방정식에 미치는 영향)

  • Jung, Hae-Young
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.5
    • /
    • pp.540-546
    • /
    • 2013
  • Using the free volume of van der Waals equation, Carnahan-Starling equation for hard spheres, Wilson equation for nonrandom mixing of solution, NRTL equation and our equation, several new equations of states for pure gases are derived. Using these equations, compressibility factors for pure gases are calculated and compared with Nelson-Obert generalized compressibility factor charts. The equation of states using the concept of molecular nonrandom distribution gave better results than those of molecular random distribution. This shows that the molecular nonrandom distribution makes considerable effect on the equation of states.

EFFECT OF VALVE TIMING AND LIFT ON FLOW AND MIXING CHARACTERISTICS OF A CAI ENGINE

  • Kim, J.N.;Kim, H.Y.;Yoon, S.S.;Sa, S.D.;Kim, W.T.
    • International Journal of Automotive Technology
    • /
    • v.8 no.6
    • /
    • pp.687-696
    • /
    • 2007
  • To increase the reliability of auto-ignition in CAI engines, the thermodynamic properties of intake flow is often controlled using recycled exhaust gases, called internal EGR. Because of the internal EGR influence on the overall thermodynamic properties and mixing quality of the gases that affect the subsequent combustion behavior, optimizing the intake and exhaust valve timing for the EGR is important to achieve the reliable auto-ignition and high thermal efficiency. In the present study, fully 3D numerical simulations were carried out to predict the mixing characteristics and flow field inside the cylinder as a function of valve timing. The 3D unsteady Eulerian-Lagrangian two-phase model was used to account for the interaction between the intake air and remaining internal EGR during the under-lap operation while varying three major parameters: the intake valve(IV) and exhaust valve(EV) timings and intake valve lift(IVL). Computational results showed that the largest EVC retardation, as in A6, yielded the optimal mixing of both EGR and fuel. The IV timing had little effect on the mixing quality. However, the IV timing variation caused backflow from the cylinder to the intake port. With respect to reduction of heat loss due to backflow, the case in B6 was considered to present the optimal operating condition. With the variation of the intake valve lift, the A1 case yielded the minimum amount of backflow. The best mixing was delivered when the lift height was at a minimum of 2 mm.

A Study on Etching of Platinum Thin Film in ICP Using Ar/HBr/$Cl_2$ Gases (ICP를 이용한 Ar/HBr/$Cl_2$ 가스에서 백금 박막의 식각 연구)

  • Kim, Nam-Hoon;Kim, Chang-Il;Kwon, Kwang-Ho;Chang, Eui-Goo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1294-1296
    • /
    • 1998
  • Platinum thin films which hardly form volatile compounds with any reactive gas at normal process temperature was etched in Inductively Coupled Plasma (ICP) using Ar/HBr/$Cl_2$ gases. It is observed that the etch rate of platinum is reduced as increasing of HBr/$Cl_2$ gas mixing ratio when Ar gas ratio is fixed. However, we obtain good etching profile of platinum films without unwanted residues in 90% Ar/5% HBr/5% $Cl_2$ gas mixing ratio.

  • PDF

Development of a Noble Gas Isotope Dilution Mass Spectrometric System Combined with a Cryogenic Cold Trap (초저온 냉각 트랩을 결합한 비활성기체 동위원소 희석 질량분석 시스템의 제작)

  • HONG, BONGJAE;SHIN, DONGYOUB;PARK, KEYHONG;HAHM, DOSHIK
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.27 no.3
    • /
    • pp.144-157
    • /
    • 2022
  • Noble gases, which are chemically inert and behave conservatively in marine environments, have been used as tracers of physical processes such as air-sea gas exchange, mixing of water masses, and distribution of glacial meltwater in the ocean. For precise measurements of Ne, Ar, and Kr, we developed a mass spectrometric system consisting of a quadrupole mass spectrometer (QMS), a high vacuum preparation line, an activated charcoal cryogenic trap (ACC), and a set of isotope standard gases. The high vacuum line consists of three sections: (1) a sample extraction section that extracts the dissolved gases in the sample and mixes them with the standard gases, (2) a gas preparation section that removes reactive gases using getters and separates the noble gases according to their evaporation points with the ACC, and (3) a gas analysis section that measures concentrations of each noble gas. The ACC attached to the gas preparation section markedly lowered the partial pressures of Ar and CO2 in the QMS, which resulted in a reduced uncertainty of Ne isotope analysis. The isotope standard gases were prepared by mixing 22Ne, 36Ar, and 86Kr. The amounts of each element in the mixed standard gases were determined by the reverse isotope dilution method with repeated measurements of the atmosphere. The analytical system achieved precisions for Ne, Ar, and Kr concentrations of 0.7%, 0.7%, and 0.4%, respectively. The accuracies confirmed by the analyses of air-equilibrated water were 0.5%, 1.0%, and 1.7% for Ne, Ar, and Kr, respectively.