• Title/Summary/Keyword: mixed-use building

Search Result 233, Processing Time 0.027 seconds

Flame Retardant Properties of Polymer Cement Mortar Mixed with Light-weight Materials for 3D Printing (3D 프린팅용 경량재료 혼입 폴리머 시멘트 모르타르의 난연특성)

  • Son, Bae-Geun;Song, Hun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.330-337
    • /
    • 2021
  • 3D printing is not only at the fundamental study and small-scale level, but has recently been producing buildings that can be inhabited by people. Buildings require a lot of cost and labor to work on the form work, but if 3D printing is applied to the building, the construction industry is received attention from technologies using 3D printing as it can reduce the construction period and cost. 3D printing technology for buildings can be divided into structural and non-structural materials, of which 3D printing is applied to non-structural materials. Because 3D printing needs to be additive manufacturing, control such as curing speed and workability is needed. Since cement mortar has a large shrinkage due to evaporation of water, cement polymer dispersion is used to improve the hardening speed, workability, and adhesion strength. The addition of polymer dispersion to cement mortar improves the tensile strength and brittleness between the cement hydrate and the polymer film. Cement mortar using polymer materials can be additive manufacturing but it has limited height that can be additive manufacturing due to its high density. When light-weight materials are mixed with polymer cement mortar, the density of polymer cement mortar is lowered and the height of additive manufacturing, so it is essential to use light-weight materials. However, the use of EVA redispersible polymer powder and light-weight materials, additional damage such as cracks in cement mortar can occur at high temperatures such as fires. This study produced a test specimen incorporating light-weight materials and EVA redispersible polymer powder to produce exterior building materials using 3D printing, and examined flame resistance performance through water absorption rate, length change rate, and cone calorimeter test and non-flammable test. From the test result, the test specimen using silica sand and light-weight aggregate showed good flame resistance performance, and if the EVA redispersible polymer powder is applied below 5%, it shows good flame resistance performance.

Systematizing Information Use to Address Determinants of Health Worker Health in South Africa: A Cross-sectional Mixed Method Study

  • Muzimkhulu Zungu;Annalee Yassi ;Jonathan Ramodike;Kuku Voyi;Karen Lockhart;David Jones;Spo Kgalamono;Nkululeko Thunzi;Jerry Spiegel
    • Safety and Health at Work
    • /
    • v.14 no.4
    • /
    • pp.368-374
    • /
    • 2023
  • Background: Recognizing that access to safe and healthy working conditions is a human right, the World Health Organization (WHO) calls for specific occupational safety and health (OSH) programs for health workers (HWs). The WHO health systems' building blocks, and the International Labour Organization (ILO), highlight the importance of information as part of effective systems. This study examined how OSH stakeholders access, use, and value an occupational health information system (OHIS). Methods: A cross-sectional survey of OSH stakeholders was conducted as part of a larger quasi experimental study in four teaching hospitals. The study hospitals and participants were purposefully selected and data collected using a modified questionnaire with both closed and open-ended questions. Quantitative analysis was conducted and themes identified for qualitative analysis. Ethics approval was provided by the University of Pretoria and University of British Columbia. Results: There were 71 participants comprised of hospital managers, health and safety representatives, trade unions representatives and OSH professionals. At least 42% reported poor accessibility and poor timeliness of OHIS for decision-making. Only 50% had access to computers and 27% reported poor computer skills. When existing, OHIS was poorly organized and needed upgrades, with 85% reporting the need for significant reforms. Only 45% reported use of OHIS for decision-making in their OSH role. Conclusion: Given the gap in access and utilization of information needed to protect worker's rights to a safe and healthy workplace, more attention is warranted to OHIS development and use as well as education and training in South Africa and beyond.

A Case Study on Urban Regeneration Projects for Declined Industrial Districts in Downtown Area (도심 노후산업지구 도시재생사업 사례연구)

  • Choi, Kang-Rim
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.10
    • /
    • pp.129-142
    • /
    • 2019
  • It is needed to regenerate declined industrial districts in downtown area through to invite new industry and to improve urban environment. The purpose of this paper was to make suggestions on the urban regeneration for the districts. I have taken a literature research and a site analysis with cases of 'the South Lake Union' in Seattle and 'Pearl District' in Portland, USA. The result of the analysis was as follows: (1) The land use was changed to mixed use of business-commerce-recreation. The building use was changed to facilities for work, play and live. (2) Infrastructures were improved for user oriented facilities such as pedestrian friendly street, public parks & open spaces, public transportation system, and life supporting facilities. (3) The place identity was enhanced through the preservation of urban structure-tissues, renovation of existing buildings, and preservation of historical heritages.

A Study on the Standard Drawings of Seoul Middle School Architecture in 1975 (1975년 서울시 중학교 표준설계도에 관한 연구)

  • Lee, Jeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2497-2504
    • /
    • 2013
  • This study aims to analyze the 'Standard Drawings for School Facilities' issued by Seoul Education Committee in 1975 because it is the early example for middle school architecture. The results of this study are summarized as follows 1) In general trend of single-corridor type block plan, there are also changes in floor plan like no-corridor type block plan, $9.9{\times}6.6m$ classroom unit for the better daylight condition, built-in storage for students. 2) As for elevation design, it is characterized as daylight-oriented, functional exterior for without making full use of design elements. 3) Standardized dimensions are used as a rule in the height of story, ceiling, window sill and etc. Transitional characteristics of the early RC school architecture are found in exposed ceiling, incomplete insulation structure and mixed use of wood framed floor of earlier type. 4) Contrast to main school building, gymnasium shows the intend to express the symbolism of school architecture with diverse elevation design elements and the plasticity of building mass. 5) Separated plan of toilet and night-duty building also show the transitional characteristics. As conclusion, though showing the stereotyped school architecture, on the other hand, 'Standard Drawings for School Facilities' (1975) makes it possible to see the way of coping with the demands for school architecture in that time and the transition of school architecture. This is the main value of it as the material for the studies related to the history of educational facilities.

A study on the color controlled of painter's work (페인트 도장공사의 색관리에 관한 연구)

  • Shim, Myung-Sup;Lee, Hyun-Jeong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.1
    • /
    • pp.107-114
    • /
    • 2003
  • This study aims to find methods that prevents aging of buildings paint coating and that limits defects in construction. Defects in painting can occur in four stages: pure paint, during painting, after the paint coating has dried, and after some period of time has passed after coating. Paint may become bad due to precipitation of pigments, formation of membranes, and seeding during manufacturing. Therefore, it is important that the paint is well mixed and kept airtight at a cool, dark place. Indents, paint brush strokes, orange peel, separation of colors, and paint running and spreading during the paint work process can be prevented by using high quality materials and applying a high-level of construction method. After the paint coating has dried, boiling, yellowing, poor drying, poor bonding, and/or glen deficiency may occur. These are influenced by the levels of cleanness of the dried product, drying temperature and hydration. Then, when the coating has been left dried for some period of time, cracking, peeling, scaling, swelling, discoloring, and/or rusting may develop due to the ultraviolet and contaminants in the air. Since these defects occur due to inappropriate construction schedule and/or hot and humid condition, one must use weatherproof materials. Furthermore, poor paint color may be caused by contamination in the sample plate, discoloration, and/or discrepancies in colors which are due to material differences, level of glossiness, degree of dispersion, dual color property of metallic colors, precipitation of pigments, etc. One should achieve reduction in construction cost and effectiveness in paint work by limiting contaminations in the construction site and strictly observing to construction regulations.

A Study on Economic Analysis Algorithm for Energy Storage System Considering Peak Reduction and a Special Tariff (피크저감과 특례요금제를 고려한 ESS 경제성 분석 알고리즘에 관한 연구)

  • Son, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.10
    • /
    • pp.1278-1285
    • /
    • 2018
  • For saving electricity bill, energy storage system(ESS) is being installed in factories, public building and commercial building with a Time-of-Use(TOU) tariff which consists of demand charge(KRW/kW) and energy charge(KRW/kWh). However, both of peak reduction and ESS special tariff are not considered in an analysis of initial cost payback period(ICPP) on ESS. Since it is difficult to reflect base rate by an amount of uncertain peak demand reduction during mid-peak and on-peak periods in the future days. Therefore, the ICPP on ESS can be increased. Based on this background, this paper presents the advanced analysis method for the ICPP on ESS. In the proposed algorithm, the representative days of monthly electricity consumption pattern for the amount of peak reduction can be found by the k­means clustering algorithm. Moreover, the total expected energy costs of representative days are minimized by optimal daily ESS operation considering both peak reduction and the special tariff through a mixed-integer linear programming(MILP). And then, the amount of peak reduction becomes a value that the sum of the expected energy costs for 12 months is maximum. The annual benefit cost is decided by the amount of annual peak reduction. Two simulation cases are considered in this study, which one only considers the special tariff and another considers both of the special tariff and amount of peak reduction. The ICPP in the proposed method is shortened by 18 months compared to the conventional method.

An Experimental Study for Strength Improvement of Soft Ground using Hardening Agent and Silicate Mineral Power (수용성 고화재와 규산염광물 결합재를 활용한 지반개량재의 실험적 연구)

  • Kim, Sung-Wook;Choi, Eun-Kyeong;Cho, Jinwoo;Lee, JuHyung;Lee, Kyu-Hwan
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.8-15
    • /
    • 2015
  • The demand for environmental consideration is on the increase in civil engineering. This study focuses on the development of technology to reduce the use of carbonate cement and improve its performance by using a silicate mineral and hardening agents, and presents the test results for the demonstrative evaluation of the properties of the raw material. Highly active feldspar was used as a binder to augment the bonding of the carbonate cement, and their change in strength was observed after test piece construction with the addition of soluble hardening agent. The uniaxial compression strength of the test piece of the general Portland cement with the addition of 0.5% soluble hardening agent, showed an increase by 33% and that of the test piece of cement with the addition of 70% substituted with feldspar increased by 28%. The strength of viscous soil; classified as soft ground, showed an increase of a maximum of 1.7 times when it was mixed with cement and solidifier depending on the curing period. These tests confirmed that a soluble solidifier is effective for improving the strength of a cement binder and that the highly active feldspar can be used as a binder.

The Execution and Estimation of Construction Cost of High Fluidity Concrete Applying Flowing Concrete Method (유동화공법에 의해 제조한 고유동 콘크리트의 시공 및 원가분석)

  • Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.2
    • /
    • pp.129-136
    • /
    • 2004
  • High fluidity concrete(HFC) requires high dosage of superplasticizer to acquire sufficient fluidity, and high contents of fine powder and viscosity enhancing admixtures to resist segregation. The use of high amount of admixtures to make HFC at batcher plant in ready mixed concrete company is one of the reasons to raise the manufacturing cost of HFC. For this reason, new type of manufacturing method of HFC are described using both flowing concrete method and segregation reducing superplasticizer(SRS) in order to gain economical profit and offer the convenience for quality control.. As dosage of melamine based superplasticizer increases, it shows that fluidity and bleeding increase, while air contents and ratio of segregation resistance decrease. It also shows that addition of viscosity agent into superplasticizer reduce bleeding and improve segregation resistance of concrete. Dosage of AE agent into superplasticizer containing viscosity agent recovers loss of air contents during flowing procedure. Combination of proper contents of superplasticizer, viscosity agent and AE agent make possible to develope segregation reducing type superplasticizer. Compressive strength of high fluidity concrete applying flowing method with it is higher than that of base concrete. No differences of compressive strength between compacting methods are found. For the estimation of construction cost of high fluidity concreting using segregation reducing type superplasicizer, under same strength levels, although material cost of high fluidity concrete is somewhat higher than that of plain concrete due to segregation reducing type superplasticizer cost, labor cost and equipment cost of high fluidity concrete is cheaper than that of plain concrete. However, based on the strength differences, high fluidity concrete shows lower material cost, labor cost and equipment cost than that of plain concrete due to decreasing in size of member and re-bar caused by high strength development of concrete.

A Study on the Estimation of Adhesive Stability According to Organic.lnorganic Mixed Tile Bond Type for Application of Polishing Tile to Dry Wall System (건식벽체에 폴리싱타일을 적용하기 위한 유기.무기질 혼합계 타일접착제 종류에 따른 부착안정성 평가에 관한 연구)

  • Oh, Sang-Keun;Lee, Gi-Jang;Yoo, Jae-Kang;Kim, Su-Ryun;Lee, Sung-Il
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.3
    • /
    • pp.163-170
    • /
    • 2002
  • Recently, polishing tile(porcelain homogeneous polished tile) was used in the construction field as a finishing material. But, there happened some problems such as tile exfoliation by construction condition in early ages. Also, for use of polishing tile in the dry wall system which used to lightweight wall, the examination of adhesive stability of polishing tile is needed. In this study, adhesive strength of Polishing tile was investigated by tile bond types on gypsum board and non asbestos board coated by tar-urethane and Polymer modified cementitious waterproofing membrane(Series I). Then, the effect of heat stress and vibration was estimated on gypsum and non asbestos board(Series II). As the result of study are the follows; (1) Polishing tile(600$\times$400mm) construction on waterproofing layer : Both laboratory estimation and spot examination sieve were happened that fall of tile because their hardening speed is late. (2) To using powder style adhesives in the dry wail with waterproofing layer : Adhesive strength of tile is Influenced by interface bond area and base side condition. (3) Shock and heat stresses : obvious decline of adhesive strength is not happened

Fundamental Physical Properties of Cement Composites Containing Fineness Reject Ash (고분말 리젝트애시를 혼입한 시멘트복합체의 기본물성에 관한 연구)

  • Lee, Kang-Pil;Hong, Man-Gi;Lee, Sang-Soo;Song, Ha-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.4
    • /
    • pp.363-370
    • /
    • 2011
  • This study considerated reject ash, wastes of coal-fired power plants, to use mineral admixtures for cement. The pozzolan activity selected the fineness of the efficient reject ash through comparison and it compared to the fly ash that are widely used for concrete mixed material. Cement composites was prepared replacing of slag cement by fineness reject ash and fly ash, and properties of cement composites was tested by paste(setting time, fluidity, instrumental analysis) and mortar(compressive strength). Instrumental analysis results showed hydration reaction of fineness reject ash was not different from fly ash, but had more dense micro structures. Results of physical properties showed fineness reject ash shorten setting time, increased compressive strength compared by fly ash. Therefore using fineness reject ash with $6,000cm^2$/g to concrete mineral admixtures or cement composites was might be possible and could contribute to improve properties of concrete.