• 제목/요약/키워드: mixed flow pump

검색결과 62건 처리시간 0.024초

두영역모델을 사용한 원심펌프의 성능예측 (Performance Prediction of Centrifugal Pumps using a Two Zone Model)

  • 최영석;심재혁;강신형
    • 한국유체기계학회 논문집
    • /
    • 제2권1호
    • /
    • pp.56-63
    • /
    • 1999
  • In this study, the performance prediction programs for centrifugal pumps are developed. To estimate the losses in the centrifugal pump impellers, a two-zone model and TEIS(two elements in series) model are applied to the program. The basic concept of a two zone model considers the primary zone that is an isentropic core flow and the secondary zone that has a non-isentropic region at the impeller exit. The flow goes through two different zones and is mixed out at the impeller exit and the mixing process occurs with an increase in entropy, a decrease in total pressure. The level of the core flow diffusion in an impeller was calculated using TEIS(two elements in series) model. The effects of various parameters which are used in this program on the prediction of head and efficiency are discussed. The correlation curves used to select the effectiveness of the primitive TEIS model were suggested according to the specific speed of the centrifugal pumps.

  • PDF

수직 오리피스 이젝터의 혼합유동 및 산소전달 특성 (Mixed Flow and Oxygen Transfer Characteristics of Vertical Orifice Ejector)

  • 김동준;박상규;양희천
    • 대한기계학회논문집B
    • /
    • 제39권1호
    • /
    • pp.61-69
    • /
    • 2015
  • 본 논문은 수직 오리피스 이젝터의 혼합유동 및 산소전달 특성에 대한 실험적 연구를 목적으로 한다. 실험장치는 전동 모터-펌프, 오리피스 이젝터, 순환 수조, 공기압축기, 고속 카메라 시스템 그리고 제어 및 측정기기로 구성하였다. 측정된 구동유체 및 유입공기의 유량을 이용하여 유량비를 도출하였다. 이적터에서 분출된 혼합유동의 가시화를 통해 정성적 거동을 고찰하였으며, 용존산소 농도를 측정하여 총괄 산소전달계수를 도출하였다. 구동유체의 유량이 일정하고 압축기의 공기압이 높아지면 유량비와 산소전달계수는 증가하며, 압축기의 공기압이 일정하고 구동유체의 유량이 증가하면 유량비는 감소하지만 산소전달계수는 증가하였다. 기포의 크기에 따른 체류시간 및 확산도와 수직 혼합유동의 도달거리는 2 상의 접촉면적과 시간에 크게 영향을 미치기 때문에 산소전달율의 중요한 변수임을 유추할 수 있다.

상사성을 이용한 model 사류펌프의 성능 예측 (Performance Prediction of Model Mixed Flow Pump Using Similarity)

  • 이덕형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.393-400
    • /
    • 2005
  • As one of the useful and powerful methods for designing the optimum pump is using model pump, it is based on the similarity characteristics of turbomachinery. With this theory, we can predict the performance of various pumps. In fact we have performed huge pumps using this, the experimental results were to be sufficient to prove the similarity characteristics. In this study, we predicted the performance of the huge proto-type pump that cannot be installed and made a test. First of all, we had calculated the model ratio between proto-type and model. There were two ways to estimate the performance. One was the application of CFD code, and the other way was model field test. So We selected both of them to guarantee the dependable data and evaluated each other.

  • PDF

체외순환중의 중심 정맥 산소포화도의 의의 (The Value of Mixed Venous Oxygen Saturation during and after Cardiopulmonary Bypass)

  • 이재원
    • Journal of Chest Surgery
    • /
    • 제28권1호
    • /
    • pp.7-10
    • /
    • 1995
  • Mixed Venous oxygenation saturation[SvO2 is a variable determined in part by the externally controlled factors and in part by the patient during CPB. I monitored the SvO2 and tested it as a parameter for the regulation of pump output and as a criteria for the need of inotropics after CPB. With the help of SvO2, I increased the pump flow especially during rewarming for more optimal oxygenation of cells. After CPB, the calculated cardiac index was used as an indicator for the need of inotropic support with greater accuracy and without any clinical problems. I conclude that the SvO2 is an easily checkable variable and a good indicator for optimal oxygenation at cell level, and can be used as an objective criteria for the need of postoperative inotropic support.

  • PDF

두영역모델을 사용한 원심펌프의 성능예측 (Performance Prediction of Centrifugal Pumps using Two Zone Model)

  • 최영석;심재혁;강신형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.33-41
    • /
    • 1998
  • In this study, the performance prediction programs for centrifugal pumps are developed. To estimate the losses in the centrifugal pump impellers, two-zone model and TEIS(two elements in series) model are applied to the program. The basic concept of two zone model considers the primary zone that is an isentropic core flow and the secondary zone that is non-isentropic region at the impeller exit. The flows through two different zones mixed out at the impeller exit and the mixing process occurs with an increase in entropy, a decrease in total pressure. The level of the core flow diffusion in a impeller was calculated using TEIS(two elements in series) model. The effects of various parameters which are used in this program on the prediction of head and efficiency are discussed. The correlation curves to select the effectiveness of the primitive TEIS model were suggested according to the specific speed of the centrifugal pumps.

  • PDF

필터방식을 이용한 이산화질소 및 호흡성 분진의 동시 측정 (Simultaneous NO2 and RSP Measurements Using Filtration Method)

  • 양원호;임성국;김문현
    • 한국환경보건학회지
    • /
    • 제34권2호
    • /
    • pp.148-152
    • /
    • 2008
  • Coated filters were developed to replace the glass impinger methods that use reagent solutions. The purpose of this study was to simultaneously measure nitrogen dioxide ($NO_2$) and respirable suspended particles (RSP) by a filtration method with a cyclone connected to a pump. A first pre-filter for RSP and second filter for $NO_2$, which was soaked in a TEA (Triethanolamine) solution, were loaded into a filter cassette with a pump flow rate of 1.7 l/m. After sampling, the TEA soaked filter was removed from the cassette, placed in a large test tube (10 ml), mixed, and allowed time to develop. The absorbance (abs) of the diazo compound of the $NO_2$ and N-(1-Napthylethylenediamine dihydrochloride) in the color reagent was measured at 545 nm on a spectrophotometer. The collection efficiency(%) of $NO_2$ by each 3 filter soaked in TEA solution and used in the cyclone with a pump flow rate 1.7 l/m was $89{\pm}3%$ and the correlation coefficient between the true $NO_2$ concentration and that determined by the TEA soaked filters was 0.993(p<0.001).

저유량 마취를 위한 전자제어식 기화기 개발 (A Development of the electronic controlled vaporizer for low flow anesthesia)

  • 오영택;박재훈;장인배
    • 산업기술연구
    • /
    • 제29권B호
    • /
    • pp.107-113
    • /
    • 2009
  • For the environmental safety of the operating room and patient healthcare, the closed type rebreathing system is widely adopted. In order to reduce the anesthesia gas during surgery, the mixing ratio of anesthesia gas with breathing air should be precisely controlled. Generally, the breathing air passes through the vaporizer to mix the anesthesia gas, but there is a difficulty in controlling the mixing ratio precisely. In this paper, the stand-alone style vaporizer is designed and the operating characteristics are investigated. The vaporizer measures the temperature and pressure in the vaporizing chamber and chamber temperature is precisely controlled by proportional controlled heater. Exact quantity of anesthesia media is feeded by PID controlled peristaltic pump and vaporized gas is mixed with breathing air flow by PWM controlled solenoid valve. The experimental result shows that the vaporizer has an excellent command following performances that it can be applied to the low flow anesthesia system.

  • PDF

Electrodeposition of Mn-Ni Oxide/PEDOT and Mn-Ni-Ru Oxide/PEDOT Films on Carbon Paper for Electro-osmotic Pump Electrode

  • Baek, Jaewook;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권2호
    • /
    • pp.93-98
    • /
    • 2018
  • $MnO_2$, a metal oxide used as an electrode material in electrochemical capacitors (EDLCs), has been applied in binary oxide and conducting polymer hybrid electrodes to increase their stability and capacitance. We developed a method for electrodepositing Mn-Ni oxide/PANI, Mn-Ni oxide/PEDOT, and Mn-Ni-Ru oxide/PEDOT films on carbon paper in a single step using a mixed bath. Mn-Ni oxide/PEDOT and Mn-Ni-Ru oxide/PEDOT electrodes used in an electro-osmotic pump (EOP) have shown better efficiency compared to Mn-Ni oxide and Mn-Ni oxide/PANI electrodes through testing in water as a pumping solution. EOP using a Mn-Ni-Ru oxide/PEDOT electrode was also tested in a 0.5 mM $Li_2SO_4$ solution as a pumping solution to confirm the effect of the $Li^+$ insertion/de-insertion reaction of Ruthenium oxide on the EOP. Experimental results show that the flow rate increases with the increase in current in a 0.5 mM $Li_2SO_4$ solution compared to that obtained when water was used as a pumping solution.

습식 숏크리트 뿜칠 장비의 급결제 유량 제어 시스템 개발 (Development of Accelerator Control System for Wet Shotcrete Spraying Equipment)

  • 강태호;장수호;최순욱;김진태;김봉규;이철호
    • 터널과지하공간
    • /
    • 제32권6호
    • /
    • pp.353-362
    • /
    • 2022
  • 숏크리트 습식 공법은 모든 재료를 혼합한 후 분사장치에 공급하여 노즐에 압축공기를 추가하고 분사속도를 향상시켜 타설면에 뿜어 붙이는 공법을 말한다. 현장의 습식 공법에서 사용되는 숏크리트량과 현장 상황을 실험실 규모에서 재현하기 위해서는 장비의 토출량 제어가 필수적으로 요구된다. 본 연구에서는 실험실 규모에서 현장 상태의 재현성을 높이기 위해 숏크리트 몰탈 뿜칠 장비의 급결제 유량 제어 시스템을 개발하여 장비에 적용하였다. 개발된 장비의 검증을 위해 물과 몰탈을 이용한 토출량 제어 시험을 수행하였다. 개발된 제어 시스템은 모노 펌프에 대해 사용자 입력값에 따라 토출량 제어가 원활하게 이루어 졌으나 감속기가 부착된 스크류 펌프에 대해서는 입력값에 따라 원활하게 토출량 제어가 이뤄지지 않았다. 감속기가 부착된 경우, 모노 펌프 가동률은 낮추면서 스크류 펌프의 가동률을 높여서 목표로 하는 급결제 유량에 근접하게 조절하는 방안이 필요하다.

워터제트의 임펠러 입구와 출구 각도에 따른 성능해석 (Performance Analysis based on Impller Inlet & Outlet Angle for Waterjet)

  • 강민규;박동진;강한빈;이석순
    • 항공우주시스템공학회지
    • /
    • 제5권2호
    • /
    • pp.27-32
    • /
    • 2011
  • The purpose of this study was to suggest 10 kinds of case and perform Mixed-flow pump optimum design and performance analysis depending on the shape of the impeller for suitable to water jet propulsion system. H20 was applied to the material properties, to analysis conditions for water jet axial impeller 1000 rpm given analysis was performed. Interpretation for each case as a result of speed, pressure, flow rate, calculate the thrust at the Inlet Angle $30^{\circ}$ and Outlet Angle $30^{\circ}$ could see a persistence of optimal performance.