• 제목/요약/키워드: mix-proportion

검색결과 354건 처리시간 0.023초

화음탐색법을 이용한 강섬유 및 하이브리드 섬유보강 콘크리트의 최적배합 설계 (Optimal Mix Proportion of Steel Fiber and Hybrid Fiber Reinforced Concrete Using Harmony Search)

  • 이치훈;이주하;윤영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.280-283
    • /
    • 2004
  • Today, the guide line of the SFRC mix design and the construction was not embodied, and the convenience of the practical application on the spot is not good. In this research, hence, the program which is optimized to result the mix proportion by the flexural strength and toughness, was developed to apply with ease SFRC on the practical spot. This program would minimize the number of trial mixes and achieve an economical and appropriate mixture. In addition, the theoretical background on which the program is based, will be the basis of the embodied method to mixing SFRC. New algorithm, in this research, was used to develop the mix proportioning program of SFRC. The new algorithm is the Harmony Search which is the heuristic method mimicking the improvisation of music players. And, beside to single fiber reinforced concrete, it was developed the program about the hybrid fiber reinforced concrete that two kinds of steel fibers, which have the different geometry, was reinforced. This will be able to keep the world trend to study, hence, offers the basis of the next generation research.

  • PDF

고분자 기포제를 이용한 경량 기포 콘크리트의 개발(I) (Development of Lightweight Foamed Concrete Using Polymer Foam Agent)

  • 변근주;송하원;박상순
    • 콘크리트학회지
    • /
    • 제9권1호
    • /
    • pp.165-172
    • /
    • 1997
  • 경량기포콘크리트란 시멘트슬러리 속에 미리 생성된 기포를 혼합시켜 양생시킴으로써 동일한 체적의 보통콘크리트보다 가볍게 만든 콘크리트를 의미한다. 본 연구의 목적은 고분자기포제를 이용하여 초경량성과 타설에 충분한 유동성을 확보하면서 소요강도를 갖는 최적의 선기포방식의 경량기포콘크리트를 개발하는데 있다. 연구결과 실리카흄, 플라이애쉬 등의 혼화재와 산업부산물인 발포포리스티렌비드의 혼합으로 경량기포콘크리트의 역학적 특성을 개선시켜 기존의 선기포방식으로 제조된 경량기포콘크리트보다 유동성 , 경량성과 강도특성이 우수한 경량기포콘크리트를 개발하였다. 본 논문에서는 개발된 경량기포콘크리트의 여러 가지 배합인자에 따른 유동성 및 압축강도를 규명하였으며 최적 배합비를 도출하였다.

Dynamic mix design optimization of high-performance concrete

  • Ziaei-Nia, Ali;Shariati, Mahdi;Salehabadi, Elnaz
    • Steel and Composite Structures
    • /
    • 제29권1호
    • /
    • pp.67-75
    • /
    • 2018
  • High performance concrete (HPC) depends on various parameters such as the type of cement, aggregate and water reducer amount. Generally, the ready concrete company in various regions according to the requirements and costs, mix design of concrete as well as type of cement, aggregates, and, amount of other components will vary as a result of moment decisions or dynamic optimization, though the ideal conditions will be more applicable for the design of mix proportion of concrete. This study aimed to apply dynamic optimization for mix design of HPC; consequently, the objective function, decision variables, input and output variables and constraints are defined and also the proposed dynamic optimization model is validated by experimental results. Results indicate that dynamic optimization objective function can be defined in such a way that the compressive strength or performance of all constraints is simultaneously examined, so changing any of the variables at each step of the process input and output data changes the dynamic of the process which makes concrete mix design formidable.

진동제어 콘크리트 개발에 관한 실험적 연구(I) (Experimental Study for the Development of Vibration-Controlled Concrete (I))

  • 정영수;이대형;최우성
    • 콘크리트학회지
    • /
    • 제8권5호
    • /
    • pp.123-133
    • /
    • 1996
  • 최근의 각종 사회시설의 확충에 따른 건설공사 및 교통시설 등은 많은 진동을 유발하여 사회적인 문제를 야기하고 있는 실정이다. 본 연구는 각종 제진재료를 이용하여 진동을 억제할 수 있는 콘크리트를 개발하여 각종 건설공사에서 흔히 발생할 수 있는 진동공해문제를 억제하고자 하며 아울러 폐기물의 재활용차원에서 폐자재를 이용하여 유용한 제진콘크리트를 개발하고자 하는데 그 목적이 있다. 우선, 제진재료를 이용한 압축강도 200kg/$\textrm{cm}^2$ 이상의 콘크리트 배합비를 찾기 위하여 Pilot실험을 수행하였으며, 선정된 적정배합비에 다른 진동시험제를 제작하여 재료의 동적특성 즉, 1차공명진동수, 동탄성계수 및 감쇠비를 측정하여 제진효과를 조사하였다. 제진재료로서는 Foam, Latex, Rubber Powder 그리고 Plastic Resin 등을 사용하였으며 진동의 감쇠효과가 있는 것으로 나타났다. 실험방법으로는 KS F 2437 규정과 진동파의 속도법을 사용하였으며, 감쇠비 측정은 Frequency Response Spectrum 곡선에 대한 Polynomial Curvefitting방법과 기하학적 해석방법을 이용하여 각각의 결과를 비교.분석하였다.

포러스 콘크리트의 배합요인 및 골재 혼합비율이 강도 및 투수성능에 미치는 영향 (Influence of Mix Factors and Mixing Ratio of Aggregate on the Strength and Water Permeability of Porous Concrete)

  • 김무한;김규용;백용관
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.91-98
    • /
    • 2000
  • Porous concrete having continuous voids is gaining more interest as an ecological material. It has several useful functions such as water and air permeability, sound absorption, etc. Its strengths are considerably lower than those of conventional concrete due to the large and continuous voids in it. This study has been carried out to investigate the influence of mix factors and mixture proportion of aggregate on the strengths and water permeability of porous concrete. And it has been carried out to investigate the evaluation of void of porous concrete by the ultra-sonic pulse velocity. The results f this study are as follows: 1) The theoretical void ratio has greater influence than any other factor on the strengths and water permeability of porous concrete. And it is a little affected by the replacement proportion of silica-fume and mixture proportion of aggregate. 2) Because the coefficients of correlation between the void ratio and ultra-sonic pulse velocity were relatively high, it will be possible that the void ratio is predicted by the ultra-sonic pulse velocity.

Wet-mix Shotcreting Application of High Ductile Fiber Reinforced Mortar Designed by Optimizing Mix Proportion

  • 김윤용;김정수;김진근;하기주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.581-584
    • /
    • 2004
  • High ductile fiber reinforced mortar suitable for wet-mix shotcreting (sprayable ductile mortar) 10 the fresh state, while maintaining tensile strain-hardening behavior in the hardened state, has been developed based on micromechanics and workability control. In the development concept of sprayable ductile mortar, micromechanics is adopted to properly select the matrix, fiber, and interface properties to exhibit strain hardening and multiple cracking behaviors in the composites. Within the pre-determined micromechanical constraints, the workability is controlled by optimizing mix proportions. A series of spray tests show the excellent pumpability and sprayability of the sprayable ductile mortar. Subsequent direct tensile tests demonstrate that the tensile performance of sprayed mortar is comparable to that of cast mortar, for the same mix design.

  • PDF

A Study on the Optimum Mix Proportion of the Mass Concrete Designed as Massive and Deep Structure

  • Kwon Yeong-Ho;Lee Hwa-Jin
    • 콘크리트학회논문집
    • /
    • 제17권2호
    • /
    • pp.293-302
    • /
    • 2005
  • This study describes data from determination of the optimum mix proportion and site application of the mass concrete placed in bottom slab and side wall having a large depth and section as main structures of LNG in-ground tank. This concrete requires low heat hydration, excellent balance between workability and consistency because concreting work of LNG in-ground tank is usually classified by under-pumping, adaptation of longer vertical and horizontal pumping line than ordinary pumping condition. For this purpose, low heat Portland cement and lime stone powder as cementitious materials are selected and design factors including unit cement and water content, water-binder ratio, fine aggregate ratio and adiabatic temperature rising are tested in the laboratory and batch plant. As experimental results, the optimum unit cement and water content are selected under $270kg/m^3$ and $l55{\~}l60 kg/m^3$ separately to control adiabatic temperature rising below $30^{\circ}C$ and to improve properties of the fresh and hardened concrete. Also, considering test results of the confined water ratio($\beta$p) and deformable coefficient(Ep), $30\%$ of lime stone powder by cement weight is selected as the optimum replacement ratio. After mix proportions of 5cases are tested and compared the adiabatic temperature rising($Q^{\infty}$, r), tensile and compressive strength, modulus of elasticity, teases satisfied with the required performances are chosen as the optimum mix design proportions of the side wall and bottom slab concrete. $Q^{\infty}$ and r are proved smaller than those of another project. Before application in the site, properties of the fresh concrete and actual mixing time by its ampere load are checked in the batch plant. Based on the results of this study, the optimum mix proportions of the massive concrete are applied successfully to the bottom slab and side wall in LNG in-ground tank.

17세기~19세기 영건 및 산릉의궤에 기록된 벽체에 관한 연구 - 벽체의 구성 및 미장재의 혼합비를 중심으로 - (A Study on the Walls Recorded in the Yeonggeon-and Sanreng-uigwes in the 17th-19th Centuries - Focusing on the composition of wall and mixing ratio of plaster materials -)

  • 황희영;권양희
    • 대한건축학회논문집:계획계
    • /
    • 제36권5호
    • /
    • pp.105-116
    • /
    • 2020
  • In this study, the royal protocols of the Joseon Dynasty, known as uigwes, were reviewed to clarify the materials and structure of Korean traditional walls. For this, the Yeonggeon-and Sanreng-uigwes were thoroughly reviewed, and then the names, materials, and construction methods of the traditional walls were systematically organized. In addition, mix proportions of plastering materials used in the walls were estimated based on the records in the uigwes; these were compared with the ratios specified in the current specifications. As a result of the comprehensive review, it was found that the mix proportions of the plastering materials varied depending on importance of buildings, type of walls, and the raw materials. Based on this, it was concluded that the characteristics of each uigwe should be considered when studying the mix proportion of materials for the traditional walls. It was also found that there were differences between the traditional and modern specifications for the wall constructions. That is, historical records and the specifications currently used were different in terms of constituent materials, construction methods and mix proportions. As a cause of the difference, the disconnection of the traditional methods and the introduction of foreign plastering techniques during the rapid social change in the 20th century were suggested.

도로유실 복구를 위한 골재 충전 고흐름도 모르타르의 기초 배합 연구 (Fundamental Study of Mix Proportions of High-Flow Cement-Based Mortar for Gravel-Fill Used in Restoration of Collapsed Roads)

  • 조현명;전상표;김승원;윤경구;박철우
    • 한국도로학회논문집
    • /
    • 제17권2호
    • /
    • pp.63-70
    • /
    • 2015
  • PURPOSES: As a part of our research into repair techniques for roads that have collapsed as a result of a natural disaster, this study set out to find the optimum mix proportion for gravels to be used to restore a damaged area. METHODS: This study considered flow and strength-development characteristics. The experimental variables were the W/C ratio, the usage of the admixture, the types of cement, and the quantity of fine aggregate over three different experimental stages. The compressive strength was measured at 12 hours, one day, three days, and seven days. RESULTS : The flow varied with the amount of fine aggregate and the use of a high-range water-reducing (HRWR) admixture. The compressive strength also varied with respect to the type of cement and the W/C ratios. The strength satisfied the expected requirement of 21 MPa after one day, provided the mix proportion was appropriate. CONCLUSIONS: A gravel-filling high-flow cement-based mortar exhibited strength and consistency with a W/C ratio in the range of 0.40 to 0.45, assuming the use of HRWR at 0.5 to 0.7% and a fine aggregate/cement ratio of 1.0 to 1.5.

순환굵은골재, 황토, 고로슬래그 미분말 및 마섬유를 사용한 레인가든 구조물 콘크리트의 최적배합설계 및 역학적 특성 (Optimum Mix Proportion and Mechanical Properties of Rain Garden Structure Concrete using Recycled Coarse Aggregate, Hwang-Toh, Blast Furnace Slag and Jute Fiber)

  • 김동현;박찬기
    • 한국농공학회논문집
    • /
    • 제55권3호
    • /
    • pp.25-33
    • /
    • 2013
  • In this study, the optimum mix proportions of rain garden structure concrete were decided and the mechanical properties were evaluated. Experimental parameters were blast furnace slag, hwang-toh, recycled aggregates and natural jute fibers. The target compressive strength and chloride ion penetration were more than 24 MPa and less than 1000 coulombs, respectively. The response surface method was used for statistical optimization of experimental results. The optimal mixing ratios of the blast furnace slag, hwang-toh, recycled coarse aggregate and jute fiber volume fraction were determined 59.98 %, 8.74 %, 12.12 % and 0.2 %, respectively. The compressive strength, flexural strength and chloride ion penetration test results of optimum mix ratio showed that the 24.56 MPa, 3.88 MPa and 999.08 columbs, respectively.