• Title/Summary/Keyword: mirror effect

Search Result 225, Processing Time 0.022 seconds

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF

Performance improvement of underwater target distance estimation using blind deconvolution and time of arrival method (블라인드 디컨볼루션 및 time of arrival 기법을 이용한 수중 표적 거리 추정 성능 향상 기법)

  • Han, Min Su;Choi, Jea Young;Son, Kweon;Lee, Phil Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.6
    • /
    • pp.378-386
    • /
    • 2017
  • Accurate distance measurement between maneuver target in underwater and measuring devices is required to perform quantitative test evaluation in marine weapons system R&D process. In general, the target distance is measured using a one-way ToA (Time of Arrival) method that calculates the time difference between transmitted and received signals from the two accurately synchronized devices. However, the distance estimation performance is degraded because of the multi-path environments. In this paper, the time-variant transfer function of complex underwater environment is estimated from each received data frame using RBD (Ray-based Blind Deconvolution), and the estimated time-variant transfer function is then used to get rid of the effect about complex underwater environment and to recover the data signal using PTRM (Passive Time Reversal Mirror). The result from the simulation and experimental data show that the suggested method improve the distance estimation performance when comparing with the conventional ToA method.

Study on Performance Improvement in Magnetic Abrasive Polishing Assisted by Silicone Gel Medium (실리콘 겔에 의한 자기연마가공의 성능 향상에 관한 연구)

  • Kim, Sang-Oh;Kwak, Jae-Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1499-1505
    • /
    • 2010
  • In general, magnetic abrasive polishing can be used to effectively produce a mirror-like surface; however, industrial applications of this process involve some unsolved problems. For example, the polishing efficiency is low, and the used abrasives have to be treated. In this study, which is aimed at solving these problems, a novel medium of silicone gel, consisting of ferromagnetic particles and abrasives, is developed, and the effect of this medium is assessed on the basis of Taguchi's experimental method. The workpiece is a tungsten carbide steel and the surface roughness after magnetic abrasive polishing using the silicone gel is evaluated.

The Effect of Action Observation Training on Balance in Patients with Chronic Stroke (동작관찰훈련이 만성 뇌졸중 환자의 균형능력에 미치는 영향)

  • Choi, Hyo-Seung;Nam, Ki-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3759-3765
    • /
    • 2014
  • This study examined the effects of action observations on the balance of patients with chronic stroke. The study period was between July 8, 2013 and August 10 2013. The participants were divided randomly into either the landscape picture observation group (n=20) and the action observation group (n=20). Each group observed the landscape pictures and video-recorded action-related balance for 5 minutes, respectively. Both groups had a balance training session for 10 minutes after the picture and video observations. The balance training sessions were repeated twice a day, three times a week for 6 weeks. As a result, significant improvement was noted in the action observation group than the landscape picture observation group for static balance and dynamic balance (p<.05). Consequently, the combination of action observation and balance training is believed to help improve the balance recovery for patients with chronic stroke.

Design of Heliostat Field for 200kW Tower Type Solar Thermal Power Plant (200kW 탑형 태양열발전시스템의 Heliostat Field 설계)

  • Park, Young Chil
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.41-51
    • /
    • 2012
  • Heliostat field is the most important subsystem in the tower type solar thermal power plant since its optical performance affects the total system efficiency most significantly while the construction cost of it is the major part of total construction cost in such a power plant. Thus a well designed heliostat field to maximize the optical efficiency as well as to minimize the land usage is very important. This work presents methodology, procedures and result of heliostat filed design for 200kW solar thermal power plant built recently in Daegu, Korea. A $2{\times}2(m)$ rectangular shaped receiver located at 43(m) high and tilted $28^{\circ}$ toward heliostat field, 450 of heliostats of which the reflective surface is formed by 4 of $1{\times}1(m)$ flat plate mirror facet, and the land area having about $140{\times}120(m)$ size are used to form the heliostat field. A procedure to deploy 450 heliostats in radial staggered nonblocking formation is developed. Also the procedures to compute the cosine effect, intercept ratio, blocking and shading ratio in the field are developed. Finally the heliostat filed is designed by finding the optimal radial distance and azimuthal spacing in radial staggered nonblocking formation such that the designed heliostat field optical efficiency could be maximized. The designed heliostat field has 77% of annual average optical efficiency, which is obtained by annually averaging the optical efficiencies computed between the time of where sun elevation angle becomes $10^{\circ}$ after sunrise and the time of where sun elevation angle becomes $10^{\circ}$ before sunset in each day.

The Development and Application of Teaching Program to Utilize Emotional Intelligence Elements in Elementary School Science (초등학교 과학교과에서 정서지능 요소를 활용한 수업 프로그램의 개발과 적용)

  • Park, Jae-Keun;Moon, Bo-Ra
    • Journal of Korean Elementary Science Education
    • /
    • v.33 no.1
    • /
    • pp.82-94
    • /
    • 2014
  • The purpose of this study is to develop teaching program which utilizes emotional intelligence elements as a measure to stimulate the motive and scientific attitude of learners and examine the effect of its application. The target unit for this study is 'world of plants' in the fourth grade of elementary school, and the teaching program is composed of 3 stages including I(encounter with myself), S(encounter with science), and U(encounter with friends). The teaching program is organized in the way to reflect 5 emotional intelligence elements including self-awareness, self-regulation, self-motivation, sympathy, and personal relations properly according to each stage of teaching program. The result of applying this program into actual classrooms is as follows. First, it is proven that the teaching program actually helps improving the motive of learners to study science. The emotional intelligence takes a role of positive motive for thinking, and the learners monitor their emotion and behavior patterns by using a mirror notebook to reduce their anxiety about science. Second, it is proven that the teaching program changes the science related attitude of learners positively. The emotional intelligence elements help the learners to create friendly feeling toward science subject and have a friendly attitude toward science and a sense of expectancy to science class. Third, it is proven that the teaching program contributes to the improvement of learners' science study achievement. The emotional intelligence takes an important role in improving the learners' science study achievement through the role of adjusting and controlling the recognition capability. However, emphasizing the emotional intelligence excessively also has a risk to break the balance between emotion and recognition, so it is considered that the balanced approach should be applied.

A CMOS Bandgap Reference Voltage/Current Bias Generator And Its Responses for Temperature and Radiation (CMOS Bandgap 기준 전압/전류 발생기 및 방사능 응답)

  • Lim, Gyu-Ho;Yu, Seong-Han;Heo, Jin-Seok;Kim, Kwang-Hyun;Jeon, Sung-Chae;Huh, Young;Kim, Young-Hee;Cho, Gyu-Seong
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1093-1096
    • /
    • 2003
  • 본 논문에서는, CMOS APS Image Sensor 내에 포함되어 회로의 면적을 줄인 새롭게 제안된 CMOS Bandgap Reference Bias Generator (BGR)를 온도 및 방사능에 대한 응답을 실험하였다. 제안된 BGR 회로의 설계 목표는 V/sub DD/는 2.5V이상이고, V/sub ref/는 0.75V ± 0.5mV 마진을 가지게 하는 것이다. 제안된 BGR회로는 Level Shifter를 갖는 Differential OP-amp단과 Feedback-Loop를 가지는 Cascode Current Mirror를 사용하여 저전압에서도 동작을 가능하게 하였으며, 높은 출력저항 특성을 가지도록 하였다. 제안된 BGR회로는 하이닉스 0.18㎛ ( triple well two-poly five-metal ) CMOS 공정을 이용하여 Test Chip을 제작하였다. 온도의 변화와 Co-60 노출조건 하에서 Total ionization dose (TID) effect된 BGR회로의 V/sub ref/를 측정하여, 이를 평가하였다. 온도에 대한 반응은, 25℃ 일 때의 V/sub ref/에 대해, 각각 45 ℃에서 0.128%. 70℃에서 0.768% 변화하였다. 그리고 온도가 25℃일 때 50krad와 100krad의 방사능을 조사 하였을 경우, V/sub ref/는 각각 2.466%, 그리고 4.612% 변화하였다.

  • PDF

Fatty Acid Composition of Fry Mirror Carp (Cyprinus carpio) Fed Graded Levels of Sand Smelt (Atherina boyeri) Meal

  • Gumus, Erkan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.2
    • /
    • pp.264-271
    • /
    • 2011
  • The effect of replacement of fish meal (FM) in diets with sand smelt meal (SSM) on fatty acid composition of carp fry, Cyprinus carpio, was examined. Five isonitrogenous and isoenergetic (38% crude protein, $15.75\;kJ\;g^{-1}$) diets replacing 0, 25, 50, 75, and 100% FM protein by SSM protein were formulated. Each diet was randomly allocated to triplicate groups of fish in aquaria, and each aquarium was stocked with 20 fish (initial average weight of $0.300{\pm}0.65\;g\;fish^{-1}$). Fish were fed twice daily to apparent satiation for 13 weeks. Results indicated that final weight, specific growth rate and feed efficiency ratio of fish fed with different SSM replacement diets did not differ significantly (p>0.05) from fish fed the control diet, except for 100% SSM level. No significant differences were noted among experimental treatments on dry matter, protein, lipid and ash contents of the fish body composition (p>0.05). Fatty acid analysis showed that saturated fatty acids in fish muscle significantly decreased, but monounsaturated fatty acids (MUFA) and polyunsaturated fatty acids (PUFA) did not change with increasing dietary SSM. However, some changes also could be observed for some particular fatty acids in experimental fish. For example, the amounts of 15:0, 17:0, 18:1n-7, 18:2n-6 and 22:5n-3 significantly increased, but 16:0, 18:1n-9, 18:3n-3 and 20:1 n-9 significantly decreased with increasing dietary SSM. Total n-6 PUFA increased with increasing dietary SSM, but total n-3 PUFA were not changed in muscle of fish fed the experimental diets. The ratio of n-3 to n-6 was not affected significantly in muscle of fish fed the experimental diets containing different proportions of SSM, including the control diet.

Development of a Surface Roughness Measurement Method Using Reflected Laser Beam Image and Its Application (레이저광 반사 화상을 이용한 표면 거칠기 측정법의 개발과 적용)

  • Yun, Yun-Feng-Shen;Kim, haa-young;An, jung-hwan;Chi, ei-jon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.11
    • /
    • pp.51-57
    • /
    • 2001
  • A light beam reflected from a machined surface generally containes information concerning about its surface roughness. This study examines and proposes a surface roughness measurement technique for on-machine measurement of machined surfaces. The technique is based on the measurement of a reflected laser beam pattern and the statistical analysis of its light intensity distribution. The surface roughness was found to be closely related to the standard deviation of the light intensity on the primary axis of the reflected pattern. An image acquisition device is made up of a laser diode, a half mirror, a screen, and a CCD camera. The exact image with the primary and secondary axes of a reflected laser beam pattern is calculated through such image processing algorithm as thresholding, edge detection, image rotation, segmentation, etc. A median filter and a surrounding light correction algorithm are improve the image quality and reduce the measuring error. Using the developed measuring device the effect of screen materials and workpiece and workpiece materials was investigated. Experimental results regarding to relatively high-quality surfaces machined by grinding, polishing, lapping processes have shown the measurement error is within 10% in the range of $0.1{mu}m~0.8{\mu}m R_q.$Therefore, the proposed method is thought to be effectively used when quick measurements is needed with workpieces fixed on the machine.

  • PDF

A Study on Polishing of Grooved Surface by the Second-Generation Magnetic Abrasive Polishing (2 세대 자기연마를 이용한 미세 그루브형상 표면가공에 관한 연구)

  • Kim, Sang-Oh;Lee, Sung-Ho;Kawk, Jae-Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1641-1646
    • /
    • 2011
  • The second-generation magnetic abrasive polishing is one of the nontraditional machining technologies newly developed. Because of the flexibility effect in magnetic abrasive polishing, the precise and mirror like surface can be obtained during this process. In this study, magnetic abrasive polishing process was applied in small grooved surface. As a result, it was seen that the flexible magnetic abrasive tool was effective to remove burrs on the edge of the groove. However, the efficiency of magnetic abrasive polishing at the slot was very low according to increasing depth and width of slot. So, correlation between geometric parameters, such as the depth and width, and surface roughness was evaluated and the minimum width for suitable polishing was found by experimental results.