• Title/Summary/Keyword: minitab 17

Search Result 23, Processing Time 0.025 seconds

A Comparison of Multivariate R-Techniques in SAS, SPSS, Minitab and S-plus (SAS, SPSS, MINITAB, 5-PLUS에서 다변량 R-기법의 비교)

  • 최용석;문희정
    • The Korean Journal of Applied Statistics
    • /
    • v.17 no.1
    • /
    • pp.153-164
    • /
    • 2004
  • In this study, we compare multivariate R-techniques in the up-to-date versions of SAS, SPSS, Minitab and S-plus. The direct input method by typing in command is considered for SAS, while the menu-driven method is considered for SPSS, Minitab and S-plus. Comparison was made in terms of input data format, input option, charts and outputs.

An Evaluation of Induced Voltage according to the Grounding Resistance of a 22.9 kV-Y Distribution Line Simulated for its Field Application for Lightning Prevention (낙뢰 예방 배전선로의 현장 적용을 위해 모의된 22.9 kV-Y의 접지저항에 따른 유도전압의 평가)

  • Kim, Jeom-Sik;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.14-19
    • /
    • 2015
  • This study performed simulation tests to prevent induced lightning that occurs to a 22.9 kV-Y distribution line. A simulated distribution line reduced to 1/50 of an actual distribution line was installed to measure the induced voltage according to the change in grounding resistance. It was found that the induced voltage increased as the grounding resistance increased but that the range of its increase was small. This study examined the reliability of the proposed lightning preventive distribution line using the Minitab program (Minitab 17). When a grounding resistance of $300{\Omega}$ was maintained for each electric pole, the Anderson Darling (AD) was 0.410, the smallest, and the P value was analyzed to be 0.323, verifying that the reliability and stability were excellent. Therefore, these results will be utilized as a basis for the substantiation of a lightning preventive distribution line before its installation.

Optimization of Distribution Basin Weirs at a Sewage Treatment Plant Based on Computational Fluid Analysis Using the Taguchi and Minitab Method (전산유체해석과 다구찌 및 미니탭 방법을 활용한 하수처리장 분배조 웨어 최적화)

  • Jung, Yong-Jun;Park, Hae-Sik;Cho, Young-Man
    • Journal of Environmental Science International
    • /
    • v.30 no.12
    • /
    • pp.983-991
    • /
    • 2021
  • The role of the distribution basin role is to apportion incoming raw water to the primary sedimentation basin as part of the water treatment process. The purpose of this study was to calculate the amount of water in the distribution basin using computational fluid dynamics (CFD) analysis and to find a way to improve any non-uniformity. We used the Taguchi method and the minitab tool as optimization methods. The results of the CFD calculation showed that the distribution flow had a deviation of 5% at the minimum inflow, 10% at the average inflow, and 22% at the maximum inflow. At maximum flow, the appropriate heights of the 7 weirs(C, D, A, B, E, F, G) were 40 mm, 20 mm, 20 mm, 0, 0, 0, and 20 mm, respectively, according to the Taguchi optimization tool. Here, the maximum deviation of the distribution amount was 9% and the standard deviation was 23.7. The appropriate heights of the 7 weirs, according to the Minitab tool, were 40 mm, 20 mm, 20 mm, 0, 0, 0, and 20 mm, respectively, for weirs C, D, A, B, E, F, and G. Therefore, the maximum deviation of the distribution amount was 8% and the standard deviation was 17.1, which was slightly improved compared to the Taguchi method.

A Study on the Selection of Cutting Conditions in High Speed Pipe Cutting Machine (고속 파이프 절단기의 절단 조건 선정에 관한 연구)

  • Ahn, Sung-Hwan;Shin, Sang-Hun;Lee, Choon-Man
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.144-149
    • /
    • 2008
  • This study presents the selection of cutting conditions in high speed pipe cutting machine for the better quality. A high speed pipe cutting machine which uses a rotary knife can make good quality products in short time. But, the machine is much sensitive by cutting conditions because of the complicated mechanism. In this reason, many experiments for cutting condition selection are necessary to improve quality of production. This study carried out cutting experiments with the three factors that are cutting RPM, cutting force and pooling force. 2-dimensional profile measuring instrument is used to measure which is represented by ${\Delta}h$, a sum of burr and collapse height. The effects of factors are analyzed by using MINITAB, the commercial software.

Study on decreasing displacement of the MC(machining center) moved column with high-speed for optimization of acceleration and DOE(Design Of Experiment) (가속도 최적화 및 형상 최적화를 통한 수직 컬럼 이동형 머시닝 센터의 진동 저감에 대한 연구)

  • Cho, Young-Duk;Lee, Choon-Man;Yoon, Sang-Hwan;Chung, Won-Jee
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.35-42
    • /
    • 2008
  • By the reason of increased demand of high productivity and quality, the manufacturer have an effort in many directions of a machine tool industries. Among there, we proposed method of decreasing displacement in MC(machining center). In other words, Quality related with vibration of a tool cutting products. For decreasing it, improved by optimizing a shape of the column-part and acceleration curves of motors. In this paper we could find design factors has much influence on decreasing the displacement using the DOE(Design of Experiments) and optimized the level of the factors using $ADAMS^{(R)}$ and $MINITAB.^{(R)}$ And we suggest optimized a acceleration curve using $Matlab^{(R)}$.

Verification of Reliability by the Induced Voltage of a Downscaled and Simulated 22.9kV-Y Distribution Line (축소 모의된 22.9 kV-Y 배전선로의 유도 전압에 대한 신뢰성 검증)

  • Kim, Jeom-Sik;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.26-31
    • /
    • 2015
  • The purpose of this paper is to measure the induced voltage of the downscaled and simulated overhead ground wire of a 22.9kV-Y distribution line. This study performed a test of the downscaled and simulated distribution line according to whether it is grounded or not and the value of the ground resistance. In order to verify the reliability of the data measured by the test, the data was analyzed using the Minitab 17 program. It was found that the induced voltage of the downscaled and simulated distribution line is influenced by the value of the ground resistance. It was also found that the ground resistance obtained at a certain point is closely related to whether electric poles are grounded or not. The analysis results of the measured test data with a statistical method showed that the Anderson Darling (AD) was analyzed to be the smallest as 0.188 when the ground resistance of the electric poles had been maintained at $10{\Omega}$. In addition, the P value analyzed to be 0.894 which is in the proximity of the theoretical value of 1 and verified the reliability of the test data. It could be seen that the data measured by the downscaled simulation test forms a linear graph. It is thought that if a distribution line is installed in the same manner as the downscaled, simulated distribution line, the mean induced voltage will be reduced and reliability will be increased.

Reliability Analysis of Access Door Opening Force Measured with a Digital Force Gauge of a Pressurized Smoke Control Zone and Presentation of Optimum Conditions for the Opening Force (디지털 측정기로 측정된 급기가압 제연구역의 출입문 개방력에 대한 신뢰성 분석 및 최적 조건 제시)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.468-473
    • /
    • 2016
  • The aim of this study was to measure the opening force of an access door of a pressurized smoke control zone and verify the reliability of the opening force. For the access door opening force, the opening load of the access door was measured before and after pressurized air had entered the smoke control zone. The reliability of the measured values was verified using the Anderson Darling's statistical analysis method of the Minitab Program. Because the analyzed P values were greater than 0.05 except for some floors before and after the operation of the smoke control equipment, the opening force was found to have 95% reliability. The normal distribution of the measured values showed no relationship with the operation of the smoke control equipment and the precision of the force gauge was believed to be reliable. The major factors for the optimal design of the pressurized smoke control equipment include the precision and reliability of the force gauge, the correct posture of the measuring person, and the same conditions for access doors. Therefore, a digital force gauge is believed to be suitable for measuring the opening force of the access door of a pressurized smoke control zone. In addition, standardization of the posture of a measuring person, the setup of the initial opening force of an access door, etc., are major variables for effective measurements of the door opening force of an access door.

Recognition and use of health information for preliminary elderly and elderly people (예비고령층과 고령층의 건강정보 경로별 인식과 활용)

  • Jung, Woo Sik;Kang, Hyung Gon;Han, Semi;Kim, Eunhye
    • Journal of Digital Convergence
    • /
    • v.19 no.6
    • /
    • pp.419-427
    • /
    • 2021
  • The purpose of this study is to identify the recognition and utilization of health information by acquisition channels for preliminary and elderly people. For the survey data of 200 people aged 55 to 64 and 200 seniors aged 65 or older, the chi-square test and Fisher's precision test were performed using MINITAB17. Although the two age groups were similar in obtaining health information through health professionals, preliminary elderly were more likely to obtain health information through mass media and Internet sites. In particular, the collection of health information through internet sites was more than four times higher than that of the elderly. While the preliminary people focused on searching the information on the health care and prevention, older people explored comprehensive information on health, including disease prevention and treatment, through each channel. Both groups showed positive recognition about the acquired health information. The results of this study confirmed that all channels, including internet sites, can be usefully used in the delivery of health-related information to the elderly in the future. In addition, it is suggested to consider age characteristics and health information utilized by each channel in the development of various contents for the improvement of self-health management of the elderly.

Optimization of Inner Nitriding Process for Cr-Mo-V Steel of Small Arms Barrel by using Taguchi Experimental Design Method (다구찌 실험계획법을 이용한 소구경화기 총열 내부용 Cr-Mo-V강의 질화공정 최적화)

  • Kwon, Hyuk-Rin;Kim, Dong-Eun;Son, Hyung-Dong;Shin, Jea-Won;Park, Jae-Ha;Kang, Myung-Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.3
    • /
    • pp.148-154
    • /
    • 2018
  • When shooting small arms, the inner surface temperature is heated up to about $700{\sim}1,000^{\circ}C$ by the friction of the bullet and the inner wall of the barrel and the combustion of propellant. High-temperature propellant gas and high-speed movement of the bullet cause corrosion of the inner wall, which is noticeable immediately in front of the chamber. In this study, the mechanical properties of Cr-Mo-V steel, which is the base material, were tested using Taguchi experimental design to find the best nitriding treatment conditions. For the nitriding process, the working time, salt bath temperature, and salt concentration were combined as three conditions and placed in the $L_9(3^4)$, orthogonal array table. The thicknesses of the white layer and the nitrogen diffusion layer were measured after nitriding under each condition in a salt bath furnace. Durability was evaluated by measuring the degree of dispersion through actual shooting because it was difficult to evaluate the mechanical properties of the cylinder inner structure. As a result, it was confirmed that the durability was optimal at $565^{\circ}C$, 1 hour, 0.5%. These optimal conditions were selected by the statistical analysis of the Minitab program(ver.17).