• Title/Summary/Keyword: miniplate

Search Result 84, Processing Time 0.029 seconds

Usability testing of a novel interlocking three-dimensional miniplate for mandibular angle fractures

  • Prasetyanugraheni Kreshanti;Aria Kekalih;Ahmad Jabir Rahyussalim;Sugeng Supriadi;Bambang Pontjo Priosoeryanto;Deni Noviana;Mendy Hatibie Oley;Chaula Luthfia Sukasah
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.4
    • /
    • pp.171-178
    • /
    • 2024
  • Background: We developed a novel interlocking three-dimensional (3D) miniplate design with an adjustable configuration. As this device is new, surgeons must become familiar with its application. This study evaluated the usability and learning curves associated with the novel interlocking 3D miniplate for mandibular fracture fixation. Methods: The study participants, nine plastic surgeons, were asked to apply an interlocking 3D miniplate and a standard miniplate to polyurethane mandible models. The participants had completed the Basic Craniomaxillofacial Osteosynthesis course during residency and had operated on craniomaxillofacial fractures within the past 5 years. They were instructed to place the interlocking 3D miniplate three times and the standard miniplate once. We assessed the time required for implant placement, the comfort level of the surgeons, and the biomechanical stability of the plates. Biomechanical testing was conducted by subjecting the mandible to forces ranging from 10 to 90 N and the displacement was measured. Results: The results indicate increasing comfort with each attempt at placing the interlocking 3D miniplate, with a significant difference between the first and third attempts. Additionally, a reduction in application time was noted with repeated attempts, suggesting improved efficiency. Biomechanical tests showed comparable stability between the tested plates. Conclusion: Multiple attempts at applying the interlocking 3D miniplate resulted in increased comfort and reduced application time. These findings indicate that, despite its novelty, the interlocking 3D miniplate is relatively straightforward to apply and has a short learning curve. However, surgeons must have specific qualifications to ensure proper training and minimize errors during placement.

The treatment of an impacted canine related with a miniplate inserted for mandibular fracture (하악골 골절 치료를 위한 miniplate와 관련된 매복견치의 치험례)

  • Hwang, Sang-Hee;Park, Hyo-Sang;Kwon, Tae-Geon;Nam, Ki-Young;Kim, Jong-Bae
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.148-152
    • /
    • 2005
  • This case report describes the treatment of an impacted tooth in relation to pediatric mandibular fracture. A 10-rear-old girl presented with au impacted mandibular canine related with a miniplate in the left mandibular body area. An ordinary surgical traction ended in failure. Good occlusion was established by removal of the miniplate. It would be considered important to make an exact diagnosis of the cause and remove the mechanical obstruction instantly for successful orthodontic treatment of an impacted tooth.

CLINICAL EVALUATION OF TREATMENT OUTCOME OF PLATING TECHNIQUE OF FIXATION FOR MANDIBULAR CONDYLAR FRACTURE (하악 과두 골절의 관혈적 정복시 고정 방법에 따른 임상적 평가)

  • Son, Jung-Hee;Park, Ji-Hwa;Kim, Chin-Soo;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.2
    • /
    • pp.164-170
    • /
    • 2005
  • The purpose of this study was to compare a sample of patients who had condylar fractures treated with open reduction using different plating techniques, to evaluate which plating technique is useful for stable fixation for fractures of the mandibular condyle and to evaluate effectiveness of resorbable miniplate. There were 60 patients (41 males, 19 females) whose condylar fractures were treated with open reduction. Rigid fixation was performed with a single miniplate, double miniplate ot one miniplate & one microplate and single resorbable plate. All patients remained intermaxillary fixation for 1 week postoperatively. Active physiotherapy was started after 2 weeks postoperatively. Radiographic evaluation (plate fracture, plate bending, screw loosening, displacement of condyle etc.) was performed at pre-operative, immediate, 2 weeks, 1 month, 3 months, 6 months after surgery. Clinical evaluation included degree of mouth opening, occlusion, mandibular lateral excursion, infection and facial nerve paralysis. In radiographic evaluation, displacement of fractured condylar segment associated with plate bending or screw loosening were showed 6 cases and 3 cases for single miniplate system and resorbable miniplate system. There was no patients who have this problem on double miniplate system. The results revealed that the application of two miniplates were more recommendable than single miniplates. When we select resorbable miniplate system, we should consider the type of fractures, post-operative treatment protocol and surgical technique.

Complications Associated with Monocortical Titanium Miniplate used in Rigid Fixation of Mandibular Fractures (하악골 골절의 견고고정에 사용된 monocortical titanium miniplate와 관련된 감염증에 관한 연구)

  • Kim, Young-Kyun;Yeo, Hwan-Ho;Lee, Hyo-Bin;Kim, Kyung-Weon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.4
    • /
    • pp.438-446
    • /
    • 1994
  • Eighty-nine patients with mandibular fracture were treated by open reduction and internal fixation using the monocortical titanium miniplate(Leibinger Co.). Postsurgical intermaxillary fixation was carried out for 2 to 18 days according to the patient's status. Seven patients developed infections postoperatively(7.9%). Five patients were favorably treated by incision and drainage and/or saucerization. But two patients were not controlled by early surgical intervention and should have been followed by plate removal, saucerization and secondary reconstruction including the bone graft. This article reports the postoperative infection associated with miniplate fixation of mandibular fractures and discuss the incidence, cause, treatment and prognosis with careful case analyses.

  • PDF

FIXATION OF FRACTURED ORBITAL BONE USING AUTOGENOUS CALVARIAL BONE PLATE (자가 두개골 플레이트(autogenous calvarial bone plate)를 이용한 골절된 안와골의 고정)

  • Yang, Yun-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.4
    • /
    • pp.377-382
    • /
    • 1997
  • Miniplate의 사용은 Champy등의 보고 이후 구강외과 영역에 있어서 외상 혹은 악교정수술등 많은 분야에 이용되기 시작했다. 전통적인 악간고정 방법에 비해 miniplate는 사용하기 쉽고, 정확한 해부학적 정복 및 고정을 가능케 하며 결과적으로 빠른 치유를 가능케 한다는 장점들을 갖고 있다. 그러나 감염, wound dehiscence, 부식, 나사의 헐거워짐, 주위조직의 변색 그리고 stress shielding effect등의 후유증들이 보고되어 왔으며 가장 무해한 금속이라고 알려진 titanium 또한 주위조직 및 lung, spleen, liver 그리고 kidney 등과 같은 조직으로 metal을 전이시키는 것으로 보고되고 있다. 특히 안와골 주변과 같은 상부 연조직이 얇은 곳에 miniplate를 사용할 경우 miniplate가 만져지거나 보일수도 있다는 점이 보고되었으며 따라서 술후 사용되었던 miniplate를 제거 해야만 할 것인가가 또한 주된 관심사로 보고되고 있다. 이에 저자는 이러한 금속성 miniplate의 단점을 개선하고자 자가 두개골을 이용한 플레이트를 고안하였다. '자가 두개골 플레이트'의 적응증은, enophthalmos 개선의 목적으로 두개골을 채취해 임플란트로 사용하는, enophthalmos를 동반한 관골 및 안와골의 복합골절환자에 있어 두개골의 추가채취가 가능한 경우가 될 수 있겠다. 자가 두개골을 이용해 플레이트를 고안하려고 본 증례에서의 시도는 구강외과 영역에 있어서 자가 두개골이 골편이 고정재료로도 쓰일 수 있다는 가능성을 보여주었다는 점에서 의미가 있다고 저자는 생각한다.

  • PDF

A STUDY FOR THE NATURE OF PIGMENTATION ADJACENT TO TITANIUM MINIPLATE OSTEOSYNTHESIS (티타늄 소강판 주위조직에 발생한 색소침착의 성질에 관한 연구)

  • Weon, Dong-Whan;Joo, Hyun-Ho;Lee, Sang-Hwy;Kim, Il-Hyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.1
    • /
    • pp.25-31
    • /
    • 2001
  • The titanium miniplate osteosynthesis system has been used for fixation of bone fragments in the maxillofacial areas due to easy manipulation and even has been proposed for unnecessity of miniplate removal because of the biocompatibility and the corrosion resistance. But recently, there have been some suggestions for its removal, on the basis of findings that there have been pigmentations around the adjacent tissues during miniplate removal procedure and they are the depositions of metal particles. Purposes of this study are to ascertain the presence and nature of pigmentation observed within tissues adjacent to titanium miniplate, and to suggest possible causes of it. We could observe the black pigmentation during miniplate removal procedure for recent about 1.5 year. Pigmented tissues were stained with hematoxylin-eosin(H-E) for light microscophic(LM) examination to investigate the black pigmentations and the histomorphology around them. The scanning electron microscopy(SEM) with energy dispersive X-ray(EDX) analysis was used to examine the ultrastructural nature of pigmentations. Many metal particles with variable sizes and shapes were seen in the connective tissue by SEM and were identified as titanium by EDX.

  • PDF

CASE REPORTS OF MULTIPLE FACIAL BONE FRACTURE TREATED BY THE USE OF MINIPLATE OSTEOSYNTHESIS (MINIPLATE를 이용한 다발성 안면골 골절의 치험례)

  • Lee, Dong-Keun;Yim, Chang-Joon;Yang, Hee-Chang
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.2
    • /
    • pp.47-52
    • /
    • 1989
  • There were increased number of maxillofacial trauma in recent years accompanied by the change in the type and the severity of the injury thus it was necessary to set up new therapeutic concepts. Among many fixation methods, miniplate osteosynthesis, compression osteosynthesis, wire osteosynthesis and so forth were considered. In this paper we are reporting case of the multiple facial bone fracture, which mainly treated with miniplate osteosynthesis and the additionally used craniofacial suspension wire and transpaltal wire. It was concluded that miniplate osteosynthesis was useful in multiple facial bone fractures.

  • PDF

A Newly Designed Miniplate Staple for High Tibial Osteotomy (근위골절술을 위한 Staple 설계)

  • Mun, Mu-Seong;Bae, Dae-Kyung
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.19-22
    • /
    • 1995
  • A biomechanical study was made to demonstrate the superior mechanical performance of the newly designed Miniplate staple to the conventional Coventry staple in high tibial osteotomy(HTO). Using twenty fresh porcine tibiae, the fixational strengh of the two different types of staple in HTO was compared. To minimize the error due to the specimen-to-specimen individuality, the bone mineral density of the tibiae was measured with a bone densitometry (Dual photon absorptionometer, Luner, USA) and those with $0.8\;{\sim}\;1.2\;gm/cm^2$ at the proximal tibia was used in the biomechanical test. Testing was performed on a material testing system (Autogram ET-5, Shimatzu, Japan) with aid of a commercial data processor (IBM 80386/ ASYST). Using two differant loading modes, 'pull-out' and 'push-out', the maximum resistant force required to release the staple from the substrate bone was recorded. In the pull-out test, ten non-osteotomized specimens were used and the staple was pullout by subjecting an axial tension on the head of the staple inserted. While in the pull-out test where ten tibiae osteotomized in the usual way of HTO were used, the staple was not directly loaded. In this testing, as a mimic condition of the natural knee, the distal part of the specimen tibia was pushed horizontally in order for the staple to be pulled out while the proximal tibia was fixed. The pull-out strength of Coventry staple and miniplate staple were found to be $27.88\;{\pm}\;5.12\;kgf$ and $182.47\;{\pm}\;32.75\;kgf$, respectively. The push-out strength of Coventry staple and miniplate staple were $18.40\;{\pm}\;4.47\;kgf$ and $119.95\;{\pm}\;19.06\;kgf$, respectively. The result revealed that miniplate staple had the pull-out/ push-out strength at least fivetimes higher than Coventry staple. Based on the measured data, it was believed that the newly designed miniplate staple could provide much better postoperative fixation in HTO. The postoerative application of long leg casting may not be needed after HTO surgery.

  • PDF

The experimental study of early loading on the Miniplate in the beagle dog (성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구)

  • Chung, Yong-Koo;Lee, Young-Jun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.307-317
    • /
    • 2003
  • Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.

ORTHODONTIC TREATMENT OF AN IMPACTED MANDIBULAR FIRST MOLAR USING MINIPLATE AS A SKELETAL ANCHORAGE: A CASE REPORT (Miniplate를 골격성 고정원으로 이용한 매복된 하악 제1대구치의 교정치료 증례)

  • Jang, Yoon-Hyoung;Kim, Eun-Young;Kim, Kwang-Chul;Park, Jae-Hong;Lee, Baek-Soo;Choi, Sung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.2
    • /
    • pp.246-251
    • /
    • 2010
  • Impactions can occur because of malpositioning of the tooth bud or obstruction in the path of eruption. However, the exact mechanism is still unknown. The impaction of mandibular first molar is rare with prevalence rates of 0.01~0.25%, but it is important to deimpact the tooth as soon as possible to avoid complications such as dental caries, root resorption, and periodontal problems on the adjacent teeth. Several biomechanical strategies have been proposed for uprighting mesially tipped mandibular first molars. However, most of these have had problems with movement of the anchorage unit because of the reciprocal force. The recent development of skeletal anchorage system(SAS) allows direct application of precise force systems to the target tooth or segment, producing efficient tooth movement in a short time. In this case, an impacted mandibular left first molar with dilacerated roots was treated with a miniplate, which provided skeletal anchorage to upright the tooth. The miniplate was installed in the mandibular ramus, and 10 months after the application of orthodontic force, the impacted tooth was exposed in the oral cavity and uprighted. At this point, the mandibular left first molar was included in the orthodontic appliance with fixed mechanotherapy, the tooth could achieve a normal occlusion. Therefore, the use of SAS simplified the orthodontic procedures and reduced the orthodontic treatment period, and had few side effects.