• Title/Summary/Keyword: minimum required capacity

Search Result 136, Processing Time 0.029 seconds

Minimum Thickness of Long-Span RC Deck Slabs for 2-girder Bridges Designed by 80 MPa Concrete (80 MPa급 고강도 콘크리트를 활용한 2거더교 RC 장지간 바닥판의 최소두께)

  • Bae, Jae-Hyun;Yoo, Dong-Min;Hwang, Hoon-Hee;Kim, Sung-Tae
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.97-103
    • /
    • 2014
  • To ensure durability and light weight of bridges, high-strength concrete is required for long-span deck slabs. Such a technology eventually extends the life of bridges and improves the economic efficiency. The results of this study suggests a formula for calculating the minimum thickness of long-span deck slabs built with high strength concrete. The minimum thickness is proposed based on the limit states indicated in the CEB-FIP Model Code and the Korean Highway Bridge Design Code(limit state design). The design compressive strength of concrete used for the study is 80MPa. Moreover, the required thickness for satisfying the flexural capacity and limiting deflection is estimated considering the limit state load combination. The formula for minimum thickness of deck slabs is proposed considering the ultimate limit state(ULS) and the serviceability limit state(SLS) of bridges, and by comparing the Korean Highway Bridge Design Code and similar previous studies. According to the research finding, the minimum thickness of long-span deck slab is more influenced by deflection limit than flexural capacity.

Minimum Thickness of Long Span RC Deck Slabs for Composite 2-girder Bridges Designed by KL-510 Load Model (KL-510 하중모형을 적용한 강합성 2거더교 RC 장지간 바닥판의 최소두께)

  • Park, Woo-Jin;Hwang, Hoon-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.72-78
    • /
    • 2014
  • The minimum thickness of long-span deck slab is proposed by checking the limit state according to the Korean highway bridge design code(limit state design). Both minimizing thickness and ensuring safety of deck slab are important design factors to increase a competitive price of the long span deck slabs. The required thicknesses for satisfying flexural capacity, preventing punching shear failure and limiting deflection were calculated by considering KL-510 load model which has increased total load compared to DB 24 from 432 kN to 510 kN. The results of the required thickness for various limit states were compared to propose the minimum thickness as a function of span length of deck slabs. The proposed minimum thickness is influenced by satisfying flexural capacity and limiting deflection. It turns out to be similar compared to the results of the previous study by ultimate strength design method even if the live load model was increased in total weights.

Seismic Performance Evaluation According to Rotation Capacity of Connections for Intermediate Steel Moment Frames - I. Performance Evaluation (접합부 회전성능에 따른 중간 철골 모멘트 골조의 내진 성능 평가 - I 성능평가)

  • Moon, Ki Hoon;Han, Sang Whan;Ha, Seung Jin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.95-103
    • /
    • 2014
  • The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediate steel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysis method, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance has not been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and the seismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluation method presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismic performance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the design parameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developed for evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfies the rotation capacity of 0.02 radian.

Comparative analysis of the minimum capacity of an ice-on-coil thermal storage system for various operation strategies (관외 빙착형 빙축열시스템의 운전방식에 따른 최소용량 비교)

  • 이대영;정성훈;강병하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.401-413
    • /
    • 1999
  • An ice storage cooling facility with cooling capacity of 150㎾ has been constructed for the purpose of developing optimal design and control strategy for an ice storage system. As the first step to this purpose, a computer program has been developed to simulate the operation of the ice storage system and examined precisely by comparing the results with those measured from the test facility. With the simulation program verified from the comparison, a design procedure has been developed to determine the minimum capacity required for each operation strategy available commercially. It is shown that the minimum sizes of the chiller and the storage tank are strongly dependent on the control strategy, i.e., chiller priority or storage priority, but less affected by the arrangement method, i.e., chiller upstream or chiller downstream.

  • PDF

Time Switching-based Analog Network Coding for Maximizing the Minimum Required Secrecy Capacity in Energy Harvesting Networks (에너지 하베스팅 네트워크에서 최소 요구 보안 용량을 최대화하기 위한 시간 전환 기반의 아날로그 네트워크 코딩)

  • Lee, Kisong;Choi, Hyun-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.11
    • /
    • pp.2022-2028
    • /
    • 2017
  • Recently, the energy shortage of sensors and the leakage of private information are considered as serious problems as the number of sensors is increasing due to the technological advance in Internet-of-Things. RF energy harvesting, in which sensors collect energy from external RF signals, and physical layer security become increasingly important to solve these problems. In this paper, we propose a time switching-based network analog coding for improving information security in wireless networks where the relay can harvest energy from source signals. We formulate 2-hop relay networks where an eavesdropper tries to overhear source signals, and find an optimal time switching ratio for maximizing the minimum required secrecy capacity using mathematical analysis. Through simulations under various environments, it is shown that the proposed scheme improves the minimum required secrecy capacity significantly, compared to the conventional scheme.

Assessment of Code Requirments on Minimum Shear Reinforcement in High-Strength RC Beams (RC 보의 강도증진에 따른 최소전단철근 규준의 적합성 평가에 관한 연구)

  • 윤영수;원종필;장일영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.289-294
    • /
    • 1996
  • This paper persents the assessment of the minimum shear reinforcement requirements in normal, medium and high-strength reinforced concrete beams. Twelve shear tests were conducted on full-scale beam specimens having design concrete compressive strengths of 35, 70 and 100 MPa. Different amounts of minimum shear reinfrocement were investigated, including the amounts required by Korean Concrete Standard (KCI88), JCI86, ACI89 (revised 1992) and CSA94 standard. The performance of the different amounts of shear reinforcement are discussed in terms of the shear capacity, the ductility and the crack control at service load levels. An assessment of code provisions for minimum shear reinforcememt, and the prediction and comparison of the ultimate shear capacity are also presented.

  • PDF

Optimal Location of Facilities with Upper and tower Capacity Hounds (용량의 상한과 하한이 주어진 설비의 최적 입지 선정)

  • 차동완;민대환;윤문길
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.8 no.1
    • /
    • pp.19-26
    • /
    • 1983
  • This paper deals with the problem of locating facilities with upper and lower capacity bounds in a single level physical distribution system at minimum total costs. Several known schemes for location problems with upper capacity bounds only are successfully extended to our case and then implemented into our branch ana bound solution procedure. Computational experiments with twelve test problems suggest the effectiveness of our approach by showing that only a small amount of additional computation is required for our problem as compared to that for the problems with upper capacity bounds.

  • PDF

Design of Lateral Load Resisting System using Nonlinear Static Analysis (비선형 정적해석을 통한 횡저항 시스템의 보유성능 평가 및 설계방안 연구)

  • Song, Jin-Gyu;Kim, Geon-Woo;Jung, Sung-Jin;Song, Young-Hoon;Lee, Seung-Chang
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.1 s.47
    • /
    • pp.9-16
    • /
    • 2006
  • The design practice of the lateral resisting system has been traditionally dependent on the experience and know-how of a structural engineer. And the method to reflect the evaluation results of building's capacity on design process doesn't exist. The proposal of a rational design of the lateral load resisting system is based on the available full capacity $(R_{ac})$ of a building and the minimum required capacity $(R_{code})$ suggested in the code. This study suggests thai nonlinear static analysis, which is the estimation of the lateral capacity with the pushover analysis, be included in the existing design procedure of the structure. After finishing the basic structural design, the lateral resisting capacity ol a building is estimated. At the phase of nonlinear static analysis, pushover analysis is peformed to define the fully yielded baseshear $(V_Y)$. When the design wind baseshear $(V_{wind})$ is bigger than the design seismic baseshear $(V_D)$, the value is checked to determine whether or not it is smaller than the $V_Y$. After confirming that it is smaller, the $R_{ac}$ of the structure is computed. If the $V_D$ is bigger at first, only the $R_{ac}$ is computed. When the value of the estimation shows remarkable differences with the $R_{code}$, repetition of the design modification is needed for those approximate to the $R_{code}$. Application of the proposed design procedure to 2-D steel braced RC buildings has proven to be efficient.

A Model for Determining the Minimum Number of High Speed Exits and Their Locations for Airports (고속탈출유도로 최소 갯수 및 위치 결정 모형)

  • 김병종
    • Journal of Korean Society of Transportation
    • /
    • v.13 no.3
    • /
    • pp.53-65
    • /
    • 1995
  • Proposed are model and its solution algorithm for determining the minimum number of high speed exits and their locations. While the previous researches on exit location aimed to minimize the average runway occuancy time (ROT) of an aircraft mix, the proposed approach is to find the minimum number of exits required to meet maximum allowable ROT. The rationale behind the approach is that the capacity of a runway increases as the ROT decreases down to some value, but not any more even though the ROT keep decreasing below the value. Hence, a maximum allowable ROT might be set up without declining the capacity. The problem is transformed into a shortest path problem on a specially constructed network and Dijkstra's labeling algorithms is employed to solve the problem A hypothetical example is provided to illustrate how the algorithms solves the problem.

  • PDF

Minimum shear reinforcement ratio of prestressed concrete members for safe design

  • Park, Min-Kook;Lee, Deuck Hang;Ju, Hyunjin;Hwang, Jin-Ha;Choi, Seung-Ho;Kim, Kang Su
    • Structural Engineering and Mechanics
    • /
    • v.56 no.2
    • /
    • pp.317-340
    • /
    • 2015
  • Design codes have specified the minimum shear reinforcement requirement for reinforced concrete (RC) and prestressed concrete (PSC) members to prevent brittle and premature shear failure. They are, however, very different from one another, and particularly, ACI318 code allows the required minimum shear reinforcement to be reduced in PSC members, compared to that in RC members, by specifying the additional equation for PSC members whose basis is not clear. In this paper, the minimum shear reinforcement ratio for PSC members was proposed, which can provide a sufficient reserved shear strength and deformation capacity. The proposed equation was also verified by the test results of PSC specimens lightly reinforced in shear, comparing to design codes and other proposed equations from previous studies.