• Title/Summary/Keyword: minimize time-delay

Search Result 279, Processing Time 0.03 seconds

Development of Delay Compensator for Network Based Real-time Control Systems (네트워크 기반 실시간 제어 시스템을 위한 지연 보상기 개발)

  • Kim, Seung-Yong;Kim, Hong-Ryeol;Kim, Dae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.82-85
    • /
    • 2004
  • This paper proposes the development of delay compensator to minimize performance degradation caused by time delays in network-based real-time control systems. The delay compensator uses the time-stamp method as a direct delay measuring method to measure time delays generated between network nodes. The delay compensator predicts the network time delays of next period in the views point of time delays and minimizes performance degradation from network through considering predicted time delays. Control output considering network time delays is generated by the defuzzification of probable time delays of next period. The time delays considered in the delay compensator are modeled by using a timed Petri net model. The proposed delay prediction mechanism for the delay compensator is evaluated through some simulation tests by measuring deviation of the predicted delays from simulated delays.

  • PDF

A model-based adaptive control method for real-time hybrid simulation

  • Xizhan Ning;Wei Huang;Guoshan Xu;Zhen Wang;Lichang Zheng
    • Smart Structures and Systems
    • /
    • v.31 no.5
    • /
    • pp.437-454
    • /
    • 2023
  • Real-time hybrid simulation (RTHS), which has the advantages of a substructure pseudo-dynamic test, is widely used to investigate the rate-dependent mechanical response of structures under earthquake excitation. However, time delay in RTHS can cause inaccurate results and experimental instabilities. Thus, this study proposes a model-based adaptive control strategy using a Kalman filter (KF) to minimize the time delay and improve RTHS stability and accuracy. In this method, the adaptive control strategy consists of three parts-a feedforward controller based on the discrete inverse model of a servohydraulic actuator and physical specimen, a parameter estimator using the KF, and a feedback controller. The KF with the feedforward controller can significantly reduce the variable time delay due to its fast convergence and high sensitivity to the error between the desired displacement and the measured one. The feedback control can remedy the residual time delay and minimize the method's dependence on the inverse model, thereby improving the robustness of the proposed control method. The tracking performance and parametric studies are conducted using the benchmark problem in RTHS. The results reveal that better tracking performance can be obtained, and the KF's initial settings have limited influence on the proposed strategy. Virtual RTHSs are conducted with linear and nonlinear physical substructures, respectively, and the results indicate brilliant tracking performance and superb robustness of the proposed method.

Position Control of Linear Actuator with Time Delay Using the Smith Predictor

  • Kang, Seung-Won;Park, Gi-sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.68.1-68
    • /
    • 2001
  • This paper discusses tracking position control of linear actuator that has a time delay. The time delay happens when the process reads the sensor data and sends the control input to the plant located at a remote site in distributed control system. In this thesis, the time delay between the linear actuator and the discrete PID controller has constant value due to buffer device so the time delay can be modeled by Pade approximation but the large position error of the linear actuator is generated by the time delay. Therefore, the Smith predictor is used for tracking position control of the linear actuator with the time delay in order to minimize the effect of the time delay. The experimental and simulation results show that the ...

  • PDF

Time-Domain Numerical Investigation of Ring Resonator Optical Delay Devices

  • Chung, Youngchul
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.441-446
    • /
    • 2013
  • A split-step time-domain model for the analysis of pulse delay characteristics through ring resonator all-pass filters (APF's) is developed and its accuracy is checked. The dependence of the delay time and pulse distortion on the coupling ratios is investigated using the model. It is observed that the bandwidth of the APF's needs to be wide enough to minimize the pulse distortion.

Non-fragile guaranteed cost control of delayed descriptor systems (시간지연 특이시스템의 비약성 보장비용 제어)

  • Kim, Jong-Hae
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.246-248
    • /
    • 2006
  • This paper is concerned with non-fragile guaranteed cost state feedback controller design algorithm for descriptor systems with time-varying delay and static state feedback controller with multiplicative uncertainty. The considered uncertainties are norm-bounded and time delay is time-varying. Under the condition of controller gain variations, conditions for the existence of controller satisfying asymptotic stability and non-fragility and controller design method are derived via LMI approach. Moreover, the measure of non-fragility and the upper bound to minimize guaranteed cost function are given.

  • PDF

Adaptive Multimedia Synchronization Using Waiting Time (대기시간을 이용한 적응형 멀티미디어 동기화 기법)

  • Lee, Gi-Seong;Lee, Geun-Wang;Lee, Jong-Chan;O, Hae-Seok
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.2S
    • /
    • pp.649-655
    • /
    • 2000
  • Real-time application programs have constraints which need to be met between media-data. These constraints represents the delay time ad quality of service between media-data to be presented. In order to efficiently describe the delay time and quality of service, a new synchronization mechanism is needed. Proposed paper is a dynamic synchronization that minimized the effects of adaptive transmission delay time. That is, the method meets the requirements of synchronization between media-dat by handling dynamically the adaptive waiting time resulted from variations of delay time. In addition, the mechanism has interval adjustment using maximum delay jitter time. This paper decreases the data loss resulted from variation of delay time and from loss time of media-data by means of applying delay jitter in order to deal with synchronization interval adjustment. Plus, the mechanism adaptively manages the waiting time of smoothing buffer, which leads to minimize the gap from the variation of delay time. The proposed paper is suitable to the system which requires the guarantee of high quality of service and mechanism improves quality of services such as decrease of loss rate, increase of playout rate.

  • PDF

Pre- and In-Hospital Delay in Treatment and in-Hospital Mortality after Acute Myocardial Infarction

  • An, Kyuneh;Koh, Bongyeun
    • Journal of Korean Academy of Nursing
    • /
    • v.33 no.8
    • /
    • pp.1153-1160
    • /
    • 2003
  • Purpose. 1) To identify the time taken from symptom onset to the arrival at the hospital (pre-hospital delay time) and time taken from the arrival at the hospital to the initiation of the major treatment (in-hospital delay time) 2) to examine whether rapid treatment results in lower mortality. 3) to examine whether the pre- and in-hospital delay time can independently predict in-hospital mortality. Methods. A retrospective study with 586 consecutive AMI patients was conducted. Results. Pre-hospital delay time was 5.25 (SD=10.36), and in-hospital delay time was 1.10 (SD=1.00) hours for the thrombolytic therapy and 50.24 (SD=121.18) hours for the percutaneous transluminal coronary angio-plasty (PTCA). In-hospital mortality was the highest when the patients were treated between 4 to 48 hours after symptom onset using PTCA (p=.02), and when treated between 30 minutes and one hour after hospital arrival using thrombolytics (p=.01). Using a hierarchical logistic regression model, the pre- and in-hospital delay times did not predict the in-hospital mortality. Conclusion. Pre- and in-hospital delay times need to be decreased to meet the desirable therapeutic time window. Thrombolytics should be given within 30 minutes after arrival at the hospital, and PTCA should be initiated within 4 hours after symptom onset to minimize in-hospital mortality of AMI patients.

Optimal Maintenance Policy for Fishing Vessel Equipment Using Delay Time Analysis

  • Jung, Gi-Mun;Kwon, Young-Sub;Anand Pillay;Jin Wang
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2000.11a
    • /
    • pp.329-333
    • /
    • 2000
  • Delay time analysis is a pragmatic mathematical concept readily embraced by engineers which has been developed as a means to model maintenance decision problem. This paper considers an inspection period using delay time analysis for fishing vessel equipment. We assume that delay time distribution is Weibull and inspections are perfect. In this paper, we determine the optimal inspection period which minimize the expected downtime per unit time.

  • PDF

Downtime Optimization for Fishing Vessel Equipment Using Delay Time Analysis

  • Jung, Gi-Mun;Kwon, Young-Sub;Anand Pillay;Jin Wang
    • International Journal of Reliability and Applications
    • /
    • v.2 no.2
    • /
    • pp.99-105
    • /
    • 2001
  • Delay time analysis is a pragmatic mathematical concept readily embraced by engineers which has been developed as a means to model maintenance decision problem. This paper considers an inspection period using delay time analysis for fishing vessel equipment. We assume that delay time has a Weibull distribution. In this paper, we determine the optimal inspection period which minimize the expected downtime per unit time. Explicit solutions for the optimal inspection are presented for illustrative purposes.

  • PDF

Distributed generation protection technique to minimize the outage section (정전구간 최소화를 위한 분산전원 보호)

  • Kang, Yong-Cheol;Lee, Byung-Eun;Jin, Enshu;Hwang, Tae-Keun;Lee, Ji-Hoon;Cha, Sun-Hee;Park, Jong-Min;Zheng, Tai-Ying
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.450-452
    • /
    • 2005
  • Distributed generation (DG) plays an important role in the power system nowadays. Over-current relay, widely used in the DG protection, causes a wide outage section and long time delay. This paper proposes a DG protection technique to minimize the outage section. The proposed method uses three directional over-current relays with time delay, which are connected to the point of common coupling. The method can minimize the outage section.

  • PDF