• Title/Summary/Keyword: minimal generator

Search Result 51, Processing Time 0.056 seconds

Parametric Study of a Fixed-blade Runner in an Ultra-low-head Gate Turbine

  • Mohamed Murshid Shamsuddeen;Duc Anh Nguyen;Jin-Hyuk Kim
    • New & Renewable Energy
    • /
    • v.20 no.1
    • /
    • pp.116-125
    • /
    • 2024
  • Ultra-low-head is an unexplored classification among the sites in which hydroelectric power can be produced. This is typically owing to the low power output and the economic value of the turbines available in this segment. A turbine capable of operating in an ultra-low-head condition without the need of a dam to produce electricity is developed in this study. A gate structure installed at a shallow water channel acting as a weir generates artificial head for the turbine mounted on the gate to produce power. The turbine and generator are designed to be compact and submersible for an efficient and silent operation. The gate angle is adjustable to operate the turbine at varying flow rates. The turbine is designed and tested using computational fluid dynamics tools prior to manufacturing and experimental studies. A parametric study of the runner blade parameters is conducted to obtain the most efficient blade design with minimal hydraulic losses. These parameters include the runner stagger and runner leading edge flow angles. The selected runner design showed improved hydraulic characteristics of the turbine to operate in an ultra-low-head site with minimal losses.

An Implementation of The Position Pattern Generating Algorithm with Minimal Locomotion Time for Single-Axis Linear Machine Drive System (단축 선형 전동기 구동을 위한 최단시간 이동 방식의 위치 패턴 발생 알고리즘의 구현)

  • Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.221-233
    • /
    • 2007
  • In this paper, a simple but effective position profile generation algorithm for single axis high dynamic linear machine drive system is presented. In the recent industrial application fields like as LCD/PDP and semiconductor factory, requirements for the high performance positioning system with optimal position profile generator are highly increased to reduce the overall processing time. There might be various solutions for position profile generating algorithm according to the application type. A square-wave Impact quantity(Jerk) based algorithm with minimal locomotion time is argued in this paper to minimize the total time of one movement under some specific constrains such as maximum speed limit and maximum acceleration limit. In order to reduce the calculation efforts and satisfy the minimal locomotion time condition, the time variants representing each profile sector and a simple condition comparison algorithm are adopted. Also, the actual implementation method for profile generation algorithm and it's real performance results are presented through commercial linear machine drive system.

CONSTRUCTION OF TWO- OR THREE-WEIGHT BINARY LINEAR CODES FROM VASIL'EV CODES

  • Hyun, Jong Yoon;Kim, Jaeseon
    • Journal of the Korean Mathematical Society
    • /
    • v.58 no.1
    • /
    • pp.29-44
    • /
    • 2021
  • The set D of column vectors of a generator matrix of a linear code is called a defining set of the linear code. In this paper we consider the problem of constructing few-weight (mainly two- or three-weight) linear codes from defining sets. It can be easily seen that we obtain an one-weight code when we take a defining set to be the nonzero codewords of a linear code. Therefore we have to choose a defining set from a non-linear code to obtain two- or three-weight codes, and we face the problem that the constructed code contains many weights. To overcome this difficulty, we employ the linear codes of the following form: Let D be a subset of ��2n, and W (resp. V ) be a subspace of ��2 (resp. ��2n). We define the linear code ��D(W; V ) with defining set D and restricted to W, V by $${\mathcal{C}}_D(W;V )=\{(s+u{\cdot}x)_{x{\in}D^{\ast}}|s{\in}W,u{\in}V\}$$. We obtain two- or three-weight codes by taking D to be a Vasil'ev code of length n = 2m - 1(m ≥ 3) and a suitable choices of W. We do the same job for D being the complement of a Vasil'ev code. The constructed few-weight codes share some nice properties. Some of them are optimal in the sense that they attain either the Griesmer bound or the Grey-Rankin bound. Most of them are minimal codes which, in turn, have an application in secret sharing schemes. Finally we obtain an infinite family of minimal codes for which the sufficient condition of Ashikhmin and Barg does not hold.

Performance Variation of a Combined Cycle Power Plant by Coolant Pre-cooling and Fuel Pre-heating (냉각공기 예냉각과 연료예열에 의한 복합발전 시스템의 성능변화)

  • Kwon, Ik-Hwan;Kang, Do-Won;Kim, Tong-Seop;Kim, Jae-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.3
    • /
    • pp.57-63
    • /
    • 2012
  • Effects of coolant pre-cooling and fuel pre-heating on the performance of a combined cycle using a F-class gas turbine were investigated. Coolant pre-cooling results in an increase of power output but a decrease in efficiency. Performance variation due to the fuel pre-heating depends on the location of the heat source for the pre-heating in the bottoming cycle (heat recovery steam generator). It was demonstrated that a careful selection of the heat source location would enhance efficiency with a minimal power penalty. The effect of combining the coolant pre-cooling and fuel pre-heating was also investigated. It was found that a favorable combination would yield power augmentation, while efficiency remains close to the reference value.

Fault Immune Pico-Hydro Powered Base Station of Remote Telecommunication Tower

  • Verma, Vishal;Pant, Peeyush;Singh, Bhim
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1612-1620
    • /
    • 2016
  • This paper presents the dynamic excitation control of a siphon-turbine coupled pico-hydro powered cage rotor induction generator and load matching for off-grid electricity generation. Through the proposed dual-role of the current-controlled voltage source converter (VSC), acting as static synchronous compensator and load controller, real and reactive power are dynamically controlled in a decoupled manner with a self supported DC-bus. The proposed scheme entails minimal computation for ensuring the rated (set) capacity of real power. The scheme also exhibits fault immunity for protection, thus enabling the effective handling of constant power electrical loads presented by base telecom station towers in remote locations. The performance of the system is evaluated under MATLAB/Simulink and is experimented through a developed hardware prototype. Simulation and experimental results show close conformity and validate the effectiveness of the proposed scheme.

ALGEBRAS WITH A NILPOTENT GENERATOR OVER ℤp2

  • Woo, Sung-Sik
    • Bulletin of the Korean Mathematical Society
    • /
    • v.43 no.3
    • /
    • pp.487-497
    • /
    • 2006
  • The purpose of this paper is to describe the structure of the rings $\mathbb{Z}_{p^2}[X]/({\alpha}(X))$ with ${\alpha}(X)$ a monic polynomial and $\={X}^{\kappa}=0$ for some nonnegative integer ${\kappa}$. Especially we will see that any ideal of such rings can be generated by at most two elements of the special form and we will find the 'minimal' set of generators of the ideals. We indicate how to identify the isomorphism types of the ideals as $\mathbb{Z}_{p^2}-modules$ by finding the isomorphism types of the ideals of some particular ring. Also we will find the annihilators of the ideals by finding the most 'economical' way of annihilating the generators of the ideal.

Design of an Electrical Pulse Generator for the Multi-parameter Neuromuscular Stimulation System (다변수 근신경 자극 시스템을 위한 전기자극 펄스 발생기의 설계)

  • Ko, K.R.;Kim, H.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.165-166
    • /
    • 1998
  • A multi-parameter neuro muscular electrical simulator (NMES) system was developed to be used to find the optimal parameter condition in obtaining maximum muscle power and minimal fatigue. Since the performance of NMES is mainly determined by the characteristic of its output-stage circuit, we implemented 3 different circuits and compared output characteristics of them. Three amplifier circuits are; 1) a resonant switching converter, 2) a linear amplifier with a transformer, and 3) a step-up DC/DC converter with a high-voltage linear amplifier. Experimental results showed that the step up DC/DC converter with a high-voltage linear amplifier has the best performance.

  • PDF

A Study on the Availability Prediction of Start-up Power Supply in Nuclear Power Plant by FTAMethod (FTA기법에 의한 원전기동전원의 이용율 예측에 관한 연구)

  • Che, Gyu-Shik
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.517-523
    • /
    • 1999
  • The Start-up transformers or on-site stand-by transformers are installed for the start-up and shut-down of generator and emergency status in unclear power plant. The on-site power supply configuration using these transformers must be detemined by considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and benefit of plant. The start-up or stand-by power supply configuration has been determined considering only safety requirements and construction cost up to now in Korea. I study various reliability estimating methods for the prediction of availability, and estimate the unavailability for the start-up power supply system of two 1,000㎿ unclear power plants. I also detemine the reliability and unavailability and unavailavility of equipment, system and configuration using FTA method.

  • PDF

ON THE RATIONAL COHOMOLOGY OF MAPPING SPACES AND THEIR REALIZATION PROBLEM

  • Abdelhadi Zaim
    • Communications of the Korean Mathematical Society
    • /
    • v.38 no.4
    • /
    • pp.1309-1320
    • /
    • 2023
  • Let f : X → Y be a map between simply connected CW-complexes of finite type with X finite. In this paper, we prove that the rational cohomology of mapping spaces map(X, Y ; f) contains a polynomial algebra over a generator of degree N, where N = max{i, πi(Y)⊗ℚ ≠ 0} is an even number. Moreover, we are interested in determining the rational homotopy type of map(𝕊n, ℂPm; f) and we deduce its rational cohomology as a consequence. The paper ends with a brief discussion about the realization problem of mapping spaces.

Distribution of Procymidone in a Small Vinyl House after Application of Smoke Generator (소형 비닐하우스 내에서 훈연처리된 살균제 Procymidone의 분포 특성)

  • Lim, He-Kyoung;Kim, Joung-Han;Cho, Kwang-Yun;Yu, Ju-Hyun
    • Applied Biological Chemistry
    • /
    • v.44 no.1
    • /
    • pp.7-11
    • /
    • 2001
  • The distribution of procymidone in a small vinyl house containing cucumber plants or mimic plants was investigated after application of smoke generator. The deposition of procymidone on glass plate and filter paper was significantly similar to that on cucumber leaves, so that glass plate and filter paper could be substituted for cucumber leaves on deposition studies. The deposition of procymidone was proportional to the horizontally projected area of surface; the deposition on the horizontal surface was maximal, and the deposition was minimal for the perpendicular surface. The amount of deposition on the backside of leaf was less than 5% compared to that on the horizontal surface of leaf. The height of leaf from the floor was not a significant factor influencing on the deposition of procymidone whether leaves were overlapped or not. However, the deposition of procymidone on the overlapped leaves was relatively less than that on the unoverlapped leaves. And the deposition difference depending on the distance between leaves was not observable. Overall, the deposition of procymidone was proportionally increased with the application rate of smoke generator, but the deposition was inversely related to the sum of the total horizontal leaf area of mimic plants and the surface area of floor.

  • PDF