• Title/Summary/Keyword: min-min

Search Result 127,564, Processing Time 0.113 seconds

Effect of Treadmill Training with FES on Walking Velocity, Gait Endurance, and Energy Expenditure Index of Hemiplegia Patients (기능적 전기자극을 적용한 트레드밀 보행 훈련이 편마비 환자의 보행 속도와 보행 지구력, 에너지 소모지수에 미치는 영향)

  • Lee, Hyoung-Soo;Shin, Young-Il;Kim, Myung-Hoon
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.2
    • /
    • pp.7-16
    • /
    • 2003
  • The purpose of this study was to investigate the effect of Treadmill Training with FES(TTF) on walking velocity, gait endurance, and energy expenditure index(EEI) of hemiplegia patients with foot drop. Two subjects with hemiplegia participated in this study. They took walking excercise 5 times per week for 8 weeks. One time excercise spent 30minutes. The theraputic effect was evaluated by how many seconds they needed to walk 10 meters, how far they could walk for 12 minutes, and how much they spent energy in walking for 12 minutes. Two cases were examined before, after 4 week, and after 8 week, walking training. The results of this study are as follows; 1) Walking velocity : Case 1 increased from 0.52m/sec before walking training to 0.83m/sec after 8 weeks. Case 2 increased from 0.58m/sec to 0.92m/sec. 2) Gait endurance : Case 1 increased from 383.23m to 625.53m. Case 2 increased from 410.19m to 693.47m. 3) EEI : For comfortable walking condition, Case 1 decreased from 0.98beats/min to 0.71beats/min, and Case 2 decreased from 0.93beats/min to 0.68beats/min. For maximum walking condition, Case 1 decreased from 0.93beats/min to 0.67beats/min, and Case 2 decreased from 0.91beats/min to 0.61beats/min. The findings suggest that hemiplegia patients can improve their walking velocity, gait endurance and energy expenditure index through TTF.

  • PDF

A Study on Efficient CNU Algorithm for High Speed LDPC decoding in DVB-S2 (DVB-S2 기반 고속 LDPC 복호를 위한 효율적인 CNU 계산방식에 관한 연구)

  • Lim, Byeong-Su;Kim, Min-Hyuk;Jung, Ji-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.1892-1897
    • /
    • 2012
  • In this paper, efficient CNU(Check Node Update) algorithms are analyzed for high speed LDPC decoding in DVB-S2 standard. In aspect to CNU methods, there are some kinds of CNU methods. Among of them, MP (Min Product) method is quite often used in LDPC decoding. However MP needs LUT (Look Up Table) that is critical path in LDPC decoding speed. A new SC-NMS (Self-Corrected Normalized Min-Sum) method is proposed in the paper. NMS needs only normalized scaling factor instead of LUT and compensates the overestimation of MP approximation. In addition, SC method is proposed. It gives a faster convergence toward a decoded codeword. If a message change its sign between two iterations, it is not reliable and to avoid to propagate noisy information, its module is set to 0. The performance of SC-NMS has a little degrade compare to MP by 0.1 dB, however considering computational complexity and decoding speed, SC-NMS algorithm is optimal method for CNU algorithm.

Effect of Aeration Intensity on Simultaneous Nitrification and Denitrification Efficiency in the Submerged Moving Media Biofilm Process (완전침지형 회전매체 생물막 공정에서 포기강도 조절이 동시 질산화/탈질 효율에 미치는 영향)

  • Kim, Jun-myoung;Lee, Sang-min;Lim, Kyeong-ho;Kim, Il-gyou;Kang, Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.3
    • /
    • pp.273-279
    • /
    • 2008
  • Space separation method that use independent reactor for nitrification and other reactor for denitrification has been commonly used for biological nitrogen removal process like $A^2O$ process. However, this method needs large space and complicate pipelines and time separation method such as SBR process have a difficulty in continuous treatment. Thus biological nitrogen removal process which is capable of continuous treatment, easy opeation and space saving is urgently required. In this research, submerged moving media was used for a biofilm process and suspended sludge was used for biological nitrogen removal at the same time. In particular DO environment by controlling air flow rate was investigated for simultaneous nitrification/denitrification. Total nitrogen removal in aeration rate more than $67L/min{\cdot}m^3$ showed 51~53% and rose to 65%, 70% and 78% in $50L/min{\cdot}m^3$, $58L/min{\cdot}m^3$ and $25L/min{\cdot}m^3$ respectively. Total phosphorus removal was very low about 10~20% more than $67L/min{\cdot}m^3$ aeration rates. But total phosphorus removal roses when reduces aeration rate by $58L/min{\cdot}m^3$ low and it showed total phosphorus removal of 72% in aeration rate $25L/min{\cdot}m^3$.

AN EXPERIMENTAL STUDY OF BOND STRENGTH OF GLASS IONOMER LUTING CEMENT UNDER THE FUNCTIONAL LOADS ON THE CROWN (기능 하중 하에서 접착용 Glass Ionomer 시멘트의 결합강도에 대한 비교연구)

  • Jun Joong-Hyun;Kang Woo-Jin;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.225-232
    • /
    • 1992
  • The purpose of this study was to compare the bond strength of the glass ionomer luting cements after the functional loads were applied to the crowns respectively 10 min, 30 min, 1 hr, 24 hrs later after mixing of cements. The conventional (GC Fuji I; GC Int. Co., Japan), water hardening type (Ketac Cem; ESPE, W. Germany) glass ionomer luting cement and C-dent ZPC (Confi-Dental Products Co., U.S.A.) as a control were used. The results of this study were obtained as follows: 1. In the bond strength of GC Fuji I, 24 hr-group was highest and there were no statistically significant differences among 10 min-, 30 min- and 1 hr- groups. 2. l3 the bond strength of Ketac Cem and C-dent ZPC, there was no statistically significant differences among 10 min-, 30 min-, 1 hr- and 24 hr-groups respectively. 3. Comparing the bond strength among cements in 10 min-, 30 min-groups respectively, GC Fuji I was lowest and there was no statistically significant difference between Ketac Cem and C-dent ZPC. 4. The bond strengths between GC Fuji I and Ketac Cem were not significantly different in 1 hr-, 24 hr-group. 5. The bond strengths among 3 types of cements were not significantly different in 24 hr-groups.

  • PDF

Noise Exposure according to the Time Activity Pattern and Duties of Firefighters (소방 공무원의 시간활동 양상과 직무에 따른 소음 노출 특성)

  • Lee, Lim-Kyu;Kang, Tae-Sun;Ham, Seung-Hon;Kim, Jung-In;Yang, Young-Suk;Yoon, Chung-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.2
    • /
    • pp.94-101
    • /
    • 2011
  • Objectives: The purpose of this study is to evaluate the noise exposures of firefighters according to their time-dependent activity patterns. Methods: Personal exposure levels were measured for six days and nights using noise dosimeters; three days and nights for on-duty tasks, the other days and nights for off-duty activities. Results: The total amount of time spent in the workplace was 13,677 min (67%), outside areas 4,833 min (23%), in transit 1,002 min (5%), and other indoor area 807 min (4%) during a working period. However, during off-days they spent 10,858 min (76%) at home, 1,382 min (10%) outdoors, 1,225 min (9%) other indoors, and 493 min (3%) in transit. As a result of individual exposure levels, TWA did not exceed 90 dBA of the occupational exposure limit for the majority of the firefighters, whereas the levels of Lmax were 119 dBA, which were higher than the noise levels of firefighters in USA. Sometimes during dispatching the levels of Lpeak exceeded the ACGIH exposure standard (140 dBC). The Leq levels in transit were higher than the levels in home and other indoors even though the activity time is short. Conclusions: This paper characterized the noise exposure patterns of firefighters in Korea. We suggest that special noise sources, including sirens and speaker phones, should be readjusted to reduce noise exposure.

Monitoring on the Tea with Steaming and Drying Process of Germinated Buckwheat (메밀순의 증숙 및 건조에 따른 침출차 특성 모니터링)

  • 이기동;윤성란;김정옥;허상선;서권일
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.1
    • /
    • pp.212-217
    • /
    • 2004
  • To make the germinated buckwheat tea, soluble solid contents, total flavonoid contents and organoleptic properties were investigated under various steaming time and drying temperature. The optimum condition of soluble solid contents were 6.93 min of steaming time and 73.59$^{\circ}C$ of drying temperature. Total flavonoid contents were maximum under the condition of 5.22 min of steaming time and 79.05$^{\circ}C$ of drying temperature. The optimum condition of overall palatability was 6.00 min of steaming time and 77.33$^{\circ}C$ of drying temperature. The optimum ranges of soluble solid contents, total flavonoid contents and overall palatability of the tea were 5.4∼7.0 min of steaming time and 75∼8$0^{\circ}C$ of drying temperature. The values expected in the optimum ranges were also similar to the experimental values.

Analysis of Working Time of Nurses in Urban Public Health Center Branches in South Korea.: Focused on Nurses for Visiting Health Service and Chronic Disease Management (도시보건지소 간호사의 업무활동 소요시간 분석 - 방문보건 및 만성질환관리를 중심으로 -)

  • June, Kyung-Ja;Kim, Hee-Gerl;Kim, Souk-Young;So, Ae-Young;Sohn, Shin-Young;Park, Eun-Ok
    • Research in Community and Public Health Nursing
    • /
    • v.19 no.4
    • /
    • pp.649-659
    • /
    • 2008
  • Purpose: The purpose of this study is to investigate working time of nurses in urban public health center branch, especially for nurses for visiting health service and chronic disease management. Method: Daily note. which was developed by this research team. was distributed to nurses at 7 urban public health center branches to be filled out them for 2 weeks during 2 month from June 2007 to August 2007. We analyzed 121 daily notes recorded by visiting nurses and 65 daily notes written by chronic disease management nurses were analyzed. Result: The total working time for visiting nurses at urban public health center branches was 589.85 minutes per day on the average. They spent 147.13 min in actual visiting nursing services, 149.36 min in documenting, 66.94 in preparing, 77.69 min in transferring, and 11.84 min in referring. The total working time for chronic disease management nurses at urban public health center branches was 582.92 minutes per day on the average. They spent 148.77 min in actual chronic disease management services, 120.62 min in documenting, 42.46 min in group education, 37.38 in preparing, and 10.38 min in referring. Conclusion: Based on the results of this study, it is recommended to improve documenting systems and to increase community resources linkage were recommended through the results of this study. The results of this study are expected to be used to plan staffing at urban public health center branches in the future.

  • PDF

Poor Fibrinolytic Response on a Single Bout Exercise Intensity and Time in Male Chronic Ischemic Stroke Patient (남성 만성기 허혈성 뇌졸중환자의 운동강도 및 시간에 대한 Poor Fibrinolytic Response)

  • Kang, Dong-Yeon;Lee, Hye-Young;Kim, Kyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.4
    • /
    • pp.224-231
    • /
    • 2013
  • Purpose: The purpose of this case study was to investigate three poor fibrinolytic responders with chronic ischemic stroke to acute exercise intensity and time. Methods: Three ischemic stroke patients (male) from the stroke center located at Busan metropolitan area in Republic of Korea volunteered at this study. They performed two single session exercises that were a VO2peak test and a single bout treadmill walking (70-75%HRpeak, 30 min, 50min). Fasting blood samples for determination of tissue Plasminogen Activator (tPA) and Plasminogen Activator Inhibitor-1 (PAI-1) were obtained before, immediately after, 30min after acute exercise. SPSS 12.0 was used for analyzing of data and computing mean and standard deviation, and change rate was conducted between times. Results: In fibrinolytic activity according to the intensity and time of acute exercise, tPA change increased steadily during the recovery stage after the VO2peak in the cases, but PAI-1 activity showed different patterns among the cases. In a single bout treadmill walking (70-75%HRpeak, 30 min, 50min), tPA change increased between 30min and 50min. Conclusion: In conclusion, these results suggest that the exercise prescription for poor fibrinolytic responder with three male chronic ischemic stroke patients without motor disability recommend at 70-75%HRpeak, over 30min.

Influence of CT Reconstruction on Spatial Resolution (CT 영상 재구성의 공간분해능에 대한 영향)

  • Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.85-91
    • /
    • 2018
  • Computed tomography, which obtains section images from reconstruction process using projection images, has been applied to various fields. The spatial resolution of the reconstructed image depends on the device used in CT system, the object, and the reconstruction process. In this paper, we investigates the effect of the number of projection images and the pixel size of the detector on the spatial resolution of the reconstructed image under the parallel beam geometry. The reconstruction program was written in Visual C++, and the matrix size of the reconstructed image was $512{\times}512$. The numerical bar phantom was constructed and the Min-Max method was introduced to evaluate the spatial resolution on the reconstructed image. When the number of projections used in reconstruction process was small, artifact like streak appeared and Min-Max was also low. The Min-Max showed upper saturation when the number of projections is increased. If the pixel size of the detector is reduced to 50% of the pixel size of the reconstructed image, the reconstructed image was perfectly recovered as the original phantom and the Min-Max decreased as increasing the detector pixel size. This study will be useful in determining the detector and the accuracy of rotation stage needed to achieve the spatial resolution required in the CT system.

Effect of Electrolyte Flow Rates on the Performance of Vanadium Redox Flow Battery (바나듐레독스흐름전지 전해질 유량에 따른 성능변화)

  • LEE, KEON JOO;KIM, SUNHOE
    • Journal of Hydrogen and New Energy
    • /
    • v.26 no.4
    • /
    • pp.324-330
    • /
    • 2015
  • The electrolyte flow rates of vanadium redox flow battery play very important role in terms of ion transfer to electrolyte, kinetics and pump efficiency in system. In this paper a vanadium redox flow battery single cell was tested to suggest the optimization criteria of electrolyte flow rates on the efficiencies. The compared electrolyte circulation flow rates in this experimental work were 15, 30 and 45 mL/min. The charge/discharge characteristics of the flow rate of 30 mL/min was the best out of all flow rates in terms of charging and discharging time. The current efficiencies, voltage efficiencies and energy efficiencies at the flow rate of 30 mL/min were the best. The IR losses obtained at thd current density of $40mA/cm^2$, at the flow rates of 15, 30 and 45 mL/min were 0.085 V, 0.042 V and 0.115 V, respectively. The charge efficiencies at the current density of $40mA/cm^2$ were 96.42%, 96.45% and 96.29% for the electrolyte flow rates of 15, 30 and 45 mL/min, respectively. The voltge efficiencies at the current density of $40mA/cm^2$ were 77.34%, 80.62% and 76.10% for the electrolyte flow rates of 15, 30 and 45 mL/min, respectively. Finally, the energy efficiencies at the current density of $40mA/cm^2$ were 74.57%, 77.76% and 73.27% for the electrolyte flow rates of 15, 30 and 45 mL/min, respectively. The optimum flow rates of electrolytes were 20 mL/min in most of operating variables of vanadium redox flow battery.