• Title/Summary/Keyword: min-min

Search Result 127,563, Processing Time 0.102 seconds

Application of microwave heating to the convenienet preparation of moist-heated meats (숙육 제조시 microwave의 효과적 이용에 관한 연구)

  • Oh, Hae-Sook;Myoung, Choon-Ok
    • Korean journal of food and cookery science
    • /
    • v.10 no.4
    • /
    • pp.357-362
    • /
    • 1994
  • Beef loaves(5${\times}5{\times}$5cm) were cooked by conventional moist-heat and by various levels of microwaves. The mean internal temperature of the meats cooked by low power microwaves for 5~15 min were not significantly different from the conventionally boiled meats for 30 min. When cooking was made by microwaves at low level for 5~10 min, or at high level for 2 min and additional heating at low power level for 5min, the percent cooking loss were comparable with the samples cooked conventionally for 20~40 min. General proteolytic activity determined with azocoll indicated that enzyme activity decreased as internal temperature increased(r=-0.5779, p<0.05), and maximum activity occured at meats conventionally moist-heated for 10 min and by low power microwave for 5 min. Sensory scores for tenderness were high at conventional moist-heat for 30 min, for 20 min, microwave cooked at thatwing power for 10 min and at low power level for 10 min, in descending order. There were no significant differences in the thiamin content of meats after various treatments.

  • PDF

The Effects of Electrical Stimulation on the Change of Oxytocin Immunoreactive cells (침전극 저주파자극이 옥시토신 면역반응세포 변화에 미치는 영향)

  • Kim, Soo-Han;Kim, Soon-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.4
    • /
    • pp.53-61
    • /
    • 2002
  • This study was carried out to investigate the effects of electrical stimulation on the change oxytocin(OT) immunoreactive cells in the hypothalamus of the male SD rats. Fifteen healthy and normal male rats were divided into three groups, 5 SD rat in each group. The one group has been stimulated by electro-acupuncture(EA, 2Hz) for 30 min and the other group by EA for 1hr 30 min and control group has not been stimulated. The results were summarized as follows. OT immunoreactive cells were found in the Paraventricular nucleus (PVN), Supraoptic nucleus(SON) and Lateral Magnocellular Area(LMA). The number of OT immunoreactive cells of PVN were significantly increased after 30 min as compared with control group (p<0.05) and were also significantly increased after 1hr 30min than 30 min(p<0.05). The number of OT immunoreactive cells of SON were significantly increased after 30 min and 1hr 30 min(p<0.05) as compared with control group, but decreased after 1hr 30 min than 30 min. The number of immunoreactive hells of LMA significantly increased after 30 min(p<0.05) as compared with control group, but significantly decreased after 1hr 30 min than 30 min(p<0.05). These results show that OT is released into the hypothalamus in response to electrical stimulation.

  • PDF

Corrosion Behavior of Hastelloy C-276 for Carbon-anode-based Oxide Reduction Applications

  • Jeon, Min Ku;Kim, Sung-Wook;Choi, Eun-Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.3
    • /
    • pp.383-393
    • /
    • 2020
  • The corrosion behavior of Hastelloy C-276 was investigated to identify its applicability for carbon-anode-based oxide reduction (OR), in which Cl2 and O2 are simultaneously evolved at the anode. Under a 30 mL·min-1 Cl2 + 170 mL·min-1 Ar flow, the corrosion rate was less than 1 g·m-2·h-1 up to 500℃, whereas the rate increased exponentially from 500 to 700℃. The effects of the Cl2-O2 composition on the corrosion rate at flow rates of 30 mL·min-1 Cl2, 20 mL·min-1 Cl2 + 10 mL·min-1 O2, and 10 mL·min-1 Cl2 + 20 mL·min-1 O2 with a constant 170 mL·min-1 Ar flow rate at 600℃ was analyzed. Based on the data from an 8 h reaction, the fastest corrosion rate was observed for the 20 mL·min-1 Cl2 + 10 mL·min-1 O2 case, followed by 30 mL·min-1 Cl2 and 10 mL·min-1 Cl2 + 20 mL·min-1 O2. The effects of the chlorine flow rate on the corrosion rate were negligible within the 5-30 mL·min-1 range. A surface morphology analysis revealed the formation of vertical scratches in specimens that reacted under the Cl2-O2 mixed gas condition.

Studies on the Cryopreservation and Survival after Thawing of Hamster Embryos (Hamster 수정란(受精卵)의 동결보존(凍結保存) 및 생존성(生存性)에 관한 연구(硏究))

  • Oh, Won Jin;Lee, Kyu Seung;Kim, Young Mook
    • Korean Journal of Agricultural Science
    • /
    • v.13 no.1
    • /
    • pp.82-89
    • /
    • 1986
  • This experiment was carried out to determine the optimum freezing and thawing rates of the hamster embryos. The female hamsters were induced to superovulate by intraperitoneal injections of 30 i.u. PMSG and mated with males of the same strain of 4 days the PMSG injection. They were killed and embryos were flushed from the oviduct and uterine horn on 3 days after mating. Embryos were flushed with a modified Dulbecco's phosphate-buffered saline and equilibrated with 1.5 M-dimethylsulphoxide by a 3-step procedure. The freezing rates of the samples were $1^{\circ}C/min$ from room temperature to $-6^{\circ}C$ and the samples were seeded at $-6^{\circ}C$. After being held for 3 min at the seeding temperature, the rates were $0.3^{\circ}C/min$ from $-6^{\circ}C$ to $-35^{\circ}C$. From $-35^{\circ}C$ to $-70^{\circ}C$, the rates were divided into $0.1^{\circ}C/min$, $1^{\circ}C/min$ and $10^{\circ}C/min$, respectively. At $-70^{\circ}C$ the samples were plunged directly into liquid nitrogen. The samples were thawed at $4^{\circ}C/min$ and $12^{\circ}C/min$ from $-196^{\circ}C$ to $37^{\circ}C$, and for 2 min in $37^{\circ}C$ water bath, respectively. The average numbers of ovulation points and embryos recovered were 35.1 and 27.0 appearing 77.0% recovery rates. Eight cell embryos in the embryos recovered were 24.8. The survival rates of embryos according to the freezing rates were 55.5~67.7% at $0.1^{\circ}C/min$, 58.8~64.9% at $1^{\circ}C/min$ and 40.5~44.7% at $10^{\circ}C/min$, respectively. The survival rates at $10^{\circ}C/min$ were significantly low. The survival rates of embryos according to the thawing rates were 53.5% at $4^{\circ}C/min$, 53.7% at $12^{\circ}C/min$ and 59.1% in $37^{\circ}C$ water bath. The survival rates, in $37^{\circ}C$ water bath were slightly higher, but we did not find any differences among them. In conclusion, the best freezing rates of hamster embryos were $1^{\circ}C/min$ from the room temperature to $-6^{\circ}C/min$, $0.3^{\circ}C/min$ from $-6^{\circ}C/min$ to $-35^{\circ}C$ and $-0.1^{\circ}C/min$ or $1^{\circ}C/min$ from $-35^{\circ}C$ to $-70^{\circ}C$. The hamster embryos thawed for 2 min in $37^{\circ}C$ water bath showed the best survival rates.

  • PDF

Effect of Dose Rate Variation on Dose Distribution in IMRT with a Dynamic Multileaf Collimator (동적다엽콜리메이터를 이용한 세기변조방사선 치료 시 선량분포상의 선량률 변화에 따른 효과)

  • Lim, Kyoung-Dal;Jae, Young-Wan;Yoon, Il-Kyu;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • Purpose: To evaluate dose distribution differences when the dose rates are randomly changed in intensity-modulated radiation therapy using a dynamic multileafcollimator. Materials and Methods: Two IMRT treatment plans including small-field and large-field plans were made using a commercial treatment planning system (Eclipse, Varian, Palo Alto, CA). Each plan had three sub-plans according to various dose rates of 100, 400, and 600 MU/min. A chamber array (2D-Array Seven729, PTW-Freiburg) was positioned between solid water phantom slabs to give measurement depth of 5 cm and backscattering depth of 5 cm. Beam deliveries were performed on the array detector using a 6 MV beam of a linear accelerator (Clinac 21EX, Varian, Palo Alto, CA) equipped with 120-leaf MLC (Millenium 120, Varian). At first, the beam was delivered with same dose rates as planned to obtain reference values. After the standard measurements, dose rates were then changed as follows: 1) for plans with 100 MU/min, dose rate was varied to 200, 300, 400, 500 and 600 MU/min, 2) for plans with 400 MU/min, dose rate was varied to 100, 200, 300, 500 and 600 MU/min, 3) for plans with 600 MU/min, dose rate was varied to 100, 200, 300, 400 and 500 MU/min. Finally, using an analysis software (Verisoft 3.1, PTW-Freiburg), the dose difference and distribution between the reference and dose-rate-varied measurements was evaluated. Results: For the small field plan, the local dose differences were -0.8, -1.1, -1.3, -1.5, and -1.6% for the dose rate of 200, 300, 400, 500, 600 MU/min, respectively (for 100 MU/min reference), +0.9, +0.3, +0.1, -0.2, and -0.2% for the dose rate of 100, 200, 300, 500, 600 MU/min, respectively (for 400 MU/min reference) and +1.4, +0.8, +0.5, +0.3, and +0.2% for the dose rate of 100, 200, 300, 400, 500 MU/min, respectively (for 600 MU/min reference). On the other hand, for the large field plan, the pass-rate differences were -1.3, -1.6, -1.8, -2.0, and -2.4% for the dose rate of 200, 300, 400, 500, 600 MU/min, respectively (for 100 MU/min reference), +2.0, +1.8, +0.5, -1.2, and -1.6% for the dose rate of 100, 200, 300, 500, 600 MU/min, respectively (for 400 MU/min reference) and +1.5, +1.9, +1.7, +1.9, and +1.2% for the dose rate of 100, 200, 300, 400, 500 MU/min, respectively (for 600 MU/min reference). In short, the dose difference of dose-rate variation was measured to the -2.4~+2.0%. Conclusion: Using the Varian linear accelerator with 120 MLC, the IMRT dose distribution is differed a little <(${\pm}3%$) even though the dose-rate is changed.

  • PDF

키토산 분자량 변화에 따른 키토산 비드 제조에 관한 연구

  • 이승원;김동석
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.05a
    • /
    • pp.303-306
    • /
    • 2003
  • autoclaving을 이용하여 키토산의 분자량을 변화 시켜서 납 중금속제거 실험을 하였다. 또한 이 키토산을 이용하여 비드를 만들어서 분말 상태의 키토산과 제거능 비교실험을 하였다. 먼저 분말상태의 키토산과 분말상태의 키토산을 비드로 만들었을때의 납 제거량은 비드가 분말보다는 많이 제거 되는 것으로 나왔고, 분말 상태에서의 제거된 순서는 15 min > 60 min > 0 min으로 나타났고, 비드의 경우도 마찬가지로 15 min > 60 min > 0 min의 순으로 나타났다. 이와 같은 연구 결과로 볼 때 autoclaving 처리 시간은 15 min이 가장 적당했으며, 이를 비드로 만들었을 때에는 분말상태의 키토산보다는 제거량이 더 많은 것으로 나타났다.

  • PDF

Response of Electrocardiogram to Mirror carp, Cyprinus carpio of Body Length (체장에 따른 향어, Cyprinus carpio의 심전도)

  • 김영기;양용림;안영일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.4
    • /
    • pp.284-288
    • /
    • 2002
  • The authors examined the response of electrocardiogram (ECG) to Mirror carp, Cyprinus carpio of body length. The experiments were performed of three classes (10~15, 15~20 and 20~25cm) were given to fishes with an electrode inserted into their bodies and then their ECGs were recorded continuously for 30 minutes in 16-18$^{\circ}C$. The results which are divided into by day and by night and then analyzed by fishes' conditions are as follows; 1 In case of body length 10~15 cm, the average heart rate 43.4 beat/min by day and 45.9 beat/min by night, the average action potential 4.38 $mutextrm{V}$ by day and 3.64 $mutextrm{V}$ by night, in narcotism condition(0~9 min). the average heart rate 69.4 beat/min by day and 67.4 beat/min by night, the average action potential 3.82 $mutextrm{V}$ by day and 3.50 $mutextrm{V}$ by night, in stable condition(9~30 min). 2. In case of body length 15~20 cm, the average heart rate 42.2 beat/min by day and 45.4 beat/min by night, the average action potential 4.13 $mutextrm{V}$ by day and 3.95 $mutextrm{V}$ by night, in narcotism condition(0-5 min). the average heart rate 67.6 beat/min by day and 65.3 beat/min by night, the average action potential 4.58$mutextrm{V}$ by day and 4.61 $mutextrm{V}$ by night, in stable condition (5~30 min). 3. In case of body length 20~25 cm, the average heart rate 47.5 beat/min by day and 47.5 beat/min by night, the average action potential 4.81 $mutextrm{V}$ by day and 4.20 $mutextrm{V}$ by night, in narcotism condition(0-4 min). the average heart rate 67.5 bea/min by day and 64.8 beat/min by night, the average action potential 5.31 $mutextrm{V}$ by day and 4.90 $mutextrm{V}$ by night, in stable condition (4~30 min).

Distribution of the Scatter Ray in Fluoroscopy X-ray Room (투시 검사실 내 공간산란선 분포 측정)

  • Cho, Pyong-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.349-354
    • /
    • 2011
  • The results of the scattery distribution in the fluoroscopy X-ray room were as follows. When the measurement was done at the same height with the table, measured value was 0.78 mGy/min ~ 0.04 mGy/min (95%) within 50 cm and 250 cm. At 50 cm below the table, it was 0.17 mGy/min ~ 0.02mGy/min (86%) and at 50 cm above the table was 1.37 mGy/min ~ 0.05 mGy/min (96%), displaying a decrease. At the same time, the amount of rays were reduced in 50 ~ 60% at the same height with the table than the location 50 cm above the table, 90~95% of reduction rate was observed at 50 cm below the table. For the collimator, comparing to the case when it was completely open, the amount of ray was reduced from 0.78 mGy/min to 0.16 mGy/min at 50cm away and 0.04 mGy/min to 0.01 mGy/min at 250cm away thus approximately 80% on average was reduced when the collimator was reduced to 25%. Comparing with the case when there was a object on the table, the amount of scatter ray was reduced by 96.7% at every location when there is not a object on the table.

Changes in Biologically Active Component of Angelica keiskei by Cooking Methods (조리방법을 달리한 신선초(Angelica keiskei)의 생리활성 성분의 변화)

  • 전순실;박종철;김성환;이도영;최현미;황은영
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.27 no.1
    • /
    • pp.121-125
    • /
    • 1998
  • The effects of various cooking methods (blanching, microwave heating, and deep-fat frying) on biologically active components of Angelica keiskei were determined by HPLC. Cynharoside, the biologically active component of Angelica keiskei leaves was 4.82%, which was rapidly decreased by blanching, showing 3.79%, 2.59% and 1.74% at 1 min, 2min and 3min, respectively. Microwave heating also decreased the cynaroside contents slowly by 2 min and rapidly by 3min, respectively. Microwave heating also decreased the cynaroside contents slowly by 2min and rapidly by 3 min, showing 4.25% at 1 min, 3.38% at 2 min, and 1.49% at 3 min. Among the cooking methods tested, deep-fat frying was shown to preserve the cynaroside most. Only 3.90% of cynaroside was lost by 5 min frying. The decrease in cynaroside in each cooking method was supposed to be due to the conversion of cynarside, a glycoside of flavonoid, into luteolin through lysis of glucose at C-7 position on cynaroside.

  • PDF

Effect of Application of Tetracycline - HCl on Implant Surface;Scanning Electron Microscopic Study (염산테트라싸이클린이 임플란트 표면에 미치는 효과;주사전자현미경적 연구)

  • Hong, Jung-Ah;Herr, Yeek;Lee, Man-Sup;Park, Joon-Bong
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.333-344
    • /
    • 2001
  • The present study was performed to evaluate the effect of tetracycline - HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface and titanium plasma-sprayed surface were utilized. Implant surface was rubbed with 50mg/ml tetracycline - HCl solution for 1 min., $1\frac{1}{2}\;min$., 2 min., $2\frac{1}{2}\;min$. and 3min. respectively in the test group and with saline for 1 min. in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. Pure titanium machined surfaces conditioned with saline for 1 min., showed a few shallow grooves and ridges and were less irregular. 2. Pure titanium machined surfaces conditioned with 50mg/ml tetracycline - HCl solution showed more irregular and corrosive surfaces compared to the control group irrespective of the application time of tetracycline - HCl solution. 3. Titanium plasma-sprayed surfaces conditioned with saline for 1 min., were deposited with round amorphous particles and showed round or irregular pores that can be connected to each other. 4. The irregularity of titanium plasma-sprayed surfaces conditioned with 50mg/ml tetracycline - HCl solution was lessened and the flattened areas were wider relative to the application time of tetracycline - HCl solution. 5. Titanium plasma-sprayed surfaces conditioned with tetracycline - HCl solution for 1 min. and $1\frac{1}{2}\;min$. were very similar to that of the control group, but the surfaces conditioned for 2 min., $2\frac{1}{2}\; min$. and 3 min. were changed. In conclusion, pure titanium machined surfaces were changed irrespective of the application time of tetracycline - HCl solution. And titanium plasma-sprayed surfaces conditioned with tetracycline - HCl solution began to be changed from $1\frac{1}{2}\;min$. This results will be applicable to the regenerative procedures for peri-implantitis treatment.

  • PDF