• Title/Summary/Keyword: milling block

Search Result 48, Processing Time 0.02 seconds

Marginal and internal fit of nano-composite CAD/CAM restorations

  • Park, So-Hyun;Yoo, Yeon-Jee;Shin, Yoo-Jin;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.1
    • /
    • pp.37-43
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. Materials and Methods: A full veneer crown and an mesio-occluso-distal (MOD) inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU) and experimental nano-composite CAD/CAM blocks (EB) under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis. Results: Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000). In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001). Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000). Conclusions: The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

Comparison of marginal fit of metal copings according to wax blocks and oral scanning methods (구강인기법과 왁스블록의 종류에 따른 금속 코핑의 변연적합도 비교)

  • Chung, In-Sung;Kim, Won-Young;Jeon, Byung-Wook
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.234-239
    • /
    • 2020
  • Purpose: We investigated the marginal fit between abutment and metal copings according to impression technique, wax block types, and metal types. Methods: We selected the traditional impression method of using rubber impression materials and the digital impression method of using oral scanners, three types of wax blocks, and two types of metal, both of which were domestically and commercially available, were selected to produce metal copings, and the marginal fit was determined through the use of silicon replication. Results: The measurements of axial wall fit revealed that the IYV specimens had the best fit, with a mean gap of 24.11±5.95 ㎛, followed by CEV, CHV, CSS, CSV, CES, CHS, and IYS specimens (mean: 33.44±8.41 ㎛). The differences were not statistically significant. The marginal gap measurements showed that the CEV specimen had the smallest gap, 17.25±4.13 ㎛, followed by the CSV, CHV, CSS, CES, CHS, IYV, and IYS specimen (mean: 43.47±15.63 ㎛). The differences were statistically significant. Conclusion: The axial wall fit of the metal coping (VeraBond2V; Aalba Dent, Inc., Fairfield, CA, USA) produced by the lost wax technique with the traditional impression method was excellent. The marginal fit of the metal coping (VeraBond 2V) produced by wax milling with the use of an oral scanner was also excellent. The marginal fit of the metal coping was within the clinically acceptable limits in all groups.

The dimension analysis of prepared natural teeth for developing customized zirconia block (맞춤형 지르코니아 블락 제작을 위한 삭제된 치아의 평균 크기 분석)

  • Kim, Min-Hyuk;Kim, Sung-Hun;Yeo, In-Sung;Yoon, Hyung-In;Lee, Jae-Hyun;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.381-388
    • /
    • 2017
  • Purpose: Unpredictable shrinkage of zirconia during sintering process causes discrepancy. Therefore, there have been attempts to reduce discrepancy by milling zirconia after sintering. However, due to the hardness of sintered zirconia, milling takes longer time, causes damage to the machine and causes chip formation. With customized zirconia block using the mean dimension of prepared natural dentition, it is expected to overcome these shortcomings. Materials and methods: The mean dimension of prepared natural dentition was analyzed as STL file after scanning of prepared teeth treated at SNUDH. The transverse, frontal and sagittal planes were set using Mimics and Photoshop. 3D volume was projected on each plane, and the outer line was measured through external tangent line, and the inner line was measured through inflection point of tangent line. Results: The mean height of prepared incisal (N = 57) is $6.60{\pm}1.05mm$, mesiodistal length is $2.98{\pm}0.73mm$, buccolingual length is $2.04{\pm}0.73mm$. The mean height of prepared premolar (N = 15) is $5.37{\pm}1.49mm$, mesiodistal length is $4.10{\pm}1.78mm$, buccolingual length is $5.86{\pm}1.55mm$. And the mean height of prepared molar (N = 13) is $5.11{\pm}1.29mm$, mesiodistal length is $6.80{\pm}1.18mm$, buccolingual length is $7.34{\pm}1.40mm$. Conclusion: Using the mean dimension of prepared natural dentition, it is expected to be able to fabricate customized zirconia block.

Influence of Replacing Corn Grain by Enzose (Corn Dextrose) on Nutrient Utilization, Thyroid Hormones, Plasma Metabolites, and Weight Gain in Growing Lambs

  • Shahzad, M. Aasif;Nisa, M.;Sarwar, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.7
    • /
    • pp.946-951
    • /
    • 2011
  • The study was conducted to evaluate enzose (corn dextrose), a corn milling byproduct, as substitute for corn grain as energy in growing lambs. Five iso-caloric and iso-nitrogenous diets were formulated. The control diet (E0) had no enzose whereas enzose replaced 20, 40, 60 and 80% corn grain in E20, E40, E60 and E80 diets on the basis of energy supply, respectively. Fifty growing lambs were divided into 5 groups, 10 animals in each, in a randomized complete block design. Nutrients (dry matter, crude protein, neutral detergent fiber and acid detergent fibre) intake and digestibilities increased with gradual replacement of corn grain by enzose. Lambs fed E80 diet also retained higher nitrogen (N) than those fed E0 diet. Plasma glucose, $T_3$ and $T_4$ increased while urea N decreased in lambs receiving higher enzose content. Maximum weight gain was recorded in lambs fed diets containing maximum concentration of E as a replacement for corn grains. A better feed conversion ratio was recorded in lambs fed E80 compared with those fed E0 diet. The study suggests that enzose can be used as an economical feed ingredient to replace corn grain upto 80%, without any adverse effects on growth performance of growing lambs.

Analysis of quality for fixed prostheses fabricated by dental CAD-CAM system (치과용 캐드캠 시스템으로 제작된 고정성 보철물의 품질 분석)

  • Kim, Won-Soo;Han, Man-So;Jung, Jae-Kwan;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.36 no.3
    • /
    • pp.159-164
    • /
    • 2014
  • Purpose: The purpose of this study was analysis of quality of fixed prostheses fabricated by dental CAD/CAM system. Methods: The ten same cases of stone models were manufactured by dental scannable model, and stone models were scanned using the dental scanner for changing digital model. Ten digital models were completed. The design of zirconia core for zirconia based all-ceramic crown was conducted by the dental CAD program. The samples were fabricated using the pre-sintered zirconia block by dental milling machine. Marginal gaps were analyzed using by silicone replica technique at the eight parts for quality analysis of samples. One-way ANOVA was used for statistical analysis(${\alpha}=0.05$). Results: The mean for marginal gaps were $93.2{\sim}99.1{\mu}m$ at the eight parts. One-was ANOVA didn't show significant differences(p=0.089). Conclusion: The fixed dental prostheses fabricated by dental CAD/CAM were within clinically acceptable range.

A Study on Thermal Performance of Microchannel Waterblock for Cooling of CPU in Desktop (컴퓨터 CPU 냉각용 미세채널 워터블록의 열성능에 관한 연구)

  • Choi, Mi-Jin;Kwon, Oh-Kyung;Cha, Dong-An;Yun, Jae-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.264-269
    • /
    • 2007
  • The microchannel waterblock has a good capability in the cooling of electronic devices. The object of this paper is to study on thermal performance of microchannel water block for cooling of CPU in desktop. The effects of header shape, liquid flow rate, and inlet temperature on the thermal performances of microchannel waterblock are investigated experimentally. Three types of waterblock with different header shape are manufactured from the micro milling and brazing processing. The experiments are conducted using water, over a liquid flow rate ranging from 0.7 to 2.0 LPM and inlet temperature ranging from 20 to $35^{\circ}C$. Waterblocks are attached both horizontally and vertically on the test section to anticipate a performance of waterblock under the actual state in computer. The base temperature and thermal resistance decrease with increasing of liquid flow rate. It was found that the sample #1 was appropriate for the prototype of liquid cooling system.

  • PDF

EFFECT OF SURFACE TREATMENT METHODS ON THE SHEAR BOND STRENGTH OF RESIN CEMENT TO ZIRCONIA CERAMIC

  • Lee, Ho-Jeong;Ryu, Jae-Jun;Shin, Sang-Wan;Sub, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.743-752
    • /
    • 2007
  • Statement of problem. The aims of the study were to evaluate the effect of current surface conditioning methods on the bond strength of a resin composite luting cement bonded to ceramic surfaces and to identify the optimum cement type. Material and methods. The sixty zirconia ceramic specimens(10 per group) with EVEREST milling machine and 60 tooth block were made. The zirconia ceramic surface was divided into two groups according to surface treatment: (1) airborne abrasion with $110{\mu}m$ aluminum oxide particles; (2) Rocatec system, tribochemical silica coating. The zirconia ceramic specimens were cemented to tooth block using resin cements. The tested resin cements were Rely X ARC, Panavia F and Superbond C&B. Each specimen was mount in a jig of the universal testing machine for shear strength. The results were subjected to 2-way ANOVA and Post hoc tests was performed using Tukey, Scheffe, and Bonferroni test. Results. The mean value of shear bond strength(MPa) were as follows: $$RelyXARC(+Al_2O_3),5.35{\pm}1.69$$; $$RelyXARC(+Rocatec),8.50{\pm}2.13$$; $$PanaviaF(+Al_2O_3),9.58{\pm}1.13$$; $$PanaviaF(+Rocatec),12.98{\pm}1.71$$; $$SuperbondC&B(+Al_2O_3)8.27{\pm}2.04$$; $$SuperbondC&B(+Rocatec),14.46{\pm}2.39$$. There was a significant increase in the shear bond strength when the ceramic surface was subjected to the tribochemical treatment(Rocatec 3M) in all cement groups(P<0.05). Bonding strengths of cements applied to samples treated with $Al_2O_3$ were compared; Rely X ARC showed the lowest values, whereas Panavia F cement showed higher value than that of Superbond C&B group with no statistical significance. When the bond strength of cements with of Rocatec treatment was compared, Rely X ARC showed lowest values. Overall, it was apparent that tribochemical treated Super-Bond possessed higher mean bond strength (14.46MPa; P<0.05) than that of Panavia F cement group with no significance. Conclusions. Silica coating followed silanization(Rocatec treatment) increase the bond strength between resin cement and zirconia ceramic. Panavia F containing phosphate monomer and Superbond C&B comprised of 4-META tend to bond chemically with zirconia ceramic, thus demonstrating higher bond strength compared to BisGMA resin cement. Superbond C&B has shown to have highest value of bonding strength to zirconia ceramic after Rocatec treatment compared to other cement.

FIT OF FIXTURE/ABUTMENT/SCREW INTERFACES OF INTERNAL CONNECTION IMPLANT SYSTEM

  • Kim, Jin-Sup;Kim, Hee-Jung;Chung, Chae-Heon;Baek, Dae-Hwa
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.338-351
    • /
    • 2005
  • Statement of problem. Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft tissue reaction, and destruction of osseointegration. Purpose. This study is to evaluate the machining accuracy and consistency of the implant fixture/ abutment/screw interfaces of the internal connection system by using a Stereoscopic Zoom microscope and FE-SEM(field emission scanning electron microscope) Materials and methods. The implant systems selected in this study were internal connection type implants from AVANA(Osstem^{\circledR}), Bioplant(Cowell-Medi^{\circledR}), Dio(DIO^{\circledR}), Neoplant(Neobiotech 􀋓), Implantium(Dentium􀋓)systems. Each group was acquired 2 fixtures at random. Two piece type abutment and one piece type abutment for use with each implant system were acquired. Screw were respectively used to hold a two piece type abutment to a implant fixture. The implant fixtures were perpendiculary mounted in acrylic resin block. Each two piece abutment was secured to the implant fixture by screw and one piece abutment also secured to the implant fixture. Abutment/fixture assembly were mounted in liquid unsaturated polyester. All samples were cross-sectioned with grinder-polisher unit. Finally all specimens were analysed the fit between implant fixture/abutment/screw interfaces Results and conclusions. 1. Implant fixture/abutment/screw connection interfaces of internal connection systems made in Korea were in good condition. 2. The results of the above study showed that materials and mechanical properties and quality of milling differed depending on their manufacturing companies.

Effect of Dietary Fiber on the Serum Lipid Level and Bowel Function in Aged Rats (노화된 흰쥐에서 식이섬유질원이 첨가된 식이가 혈청지질과 장기능에 미치는 효과)

  • 박은영
    • Journal of Nutrition and Health
    • /
    • v.29 no.9
    • /
    • pp.934-942
    • /
    • 1996
  • This study was performed to investigate the influence of dietary fibers on the serum lipid level and bowel function in aged rats. Fiber sources of experimental diets were made from mugwort(M), butterbur(B), apple(A), sea mustard(S) by drying and milling. Each of fiber sources was mixed into the diet at the level of 5, 15% of diet. Sprague-Dawley strain, 13 month old male rats were divided into 9 groups by randomized complete block design : C, M5, B5, A5, S5, M15, B15, A15, S15. The animals were fed ad libitum each of experimental diets for 4 weeks. Control group showed lower food intake compare to the other groups. There were no significant difference between 5% groups and 15% groups in food intake. Fecal weight, dry fecal weight and fecal water content of control group were significantly lower than those of experimental groups, and fecal water content was increased by increasing level of dietary fibber. Apple group showed the lowest values, sea mustard group showed the highest. The shorter transit time was observed in the group of higher intake of dietary fiber. At the same level of dietary fiber, transit time of sea mustard group was shorter than the other groups. With increasing age, serum triglycerides, total cholesterol were increased and HDL-cholesterol was decreased. Fiber fed groups showed lower serum TG, TC and higher HDL-c level compare to the control group. Absorption rates of calcium, magnesium and phosphorus was tend to be lower in the group fed dietary fiber sources than control group. Mucosa weight and maltase activity in the small intestine were decreased by increasing age. As intake of dietary fiber increaed, mucosa weight in the small intestine was not different but maltase activity was decreased.

  • PDF

Thermal-hydraulic Design of A Printed-Circuit Steam Generator for Integral Reactor (일체형원자로 인쇄기판형 증기발생기 열수력학적 설계)

  • Kang, Han-Ok;Han, Hun Sik;Kim, Young-In
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.6
    • /
    • pp.77-83
    • /
    • 2014
  • The vessel of integral reactor contains its major primary components such as the fuel and core, pumps, steam generators, and a pressurizer, so its size is proportional to the required space for the installation of each component. The steam generators take up the largest volume of internal space of reactor vessel and their volumes is substantial for the overall size of reactor vessel. Reduction of installation space for steam generators can lead to much smaller reactor vessel with resultant decrease of overall cost for the components and related facilities. A printed circuit heat exchanger is one of the compact types of heat exchangers available as an alternative to conventional shell and tube heat exchangers. Its name is derived from the procedure used to manufacture the flat metal plates that form the core of the heat exchanger, which is done by chemical milling. These plates are then stacked and diffusion bonded, converting the plates into a solid metal block containing precisely engineered fluid flow passages. The overall heat transfer area and pressure drops are evaluated for the steam generator based on the concept of the printed circuit heat exchanger in this study. As the printed circuit heat exchanger is known to have much larger heat transfer area density per unit volume, we can expect significantly reduced steam generator compared to former shell and tube type of steam generator. For the introduction of new steam generator, two design requirements are considered: flow area ratio between primary and secondary flow paths, and secondary side parallel channel flow oscillation. The results show that the overall volume of the steam generator can be significantly reduced with printed circuit type of steam generator.