• Title/Summary/Keyword: midshaft clavicular fracture

Search Result 6, Processing Time 0.024 seconds

Clinical and Radiological Outcome after Surgical Treatment in Displaced Clavicular Midshaft Fracture

  • Gwak, Heui-Chul;Kim, Jung-Han
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.2
    • /
    • pp.73-77
    • /
    • 2016
  • Background: The first purpose of this study is to compare the clinical and radiological outcomes of surgical treatment for displaced midshaft clavicle fracture (Robinson type 2B1 vs. 2B2) with 3.5-mm low profile clavicular locking compression plate. The second purpose is to evaluate the difference of the results depending on the presence of accompanying injuries. Methods: Forty-nine patients who underwent an operation for the fractures were reviewed retrospectively. Fracture patterns were classified according to group 2B1 and 2B2 using Robinson's classification. For radiological outcome, time to union after operation was evaluated and for clinical outcome, American Shoulder and Elbow Society (ASES) score, University of California in Los Angeles (UCLA) score, visual analogue scale (VAS), and range of motion (ROM) were evaluated from preoperative period to last follow-up period. Results: The mean time for union was not significantly different in the 2B1 group and 2B2 group (p=0.062). No statistically significant difference in ASES score, UCLA score, and VAS was observed between 2B1 and 2B2 (p=0.619, p=0.896, p=0.856, respectively). In ROM, significant higher mean forward flexion and abduction was observed in 2B2 (p=0.025, p=0.017, respectively) and there was no difference in external rotation and external rotation at shoulder $90^{\circ}$ abduction position (p=0.130, p=0.180, respectively). There was no significant difference in clinical outcomes according to the accompanying injuries. Conclusions: There was no difference in clinical and radiological outcome between Robinson 2B1 and 2B2 type fracture after the operation. Accompanying injuries may not affect the clinical result of displaced midshaft clavicle fractures.

The Analysis of Conservative Treatment in Midshaft Fractures of Clavicle (쇄골 간부 골절의 보존적 치료 분석)

  • Cha, Seung-Do;Chung, Soo-Tai;Kim, Yong-Hoon;Park, Sang-Jun
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.27-33
    • /
    • 2010
  • Purpose: Most clavicular fractures can be healed by conservative treatment, although there are many factors that influence healing. The aim of the present study was to analyze factors that influence (i) bone union of midshaft fractures of the clavicle treated conservatively and (ii) bone functioning, after union. The long-term goal was to determine which treatments are adequate. Materials and Methods: We evaluated factors that have an effect on bone union and bone function after union. We evaluated age, fracture site, comminution, displacement, shortening and other factors. Among 523 clavicular midshaft fractures that presented between January 2004 and Jun 2009 at our Department of Orthopaedic Surgery, we identified 270 who had conservative treatment and 173 patients who had surgical treatment. Results: The period required for bone union increased with the degree of displacement. For the group below 12 years of age, and the group without comminution, it took half the time to achieve bone union compared with the other groups. Displacement mostly occurred within 2 weeks after conservative treatment. Conclusion: In patients with a comminuted clavicular midshaft fracture, we might, because of expected delays in bone union, delay the start of rehabilitation until patients are more than 13 years old. Because the degree of displacement may be increased within 2 weeks during conservative treatment, we can think about surgical treatments.

Operative Treatment of Fractures of the Midshaft Clavicle using Locking Compression Plate (Locking Compression Plate를 이용한 전위성 쇄골 간부 골절의 수술적 치료)

  • Chung, Nam-Sik;Hong, Ki-Do;Ha, Sung-Sik;Park, Sung-Joon;Kang, Jung-Ho;Sim, Jae-Cheon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.63-68
    • /
    • 2006
  • Purpose: To assess the effectiveness of the Locking compression plate (LCP) after open reduction for the treatment of the displaced clavicular shaft fracture, the clinical and radiologic outcome of the patients who were managed with the LCP for internal fixation after open reduction has been analyzed. Materials and Methods: We reviewed 26 cases with a displaced clavicular shaft fracture treated by internal fixation using Locking compression plate after open reduction between May 2003 and November 2004. The patients were followed up for at least six months period, and final postoperative outcome was evaluated using clinical results based on Kang's criteria, radiologic signs of fusion. Results: All fractures united by an average of 9.3 weeks without delayed union and showed fast recovery of motion fraction and shoulder function. In addition,24 cases without the fractures of proximal humerus recovered to normal range of shoulder notion within 2.9 weeks. Clinically, according to Kang's criteria, the outcome was good or better in 22 patients. The complications included shoulder joint dysfunction in two cases and keloid formation in one case, and no other complications were observed. Conclusion: The internal fixation using LCP for the treatment of displaced clavicular shaft fracture is a safe, reliable method of treatment, with few complications, and offers rapid recovery of shoulder joint function and bone union.

  • PDF

Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union? (쇄골 간부 복합 골절에서 재건 금속판 및 환 강선을 이용한 수술적 치료: 환 강선이 골 유합을 방해하는가?)

  • Kim, Kyung-Tae;Shin, Chung-Shik;Park, Young-Chul;Kim, Dong-hyun;Kim, Min-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.245-252
    • /
    • 2021
  • Purpose: This study examined the radiological and clinical outcomes of internal fixation using a reconstruction plate and 21G circumferential wire in comminuted midshaft clavicular fractures. Materials and Methods: A retrospective cohort study was performed on 51 patients between 2005 and 2019. Thirty-two patients underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and 19 patients underwent surgery without a wire. The patients were assessed with the radiographic parameters, the University of California at Los Angeles (UCLA) score, and the visual analogue scale (VAS) pain score. Based on this, patients who operated without a circumferential wire were set as the control group, and the differences in bone union between the two groups were compared. Results: Thirty-two patients were followed-up for an average of 65 weeks, and 19 patients in the control group were followed-up for an average of 56 weeks. The radiological evaluation confirmed the anatomical reduction and bone union in all 32 patients. No case of nonunion was present. The UCLA score was 32.38 on average and 33.11 in the control group (p=0.395). The VAS score was 1.00 on average and 0.84 in the control group (p=0.668). A significant difference in the bony union time was observed between the group who underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and the control group (p=0.015). On the other hand, there was no statistical significance when other variables were controlled (p=0.107). Conclusion: For displaced midshaft clavicular fractures, internal fixation using a reconstruction plate and 21G circumferential wire maintained accurate anatomical reduction. The satisfactory clinical and radiological results mean that internal fixation using a reconstruction plate and 21G circumferential wire may be a good option for surgical treatment.

The use of precontoured plates for midshaft clavicle fractures is not always the best course of treatment

  • Manmohan Patel;Mohtashim Ahmad;Natwar Agrawal;Sumit Tulshidas Patil;John Ashutosh Santoshi;Bertha Rathinam;Kusum Rajendra Gandhi
    • Anatomy and Cell Biology
    • /
    • v.56 no.4
    • /
    • pp.456-462
    • /
    • 2023
  • Plate fixation has become the preferred approach for treating displaced midshaft clavicle fractures. However, plate fixation of the clavicle presents several unique challenges, including its complex bony architecture and its immediate subcutaneous location. In many cases, we have observed that precontoured implants do not conform to the clavicular anatomy, and many patients complain of postoperative implant-related discomfort. A total of 111 clavicles, both left and right sides, were examined to match two commonly used designs of anatomical pre-contoured superior anterior clavicle plates, with and without lateral extension. The anteroposterior (AP) plane congruence of the plate to the underlying bone, the vertical gap between the bone and plate, and the length of the plate that was off the bone either anteriorly and/or posteriorly at both ends of the clavicle were measured. The scoring system was used to determine the fit of the implant on the clavicle as anatomic, good, or poor. We found that the maximum superior bow of the clavicle was lateral to the midline by 30.75 mm and 30.5 mm on the right and left sides, respectively. The magnitude of the bow was 4.28 mm and 4.46 mm on the right and left sides, respectively. We also found that the plate was a poor fit in 75.86% of cases on the left side and 73.5% of cases on the right side. Manipulating the plates during surgery was very difficult in the AP plane.

Operative Treatment of the Clavicular Midshaft Fractures in Adult - A Comparison between Intramedullary Multiple Steinmann Pins Fixation and Reconstruction Plate Fixation - (성인 쇄골 간부 골절의 수술적 치료-골수강내 다발성 Steinmann핀 고정술과 재구성 금속판 고정술과의 비교-)

  • Lee Young Kuk;Gu Hae Seo
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.1
    • /
    • pp.14-20
    • /
    • 1999
  • Purpose: Despite of the popular use of the reconstruction plate for the fixation of clavicular shaft fractures, some disadventages have been raised such as long period of immobilization, long skin incision, loosening of plate and screws, and increased chance of nonunion due to severe periosteal injury. Thus, the authors have performed intramedullary multiple Steinmann pins fixation that could reduce the disadvantages of plate fixation in order to compare the treatment results between the two groups. Materials & Methods: From 1994. Jan. to 1997. Dec. the department of orthopaedic surgery of the Kwak's hospital treated operatively for 56 cases of the clavicular shaft fractures in adult. 39 cases of them were treated with the plate fixation and 17 cases with the intramedullary multiple Steinmann pins fixation(SP group). Reconstruction plates(Plate group) were used for 26 out of 39 patients treated with plate fixation. Among the Plate group and SP group, each 15 cases were selected by age and sex and compared each other according to the bone union time, union rate, complication, and functional results. The follow-up period was 12 months at the shortest and 48 months at the longest and the average was 16 months. Results: The Plate group showed that the bone union time was 7 weeks and the bone union rate was 93%. The SP group showed 6.5 weeks and 100% respectively. In complication, the Plate group had 1 case of loosening of plate and screws and delayed union; SP group had 1 case of pin migration. The functional results according to Kang's criteria, 87% of the Plate group and 93% of the SP group showed good or excellent. Conclusion : The SP group showed very comparable results in terms of the bone union time, bone union rate, complication, and functional results comparing to the Plate group. The intramedullary multiple Steinmann pins fixation showed several advantages over the reconstruction plate fixation, which were simple operative technique, easy removal of pins, being able to perform immediate postoperative full range of motion exercise. Therefore, the intramedullary multiple Steinmann pins fixation is thought to be one of the useful operative techniques in treatment of the clavicular shaft fractures in adult.

  • PDF