• Title/Summary/Keyword: mid-infrared spectroscopy

Search Result 53, Processing Time 0.029 seconds

Design and Analysis of Optical Properties of Anti-reflection Coated ZnS Substrates in the Mid-infrared Region (중적외선 영역의 무반사 코팅된 ZnS 기판의 설계와 광학 특성)

  • Park, Buem Keun;Paik, Jong-Hoo
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.255-259
    • /
    • 2022
  • In this study, we fabricated ZnS substrates with excellent transmittance in the mid-infrared region (3-5 ㎛) using hot pressing instead of conventional chemical vapor deposition (CVD). Diamond-like carbon (DLC) was coated on either one or both sides of the ZnS substrates to improve their mechanical properties and transmittance efficiency. To reduce the reflectance and further improve transmittance in the mid-infrared region, anti-reflection (AR) coating was designed for DLC/ZnS /AR and AR/ ZnS /AR structures. The coating structure, microstructure, and optical properties of the AR-coated ZnS substrates were subsequently investigated by employing energy dispersive X-ray spectroscopy, scanning electron microscopy, and Fourier-transform infrared (FTIR) spectroscopy. The FTIR spectroscopy results demonstrated that, in the mid-infrared region, the average transmittance of the samples with AR coating on one and both sides increased by approximately 18% and 27%, respectively. Thus, AR coating improved the transmittance of the ZnS substrates.

Quantitative Measurement of Ethane Using Mid-infrared Cavity Ring-down Spectroscopy

  • Yonghee Kim;Byung Jae Chun;Lim Lee;Kwang-Hoon Ko;Seung-Kyu Park;Taek-Soo Kim;Hyunmin Park
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.457-462
    • /
    • 2023
  • Quantitative measurement of trace ethane is important in environmental science and biomedical applications. For these applications, we typically require a few tens of part-per-trillion level measurement sensitivity. To measure trace-level ethane, we constructed a cavity ring-down spectroscopy setup in the 3.37 ㎛ mid-infrared wavelength range, which is applicable to multi-species chemical analysis. We demonstrated that the detection limit of ethane is approximately 300 parts per trillion, and the measured concentration is in agreement with the amounts of the injected sample. We expect that these results can be applied to the chemical analysis of ethane and applications such as breath test equipment.

THEORY AND PRINCIPLES OF NEAR INFRARED SPECTROSCOPY

  • Barton, Franklin E.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1012-1012
    • /
    • 2001
  • The elegant early experiments of Herschel demonstrated that there is light after the visible spectrum in a region we call the near infrared (NIR). This was followed by the work which showed that the spectrum went further into what we call the mid infrared (MIR). The MIR has been used for many years as a qualitative and quantitative region to measure constituent values. The MIR region contains the fundamental vibrations which can be theoretically calculated from symmetry rules and harmonic oscillator equations. The NIR is not as straight forward because the region from 400-2500 nm does not contain any of the fundamental vibrations only combination bands and overtones. Over the past fifty years efforts to understand the NIR have largely been ignored while the quantitative aspects of the region have been utilized. This presentation will focus on the efforts to define terms for NIR, examine the calculation of combination bands and overtones and ways to interpret the spectra. The interpretation of the NIR has been aided greatly in recent years by the use of two dimensional spectroscopy which allows the correlation of bands in one spectral region with that of the NIR.

  • PDF

VIBRATIONAL SPECTROSCOPY IN INDUSTRIAL CHEMICAL QUALITY CONTROL

  • Siesler, H.W.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1081-1081
    • /
    • 2001
  • The constant need for quality improvement and production rationalization in the chemical and related industries has led to the increasing replacement of conservative control procedures by more specific and environmentally compatible analytical techniques. In this respect, vibrational spectroscopy has developed over the last yews - in combination with new instrumental accessories and statistical evaluation procedures - to one of the most important analytical tools for industrial chemical quality control and process monitoring in a wide field of applications. In the present communication this potential is demonstrated in order to further support the implementation of mid-infrared (MIR), near-infrared (NIR) and Raman spectroscopy Primarily as industrial on-line tools. To this end the data of selected feasibility studies will be discussed in terms of the individual strengths of the different techniques for the respective application.

  • PDF

Optical Properties of DLC-coated ZnS Substrates in the Mid-infrared Region (중적외선 영역의 DLC 코팅된 ZnS 기판의 광학 특성)

  • Kwon, Tae-Hyeong;Yeo, Seo-Yeong;Kim, Chang-Il;Nahm, Sahn;Kwon, Min-Chul;Chu, Byoung-Uck;Paik, Jong-Hoo
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.101-105
    • /
    • 2019
  • ZnS substrates with excellent transmittance in the mid-infrared region ($3-5{\mu}m$) were prepared using hot pressing instead of conventional chemical vapor deposition (CVD). Diamond-like carbon(DLC) was coated on either one or both sides of the ZnS substrates to improve their mechanical properties and transmittance. More specifically DLC was coated using CVD with an Ar and $C_2H_2$ mixed gas, and Ge was used as the bonding layer. During CVD, the bias voltage was fixed to 500 V and analyzed by Fourier transform infrared spectroscopy (FT-IR), nanoindenter, scanning electron microscope and energy dispersive spectrometry. Results of hardness analysis using the nanoindenter, showed that DLC coating increased from 5.9 to 17.7 GPa after deposition. The FT-IR spectroscopy results showed that, in the mid-infrared region ($3-5{\mu}m$), the average transmittance of the samples with DLC coating on one and both sides increased by approximately 6% and approximately 11.2% respectively. In conclusion, the DLC coating improved the durability and transmittance of the ZnS substrates.

THE 3.3 MICRON PAH EMISSION OF THE MID-INFRARED EXCESS GALAXIES DISCOVERED BY THE AKARI MID-INFRARED ALL-SKY SURVEY

  • Yamada, R.;Oyabu, S.;Kaneda, H.;Yamagishi, M.;Ishihara, D.;Kim, J.H.;Im, M.;Toba, Y.;Matsuhara, H.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.299-300
    • /
    • 2012
  • We investigate the relation between star formation activity and PAH $3.3{\mu}m$ emission. Our targets are mid-infrared-excess galaxies selected from the AKARI all-sky survey point source catalog. We performed AKARI near-infrared spectroscopy for them. As a result, we obtained $2.5-5{\mu}m$spectra of 79 galaxies, and selected 35 star-forming galaxies out of them. Comparing the PAH $3.3{\mu}m$ luminosities with the infrared luminosities, we find a linear correlation between them. However, by adding the results from literatures for luminous infrared galaxies and ultra-luminous infrared galaxies that are more luminous than our sample, the ratio of the PAH to the infrared luminosity is found to decrease towards the luminous end.

Thermal denaturation analysis of protein

  • Miyazawa, Mitsuhiro
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1628-1628
    • /
    • 2001
  • Near infrared (NIR) spectroscopy is a powerful technique for non-destructive analysis that can be obtained in a wide range of environments. Recently, NIR measurements have been utilized as probe for quantitative analysis in agricultural, industrial, and medical sciences. In addition, it is also possible to make practical application on NIR for molecular structural analysis. In this work, Fourier transform near infrared (FT-NIR) measurements were carried out to utilize extensively in the relative amounts of different secondary structures were employed, such as Iysozyme, concanavalin A, silk fibroin and so on. Several broad NIR bands due to the protein absorption were observed between 4000 and $5000\;^{-1}$. In order to obtain more structural information from these featureless bands, second derivative and Fourier-self-deconvolution procedures were performed. Significant band separation was observed near the feature at $4610\;^{-1}$ ,. Particularly the peak intensity at $4525\;^{-1}$ shows a characteristic change with thermal denaturation of fibroin. The structural information can be also obtained by mid-IR and CD spectral. Correlation of NIR spectra with protein structure is discussed.

  • PDF

Reagentless Determination of Human Serum Components Using Infrared Absorption Spectroscopy

  • Hahn, Sang-Joon;Yoon, Gil-Won;Kim Gun-Shik;Park Seung-Han
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.240-244
    • /
    • 2003
  • Simultaneous determination of concentrations for four major components in human blood serum was investigated using a Fourier-transform mid-infrared spectroscopy. Infrared spectra of human blood serum were measured in 8.404 ∼ 10.25 ${\mu}m$ range where the highest absorption peaks of glucose are located. A partial least square (PLS) algorithm was utilized to establish a calibration model for determining total protein, albumin, globulin and glucose levels which are commonly measured metabolites. The standard error of cross validation obtained from our multivariate calibration model was 0.24 g/dL for total protein, 0.15 g/dL for albumin, 0.17 g/dL for globulin, and 6.68 mg/dL for glucose, which are comparable with or meet the criteria for clinical use. The results indicate that the infrared absorption spectroscopy can be used to predict the concentrations of clinically important metabolites without going through a chemical process with a reagent.

AKARI OBSERVATIONS OF THE INTERSTELLAR MEDIUM

  • Onaka, Takashi
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.187-193
    • /
    • 2012
  • AKARI has 4 imaging bands in the far-infrared (FIR) and 9 imaging bands that cover the near-infrared (NIR) to mid-infrared (MIR) contiguously. The FIR bands probe the thermal emission from sub-micron dust grains, while the MIR bands observe emission from stochastically-heated very small grains and the unidentified infrared (UIR) band emissions from carbonaceous materials that contain aromatic and aliphatic bonds. The multi-band characteristics of the AKARI instruments are quite efficient to study the spectral energy distribution of the interstellar medium, which always shows multi-component nature, as well as its variations in the various environments. AKARI also has spectroscopic capabilities. In particular, one of the onboard instruments, Infrared Camera (IRC), can obtain a continuous spectrum from 2.5 to $13{\mu}m$ with the same slit. This allows us to make a comparative study of the UIR bands in the diffuse emission from the 3.3 to $11.3{\mu}m$ for the first time. The IRC explores high-sensitivity spectroscopy in the NIR, which enables the study of interstellar ices and the UIR band emission at $3.3-3.5{\mu}m$ in various objects. Particularly, the UIR bands in this spectral range contain unique information on the aromatic and aliphatic bonds in the band carriers. This presentation reviews the results of AKARI observations of the interstellar medium with an emphasis on the observations of the NIR spectroscopy.

USE OF NEAR INFRARED FOR THE QUANTITATIVE ANALYSES OF BAUXITE

  • Walker, Graham S.;Cirulis, Robyn;Fletcher, Benjimin;Chandrashekar, S.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1171-1171
    • /
    • 2001
  • Quantitative analysis is an important requirement in exploration, mining and processing of minerals. There is an increasing need for the use of quantitative mineralogical data to assist with bore hole logging, deposit delineation, grade control, feed to processing plants and monitoring of solid process residues. Quantitative analysis using X-Ray Powder Diffraction (XRD) requires fine grinding and the addition of a reference material, or the application of Rietveld analysis to XRD patterns to provide accurate analysis of the suite of minerals present. Whilst accurate quantitative data can be obtained in this manner, the method is time consuming and limited to the laboratory. Mid infrared when combined with multivariant analysis has also been used for quantitative analysis. However, factors such as the absorption coefficients and refractive index of the minerals requires special sample preparation and dilution in a dispersive medium, such as KBr to minimize distortion of spectral features. In contrast, the lower intensity of the overtones and combinations of the fundamental vibrations in the near infrared allow direct measurement of virtually any solid without special sample preparation or dilution. Thus Near Infrared Spectroscopy (NIR) has found application for quantitative on-line/in line analysis and control in a range of processing applications which include, moisture control in clay and textile processing, fermentation processes, wheat analysis, gasoline analysis and chemicals and polymers. It is developing rapidly in the mineral exploration industry and has been underpinned by the development of portable NIR spectrometers and spectral libraries of a wide range of minerals. For example, iron ores have been identified and characterized in terms of the individual mineral components using field spectrometers. Data acquisition time of NIR field instruments is of the order of seconds and sample preparation is minimal. Consequently these types of spectrometers have great potential for in-line or on-line application in the minerals industry. To demonstrate the applicability of NIR field spectroscopy for quantitative analysis of minerals, a specific example on the quantification of lateritic bauxites will be presented. It has been shown that the application of Partial Least Squares regression analysis (PLS) to the NIR spectra can be used to quantify chemistry and mineralogy in a range of lateritic bauxites. Important, issues such as sampling, precision, repeatability, and replication which influence the results will be discussed.

  • PDF