• Title/Summary/Keyword: microwave digestion system

Search Result 34, Processing Time 0.026 seconds

Development of a Temperature Controller for Microwave-assisted Digestion System for Agricultural Samples (농식품 시료 전처리를 위한 마이크로웨이브 분해기용 온도 제어장치 개발)

  • Mo, Chang-Yeon;Kim, Gi-Young;Kim, Hak-Jin;Kim, Yong-Hun;Yang, Kil-Mo;Lee, Kang-Jin
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.371-376
    • /
    • 2009
  • Microwave digestion is a preferred pretreatment method for agricultural samples because of its quick chemical reaction and minimum loss of analytes. In this research, a feedback temperature controller was developed to control the temperature inside a vessel for the microwave-assisted digestion system. An existing industrial microwave oven was fitted with the temperature controller for controlling inside temperature of the vessel. Four control methods, On/Off, proportional (P), proportional integral (PI), and proportional integral derivative (PID) were used and compared. Experimental results showed that PID control produced best temperature control performance. The PID controller could maintain the temperature of water sample and rice sample in the digestion system with error range of $-2.5{\sim}3.3^{\circ}C$ and $-1.9{\sim}0.5^{\circ}C$ at set temperature of $170^{\circ}C$, respectively.

Development of Continuous Flow Microwave Digestion Procedures for Analysis of Trace Metal in Water Using Ion Chromatography

  • Youn Doo Kim;Gae Ho Lee;Hyung Seung Kim;Dong Soo Kim;Kwang Kyu Park
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.9
    • /
    • pp.786-791
    • /
    • 1994
  • A simple and rapid sample pretreatment process necessary for determination of metal oxides in water was proposed. Samples were injected into the continuous-flow tube installed inside the microwave oven and the treated samples were cooled before entered to the Ion Chromatography (IC) or Inductively Coupled Plasma (ICP). By coupling this microwave digestion system with IC or ICP, a fully automatic analytical procedures may be easily established. In this study, two different types of digestion methods were considered; the open tubing method (OTM) and the restraint tubing method (RTM). The RTM was proved to be 3 times faster in digestion period and 10 times higher in detection range than the OTM. Validation of proposed sample digestion system was carried out by using an ICP. The results showed that both of continuous-flow methods, the OTM and the RTM were comparable in accuracies with the conventional batch-type vessel digestion method.

Simultaneous Determination of Sulfur, Phosphorus, and Zine in Lubricating Oils by Microwave Digestion System and ICP-AES (마이크로파 분해장치와 유도결합 플라스마 원자방출분광법을 이용한 윤활유 시료 중 S, P 및 Zn의 동시 분석)

  • Cho, Sung-Ill;Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.324-330
    • /
    • 2001
  • For the analysis of S, P and Zn in lubricating oil, microwave digestion method was studied by using inductively coupled plasma-atomic emission spectrometry(ICP-AES). Lubricating oil was completely decomposed with nitric acid or a mixture of nitric acid and hydrogen peroxide using and closed microwave digestion system. Digestions are completed within 50 min, a factor of at least 3~4 times faster than for the conventional digestion. A gradual heating program operated by the pulsed mode was found suitable for decomposing the lubricating oil matrix safely. The proposed method of digestion gave relative standard deviations(RSD) less than 3% for the elements determined.

  • PDF

Efficient Sample Digestion Method for Uranium Determination in Soil using Microwave Digestion for Alpha Spectrometry (마이크로파 용해장치를 활용한 토양 중 우라늄의 알파분광분석법)

  • Kim, Chang Jong;Cho, Yoon Hae;Kim, Dae Ji;Chae, Jung Seok;Yun, Ju Yong
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.213-218
    • /
    • 2012
  • Alpha spectrometry has been typically used for determination of the uranium isotopes in soil. For a number of uranium analysis in soil samples, rapid sample digestion with limited quantities of mixed acid containing HF will give a contribution for effective management of uranium analysis. Microwave digestion system is evaluated for rapid sample digestion using reference uranium soil (IAEA-375 soil). For completion of 0.5 g of soil digestion by microwave, 3 ml of HF in a 10 ml of mixed acid is minimum requirement volume for completed soil digestion for 80 minutes. Microwave digestion is timely effective techniques for uranium measurement using alpha spectrometry compared to the other methods (open vessel digestion, closed vessel digestion) due to rapid sample digestion. In addition, it can be reduced the occurrence of hazardous substances by minimizing the amount of HF.

Dissolution Conditions of Solid Radioactive Wastes Generated from NPP for the Analysis of Radionuclides Using a Closed-vessel Microwave Acid Digestion System (원전 발생 고체 방사성폐기물 내 핵종 분석을 위한 극초단파 산분해 장치를 이용한 용액화 조건)

  • 표형열;이정진;전종선;이창헌;지광용
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.158-166
    • /
    • 2004
  • The optimal conditions are obtained for the decomposition of solid radioactive wastes, including ion exchange resin, zeolite, active charcoal, and sludge from nuclear power plant. In the process of decomposing the radioactive wastes were used the microwave acid digestion method with mixed acid. The solution after acid digestion by the following method was colorless and transparent. Each solution was analyzed with ICP-AES and AAS and the recovery yield for 5 different elements added the simulated radioactive wastes were over 94%. As an effective pre-treatment, the proposed microwave acid digestion conditions concerning the chemical trait of each radioactive waste are expected to be generally applied to above-mentioned radioactive wastes from nuclear power plant hereafter.

  • PDF

The Study on Pre-treatment Method of Filter for Analysing the Heavy Metals in Air Quality (대기중의 중금속 분석을 위한 여지의 전처리 방법에 관한 연구)

  • 김광래;이상칠;어수미;김민영;신재영;이재영
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.16-19
    • /
    • 2002
  • This study was carried out to establish the standardized analysis method in order to decide accurate concentrations of hazardous metals in the air. Acid decomposition method used usually was compared to microwave digestion method. Comparing results of tested background concentration in blank filter, we found that the magnitude of element concentration was Na, Ca, K, Mg, Al and Ba by order. The element concentrations of Glass fiber filter were higher than those of Quartz fiber filter, and the number of undetected components in Glass fiber filter was lower than that in Quartz fiber filter. Thus it is supposed that the concentration of background elements in Glass fiber filter was higher than those in Quartz fiber filter The extraction rate of microwave digestion method was superior to those of acid decomposition method during the test of blank filter as well as SRM of NIST. In case of the SRM of NIST, the average extraction efficiency of acid decomposition Method and microwave pretreatment is 53.8∼82.7%, 81.3∼97.1%, respectively. This result might be caused by the closed system of Microwave, which make outflow and loss of components less. Also microwave digestion method has other merits such as the minimization of time, reagents, and contamination. Furthermore, if the extraction condition, extraction time and used acids are optimized, the better results will be represented.

  • PDF

The Development of Continuous Flow Method Through Microwave Oven for the Analysis of Metal Oxides in Water by ICP-AES (ICP-AES에 의한 수중의 금속 산화물 직접분석을 위한 연속흐름 Microwave 용해장치 개발 연구)

  • Kim, Yeon Du;Lee, Gye Ho;Kim, Hyeong Seung;Kim, Dong Su;Park, Gwang Gyu
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.8
    • /
    • pp.576-584
    • /
    • 1994
  • The method described offers rapid and efficient sample preparation using on-line microwave digestion of metal oxides in water sample with direct elemental detection by ICP-AES. The open tubing digestion system(OTD) and the restraint tubing digestion system(RTD) for flow injection(FI) were designed and tested to find the optimum conditions. Comparison of OTD and RTD indicated that RTD was 3 times faster on the digestion time, and 10 times higher on sample mass. Finally, the results of RTD agree well with those by conventional microwave open vessel in all cases and show good precision; Fe and Cu show good with about 5% of RSD, while Zn and Co more or less than 10% RSD.

  • PDF

Dissolution of vanadium pentoxide using microwave digestion system for determination of vanadium by ICP-AES (ICP-AES로 바나듐 측정을 위한 마이크로파 용해 장치를 이용한 오산화바나듐 용해)

  • Choi, Kwang-Soon;Park, Yang-Soon;Kim, Yeon-Hee;Han, Sun-Ho;Song, Kyu-Seok
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.511-517
    • /
    • 2010
  • Dissolution procedure of vanadium pentoxide, which is widely used as a catalyst for production of sulfuric acid or an oxide reaction of the numerous organic compounds, was investigated. Reagent of vanadium pentoxide was completely dissolved in aqua regia-$H_2O_2$-HF solution, but plate type of vanadium pentoxide sample was not clearly dissolved with mixed acids. Thus, in order to establish the dissolution procedure for plate type of vanadium pentoxide, the solubility of vanadium pentoxide was investigated through comparison of acid treatment-fusion and microwave digestion methods. The optimized acid for dissolution of vanadium compound was found to be mixing acids of aqua regia, $H_2O_2$ and HF. Acid-fusion and microwave digestion methods have a similar property in the solubility of vanadium compound, but the latter was more quick and convenient procedure. The content of vanadium pentoxide was found to be $97.9{\pm}0.9%$ using an inductively coupled plasma atomic emission spectrometer after dissolution of a sample with the microwave digestion system.

Considerations of Acid Decomposition System for the Analysis of Heavy Metals in Packaging-grade Paper (포장용지류에서의 중금속 분석을 위한 산분해 전처리 방법의 탐색)

  • Lee, Tai-Ju;Ko, Seung-Tae;Kim, Hyoung-Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.43 no.1
    • /
    • pp.65-73
    • /
    • 2011
  • The fibrous raw materials in packaging-grade paper production in Korea were mainly obtained from waste paper. The use of recycled paper has both positive and negative impacts in papermaking process. The primary positive impacts are the environmental protection and manufacturing cost reduction, and the negative impacts are the quality reduction in paper quality and the accumulation of heavy metals and other pollutants in wet- and dry-end process. This study was carried out to consider the optimum acid decomposition system with the highest recovery rate for the analysis of heavy metals in packaging-grade paper. The open digestion system using Kjeldahl apparatus and the closed digestion system using microwave oven for decomposing the organic materials in paper were compared. In both open and closed digestion method, the combination of nitric acid, hydrochloric acid and hydrogen peroxide showed higher recovery rate than using only nitric acid alone because the presence of Cl- ions in hydrochloric acid stabilizes ligand formation with metal ions. KOCC was observed to have the highest heavy metal content among the recycled paper samples. The heavy metal contents decomposed with the closed digestion system were relatively higher than with open digestion system.

A Study on Sample Preparation for the Analysis of Trace Elements in Foods of Animal Origin by Ultra High Pressure Microwave Digestion (초고압초음파분해법을 이용한 축산물내 미량금속 잔류분석을 위한 시료전처리 방법)

  • Lee, Myoung-heon;Lee, Hee-su;Son, Seong-wan;Jung, Gab-soo;Park, Jong-myung;Kim, Sang-keun
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.3
    • /
    • pp.393-398
    • /
    • 2003
  • Simple and rapid sample preparation method for trace elements in foods of animal origin using ultra high pressure microwave digestion system (UHP/MDS) and inductively coupled plasma atomic emission spectrometer (ICP/AES) were developed. 1. For the digestion of sample using UHP-MDS, 20% nitric acid (v/v) was the most suitable solvent for the determination of trace elements in foods of animal origin. 2. The optimal digestion conditions for UHP-MDS were as follows: final temperature $180^{\circ}C$, final pressure 400 PSI, and magnetic power 900 W in the solid sample. For the liquid sample final temperature $170^{\circ}C$, final pressure 300 PSI and magnetic power 700 W were optimal conditions. 3. As result of interlaboratory test, the average recovery rate of the for solid sample were 88.3~99.1% for As, 82.4~93.3% for Cd, 89.2~101.2% for Hg and 86.5~93.8% for Pb, respectively. In liquid sample, it were 87.0~96.8% for As, 80.9~96.6% for Cd, 87.5~91.2% for Hg and 91.4~95.5% for Pb, respectively. 4. The average coefficient variation rate were 3.3~15.9% for solid sample and 2.9~10.8% for liquid sample.