• Title/Summary/Keyword: microwave absorption

Search Result 170, Processing Time 0.026 seconds

Room Temperature Ferromagnetism on Co and Fe Doped Multi-wall Carbon Nano-tube

  • Chae, K.H.;Gautam, S.;Yu, B.Y.;Song, J.H.;Augustine, S.;Kang, J.K.;Asokan, K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.171-171
    • /
    • 2011
  • Co and Fe doped multi-wall carbon nano-tubes (MWCNTs) synthesized by microwave plasma enhanced chemical vapor deposition (PECVD) technique are investigated with synchrotron radiations at Pohang Light Source (PAL) and European Synchrotron Radiation Facility (ESRF). Near edge x-ray absorption spectroscopy (NEXAFS) measurement at C K, Co $L_{3,2}$ and Fe $L_{3,2}$-edges, and x-ray magnetic circular dichroism (XMCD) at Co and Fe $L_{3,2}$-edges have been carried at 7B1 XAS KIST and 2A MS beamline, respectively, to understand the electronic structure and responsible magnetic interactions at room temperature. X-ray absorption spectroscopy (XAS) at C K-edge shows significant p-bonding and Co and Fe L-edges proves the presence of $Co^{2+}$ and $Fe^{2+}$ in octahedral symmetry. Co and Fe doped MWCNTs show good XMCD spectra at 300K. The effect on the magnetism is also studied through swift heavy ion (SHI) radiations and magnetism is found enhanced and change in the electronic structure in Co-CNTs is investigated.

  • PDF

GMI Microwave Sea Surface Temperature Validation and Environmental Factors in the Seas around Korean Peninsula (한반도 주변해 GMI 마이크로파 해수면온도 검증과 환경적 요인)

  • Kim, Hee-Young;Park, Kyung-Ae;Kwak, Byeong-Dae;Joo, Hui-Tae;Lee, Joon-Soo
    • Journal of the Korean earth science society
    • /
    • v.43 no.5
    • /
    • pp.604-617
    • /
    • 2022
  • Sea surface temperature (SST) is a key variable that can be used to understand ocean-atmosphere phenomena and predict climate change. Satellite microwave remote sensing enables the measurement of SST despite the presence of clouds and precipitation in the sensor path. Therefore, considering the high utilization of microwave SST, it is necessary to continuously verify its accuracy and analyze its error characteristics. In this study, the validation of the microwave global precision measurement (GPM)/GPM microwave imager (GMI) SST around the Northwest Pacific and Korean Peninsula was conducted using surface drifter temperature data for approximately eight years from March 2014 to December 2021. The GMI SST showed a bias of 0.09K and an average root mean square error of 0.97K compared to the actual SST, which was slightly higher than that observed in previous studies. In addition, the error characteristics of the GMI SST were related to environmental factors, such as latitude, distance from the coast, sea wind, and water vapor volume. Errors tended to increase in areas close to coastal areas within 300 km of land and in high-latitude areas. In addition, relatively high errors were found in the range of weak wind speeds (<6 m s-1) during the day and strong wind speeds (>10 m s-1) at night. Atmospheric water vapor contributed to high SST differences in very low ranges of <30 mm and in very high ranges of >60 mm. These errors are consistent with those observed in previous studies, in which GMI data were less accurate at low SST and were estimated to be due to differences in land and ocean radiation, wind-induced changes in sea surface roughness, and absorption of water vapor into the microwave atmosphere. These results suggest that the characteristics of the GMI SST differences should be clarified for more extensive use of microwave satellite SST calculations in the seas around the Korean Peninsula, including a part of the Northwest Pacific.

Determination of Arsenic, Lead and Selenium in Rice Flour by Graphite Furnace Atomic Absorption Spectrometry (흑연로원자흡수분광법에 의한 쌀분말시료중의 비소, 납, 셀레늄의 정량)

  • Cho, Kyung-Haeng;Suh, Jung-Ki
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.130-135
    • /
    • 1999
  • A graphite furnace atomic absorption spectrometry (GFAAS) with matrix modification has been used to determine trace amounts of arsenic, lead and selenium in rice flour samples. A mixed solution of palladium and magnesium nitrate was used as a matrix modifier to convert the analyte elements into a phase of higher thermostability and to increase the volatility of concomitants in graphite furnace. Matrix modification effects by the mixed solution were investigated for several elements (As, Cd, Cu, Pb, Se, Zn). It has been found that the matrix modifier substantially increase the pyrolysis and atomization temperature, and absorbance for As, Pb and Se. The concentration of As, Pb and Se in rice flour samples were determined by standard addition method with Zeeman background correction after microwave acid digestion. In this method the characteristic concentrations of As, Pb and Se are 26 ng/g, 18 ng/g, 24 ng/g on the basis of dry sample respectively.

  • PDF

Characteristics of Low Dielectric Constant SiOF Thin Films with Post Plasma Treatment Time (플라즈마 후처리 시간에 따른 저유전율 SiOF 박막의 특성)

  • 이석형;박종완
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.3
    • /
    • pp.167-272
    • /
    • 1998
  • The fluorine doped silicon oxide (SiOF) intermetal dielectric (IMD) films havc been of interest due to their lower dielectric constant and compatibility with existing process tools. However, instability issues related to hond and increasing dielectric constant due to water absorption when the SiOF film was exposured to atmospheric ambient. Therefore, the purpose nf this research is to study the effect of post oxygen plasma treatment on the resistance of nioisture absorption and reliability of SiOF film. Improvement of moisture ahsorption resistance of SiOF film is due to the forming of thin $SiO_2$ layer at the SiOF film surface. It is thought that the main effect of the improvement of moisture absorption resistance was densification of the top layer and reduction in the numher of Si-F honds that tend to associate with OH honds. However, the dielectric constant was inucased when plasma treatment time is above 5 min. In this study, therefore, it is thought that the proper plasma treatment time is 3 min when plasma treatment condition is 700 W of microwave power, 3 mTorr of process pressure and $300^{\circ}C$ of substrate temperature.

  • PDF

Optically Detected Magnetic Resonance with Nitrogen-Vacancy Spin Ensemble in Diamond

  • Lee, Hyun Joon;Shim, Jeong Hyun
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.22 no.2
    • /
    • pp.40-45
    • /
    • 2018
  • We report Optically-Detected Magnetic Resonance (ODMR) study on Nitrogen-Vacancy (NV) centers in diamond. The experiment can easily be conducted with basic optics and microwave components. A diamond crystal having a high-density NV center is suitable for the ODMR study. The magnetic field dependence of ODMR spectrum allowed us to determine the orientation of the diamond crystal. In addition, we measured the variation of the ODMR spectrum as a function of the excitation laser power. Thermal heating induced by optical absorption caused the monotonic decrease of zero field splitting. The contrast of the ODMR peak, however, increased and, then, began to decrease, indicating the optimal laser power for recording the ODMR spectrum.

The Characteristics of Electromagnetic Wave Absorption in Sintered and Composite Ni-Zn Ferrites (니켈-아연 페라이트 소결체와 복합체의 전파흡수특성)

  • 조성백;오재희
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.1
    • /
    • pp.25-30
    • /
    • 1995
  • The frequenc dependence of magnetic permeability($\mu$r) and dielectric constant($\varepsilon$r) in MHz-GHz frequency range and their relationships with microwave absorbing properties were investigated in sintered and composite Ni-Zn ferrites, respectively. It was confirmed that zero reflection condition was required the real parts of permeability and permittivity in sintered specimen, and the complex permeability, permittivity and dielectric loss tangent in composite specimen. The real part of permittivity varied with the replacement of nickel by manganese in sintered Ni-Zn ferrite. Therefore, we could control the matching frequency and matching thickness.

  • PDF

ULTRAVIOLET AND VISIBLE SPECTROSCOPIC DATABASE FOR ATOMS AND MOLECULES IN CELESTIAL OBJETS

  • Kim, Sang-J.
    • Publications of The Korean Astronomical Society
    • /
    • v.9 no.1
    • /
    • pp.111-166
    • /
    • 1994
  • I have developed a UV and visible spectroscopic database (UVSD) for atoms and molecules, which are found in interstellar medium, stars, galaxies, and in the atmospheres of the earth, planets, satellites, and comets. This UV and visible database, which is machine-readable, consists of three different sub-databases depending upon the characteristics of the sub-databases: (A) atomic and molecular line listings from laboratory observations or theoretical studies; (B) absorption spectra measured in laboratories; and (C) solar UV, visible, and infrared spectral atlases. The UVSD is in a very initial stage of development compared with other well organized and established infrared and microwave databases. In order to make a good quality and complete database, substantial efforts should be made for the acquisition of scattered important data from laboratories or institutions, and then the acquired heterogeneous data should be peer-reviewed and standardized.

  • PDF

The Comparison with SAR Patterns of Biological Objects Contacted with Coaxial Waveguide Antenna Using the FDTD Method

  • Koo, S.M.;Kwon, K.H.;Lee, C.W.;Won, C.H.;Kim, M.N.;Cho, J.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.272-275
    • /
    • 1997
  • Noninvasive multifrequency microwave radiometry using coaxial waveguide antenna has been investigated for a homogeneous and our layer human body model. We derived finite-difference time-domain(FDTD) algorithm and equation of MUR and generalized perfectly matched layer(GPML) absorbing boundary conditions(ABCs) in cylindrical coordination. The coupling between coaxial waveguide antenna and a biological object was analyzed by use of the FDTD method using MUR and GPML ABCs to obtain the absorbed power patterns in the media. The specific absorption rates(SAR) distribution which was corresponding to the temperature distribution was calculated in each region by use of the steady-state response in FDTD method. The SAR patterns of FDTD method using MUR ABCs was compared with those of FDTD method using GPML ABCs.

  • PDF

Analysis and design of traveling-wave mushroom-type electroabsorption modulator using FDTD method (FDTD를 이용한 진행파형 버섯형 전계흡수 변조기의 분석 및 설계)

  • Ok, Seong-Hae;Gong, Sun-Cheol;Choe, Yeong-Wan;Lee, Seok;U, Deok-Ha;Kim, Seon-Ho
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.156-157
    • /
    • 2001
  • 전계 흡수 광 변조기는 우수한 소광비와 낮은 전력 소모로 넓은 대역폭을 확보할 수 있으며 LD와의 단일 집적인 EML(electro-absorption modulator integrated laser diode)의 제작도 용이하므로 Microwave-Photonics 시스템에 매우 적합한 소자로써 근래에 활발한 연구가 진행되어지고 있다. 전계 흡수 광 변조기의 대역폭을 최대한 확보하기 위해서는 진행하는 마이크로파의 위상속도와 광파의 그룹 속도가 정합 되어야 하며 소자의 임피던스가 50Ω에 정합 되어야 한다. (중략)

  • PDF

SAR Pattern of Biological Objects Contacted with Coaxial Waveguide Using the FDTD Method

  • Koo, Sung-Mo;Won, Chul-Ho;Lee, Chang-Won;Cho, Jin-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.185-188
    • /
    • 1996
  • Noninvasive multifrequency microwave radiometry using coaxial waveguide antenna has been investigated for a homogeneous and four layer human body model. The coupling between coaxial waveguide antenna and a. biological object is analyzed by use of the FDTD method to obtain the absorbed power patterns in the media. The object studied in this paper is a homogeneous and four-layered lossy medium. The specific absorption rates(SAR) distribution is calculated in each region by use of the steady-state response in FDTD method.

  • PDF