• Title/Summary/Keyword: microscopic image

Search Result 199, Processing Time 0.024 seconds

A Study on Storytelling Characteristic of Super-compressed Web Drama "72 seconds" (초압축형 웹드라마 <72초>의 스토리텔링 특성 연구)

  • Jung, Wonsik
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.1148-1155
    • /
    • 2017
  • This study examined the storytelling characteristics of the super-compressed web drama "72 seconds". By analyzing all seasonal episodes of "72 seconds" and applying the various storytelling methodologies and related theories, this paper derived the main storytelling characteristics of "72 seconds" as follows. First, through the composition of the microscopic non-plot, the story value of empathy and fun is maximized, even though there is no dramatic composition compared to the general movie or drama. Second, by the specialization of everyday life, it leads to the transition from everyday experience to the new context. In other words, it provides a consensus through the cognitive expansion and interest by unfamiliarity of the ordinary experience to the audience. Third, based on the characteristics of super-compression and short theme, it utilizes fully stylistic narration like rapping. This makes the audience feel novel and further enhances the branding effect of content. And finally, based on various hybridity and variation, it uses remediation actively in all respects, especially comedy genre and comic factor.

Primary Paravertebral Low-Grade Fibromyxoid Sarcoma

  • Lee, Woo-Jin;Park, Chong-Oon;Yoon, Seung-Hwan;Chu, Young-Chae
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.5
    • /
    • pp.461-464
    • /
    • 2010
  • The authors report a 58-year-old woman with low-grade fibromyxoid sarcoma primarily located in the right paravertebral area with extension to L4 neural foramen. The patient complained lower back pain with radiating pain along the posterolateral aspect of the right lower leg. She underwent subtotal surgical removal and Cyber Knife therapy. Diagnosis was made by strikingly characteristic microscopic appearance of a bland spindle cell sarcoma which contained numerous giant collagen rosettes and was also supported by immunohistological findings. The diagnostic image findings and literatures are reviewed and discussed.

THE ADAPTIBILITY OF LIGHT-CURED GLASS-IONOMER CEMENTS TO CAVITY WALLS. (와동벽에 대한 광중합형 글래스아이오노머 시멘트의 적합도)

  • Kang, Mi-Sun;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.173-182
    • /
    • 1995
  • The purpose of this study was to evaluate the adaptability of light-cured glass ionomer cement to cavity walls. Class V cavities were prepared on the labial surfaces of extracted bovine incisor teeth. The cavities were restored with Fuji II as self-cured glass ionomer cement and Fuji II LC, Vitremer as light-cured glass ionomer cement. Fluorescent markers (fluoreceine and rhodamin B) were incorperated into liquid and primer for a better image of microscopic observation. Restored teeth were sectioned by longitudinal and labiolingual direction. The adaptability at the tooth-restoration interface was assessed incisally, axially and cervically by confocal scanning laser microscope. Following results were obtained : 1. Chemical-cured glass iomomer cement restoration showed close adaptation on the all of the cavity walls, but, cracks formed within the cement. 2. Light-cured glass ionomer cement restoration was well adapted to the cavity walls, but showed crack in the cement adjacent to axial dentinal wall. 3. There' was no significant difference in adaptability between two light-cured glass ionomer cement restorations.

  • PDF

A Micro-defect Detection of Cold Rolled Steel (냉연 강판의 미세 결함 검출 기술)

  • Yun, Jong Pil
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.4
    • /
    • pp.247-252
    • /
    • 2016
  • In this paper, we propose a new defect detection technology for micro-defect on the surface of steel products. Due to depth and size of microscopic defect, slop of surface and vibration of strip, the conventional optical method cannot guarantee the detection performance. To solve the above-mentioned problems and increase signal to noise ratio, a novel retro-schlieren method that consists of retro reflector and knife edge is proposed. Moreover dual switching lighting method is also applied to distinguish uneven micro defects and surface noise. In proposed method, defective regions are represented by a black and white pattern. This pattern is detected by a defect detection algorithm with Gabor filter. Experimental results by simulator for sample defects of cold rolled steel show that the proposed method is effective.

The Effect of the Air Temperature and Air-assisted Pressure on the Fuel Droplet Atomization (분무 공간의 공기온도와 보조공기의 공급압력이 연료입자의 미립화에 미치는 영향)

  • Kim, Y.S.;Lee, J.S.;Yoon, S.H.;Chung, S.S.;Ha, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.3 no.4
    • /
    • pp.16-24
    • /
    • 1998
  • The fuel injection type, in the gasoline engines of atomization of fuel droplet and its distribution hae influenced directly on the decision of engine performance and harmful emission. In this paper, atomization characteristics of fuel spray is investigated with microscopic visualization system. Particle motion analysis system is used to measure the SMD from fuel spray of air-assisted injector by initial factors such as temperature of ambient air and air-assisted pressure. As air-assist pressure and ambientair temperature increase, the SMD is decreased, and its variation is more stable.

  • PDF

Next Generation Fiber Length Measurement

  • Tiikkaja, Esa;Sopenlehto, Taina
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.5
    • /
    • pp.54-59
    • /
    • 2000
  • The next generation fibre size analyser has been developed in Kajaani based on over 15 years experience in fibre measurement. This new FiberLab-analyser can measure fibre length both along the fibre centre line and as projected. The cross-sectional measurements of fibre are in principle similar to the earlier version FiberLab. Measured data are generally displayed in distributions. Some new calculations have been added, for example the fibres cross sectional area and fibre volume index both available as distributions as well. The performance of the FiberLab measurement is verified against the manual microscopic testing. These tests show that the new image analysis-based measurement well matches with the manual methods.

  • PDF

Plasmodium knowlesi as a Threat to Global Public Health

  • Wesolowski, Roland;Wozniak, Alina;Mila-Kierzenkowska, Celestyna;Szewczyk-Golec, Karolina
    • Parasites, Hosts and Diseases
    • /
    • v.53 no.5
    • /
    • pp.575-581
    • /
    • 2015
  • Malaria is a tropical disease caused by protozoans of the Plasmodium genus. Delayed diagnosis and misdiagnosis are strongly associated with higher mortality. In recent years, a greater importance is attributed to Plasmodium knowlesi, a species found mainly in Southeast Asia. Routine parasitological diagnostics are associated with certain limitations and difficulties in unambiguous determination of the parasite species based only on microscopic image. Recently, molecular techniques have been increasingly used for predictive diagnosis. The aim of the study is to draw attention to the risk of travelling to knowlesi malaria endemic areas and to raise awareness among personnel involved in the therapeutic process.

Reconstruction method of confocal microscopic image for 3-dimensional analysis of uterine cervix cancer cell (자궁경부암세포의 3차원 분석을 위한 컨포컬 현미경 영상의 재구성 방법)

  • 최익환;최현주;이병일;조남훈;정구보;최흥국
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2003.05b
    • /
    • pp.242-245
    • /
    • 2003
  • 현미경을 통해 획득한 세포영상이나 조직영상은 질병의 유무나 암의 진행 정도를 파악하여 환자를 치료하기 위한 매우 중요한 요소이다. 하지만 현재 세포나 조직영상에 대한 분석은 광학현미경을 통해 얻어진 2차원 영상분석방법을 주로 이용하고 있으므로 잘린 단면의 각도나 두께에 따라 서로 다른 분석결과를 나타내는 문제점을 가지고 있다 따라서 본 연구에서는 콘포컬 현미경을 사용하여 50nm 두께의 연속적 섹션 영상을 획득한 후, 이를 바탕으로 자궁경부암세포를 3차원으로 재구성 방법을 제안한다. 본 연구의 결과는 2차원 정량분석에 대한 한계를 극복하고 정확한 진단과 예후 추정으로 환자에게 최적의 임상적 치료를 제공할 수 있는 기반을 마련하는데 활용하고자 한다

  • PDF

Biomechanical Testing of Anterior Cervical Spine Implants: Evaluation of Changes in Strength Characteristics and Metal Fatigue Resulting from Minimal Bending and Cyclic Loading

  • Kim, Sung-Bum;Bak, Koang-Hum;Cheong, Jin-Hwan;Kim, Jae-Min;Kim, Choong-Hyun;Oh, Seong-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.217-222
    • /
    • 2005
  • Objective: To achieve optimal fit of implant, it is necessary to bend the implant during spine surgery. Bending procedure may decrease stiffness of plate especially made of titanium and stainless steel. Typically titanium suffers adverse effects including early crack propagation when it is bent. We investigate whether 6 degree bending of titanium plates would decrease the stiffness after full cyclic loading by comparing with non-bending titanium plates group. Methods: Authors experimented 40 titanium alloy plates of 57mm in length, manufactured by 5 different companies. Total 40 plates were divided into two groups (20 bent plates for experimental group and 20 non-bent plates for control group). Twenty plates of experimental group were bent to 6 degree with 3-point bending technique and verified with image analyzer. Using the electron microscope, we sought for a initial crack before and after 3-point bending. Mechanical testing by means of 6000 cyclic axial-compression loading of 35N in compression with moment arm of 35mm-1.1 Nm was conducted on each plate and followed by the electron microscopic examination to detect crack or fissure on plates. Results: The stiffness was decreased after 6000 cyclic loading, but there was no statistically significant difference in stiffness between experimental and control group. There was no evidence of change in grain structure on the electron microscopic magnification. Conclusion: The titanium cervical plates can be bent to 6 degree without any crack or weakness of plate. We also assume that minimal bending may increase the resistance to fatigue fracture in cervical flexion-extension movement.

Experiment of Usefulness of IWFR Analysis for High Voltage HRTEM Images with a Series of Defocus Steps Obtained from a Relatively Thick Crystal (비교적 두꺼운 결정으로부터 얻은 일련의 비 초점 단계의 고전압 HRTEM 영상들에 대한 IWFR 분석의 유용성 실험)

  • Oh, Sang-Ho;Kim, Youn-Joong;Kim, Hwang-Su
    • Applied Microscopy
    • /
    • v.38 no.4
    • /
    • pp.363-374
    • /
    • 2008
  • In this paper we have examined the usefulness of IWFR (the iterative wave-function reconstruction) analysis for through-focal series of high-resolution images for a relative thick crystal. In the work we employed JEOL ARM 1300S, and observed the high-resolution images for a Si crystal at the two orientations of [01-1] and [11-2] having 30 nm and 35 nm thickness respectively. As a result of applying IWFR method on the images we found out that even for a thick crystal by the method we can retrieve the exit-surface wave function. However because of the strong dynamical scattering effect, the image pattern of the function reflects only qualitatively the atomic column structure of the crystal examined. Nevertheless it is no doubt that the pattern would give important clue for the crystal structure.