• Title/Summary/Keyword: microporous polyethylene membrane

Search Result 8, Processing Time 0.02 seconds

The Role of Microporous Separator in Lithium Ion Secondary Battery (리튬이온 이차전지에서의 미세다공성 격리막의 역할)

  • 이영무;오부근
    • Membrane Journal
    • /
    • v.7 no.3
    • /
    • pp.123-130
    • /
    • 1997
  • The characteristics of microporous separator for lithium ion secondary battery was introduced. Microporous separator is a key component of a lithium ion secondary battery because its basic properties were related with the performance and safety of the battery. Up to now, stretched microporous polyolefins such as polyethylene(PE) separator were mainly applied. It is still required to enhance wettability and shut-down property. For this purpose, the application of fluorovinylic polymers and surface modification of conventional polyolefinic microporous membrans we being continuously tried.

  • PDF

Optimal Condition of Microporous Membrane for Bone Marrow Stromal Cell Allotransplantation to Stimulate Wound Healing in Vitro (창상치유목적의 골수기질세포 동종이식을 위한 고분자막의 조건)

  • Lee, Eun-Sang;Kim, Myeong-Joo;Han, Seung-Kyu;Hong, Sung-Taek;Kim, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.509-518
    • /
    • 2010
  • Purpose: Major drawbacks of conventional bone marrow stromal cells (BSCs) transplantation method are mainly caused by direct transplanted cell to host cell interactions. We hypothesized that separation of the transplanted cells by a microporous membrane might inhibit most of the potential adverse effects and induce superior effect. The purpose of the study is to determine the optimal condition of the microporous membrane. Methods: First, BSCs were placed in polyethylene terephthalate (PET) transwell inserts with 3, 8, or $12{\mu}m$ pore size, and cultured in 24 well culture plates. After 5 days, bottoms of the plates were observed for presence of attached BSCs in monolayer and cell numbers were evaluated. Second, BSCs were placed PET, polycarbonate (PCT), and mixed cellulose esters (MCE) transwell inserts with 3 and $8{\mu}m$ pore size, and cultured in 24 well culture plates. After 3 days, the supernatants of the media left in culture plate were analyzed for collagen, vascular endothelial growth factor (VEGF), platelet derived growth factor BB (PDGF-BB), and basic fibroblast growth factor (bFGF). Third, BSCs were placed in 15% and 70% of the PET membrane with $3{\mu}m$ pore size. All the experimental conditions and methods were same as the second study. Results: The optimal pore sizes to prevent BSC leakage were $3{\mu}m$ and $8{\mu}m$. The amounts of type I collagen and three growth factors tested did not show significant differences among PET, PCT, and MCE groups. However, the collagen, VEGF, and bFGF levels were much higher in the high (70%) density group than in the low (15%) density group. Conclusion: This study revealed that the optimal pore size of membrane to prevent direct BSC to recipient cell contact is in between $3{\mu}m$ and $8{\mu}m$. Membrane materials and pore sizes do not influence the collagen and growth factor passage through the membrane. The most striking factor for collagen and growth factor transport is pore density of the membrane.

Electrochemical and Safety Performances of Polyimide Nano fiber-based Nonwoven Separators for Li-ion Batteries

  • Kim, Yeon-Joo;Lee, Sang-Min;Kim, Seok Hong;Kim, Hyun-Soo
    • Journal of Electrochemical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.26-33
    • /
    • 2015
  • In this study, cell performance and thermal stability of lithium-ion cells with a polyimide (PI) separator are investigated. In comparison to conventional polyethylene (PE) separator, the PI separator exhibits distinct advantage in microporous structure, leading to superior reliability of the cell. The cells with PI separator exhibit good cell performances as same as the cells with PE separator, but their reliability was superior to the cell with PE separator. Especially in the hot-box test at 150 and 180℃, PI separator showed a contraction percentage close to 0% at 150℃, while the PE separator showed a contraction percentage greater than 10% in both width and length. Therefore, the PI separator can be the promising candidate for separators of the next generation of lithium-ion battery.

Microporous Bellow Fiber Membrane Prepared from High Density Polyethylene/Ultra High Molecular Weight Polyethylene Blend (고밀도 폴리에틸렌/초고분자량 폴리에틸렌 블렌드로 제조한 미세다공성 중공사막)

  • 남주영;최승은;이광희;장문석;김진호;임순호
    • Polymer(Korea)
    • /
    • v.27 no.4
    • /
    • pp.307-312
    • /
    • 2003
  • Hollow fiber was prepared from the blend of a high density polyethylene (HDPE)/ultra high molecular weight polyethylene (UHMWPE). The changes in the morphology and mechanical property of the hollow fiber were investigated. The commercial product (Sterapore), having a high water permeability, was analyzed with viscosity measurement and FT-IR. The molecular weight of Sterapore was very high and its surface was coated with a vinyl alcohol/vinyl acetate copolymer. The content of UHMWPE in the HDPE/UHMWPE blend was limited below 10 wt%. In order to improve the dispersion of UHMWPE, a mineral oil should be introduced in the blend. The morphology and mechanical property of the hollow fiber of HDPE/UHMWPE blend were similar to those of the commercial product.

Fabrication of a High Porous Polyethylene Membrane Using BET as a Novel Diluent (새로운 BET 희석제를 이용한 고다공성 폴리에틸렌 분리막 제조)

  • Cho, Inhyun;Lee, Soomi;Kim, Chang Keun
    • Polymer(Korea)
    • /
    • v.38 no.4
    • /
    • pp.530-534
    • /
    • 2014
  • Polyethylene (PE) membranes having various porosities are used as microfilters and separators in lithium ion batteries. Membranes having a high porosity are required for use as separators in a large scale lithium ion secondary battery. In this study, BET was examined for use as a new nontoxic diluent for the fabrication of highly porous PE membranes by thermally induced phase separation process. It was confirmed that BET can be used as a new diluent for the fabrication of the PE membranes by exploring upper critical solution temperature type phase behavior of PE mixtures with BET. When the porosity of the membrane prepared from the PE/PO mixture was compared with that prepared from PE/BET mixture, the latter was about 1.8 times higher than the former.

Studies on the Secondary Battery Application of the Surface Fluorinated Microporous PE Separator Membranes (표면 불소화된 미세다공성 PE 격리막의 이차전지 적용을 위한 연구)

  • Byun, Hong-Sik;Kim, Dae-Hoon;Cho, Hyun-Il;Lee, Byung-Seong;Hong, Byung-Pyo;Lee, Sang-Yun;Nam, Sang-Yong;Seo, Myung-Su;Rhim, Ji-Won
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.75-83
    • /
    • 2008
  • In this research, the research for enhancing the stability at the mechanical strength and thermal stability and high power through the Direct Fluorination of the Polyethylene (PE, Asahi) for secondary battery was conducted. The surface of according to the fluorine gas exposure time and constructional change were observed through the scanning electron microscope image, and the contact angle. The mechanical property was confirmed through the tensile strength and surface hydrophilic property experiment. Charge and discharge experiment, the lifetime property, and the overcharge test were performed in order to confirm the electrochemical characteristic of produced and we confirmed at the high power that the stability about a temperature was improved.

Percutaneous Absorption and Model Membrane Variations of Melatonin in Aqueous-based Propylene Glycol and 2-Hydroxypropyl-$\beta$-cyclodextrin Vehicles

  • Lee, Beom-Jin;Cui, Jing-Hao;Keith A. Parrott;James W.Ayres;Robert L.Sack
    • Archives of Pharmacal Research
    • /
    • v.21 no.5
    • /
    • pp.503-507
    • /
    • 1998
  • Percutaneous absorption and model membrane variations of melationin (MT) in aqueous-based propylene glycol and $2-hydroxypropyl-{\beta}-cyclodextrin $vehicles were investigatted. the excised hairless mouse skin (HMS) and two synthetic ethylene vinyl acetate (EVA) and microporous polyethylene (MPE) were selected as a model membrane. the solubility of MT was determined by phase equilibrium study. the vertical $Franz{\circledR}$ type cell was used for diffusion study. The concentration of MT was determined using reverse phse HPLC system. The MT solubility was the highest in a mixture of PG and $2-HP{\beta}CD$. The percutaneous absorption of MT through excised HMS increased as the solubility increased. However, the permeability coefficient decreased and then slightly increased in mixture of PG and $2-HP{\beta}CD$. On the other hand, both flux and permeability coefficient through EVA membrane decreased as the solubility increased. No MT was detected over 12 h after starting diffusion through MPE membrane. The flux of MT was dependent on the type of membrane selected. Flux of MT was greatest in excised HMS followed by EBA and MPE membrane. Flux of MT through EVA membrane was 5-20 times lower when compared to excised HMS. Interestingly, volumes of donor phase when MPE membrane was used, significantly increased during the study period. the HMS might be applicable to expect plasma concentration of MT in human subjects based on flux and pharmacokinetic parameters as studied previously. the current studies may be applied to deliver MT transdermally using aqueous-based vehicles and to fabricate MT dosage forms.

  • PDF