• 제목/요약/키워드: microparticle

검색결과 128건 처리시간 0.038초

경기도 지역 임신부를 대상으로 한 풍진 항체 양성률에 대한 혈청 역학적 연구 (A Seroepidemiologic Study on Rubella Antibody in Pregnant Women in Kyonggi Do)

  • 기모란;최보율;신영전;박항배;윤배중;한중석
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권2호
    • /
    • pp.279-292
    • /
    • 1997
  • The vaccinations of susceptible children and postpubertal females are the major means to prevent congenital rubella syndrome(CRS). Another means for reducing the CRS is therapeutic abortion or fetal monitoring for women who are infected in the first four months of pregnancy. We could not estimate the incidence of CRS in Korea, because there was no surveillance system for rubella and CRS. Nationwide vaccination program for 15months infant had been started early 1980s. So, most women at childbearing age during study period were not received rubella vaccination. We set forth CRS management system for pregnant women in two rural county of Kyonggi province, Korea. In this system, the presence of rubella IgG and IgM antibodies for early pregnant women were examined with MEIA(Microparticle Enzyme Immunoassay) method by IMx automated analyzer $Abbott^(R)$. The infected pregnant women followed up in order to confirm their childrens CRS. This study was carried out from Mu. 1993 to Jun. 1994, and pregnant women examined were 874 persons. The results were summarized as follows. The overall positive .ate of rubella IgG antibody was 94.5%(826/874). The positive rate was significantly increase as the age increased, and reached 100% in pregnant women who were over 35 years old. This results suggest that a meaningful number of women are infected during childbearing years. The geometric mean titer of IgG of sero-positive subjects was significantly declined as the age increased. On the question about history of URI symptoms and rash in pregnancy, 20.7% of respondents checked on URI symptoms with .ash, 13.5% only URI symptoms without .ash, and 65.8% no symptoms. However there was no demonstrable association between the rubella like infection history in pregnancy and the rubella IgG and IgM antibody status. Rubella infection .ate in pregnant women was 0.9%(95% CI 0.4-1.8%). Two of these 8 infected pregnancies were terminated by therapeutic abortion. One of them was not followed. Five babies had no gross anomalies at birth. In Dec. 1996, three of five babies were normal appeared infants. Two of them were not followed. Throughout this study results, we confirmed the need of CRS management system for pregnant women, in Korea.

  • PDF

초임계 반용매 침전법에 의한 라이소자임이 내포된 폴리감마글루탐산의 미세입자 제조 및 특성 (Preparation and Characterization of Microparticles of $Poly(\gamma-glutamic\;acid)$ Containing Lysozyme by means of Supercritical Anti-Solvent (SAS) Precipitation Process)

  • 이동일;능운;성문희;박일현
    • 폴리머
    • /
    • 제31권2호
    • /
    • pp.168-176
    • /
    • 2007
  • 라이소자임이 내포된 폴리감마글루탐산(PGA)의 서브-마이크론 크기의 미세입자를 압력, 온도, 노즐내경, 농도 등을 변화시켜가면서 초임계 반용매 침전법 (SAS)으로 제조하였다. SAS법의 전체적인 결과는 압력이 클수록, 온도가 낮을수록, 노즐 내경이 작을수록, 농도가 묽을수록 작은 입자가 얻어졌다. FT-IR로 분석한 결과, 본래 초기의 PGA:라이소자임:50 : 50의 조성비는 SAS 공정을 거치면서 최종 분말 입자 내에서는 33 : 67로 변화하였다. 이것은 PGA가 라이소자임보다 탄산가스/디메틸설폭사이드(DMSO) 혼합용매에 더 높은 용해도를 가지기 때문인 것으로 추측된다. 또 이러한 용해도 특성 때문에 생성 입자는 핵-껍질 구조를 갖고 있으며, 핵 부분은 라이소자임이 구성하는 것으로 여겨진다. 생성된 분말 입자 내에는 $7.8\times10^{-3}wt%$의 농도로 미량의 DMSO가 잔존하고 있음이 밝혀졌다.

고분자 박막 내에 담지 된 실리카 마이크로입자의 광산란 효과에 의한 광에너지 상향전환 효율 향상 (Light Scattering-enhanced Upconversion Efficiency in Silica Microparticles-embedded Polymeric Thin Film)

  • 최현석;이학래;이명수;박정민;김재혁
    • 공업화학
    • /
    • 제30권1호
    • /
    • pp.88-94
    • /
    • 2019
  • 삼중항-삼중항 소멸에 의한 광에너지 상향전환 기술(triplet-triplet annihilation upconversion, TTA-UC)은 특정 조건을 만족시키는 유기물들의 에너지 전달 및 융합 과정에 의해 저에너지의 광자를 고에너지의 광자로 변환시키는 신개념 에너지 전환기술이다. 본 연구에서는 실리카 마이크로입자(silica microparticle, SM)를 UC가 구현되는 폴리우레탄 박막 내에 담지 시켜 입사되는 광원의 광산란 효과를 도모함으로써 TTA-UC 효율을 향상시키고, 그 기작에 대해 탐구하였다. Seeded growth method를 통하여 약 950 nm의 균일한 크기를 갖는 SM을 합성하였으며, UC 박막 내에 담지 된 SM의 농도를 증가시킴에 따라 635 nm 광원 조사 시 430-570 nm 영역에서의 UC 세기가 최대 1.64배 증가함을 확인하였다. 삼중항 lifetime 측정을 통하여 광감응제 PdTPBP와 전자수용체 perylene 간의 triplet-triplet energy transfer(TTET) 효율을 분석한 결과, 박막 내에 담지 된 SM이 chromophore 간의 TTET에 미치는 영향은 미미한 것으로 나타났다. 또한, 입사 강도-UC 세기의 상관관계를 분석하여 TTA-UC 효율을 분석한 결과, SM이 박막 내에 존재할 경우 UC 양자효율이 최대 1.5배 향상됨을 확인하였다.

3D 프린터를 활용한 맞춤형 휴대용 형광측정 장치 개발 (Development of Customizable Fluorescence Detection System using 3D Printer)

  • 조경래;서정혁;최세운
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2019년도 춘계학술대회
    • /
    • pp.278-280
    • /
    • 2019
  • 유세포 분석법은 단일 세포나 미세 입자에 대한 다양한 광학적 특성을 측정하여 이를 매개 변수로 나타내는 측정법이다. 이러한 매개 변수에는 세포의 크기, 입상도, 형광 강도 등이 있으며 이는 세포와 광원에서 조사한 빛의 물리적이며 광학적인 상호 작용에 의해 방사되는 빛에 따라 결정된다. 하지만 유세포 분석법은 고가이며 크기가 크고 다양한 형광염료의 사용이 제한적이라는 단점이 있다. 또한, 측정할 수 있는 다양한 데이터에 비해 사용자가 원하고자 하는 데이터는 한정적일 수도 있다. 이러한 특징은 비용/공간적으로 제한적인 연구 환경을 가진 연구자에게 있어서 어려운 점으로 다가오고 있다. 이에 본 연구는 소형의 발광다이오드와 포토다이오드를 이용하여 저가의 휴대용 형광측정 장치를 개발하고자 한다. 이는 누구나 제작하기 쉽도록 3D 프린터로 설계되었으며 광원과 필터 그리고 광센서의 교체가 가능하도록 설계하여 표적 세포 및 형광염료의 다양한 선택이 가능하다. 제안된 형광측정 장치를 통하여 형광처리가 된 세포를 다양한 세포 수로 분류하여 측정하였으며 그 결과, 측정된 형광의 세기가 세포의 농도에 따라 비례한 것을 보였으며 또한 높은 선형성을 보여주었다.

  • PDF

25 Vitamin D3 측정에 있어서 화학발광미세입자 측정법과 화학발광면역 측정법 간의 비교 및 고찰 (Comparison between the method of the measurement 25 Vitamin D3)

  • 김대원;이정희;정안나;서소연
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.112-114
    • /
    • 2015
  • Purpose Vitamin D to Anti- Rickets both steroid compounds showing activity, By acting on bone tissue secretary and the key to maintain serum Ca homeostasis. The blood level of vitamin D is the largest in D3 that the concentration of the metabolite is reflected in the holding state of vitamin D in vivo. Sunlight to change the 7-dehydrocholesterol in the skin and through the skin to D3, In the liver in combination with the D2 and D3 D4 changes. The Radioimmunoassay(RIA) method is measuring the D 3, the sensitivity can be measured also difficult trace substance to measure the normal test because it is very sensitive, but recently, a check is possible, for the Total D3 in Chemimicroparticle immunoassay(CMIA) or Chemiluminescent immunoassay(CLIA) measuring using microparticle RIA and CMIA(Architect i2000SR) / use the CLIA(DXI-800) method to compare and evaluate the correlation between the tests in the same test items. Materials and Methods Commissioned from January 2014 to March 2015 patients were enrolled in a total of 273 people. 29 out of 273 people conducted by RIA were compared with CMIA, 244 patients were compared with CLIA. Using reagents and equipment were used RIA(Diasource), CMIA(Architect i2000SR, Abbott Diagnostics) / CLIA( Unicel DXi-800, Beckman coulter). Results Correlation of the RIA and CLIA was a R2 = 0.1844 (y = 0.7303x + 3.9005), and the correlation of RIA CMIA is R2 = 0.2762 (y = 0.8862x + 4.56) respectively. (According to statistics, during the same period RIA is Deficiency 4.31%, Insufficiency 90.53%, Sufficiency 5.16%, was Excess 0%, CLIA / CMIA is Deficiency 17.02%, Insufficiency 75.91%, Sufficiency 7.03%, indicating the distribution of 0.03 % Excess) Conclusion Serum vitamin D and parathyroid hormone that show an inverse relationship, the level above which are not parathyroid hormone and vitamin D reduced the increase. The density is different for each study, at most 20 is reported to be the maximum between 30 ng / ml. In Korea it requires a proposed standard of vitamin D deficiency, reference to the WHO lack the case more than 10ng/ml, 20ng/ml and defined by the lack of, if not more than, the IOM, but looking at 12ng/ml or less to the normal to lack, at least 20ng/ml, the reference do not match the deficit under 20ng/ml, 21-29ng/ml relative lack between, was also defined as a sufficient condition for more than 30ng/ml. Although not statistically is between RIA and CLIA two ways to vitamin D levels change according to season match, when seasonally seen in summer as commonly known (April to September), winter (October to March) relative to the increase measured than it was found. Finally, the study on the correlation between the two methods have been expected to result in a consistent and apply the same view high reference value on the graph is difficult. However, there may be differences between the test equipment and methods, and could be especially the case of RIA method using an organic solvent is difficult to compare different methods and correlated view similar trend in vitamin D deficiency and quarterly aspect ratio.

  • PDF

국내에서 2005년에 실시한 연령별 A형 간염 바이러스 항체 보유율 (Age Related Prevalence of Antibodies to Hepatitis A Virus, Performed in Korea in 2005)

  • 최혜진;이수영;마상혁;김종현;허재균;강진한
    • Pediatric Infection and Vaccine
    • /
    • 제12권2호
    • /
    • pp.186-194
    • /
    • 2005
  • 목 적 : A형 간염의 발생이 2000년대부터는 1990년대에 청소년과 젊은 성인에서 발생이 높았던 것과는 달리 20대부터 30대 초반의 젊은 성인 환자가 증가되는 추세를 보이며 소규모이기는 하나 집단적 돌발유행이 발생되는 변화가 있으며, 더불어 1990년대에 시행되었던 A형 간염 항체 보유율 역학연구가 2000년대에 와서 이루어지지 않고 있는 실정이다. 이런 상황에서 저자들은 최근 국내 A형 간염의 역학적 변화의 원인분석과 이에 따른 예방대책의 기초 자료로 활용하기 위하여 연령별 A형 간염 항체 보유율 역학연구를 실시하게 되었다. 방 법 : 2005년 1월부터 6월까지 가톨릭대학교 성모자애병원 및 마산파티마병원에 내원한 외래 방문자, 건강 검진자 및 입원 환자에서 과거에 A형 간염에 이환된 병력과 가족 내 발생이 없고 A형 간염 백신 접종력이 없는 출생 후부터 50세까지 연령의 소아와 성인 1,301명(남자 655명, 여자 646명)을 대상으로 A형 간염 항체 검사를 실시하였다. 동시에 성별비교와 두 지역간의 통계적 유의성을 검토하였다. 결 과 : 항체 보유율은 1세 미만에서 61.1%, 1세 부터 5세의 연령군에서 30.5%, 6세에서 10세 사이 연령군에서 14.6%, 11세에서 15세 사이 연령군에서 1.7%, 16세에서 20세 사이 연령군에서 6.5%, 21세에서 30세 사이 연령군에서 36.6%, 31세에서 40세 사이 연령군에서 77.5%, 41세에서 50세 사이 연령군에서 99.8%의 항체 보유율을 확인하였다. 그리고 연령군에서 남녀간의 통계적 유의성은 없었으나, 두 지역에서 6세부터 10세 사이 연령군에서 통계적으로 유의한 차이를 확인하였다. 결 론 : 16세에서 30세 사이 연령의 항체 보유율이 1990년대에 비해 현저히 낮아진 것을 확인하였고 이로 인하여 이들 연령에서 A형 간염 발생이 지속적으로 높아질 것과 집단적 돌발유행의 가능성이 있어 향후에도 이와 관련된 광범위 역학연구가 필요하다. 더불어 지역간에도 연령에 따른 항체 보유율이 달라 지역간 역학 비교연구가 필요하다.

  • PDF

자성 미세입자에의 항체 고정화 방법이 면역결합반응에 미치는 영향 (Effect of Antibody Immobilization Method to Magnetic Micro Beads on its Immunobinding Characteristics)

  • 최효진;황상연;장대호;조형민;강정혜;성기훈;주재범;이은규
    • Korean Chemical Engineering Research
    • /
    • 제44권1호
    • /
    • pp.65-72
    • /
    • 2006
  • 자력을 이용한 분리기술의 장점을 이용하여 여러 가지 불순물들이 섞여 있는 현탁 용액으로부터 자성입자를 이용하여 목적 단백질만을 얻어낼 수 있는 기술의 가능성에 대하여 알아보고자 하였다. 자성입자를 이용하는 경우에는 (1) 자성입자 표면에 리간드 고정화, (2) ligand(리간드)와 목적 물질과의 특이적 결합, (3) 자력을 이용한 자성입자의 분리, (4) 목적 물질의 탈착 그리고 (5) 자성입자의 재사용 순서로 진행되어 여러 단계의 공정을 단순화시킬 수 있다. 이러한 자성입자를 이용한 방법은 효율성, 단순성, 까다롭지 않은 조건, 자동화의 용이성, 비용의 저렴함으로 인해 관심이 증대되고 있다. 본 연구에서는 표면이 카르복실기로 처리된 자성입자에 IgG 항체를 고정화시킨 후 IgG를 목적 단백질로 하여 이를 분리해내고자 하였다. 이를 위하여 자성입자 표면에 다른 물질과의 비특이적 결합이 일어나지 않을 조건에 대하여 확인해 보았으며, IgG 항체를 배향성 고정화시켜 자성입자가 목적 단백질과 보다 효과적으로 결합하여 목적 단백질인 IgG만을 선택적으로 분리해 낼 수 있는지에 대하여 알아보았다. 높은 pH를 사용할 경우 비특이적 흡착을 줄일 수 있었으며, IgG 항체 고정화된 자성입자를 사용할 경우 목적 단백질인 IgG와 선택적으로 반응함을 알 수 있었다. IgG 항체의 고정화에서 Fc지역 C-terminus에 인접해 있는 탄수화물 부분을 이용하여 배향성을 준 경우, IgG 항체 내의 아민기와 고정화시키는 비배향성 고정화 방법보다 항원과의 결합능력이 약 2배 높았다.

항 바이러스 치료중인 B형 간염환자에서 HBeAg 및 HBV DNA 검출에 관한 분석 (Analysis of HBeAg and HBV DNA Detection in Hepatitis B Patients Treated with Antiviral Therapy)

  • 천준홍;채홍주;박미선;임수연;유선희;이선호
    • 핵의학기술
    • /
    • 제23권1호
    • /
    • pp.35-39
    • /
    • 2019
  • [목적] B형 간염바이러스(hepatitis B virus, HBV)감염은 전세계적으로 중요한 공중 보건 문제이며 만성간염, 간 경변, 간암의 주요 원인으로 알려져 있으며, 이러한 질환의 진단 및 치료에 B형 간염바이러스의 혈청학적 검사는 필수적이다. 항 바이러스 치료중인 B형 간염 환자를 대상으로 면역방사계수 측정법(IRMA; Immunoradiometric assay)과 화학발광 미세입자 면역분석법(CMIA; Chemiluminescent Micropartical Immunoassay)을 이용하여 HBe-Ag 검사를 시행하였고, 실시간 중합효소 연쇄반응(RT-PCR; Realtime-Polymerase Chain Reaction)법을 이용하여 혈청 내 HBV DNA 검출율 을 비교 분석 하였다. [대상 및 방법] 항 바이러스 치료가 시행중인 B형 간염 환자 270명을 대상으로 HBeAg 혈청 검사와 HBV DNA 정량 검사를 실시하였다. HBeAg 혈청 검사는 검출 원리가 다른 두 가지 혈청학적 검사법(IRMA, CMIA)을 적용 하였고, 혈청 내 HBV DNA는 Abbott m2000 System을 사용하여 실시간 중합효소 연쇄반응(RT-PCR; Realtime-Polymerase Chain Reaction)법으로 정량 측정 하였다. [결과] HBeAg 검출율은 면역방사계수법(IRMA)의 경우 24.1% (65/205), 화학발광 미세입자 면역 분석법(CMIA)에서는 82.2% (222/48)의 결과를 보였다. 혈청학적 검사방법(IRMA, CMIA)에 따른 HBeAg 검사결과의 일치율은 33% (89/270)이다. 실시간 중합효소 연쇄반응(RT-PCR)을 이용한 혈청 내 HBV DNA의 검출율은 29.3% (79/191)를 보였고, 혈청 내 HBV-DNA 농도는 $16IU/mL{\times}1.0{\times}10^9IU/mL$ 이며 검출한계는 <15IU/mL 이다. 면역방사계수법(IRMA)으로 HBeAg 검출결과가 양성일때 55.4%, 그리고 음성일때 20.9%의 HBV DNA 검출율과 $1.1{\times}10^8IU/mL$, $5.7{\times}10^5IU/mL$의 혈청내 HBV DNA농도를 나타냈다. 이에 반해 화학발광 미세입자 면역 분석법(CMIA)의 경우 HBeAg 검출결과가 양성일때 HBV DNA 검출율은 28.4%, 음성일때 33.3%의 결과를 나타냈으며 혈청 내 HBV DNA농도는 $6.0{\times}10^7IU/mL$, $2.4{\times}10^5IU/mL$ 이었다. 면역방사계수법과 화학발광 미세입자 면역 분석법에서 동일하게 HBeAg 검출 결과가 양성인 경우 HBV DNA 검출율은 62.3%의 결과를 보였으며, 혈청 내 HBV DNA 농도는 $1.1{\times}10^8IU/mL$ 이다. [결론] 혈청학적 검사법에 따른 HeAg 검출율은 많은 차이를 보였다. 이러한 차이는 검사kit에 사용된 Ab의 특성과 epitope, HBV의 genotype등 여러 가지 원인으로 생각된다. 혈청학적 검사 결과로 분류 된 그룹별 HBV DNA의 검출율과 농도를 비교한 결과, Group II(IRMA 양성, CMIA 양성, N=53)에서 높은 검출율과 농도를 확인할 수 있었다.