• Title/Summary/Keyword: micromachining

Search Result 493, Processing Time 0.022 seconds

Thermal Characteristics of Microheater for Gas Sensors (가스센서용 마이크로 히터의 발열특성)

  • Choi, Woo-Chang;Choi, Hyek-Hwan;Kwon, Tae-Ha;Lee, Myong-Kyo
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.356-363
    • /
    • 1998
  • Using the results analyzed by FEM(Finite Element Method). the microheaters with the stress-balanced $Si_3N_4$(150 nm)/$SiO_2$(300 nm)/$Si_3N_4$(150 nm) diaphragms were fabricated by silicon micromachining techniques. Pt was used as microheater materials. Pt temperature sensor was fabricated to measure the temperature of microheaters. Resistance of temperature sensor and power dissipation of microheater were measured and calculated at the various temperatures. The thermal distribution of heater was examined by a IR thermoviewer. Measured and simulated results are compared and analyzed. The temperature coefficient of resistance of heater was about $0.00379/^{\circ}C$. Pt heater showed the power dissipation of about 51 mW at $300^{\circ}C$ and a uniform thermal distribution on the surface.

  • PDF

Micromachined ZnO Piezoelectric Pressure Sensor and Pyroelectric Infrared Detector in GaAs

  • Park, Jun-Rim;Park, Pyung
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.2
    • /
    • pp.239-244
    • /
    • 1998
  • Piezoelectric pressure sensors and pyroelectric infrared detectors based on ZnO thin film have been integrated with GaAs metal-semiconductor field effect transistor (MESFET) amplifiers. Surface micromachining techniques have been applied in a GaAs MESFET process to form both microsensors and electronic circuits. The on-chip integration of microsensors such as pressure sensors and infrared detectors with GaAs integrated circuits is attractive because of the higher operating temperature up to 200 oC for GaAs devices compared to 125 oC for silicon devices and radiation hardness for infrared imaging applications. The microsensors incorporate a 1${\mu}$m-thick sputtered ZnO capacitor supported by a 2${\mu}$m-thick aluminum membrane formed on a semi-insulating GaAs substrate. The piezoelectric pressure sensor of an area 80${\times}$80 ${\mu}$m2 designed for use as a miniature microphone exhibits 2.99${\mu}$V/${\mu}$ bar sensitivity at 400Hz. The voltage responsivity and the detectivity of a single infrared detector of an area 80${\times}$80 $\mu\textrm{m}$2 is 700 V/W and 6${\times}$108cm$.$ Hz/W at 10Hz respectively, and the time constant of the sensor with the amplifying circuit is 53 ms. Circuits using 4${\mu}$m-gate GaAs MESFETs are fabricated in planar, direct ion-implanted process. The measured transconductance of a 4${\mu}$m-gate GaAs MESFET is 25.6 mS/mm and 12.4 mS/mm at 27 oC and 200oC, respectively. A differential amplifier whose voltage gain in 33.7 dB using 4${\mu}$m gate GaAs MESFETs is fabricated for high selectivity to the physical variable being sensed.

  • PDF

3D Lithography using X-ray Exposure Devices Integrated with Electrostatic and Electrothermal Actuators

  • Lee, Kwang-Cheol;Lee, Seung S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.2 no.4
    • /
    • pp.259-267
    • /
    • 2002
  • We present a novel 3D fabrication method with single X-ray process utilizing an X-ray mask in which a micro-actuator is integrated. An X-ray absorber is electroplated on the shuttle mass driven by the integrated micro-actuator during deep X-ray exposures. 3D microstructures are revealed by development kinetics and modulated in-depth dose distribution in resist, usually PMMA. Fabrication of X-ray masks with integrated electrothermal xy-stage and electrostatic actuator is presented along with discussions on PMMA development characteristics. Both devices use $20-\mu\textrm{m}$-thick overhanging single crystal Si as a structural material and fabricated using deep reactive ion etching of silicon-on-insulator wafer, phosphorous diffusion, gold electroplating, and bulk micromachining process. In electrostatic devices, $10-\mu\textrm{m}-thick$ gold absorber on $1mm{\times}1mm$ Si shuttle mass is supported by $10-\mu\textrm{m}-wide$, 1-mm-long suspension beams and oscillated by comb electrodes during X-ray exposures. In electrothermal devices, gold absorber on 1.42 mm diameter shuttle mass is oscillated in x and y directions sequentially by thermal expansion caused by joule heating of the corresponding bent beam actuators. The fundamental frequency and amplitude of the electrostatic devices are around 3.6 kHz and $20\mu\textrm{m}$, respectively, for a dc bias of 100 V and an ac bias of 20 VP-P (peak-peak). Displacements in x and y directions of the electrothermal devices are both around $20{\;}\mu\textrm{m}$at 742 mW input power. S-shaped and conical shaped PMMA microstructures are demonstrated through X-ray experiments with the fabricated devices.

Preparation of Low-Temperature Fired PZT Thick Films on Si by Screen Printing

  • Cheon, Chae-Il;Lee, Bong-Yeon;Kim, Jeong-Seog;Bang, Kyu-Seok;Kim, Jun-Chul;Lee, Hyeung-Gyu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.2
    • /
    • pp.20-23
    • /
    • 2003
  • Piezoelectric powder with the composition of PbTiO$_3$-PbZrO$_3$-Pb(Mn$\_$1/3/Nb$\_$2/3/)O$_3$ and small particle size of 0.3 $\mu\textrm{m}$ was investigated for low-temperature firing of PZT thick films. PbTiO$_3$-PbZrO$_3$-Pb(Mn$\_$1/3/Nb$\_$2/3)O$_3$ ceramics showed dense microstructure and superior piezoelectric properties, electromechanical coupling factor (k$\_$p/) of 0.501 and piezoelectric constant (d$\_$33/) of 224. The PZT paste was made of the powder and organic vehicles, and screen-printed on Pt(450nm)/YSZ(110nm)/SiO$_2$(300nm)/Si substrates and fired at 800∼900$^{\circ}C$. Any interface reaction between the PZT thick film and the bottom electrode was not observed in the PZT thick films. The PZT thick film fired at 800$^{\circ}C$ showed moderate electrical properties, the remanent polarization(p$\_$r/) of 16.0 ${\mu}$C/$\textrm{cm}^2$, the coercive field(E$\_$c/) of 36.7 ㎸/cm, and dielectric constant ($\varepsilon$$\_$r/) of 531. Low-temperature sinterable piezoelectric composition and high activity of fine particles reduced the sintering temperature of the thick film. This PZT thick film could be utilized for piezoelectric microactuators or microsensors that require Si micromachining technology.

Development of Analysis Model for Down Scaled Two Phase Catalytic Reactor (초소형 촉매 이상 분해 반응기 해석 모델 개발)

  • Lee, Dae-Hoon;Kwon, Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.1
    • /
    • pp.24-30
    • /
    • 2004
  • Analysis model for the two-phase catalytic reactor is presented. With the progress in development of micro thermofluidic devices, needs fur understanding of the phenomena in two phase reaction in cm scale has been arisen. To investigate thermal and reactive performance of down scaled two phase reactor simple analysis model that is a kind of lumped flow model is proposed. Analysis model presented is based on the experiment on mm scale model reactor. Target experiment is catalytic decomposition of 70wt% hydrogen peroxide with existence of perovskite L $a_{0.8}$S $r_{0.2}$Co $O_3$ catalyst. It is composed of balance equations of mass and energy. Each phase is considered to be a species fur the simplicity. Axial diffusion and transversal distribution of properties are neglected. Two phase catalytic reaction is modeled as successive gasification of liquid lump around catalyst and reaction in gas phase. Heat transfer is modeled by model function ofNu number. Modeled Nu is expressed as Nu=N $u_{0}$ (1+ $a_1$( $a_2$ $T^{-}$ $a_3$)exp( $a_4$ $T^{-1}$)exp( $a_{5}$ z). Transfer coefficients are determined by the comparison of experimental results. With the model, heat transfer characteristics are investigated. Also by the mass transfer coefficient, characteristics in mass transfer is investigated. With the result basic understanding on design and analysis of mm scale two-phase reactive device is obtained. Also it can be further applied to micro scale reactive device fabricated by micromachining.ing..

Air-Bridge Interconnected Coplanar Waveguides Fabricated on Oxidized Porous Silicon(OPS) Substrate for MMIC Applications (산화된 다공질 실리콘 기판 위에 제작된 MMIC용 Air-Bridge Interconnected Coplanar Waveguides)

  • Sim, Jun-Hwan;Gwon, Jae-U;Park, Jeong-Yong;Lee, Dong-In;Kim, Jin-Yang;Lee, Hae-Yeong;Lee, Jong-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.4
    • /
    • pp.19-25
    • /
    • 2002
  • In this paper, to improve the characteristics of a transmission line on silicon substrate, we fabricated air-bridge interconnected CPW transmission line on a 10-${\mu}{\textrm}{m}$-thick oxidized porous silicon(OPS) substrate using surface micromachining. Air-bridge interconnected CPW of S-W-S = 30-80-30 ${\mu}{\textrm}{m}$has insertion loss of -0.25 ㏈ and return loss of -28.9 ㏈ at 4㎓ And return loss of CPW with stepped compensated air-bridge(S-W-S : 30-100-30 ${\mu}{\textrm}{m}$) is improved -0.98㏈ at 4㎓. The results indicate that the thick OPS provides an approach to incorporate high performance, low cost microwave and millimeter wave circuits in a high-resistivity silicon-based process.

Experimental Investigation for Ablation Characteristics of Polyimide Layer and Cu-metal Layer using High Power Nd:YAG UV Laser (고출력 Nd:YAG UV레이저를 이용한 polyimide층과 Cu-metal층의 가공상태에 대한 실험적 고찰)

  • Choi, Kyung-Jin;Lee, Young-Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.4
    • /
    • pp.31-36
    • /
    • 2009
  • In this paper, the laser cutting characteristics of the flexible PCB using high power Nd:YAG UV laser were investigated. A specific FPCB model was selected for the experiment. Test sheets were made, which had equal materials and layer structure to those of the outline (OL) region and the contact pad (CP) region in the FPCB. The experiment is made up of two stages. In the first stage of the experiment, the laser cutting fluence was found, which is the threshold fluence to cut the test sheets completely. The laser cutting fluence of the OL sheet is $1781.26{\sim}1970.16\;J/cm^2$ and that of the CP sheet is $2109.34{\sim}2134.34\;J/cm^2$. In the second stage, cutting performance and its qualities were analyzed by the experiment. The laser cutting performance remained almost unchanged for all laser and process parameter sets. The average cutting width (top side/bottom side) of the OL sheet was $40.45\;{\mu}m/11.52\;{\mu}m$ and that of the CP sheet was $22.14\;{\mu}m/10.93\;{\mu}m$. However, the laser cutting qualities were different according to the parameters. The adjacent region of the cutting line on the OL sheet was carbonized as the beam speed was low and the overlap coefficient was high. The surface quality around the cutting line of the CP sheet was about the same. Carbonization and debris occurred on the surface of the cutting line. As a result of the experiment, the cutting qualities were better as the overlap coefficient was made low and beam speed high. Therefore, the overlap coefficient 2 or 3 is proper for the FPCB laser cutting.

  • PDF

A Novel z-axis Accelerometer Fabricated on a Single Silicon Substrate Using the Extended SBM Process (Extended SBM 공정을 이용하여 단일 실리콘 기판상에 제작된 새로운 z 축 가속도계)

  • Ko, Hyoung-Ho;Kim, Jong-Pal;Park, Sang-Jun;Kwak, Dong-Hun;Song, Tae-Yong;Cho, Dong-Il;Huh, Kun-Soo;Park, Jahng-Hyon
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.101-109
    • /
    • 2004
  • This paper presents a novel z-axis accelerometer with perfectly aligned vertical combs fabricated using the extended sacrificial bulk micromachining (extended SBM) process. The z-axis accelerometer is fabricated using only one (111) SOI wafer and two photo masks without wafer bonding or CMP processes as used by other research efforts that involve vertical combs. In our process, there is no misalignment in lateral gap between the upper and lower comb electrodes, because all critical dimensions including lateral gaps are defined using only one mask. The fabricated accelerometer has the structure thickness of $30{\mu}m$, the vertical offset of $12{\mu}m$, and lateral gap between electrodes of $4{\mu}m$. Torsional springs and asymmetric proof mass produce a vertical displacement when an external z-axis acceleration is applied, and capacitance change due to the vertical displacement of the comb is detected by charge-to-voltage converter. The signal-to-noise ratio of the modulated and demodulated output signal is 80 dB and 76.5 dB, respectively. The noise equivalent input acceleration resolution of the modulated and demodulated output signal is calculated to be $500{\mu}g$ and $748{\mu}g$. The scale factor and linearity of the accelerometer are measured to be 1.1 mV/g and 1.18% FSO, respectively.

Development of micro check valve with polymer MEMS process for medical cerebrospinal fluid (CSF) shunt system (Polymer MEMS 공정을 이용한 의료용 미세 부품 성형 기술 개발)

  • Chang, J.K.;Park, C.Y.;Chung, S.;Kim, J.K.;Park, H.J.;Na, K.H.;Cho, N.S.;Han, D.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.1051-1054
    • /
    • 2000
  • We developed the micro CSF (celebrospinal fluid) shunt valve with surface and bulk micromachining technology in polymer MEMS. This micro CSF shunt valve was formed with four micro check valves to have a membrane connected to the anchor with the four bridges. The up-down movement of the membrane made the CSF on & off and the valve characteristic such as open pressure was controlled by the thickness and shape of the bridge and the membrane. The membrane, anchor and bridge layer were made of the $O_2$ RIE (reactive ion etching) patterned Parylene thin film to be about 5~10 microns in thickness on the silicon wafer. The dimension of the rectangular nozzle is 0.2*0.2 $\textrm{mm}^2$ and the membrane 0.45 mm in diameter. The bridge width is designed variously from 0.04 mm to 0.12 mm to control the valve characteristics. To protect the membrane and bridge in the CSF flow, we developed the packaging system for the CSF micro shunt valve with the deep RIE of the silicon wafer. Using this package, we can control the gap size between the membrane and the nozzle, and protect the bridge not to be broken in the flow. The total dimension of the assembled system is 2.5*2.5 $\textrm{mm}^2$ in square, 0.8 mm in height. We could precisely control the burst pressure and low rate of the valve varing the design parameters, and develop the whole CSF shunt system using this polymer MEMS fabricated CSF shunt valve.

  • PDF

A Surface-micromachined Tunable Microgyroscope (주파수 조정가능한 박막미세가공 마이크로 자이로)

  • Lee, Ki-Bang;Yoon, Jun-Bo;Kang, Myung-Seok;Cho, Young-Ho;Youn, Sung-Kie;Kim, Choong-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1968-1970
    • /
    • 1996
  • We investigate a surface-micromachined polysilicon microgyroscope, whose resonant frequencies are electrostatically-tunable after fabrication. The microgyroscope with two oscillation nudes has been designed so that the resonant frequency in the sensing mode is higher than that in the actuating mode. The microgyroscope has been fabricated by a 4-mask surface-micrormachining process, including the deep RIE of a $6{\mu}m$-thick LPCVD polycrystalline silicon layer. The resonant frequency in the sensing mode has been lowered to that in actuating mode through the adjustment of an inter-plate bias voltage; thereby achieving a frequency matching at 5.8kHz under the bias voltage of 2V in a reduced pressure of 0.1torr. For an input angular rate of $50^{\circ}/sec$, an output signal of 20mV has been measured from the tuned microgyroscope under an AC drive voltage of 2V with a DC bias voltage of 3V.

  • PDF