• Title/Summary/Keyword: microgroove

Search Result 16, Processing Time 0.016 seconds

A Study on Fabrication of Hydrophobic Modification on the Surface of Copper using 355nm-Pulsed Laser (355nm 펄스 레이저를 이용한 구리 표면의 소수성 개질에 관한 연구)

  • Yun, Dan Hee;Kang, Bo Seok;Park, Jun Han;Gwak, Cheng Yeol;Shin, Bo Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.101-105
    • /
    • 2016
  • Recently, the hydrophobic surface has been attracted because of the excellent opto-physical properties. Various processing methods such as chemical, mechanical, photolithographic and laser processing are competitively introduced for fabrication of hydrophobic surface of polymer, metal and ceramics. In this paper, we fabricated the hydrophobic surface of copper metal by simple method which irradiated 355 nm UV-pulsed laser in order to shape microgrooves and increased surface roughness through oxidation process at room temperature. Finally the contact angle is dramatically increased by maximum $45^{\circ}$, as a result of oxidation which simply created nanostructures on the microstructures without expensive chemical process.

Characteristic of EP-MAP for Deburring of Microgroove using EP-MAP (전해-자기 복합 가공을 이용한 미세 그루브형상의 가공 특성에 관한 연구)

  • Kim, Sang Oh;Son, Chul Bae;Kwak, Jae Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.313-318
    • /
    • 2013
  • Magnetic abrasive polishing is an advanced deburring process for nonmagnetic materials and micropattern products that have non-machinability characteristics. Despite these advantages, there are some problems with using MAP for deburring. MAP has introduced geometric errors into microgrooves because of an over-cutting force caused by uncontrolled magnetic abrasives in the MAP tool. Thus, in this study, to solve this problem, an EP (electrolyte polishing)-MAP hybrid polishing process was developed for deburring microgrooves in an STS316 material. In addition, an evaluation of EP-MAP for the deburring of microgrooves was carried out by profiling the burrs. The results of the experiment showed geometric errors after the deburring process using MAP. However, in the case of EP-MAP, no geometric error was observed after the process because of the lower material removal rate in EP-MAP.

SURFACE MICROGROOVES OF THIRTY MICROMETERS IN WIDTH ON TITANIUM SUBSTRATA ENHANCE PROLIFERATION AND ALTER GENE EXPRESSION OF CULTURED HUMAN GINGIVAL FIBROBLASTS

  • Lee, Suk-Won;Kim, Su-Yeon;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.787-794
    • /
    • 2007
  • Statement of problem. Surface microgrooves on Ti substrata have been shown to alter the expression of genes responsible for various biological activities of cultured fibroblasts. However, their effect on enhancing cell proliferation is not yet clear. Purpose. The purpose of this study was to determine the dimension of surface microgrooves on Ti substrata that enhances proliferation and alters gene expression of cultured human gingival fibroblasts. Material and methods. Commercially pure Ti discs with surface microgrooves of monotonous $3.5{\mu}m$ in depth and respective 15 and $30{\mu}m$ in width were fabricated using photolithography and used as the culture substrata in the two experimental groups in this study (TiD15 and TiD30), whereas the smooth Ti was used as the control substrata (smooth Ti group). Human gingival fibroblasts were cultured on the three groups of titanium substrata and the proliferation, DNA synthesis, and gene expression of theses cells were analyzed and compared between all groups using XTT assay, BrdU assay, and reverse transcriptase-polymerase chain reaction (RT-PCR), respectively. Results. From the XTT assay at 48 h incubation, the proliferation of human gingival fibroblasts in TiD30 was significantly enhanced compared to that in smooth Ti and TiD15. The results from the BrdU assay showed that, at 24 h incubation, the DNA synthesis was significantly enhanced in TiD30 compared to that in smooth Ti. In RT-PCR, increase in the expression of PCR transcripts of fibronectin, CDK6, $p21^{cip1}$ genes was noted at 48h incubation. Conclusion. Surface microgrooves $30{\mu}m$ in width and $3.5{\mu}m$ in depth on Ti substrata enhance proliferation and alter gene expression of cultured human gingival fibroblasts.

The influence of Collar design on peri-implant marginal bone tissue (Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향)

  • Kim, Jee-Hwan;Jung, Moon-Kyou;Moon, Hong-Suk;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Statement of problem: Peri-implant marginal bone loss is an important factor that affects the success of implants in esthetics and function. Various efforts have been made to reduce this bone loss by improving implant design and surface texture. Previous studies have shown that early marginal bone loss is affected by implant neck designs. Purpose: The purpose of this study was to examine the influence of laser microtexturing of implant collar on peri-implant marginal bone loss. Materials and methods: Radiographical marginal bone loss was examined in patients treated with implant-supported fixed partial dentures. Marginal bone level was examined with 101 implant fixtures installed in 53 patients at three periods(at the time of implantation, prosthetic treatment and 6-month after loading). Four types of implants were examined. The differences of bone loss between implants(ITI standard) with enough biologic width and implants(ITI esthetic plus, Silhouette IC, Silhouette IC Laser-$Lok^{TM}$) with insufficient biologic width have been compared. Resorption angles were examined at the time of prosthetic delivery and 6-month after loading. Results and Conclusion: Within the limitation of this study, the following results were drawn. 1. The marginal bone loss of ITI standard and Silhouette IC Laser-$Lok^{TM}$ was less than that of ITI esthetic plus and Silhouette IC(P<0.05). The marginal bone loss between ITI standard and Silhouette IC Laser-$Lok^{TM}$ had no significant statistical difference(P>0.05). There was no significant statistical difference between marginal bone loss of ITI esthetic plus and Silhouette IC(P>0.05). 2. There was no significant difference in marginal bone loss between maxilla and mandible(P>0.05). 3. There was no significant difference in resorption angle among four types of implants(P>0.05). The marginal bone of implants with supracrestal collar design of less than that of biologic width had resorbed more than those with sufficient collar length. The roughness and laser microtexturing of implant neck seem to affect these results. If an implant with collar length of biologic width, exposure of fixture is a possible complication especially in the anterior regions of dentition that demand high esthetics. Short smooth neck implant are often recommended in these areas which may lack the distance between microgap and the marginal bone level. In these cases, the preservation of marginal bone must be put into consideration. From the result of this study, it may be concluded that laser microtexturing of implant neck is helpful in the preservation of marginal bone.

Microgrooves on titanium surface affect peri-implant cell adhesion and soft tissue sealing; an in vitro and in vivo study

  • Lee, Hyo-Jung;Lee, Jaden;Lee, Jung-Tae;Hong, Ji-Soo;Lim, Bum-Soon;Park, Hee-Jung;Kim, Young-Kwang;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.3
    • /
    • pp.120-126
    • /
    • 2015
  • Purpose: With the significance of stable adhesion of alveolar bone and peri-implant soft tissue on the surface of titanium for successful dental implantation procedure, the purpose of this study was to apply microgrooves on the titanium surface and investigate their effects on peri-implant cells and tissues. Methods: Three types of commercially pure titanium discs were prepared; machined-surface discs (A), sandblasted, large-grit, acid-etched (SLA)-treated discs (B), SLA and microgroove-formed discs (C). After surface topography of the discs was examined by confocal laser scanning electron microscopy, water contact angle and surface energy were measured. Human gingival fibroblasts (hGFs) and murine osteoblastic cells (MC3T3-E1) were seeded onto the titanium discs for immunofluorescence assay of adhesion proteins. Commercially pure titanium implants with microgrooves on the coronal microthreads design were inserted into the edentulous mandible of beagle dogs. After 2 weeks and 6 weeks of implant insertion, the animal subjects were euthanized to confirm peri-implant tissue healing pattern in histologic specimens. Results: Group C presented the lowest water contact angle ($62.89{\pm}5.66{\theta}$), highest surface energy ($45{\pm}1.2mN/m$), and highest surface roughness ($Ra=22.351{\pm}2.766{\mu}m$). The expression of adhesion molecules of hGFs and MC3T30E1 cells was prominent in group C. Titanium implants with microgrooves on the coronal portion showed firm adhesion to peri-implant soft tissue. Conclusions: Microgrooves on the titanium surface promoted the adhesion of gingival fibroblasts and osteoblastic cells, as well as favorable peri-implant soft tissue sealing.

Regulation of human gingival fibroblast gene expression on microgrooves: A DNA microarray study (마이크로그루브 상 인간치은섬유아세포의 유전자 발현 분석: DNA microarray 연구)

  • Lee, Kyungho;Leesungbok, Richard;Ahn, Su-Jin;Park, Su-Jung;Lee, Suk Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.361-371
    • /
    • 2017
  • Purpose: We aimed to investigate the gene expression of human gingival fibroblasts on microgroove surface using DNA microarray. Materials and methods: Microgrooves were applied on grade II titanium discs to have 0/$0{\mu}m$ (NE0, control group), 60/$10{\mu}m$ (E60/10, experimental group) of respective width/depth by photolithography. The entire surface of the microgrooved Ti substrata was further acid etched and used as the two experimental groups in this study. Human gingival fibroblasts were cultured in the experimental group and the control group, and total RNA was extracted. The oligonucleotide microarray was performed to confirm the changes of various gene expression levels between experimental group and control group. Changes of gene expression level were determined at the pathway level by mapping the expression results of DNA chips, using the KEGG (Kyoto Encyclopedia of Genes and Genomes) pathway analysis. Results: Gene expression levels on E60/10 and NE0 were analyzed, there were 123 genes showing significant differences in expression more than 1.5 times on E60/10 microgrooved surface compared to NE0 surface, and 19 genes showing significant differences in expression more than 2 times. The KEGG pathway analysis confirmed the changes in gene expression levels under experimental conditions. Cell signaling, proliferation, and activity among the various gene expression results were identified. Conclusion: Microgrooved surfaces induce gene expression changes and related cell signaling. According to the results of this study, microgrooves can be used as the surface of various biomaterials which need to improve cell activity through gene expression changes and activation of cell signaling.