• 제목/요약/키워드: microelectrode

검색결과 141건 처리시간 0.026초

Discharge Patterns and Peripheral Nerve Inputs to Cardiovascular Neurons in the Medulla of Cats: Comparison between the lateral and medial medulla

  • Kim, Sang-Jeong;Lim, Won-Il;Park, Myoung-Kyu;Lee, Jin;Kim, Jun
    • The Korean Journal of Physiology
    • /
    • 제28권2호
    • /
    • pp.133-141
    • /
    • 1994
  • The discharge patterns and peripheral nerve inputs to cardiovascular neurons were investigated in rostral ventrolateral medulla (RVLM) and raphe nucleus of cats. The data from the two were compared to determine their roles in cardiovascular regulation and the endogenous analgesic system. Animals were anesthetized with ${\alpha}-chloralose$ and single cell activities were recorded by carbon-filament microelectrode and their relationships with cardiovascular activity were analyzed. In RVLM area, a total of thirty-three cells were identified as cardiovascular neurons. During one cardiac cycle, the mean discharge rate of the neurons was $1.96{\pm}0.29$ and the peak activity was observed 45 ms after the systolic peak of arterial blood pressure. Thirteen cells could be activated antidromically by stimulation of the the $T_2$ intermediolateral nucleus. Forty-three raphe neurons were identified as cardiovascular neurons whose mean discharge rate during one cardiac cycle was $1.02{\pm}0.12$. None of these cells could be activated antidromically. Study of the interval time histogram of RVLM neurons revealed that the time to the first peak was $128{\pm}20.0\;ms$, being shorter than the period of a cardiac cycle. The same parameter found from the raphe neurons was $481{\pm}67.2\;ms$, which was much longer than the cardiac cycle length. Of seventeen RVLM neurons examined ten received only the peripheral $A{\delta}-afferent$ inputs, whereas six RVLM neurons received both $A{\delta}-$ and C-inputs; the remaining one cell received an inhibitory peripheral C-input. In contrast, nine of eleven raphe neurons were found to receive $A{\delta}-inputs$ only. We conclude that the main output of cardiovascular regulatory influences are mediated through the RVLM neurons. The cardiovascular neurons in the raphe nucleus appear to serve as interneurons transferring cardiovascular afferent information to the raphespinal neurons mediating the endogenous analgesic mechanisms.

  • PDF

자기공명영상을 이용한 금속전극의 정확한 위치 결정 (Accurate Localization of Metal Electrodes Using Magnetic Resonance Imaging)

  • 조은혜;김민호;하윤;김동현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제15권1호
    • /
    • pp.11-21
    • /
    • 2011
  • 목적: 금속전극은 MRI 안에서 자기장의 왜곡을 일으켜 영상에 인공물이 나타난다. 본 논문에서는 전극이 B0와 수직으로 놓였을때 자기장 패턴의 특성을 이용하여 oblique-view angle imaging 방식을 통해 전극의 정확한 위치를 결정하는 방법을 제시하고자 한다. 대상 및 방법: 다양한 직경과 자화율을 가진 금속 전극모델의 시뮬레이션을 통하여 전극으로 인해 왜곡되는 field map의 양상을 파악하고 해상도에 따른 turbo spin-echo (TSE) 영상의 왜곡패턴을 분석하여 일반적인 영상기 법($90^{\circ}$ view)과 $45^{\circ}$ oblique-view에서의 위치 추정 기준을 마련하였으며 3.0T 임상용 장비에서 실제 전극의 TSE영상을 획득하여 시뮬레이션과 대조 검증하였다. 상대적으로 자기장의 왜곡에 민감한 gradient-refocused echo (GRE)시퀀스에서는 위상 영상을 이용해 위치를 추정하였다. 결과: 금속전극이 B0와 수직일 때 전극을 통과하는 $45^{\circ}$ 선상에서는 자기장 패턴의 변화가 매우 적었다. TSE 시퀀스의 경우 $45^{\circ}$ oblique-view 영상에서는 자화율의 크기에 관계없이 위치 추정기준이 잘 들어 맞았으며 자기장 왜곡에 의한 픽셀이 동양상이 양방향 대칭적으로 일어나므로 해상도가 낮은 경우에도 정확한 위치 추정이 가능하였다. 또한 GRE 시퀀스를 사용하였을때 $45^{\circ}$ oblique-view에서는 위상의 극성이 변화하는 선이 직교좌표계와 일치하기 때문에 일반적 방법보다 위치추정이 용이하였다. 결론: 시뮬레이션과 실제영상을 이용하여 일반적인 $90^{\circ}$ view에서보다 $45^{\circ}$ oblique-view에서 금속전극의 위치추정이 용이함을 확인하였다. 이는 전기 생리학적인 뇌연구 및 뇌수술 등을 MRI로 모니터링 하는데 적용 가능할 것으로 기대된다.

파킨슨씨병 환자에서 편측 담창구파괴술의 효과 (Efficacy of Unilateral Pallidotomy for Parkinson's Diesease)

  • 조우진;이경진;지철;박성찬;박해관;조정기;조경근;나형균;강준기;최창락
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권8호
    • /
    • pp.976-980
    • /
    • 2001
  • Objectives : For Parkinsonian patients who had not reacted favorably on drug therapy are good candidate for ventroposterolateral pallidotomy, although not curative. We studied these patients after unilateral pallidotomy, to confirm the effectiveness and safety of this procedure. Methods : We evaluated the 17 patients with idiopathic Parkinson's diesease who had undergone unilateral posteroventral pallidotomy. All patients responded to levodopa initially. Mean age was 55 years(38-75years), and mean duration of disease was 9.8 years(3-20years). Pre-and postoperative evaluation at 3 month intervals included Unified Parkinson's Disease Rating scale(UPDRS) scoring, Hoehn and Yahr(H & Y) staging, and neuropsychological examinations. Results : Pallidotomy significantly improved parkinsonian symptom(tremor, rigidity, bradykinesia, dyskinesia, sensory symptom). Nine of 10 patients who showed dyskinesia preoperatively significant improvement. The mean dose of levodopa in 9 patients was lowered. The mean H & Y score and UPDRS score were improved in on and/or off time in 15 patients. Among patients who were not improved, one patient worsened, and the others showed no change. The mean overall UPDRS off score changed from 76 preoperatively to 44(33%) at 6 months and from 70 to 52(25%) at 1 year. Transient surgical morbidity was showen in four patients and included dysarthria, hypotonia and confusion. Conclusion : We conclude that pallidotomy is safe and effective in patients who have levodopa-reponsive parkinsonism with severe symptom fluctuation. Unilateral pallidotomy also considered helpful to ipsilateral symptom. Unilateral pallidotomy can improve all of parkinsonian's symptom and allow to reduce the levodopa medication. Most of patients show satisfactory results.

  • PDF

파킨슨환자의 자기공명영상과 미세전극기록을 이용한 담창구 파괴술 (Pallidotomy Guided by MRI and Microrecording for Parkinson's Disease)

  • 이경진;손형선;박성찬;조경근;박해관;최창락
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권1호
    • /
    • pp.41-46
    • /
    • 2001
  • Objective : The exact position of the lesion during the pallidotomy is critical to obtain the clinical improvement of parkinson's disease without damage to surrounding structure. Ventriculogrphy, CT(computed tomograpy) or MRI(magnetic resonance imaging) have been used to determine the initial coordinates of stereotactic target for pallidotomy. The goal of this study was to determine whether microelectrode recording significantly improves the neurophysiologic localization of the target obtained from MRI. Methods : Twenty patients were studied. They underwent a unilateral pallidotomy. Leksell frame was applied and T1 axial images parallel to the AC-PC(anterior commissure-posterior commissure) plane using a 1.5 Tesla MRI with 3mm slice thickness were obtained. Anteroposterior coordinate of target was chosen at 2mm in front of the midcommissural point and lateral coordinate between 19 and 22mm from the midline. The vertical coordinate was calculated on coronal slice using a fast spin echo inversion recovery sequence(FSEIR) related to the position of the choroidal fissure and ranged over 4-5mm below the AC-PC plane. Confirmation of the anatomical target was done on axial slices using the same FSEIR sequence . Microrecording was done at the pallidum contralateral to the symptomatic side using an electrode with a tip diameter of $1{{\mu}m}$ diameter tip and 1.1-1.4 mOhm impedance at 1000Hz. Electrophysiologic localization of the target was also confirmed intraoperatively by macrostimulation. Results : Microrecording techniques were reliable to define the transition from the base of the pallidum which was characterized by the disappearance of spike activity and by the change of the audible background activity. Signals from high amplitude neurons firing at 200-400Hz were recorded in the pallidal base. X, Y and Z coordinates of target obtained from the MRI were within 1mm from the X, Y, Z coordinates obtained with microrecording in 16 patients (80%), 15 patients(75%), 10 patients(50%) respectively. The difference of Y coordinate between on MRI and on microrecording was 4mm in only one patient. Conclusion : The MRI was accurate to localize the target within 1mm of the error from microrecording target in 70% of the patients. 4mm discrepancy was observed only once. We conclude that MRI alone can be used to determine the target for pallidotomy in most patients. However, microrecording technique can still be extremely valuable in patents with aberrant anatomy or unusual MRI coordinates. We also consider physiologic confirmation of the target using macrostimulation to be mandatory in all cases.

  • PDF

백서에서 삼차신경 유발전위의 특성과 경로 분석 (Characteristics of Trigeminal Evoked Potential and It's Pathway in the Rat)

  • 김세혁;조춘식;권오규;이배환;박용구;정상섭
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권8호
    • /
    • pp.985-994
    • /
    • 2000
  • Objective : There are some advantages of trigeminal evoked potential(TEP) recording compared to other somatosensory evoked potential(SSEP) recordings. The trigeminal sensory pathway has a pure sensory nerve branch, a broader receptive field in cerebral cortex, and a shorter pathway. Despite these advantages, there is little agreement as to what constitutes a normal response and what wave forms truly characterize the intraoperative TEP. This study presents the normative data of TEP recorded on the epidural surface of the rat with a platinum ball electrode. Materials & Methods : Under general anesthesia with urethane, the adult Sprague-Dawley male rats(300-350g) were given electrical stimulation with two stainless steel electrodes which were inserted into the subcutaneous layer of the area around whiskers. A reference electrode was positioned in the temporalis muscle ipsilateral to the recording site. Results : TEPs were recorded in the Par I area of somatosensory cortex and recorded most apparently on the point of 2mm posterior from the bregma and 6mm lateral from the midline. The typical wave form consisted of 5 peaks (N1-P1-N2-P2-N3 according to emerging order, upward negativity). Each latency to corresponding peaks was not influenced by the different intensities of stimulation, especially from 1 to 5mA. Average latencies of 5 peaks were in the following order ; 7.7, 11.1, 15, 22.3, 29.4ms. There was also no significant difference between latencies before and after administration of muscle relaxant(pancuronium). For the electrophysiological localization of recorded waves, the action potential of a single unit was recorded with glass microelectrode(filled with 2M NaCl, $3-5M{\Omega}$) in the thalamus of rat. A sharp wave was recorded in the VPM nucleus, in which the latency was shorter than that of N1. This suggests that all 5 peaks were generated by neural activities in the suprathalamic pathway. Conclusion : In terms of recording near-field potentials, our data also suggests that TEP in the rat may be superior to other SSEPs. In overall, these results may afford normative data for the studies of supratentorial lesions such as hydrocephalus or cerebral ischemia which can have an influence on near-field potentials.

  • PDF

기니픽 유두근에서 α1-adrenoceptor 자극에 의한 세포내 pH와 Na+ 증가는 Na+-H+ 교환기를 경유 (α1-adrenoceptor stimulation increases intracellular pH and Na+ via Na+-H+ exchange in guinea pig papillary muscle)

  • 김진상
    • 대한수의학회지
    • /
    • 제35권2호
    • /
    • pp.229-236
    • /
    • 1995
  • The effect of ${\alpha}_1$-adrenoceptor(${\alpha}_1$-AR) stimulation on intracellular pH($pH_i$), $Na^+$ activity($a_{Na}{^i}$) and contractility were investigated in isolated papillary muscles of euthyroid or hyperthyroid guinea pig with conventional microelectrode, $Na^+$ or $H^+$-selective microelectrodes, and tension transducer. Stimulation of the ${\alpha}_1$-AR by phenylephrine produced a decrease in $a_{Na}{^i}$ in euthyroid preparations. This decrease in $a_{Na}{^i}$ was abolished in presence of PKC activator, phorbol dibutyrate, and increased contrary to decrease. Phenylephrine also increased $a_{Na}{^i}$ in hyperthyroid ones. However, phenylrephtine produced an increase in $pH_i$ in both euthyroid and hyperthyroid ones. These changes were blocked by prazosin, an antagonist of ${\alpha}_1$-AR. These findings suggest that the changes in $a_{Na}{^i}$ and $pH_i$ are mediated by a stimulation of $Na^+-H^+$ exchange via ${\alpha}_1$-AR stimulation. This study focused on the increase in $a_{Na}{^i}$, $pH_i$ and contractility. The increase in $pH_i$ was blocked by amiloride or EIPA, $Na^+-H^+$ exchange inhibitors. Therefore, the increase in $a_{Na}{^i}$ and $pH_i$ mediated by ${\alpha}_1$-AR appeared to be due to an influx of $Na^+$ and a reduction of $H^+$ through $Na^+-H^+$ exchange. This study also revealed that the increase in $pH_i$ and $a_{Na}{^i}$ might be related to the sustained positive inotropic response. The $a_{Na}{^i}$ increase may contribute to the intracellular $Ca^{2+}$ through the $Na^+-Ca^{2+}$ exchange, and the $pH_i$ increase could cause an increase in the $Ca^{2+}$ sensitivity of myofilaments and may augment the ${\alpha}_1$-AR-mediated positive inotropic response.

  • PDF

청각신경신호 검출 장치용 다중채널 아나로그 프론트엔드 (Multi-Channel Analog Front-End for Auditory Nerve Signal Detection)

  • 천지민;임승현;이동명;장은수;한건희
    • 대한전자공학회논문지SD
    • /
    • 제47권1호
    • /
    • pp.60-68
    • /
    • 2010
  • 청신경의 이상으로 발생하는 감각신경성 난청의 경우, 달팽이관이나 청각신경에 전극을 이식하여 전기자극을 가함으로써 청지각을 살릴 수 있다. 이를 위해 우선적으로, 각 청각신경들이 담당하여 인지할 수 있는 소리의 주파수 분포를 표시한 음계소지도를 파악해야 한다. 본 논문에서는 청각신경신호 검출 장치용 다중채널 아나로그 프론트엔드 회로를 제안한다. 제안된 아나로그 프론트엔드의 각 채널은 AC 커플링 회로, 저 전력 4차 Gm-C LPF와 단일 기울기 ADC로 이루어진다. AC 커플링 회로는 청각신호의 불확실한 DC 전압 레벨을 제거하고 AC 신호만 전달한다. Gm-C LPF는 청각신호의 대역폭을 고려하여 설계 되었으며, 플로팅-게이트 기법이 적용된 OTA를 사용하였다. 채널별 ADC를 구현하기 위해서, 최소의 면적으로 구현할 수 있는 단일 기울기 ADC 구조를 사용하였다. 측정 결과, AC 커플링 회로와 4차 Gm-C LPF는 100 Hz - 6.95 kHz의 대역폭을 가지며, 단일 기울기 ADC는 7.7 비트의 유효 해상도를 가진다. 그리고, 채널 당 $12\;{\mu}W$의 전력이 소모 되었다. 전원 전압은 3.0 V가 공급되었고, 코어는 $2.6\;mm\;{\times}\;3.7\;mm$의 실리콘 면적을 차지한다. 제안된 아나로그 프론트엔드는 1-poly 4-metal $0.35-{\mu}m$ CMOS 공정에서 제작 되었다.

Carbogen 흡입하에서 Fluosol-DA 20%의 투여가 이식동물 종양의 산소분압에 미치는 영향 (Improving Oxygenation in the Murine Tumors by a perfluorochemical Emulsion (Fluosl-DA $20\%$)

  • 이인태;김귀언;송창원
    • Radiation Oncology Journal
    • /
    • 제8권1호
    • /
    • pp.1-6
    • /
    • 1990
  • SCK 종양세포를 이식받은 mice에 Fluosol-DA $20\%$를 정맥주사한 후 이 종양세포를 추출하여 in vitro 실험으로 측정해 본 방사선 체포생존곡선의 Do와 Dq의 값은 Fluosol-DA $20\%$를 투여하지 않은 대조군과 대동소이하여 Fluosol-DA $20\%$가 방사선 감수성 자체에 미치는 영향은 미미하다고 해석되었다. 또한 Fluosol-DA $20\%$만을 투여한 종양의 산소분압($PO_2$)에는 별 변화가 없었으나 Fluosol-DA $20\%$를 Carbogen 흡입하에 투여시킨 종양에선 대조군의 산소분압 중앙값 4 mmHg가 62mmHg로 10배이상 증가되어 reoxygenation effect를 직접 증명할 수 있었고 hypoxic cell fraction도 약 8배정도 감소됨을 규명하였다. 한편 Carbogen만을 단독으로 흡입시킨 종양의 경우에도 산소분압의 증가를 관찰할 수 있었으나 Fluosol-DA $20\%$ 병용군보다는 산소분압상승 효과가 미약함을 관찰할 수 있었다. 따라서 Fluosol-DA $20\%$에 의한 방사선 반응의 향상은 방사선 감수성의 증가보다는 reoxygenation의 결과이며 reoxygenation 효과를 개선하기 위해서는 Fluosol-DA의 단독투여보다는 Car-bogen 흡입하에서 Fluosol-OA $20\%$의 투여가 이상적이라는 결론을 얻었다.

  • PDF

수종 수산화칼슘 제재를 이용한 근관충전 후 치근상아질에서의 염기도 변화 (ALKALINITY CHANGE IN ROOT DENTIN FOLLOWING CALCIUM HYDROXIDE DRESSING)

  • 이경하;안연실;이광원;이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.670-679
    • /
    • 1997
  • The pH changes in 4 small cavities prepared at the facial inner dentin and lingual outer dentin of the cervical and apical portion of root filled with calcium hydroxide pastes were investigated. Forty extracted permanent teeth with single canal were instrumented with step-back method, and then 4 small cavities were prepared. Two inner dentin cavities were cut a distance of about 1.0mm from the canal wall and two outer dentin cavities were cut to a depth of about 0.5mm from the root surface. Root canals and prepared cavities were flushed with 17% EDTA, and then irrigated with 5% NaOCl to remove smear layer. Teeth were randomly divided into four groups. Control group was not filled and the remaining other groups were filled with mixture of calcium hydroxide and distilled water, Vitapex$^{(R)}$ paste and Pulpdent$^{(R)}$ paste respectively. The pH change of the dentin in each cavity was measured at 0, 1, 3, 7, 14, 21, 28, 60, 90 days with pH microelectrode(WPI Co., USA). The results were as follows : 1. The groups obturated with Pulpdent$^{(R)}$ paste and Aqueous calcium hydroxide produced the increased pH level at 1 day and maintained plateau over next 3weeks and decreased after 3weeks. 2. The group obturated with Vitapex$^{(R)}$ paste observed no significant pH change until 2weeks and slight increased pH at 3weeks and sequential increasing after 3weeks. But, the pH in the group obturated with Vitapex$^{(R)}$ paste remained significantly below the pH measured in the other two experimental groups(P<0.05). 3. All experimental groups showed pH level similar to control group after 28 days. 4. The pH of outer dentin is slightly higher than that of inner dentin. There is no significant difference in pH level between apical and cervical dentin throughout the duration of the experiment, though apical dentin showed slightly higher pH than cervical dentin at 1 day(P<0.05).

  • PDF

안지오텐신 II의 적출심근 및 대동맥 평활근에 대한 작용기전 (Effects of Angiotensin II on Isolated Cardiac Muscle and Aortic Strips in Rabbit)

  • 김규찬;김기환;엄융의
    • The Korean Journal of Physiology
    • /
    • 제17권1호
    • /
    • pp.45-54
    • /
    • 1983
  • Contractile responses of myocardium and vascular smooth muscle to angiotensin II were studied in isolated rabbit papillary muscles and aortic helical strips, with respect to the sensitivity and the mechanism of action. All experiments were performed in $HCO-_3\;-buffered Tyrode solution which was aerated with $3%\;CO_2-97%\;O_2$ and kept pH 7.35 at $35^{\circ}C$. Action potentials were measured by conventional microelectrode technique in the papillary muscles. Helical strips of vascular smooth muscle were prepared from the descending thoracic aorta of the rabbit. Angiotensin II elicited a positive inotropic effect in doses from $10^{-8}$ to $10^{-6}\;M$, and this effect was dose-dependent and characterized by a symmetrical increase of maximum dP/dt during contraction and relaxation phase. Slow responses (or slow action potentials) were induced by A. II $(10^{-6}\;M)$ in the papillary muscle hypopolarized by 27 mM $K^+$. These A. II-induced slow action potentials were eliminated by verapamil (2 mg/l), but not affected by propranolol $(10^{-5}\;M)$. In aortic helical strips, contractile force was increased dose-dependently in the range of $10^{-10}{\sim}10^{-7}\;M$ A. II. $ED_{50}$ in aorta was $3{\times}10^{-9}\;M$ A. II, whereas that in paillary muscle was $2.5{\times}10^{-7}\;M$ A. II. A. II contracted vascular smooth muscle in depolarizing concentration of $K^+$ (100 mM $K^+$), and also produced a sustained contraction even in the presence of verapamil and regitine. The results of this experiment suggest that the primarily important physiological role of A. II is the action on the blood vessel, and the positive inotropic effect of A. II in papillary muscle results from the increase of slow inward $Ca^{++}$ current, and that A. II-induced contraction of aorta is independent of transmembrane potential and associated with promoting bet transmembrane $Ca^{++}\;-influx$ and the mobilization of cellular $Ca^{++}$.

  • PDF