• Title/Summary/Keyword: micro-fiber

Search Result 537, Processing Time 0.027 seconds

Tensile Behavior of Highly Ductile Cementitious Composites Using Normal Sand as Fine Aggregate (일반모래를 잔골재로 사용한 고연성 시멘트 복합체의 인장거동)

  • Lee, Bang Yeon;Kang, Su-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.178-184
    • /
    • 2017
  • This study was aimed to investigate the tensile behaviors of PE(Polyethylene) fiber-reinforced highly ductile cementitious composites with different combinations of micro silica sand and normal sand(river sand) with maximum particle size of 4.75 mm. Flow test result indicated the increase of flowability with higher replacement ratio of river sand. There was no noticeable difference in the mean compressive strength with different replacement ratio of river sand, but the variation in the compressive strength increased as higher amount of river sand was adopted for the replacement. The difference in the uniaxial tensile strength was negligible, but the tensile strain capacity was significantly influenced by the replacement ratio of river sand. It is thought that increased density of multiple cracks induced improved tensile strain capacity when higher percentage of river sand was adopted for fine aggregate. The deviation in the strain capacity increased as the replacement ratio of river sand was higher, as in the compressive strength. This study presented the feasibility of using normal sand instead of micro silica sand for highly ductile cementitious composites with equivalent or better uniaxial tensile performance, even though it might increase the deviation in the performance.

Evaluation of Beach Pollution by Aquaculture Styrofoam Buoys in Tongyeong, Korea (양식장 스티로폼 부자쓰레기로 인한 통영 해변의 오염 평가)

  • Hong, Su Yeon;Lee, Chan Won;Hong, Sunwook;Lee, Jongmyoung;Jang, Yong Chang
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.2
    • /
    • pp.104-115
    • /
    • 2014
  • Abundance and composition of marine debris on 13 beaches of Tongyeong City, South Korea were surveyed in 2013 Autumn. The average quantity of macro debris (>25 mm) was about 30 particle/$m^2$ and that of micro debris (1 mm-25 mm) was about 26,971 particle/$m^2$. This is a very high level compared with other areas of South Korea and the other countries. Among the 7 material types of debris (styrofoam, hard plastic, fiber, metal, glass, wood and others), styrofoam composed a large portion: 75% of macro debris and 98% of micro debris. And among the 'whole' styrofoam debris items whose original volume is remained more than 50%, styrofoam buoy debris composed 93%. This result suggests that the beaches surveyed are seriously contaminated by marine debris, and most of its sources are aquaculture styrofoam buoys. Management of styrofoam buoy debris used for oyster aquaculture in Tongyeong City is important not only for Tongyeong city, but also for other areas, because Tongyeong city hosts the biggest number of oyster aquaculture areas in South Korea.

Inter-comparison of Two Aethalometers for Aerosol Black Carbon Measurements (대기 에어로졸 검댕입자 측정을 위한 두 aethalometer의 상호비교)

  • Jung, Jung-Hoon;Park, Seung-Shik;Yoon, Kwan-Hoon;Cho, Sung-Yong;Kim, Seung-Jai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.2
    • /
    • pp.201-208
    • /
    • 2011
  • Recently, a real-time, pocket-sized aethalometer (microAeth$^{(R)}$ model AE51) has been developed by Magee Scientific Inc. for measuring the concentration of black carbon in the atmosphere. In this study, two aethalometers, models AE-16 and AE-51, which measure the optical absorption of carbon particles at infrared 880 nm, were operated at time interval of 5-min between January 9 and February 10, 2010 at an urban site of Gwangju, to compare the accuracy of black carbon (BC) concentrations reported from the AE-51 model and to investigate reasonable sampling time of filter media in the AE-51. The air samples in the AE-51 and AE-16 models are collected on T60 (Teflon coated glass fiber) filter media (filter spot area: 0.07 $cm^2$) and quartz fiber roll-tape filter (filter spot area: 1.67 $cm^2$), respectively. Real-time measurement results indicate that when the filters were clean, the AE-51 BC was greater than or similar to the AE-16 BC data. However as the filter spots become darker, the AE-16 BC concentrations were higher than the AE-51 BC data and the difference in the BC concentrations from two AE models becomes gradually increased. Relative error in the AE-51 and AE-16 BC concentrations showed significance difference depending on used time of the filter in the AE-51 model, weather pattern, levels of air pollution, etc, ranging from 11.5% (used time of the filter in AE-51: 1,595 min) to 52.5% (used time of the filter in AE-51: 2,085 min). When considering the used time of one filter ticket in the AE-51 model and difference (or relative error %) between AE-16 and AE-51 BC concentrations, it is recommended that the standard sampling time per one filter ticket within the AE-51 model be less than approximately 24 hr (1,440 min) under the normal weather conditions except for severe haze and mist events.

Comparison of dietary food and nutrient intakes by supplement use in pregnant and lactating women in Seoul

  • Kim, Hyesook;Jang, Won;Kim, Ki-Nam;Hwang, Ji-Yun;Chung, Hae-Kyung;Yang, Eun-Ju;Kim, Hye-Young;Lee, Jin-Hee;Moon, Gui-Im;Lee, Jin-Ha;Kang, Tae-Seok;Chang, Namsoo
    • Nutrition Research and Practice
    • /
    • v.7 no.3
    • /
    • pp.199-206
    • /
    • 2013
  • This study was performed to compare the dietary food and nutrient intakes according to supplement use in pregnant and lactating women in Seoul. The subjects were composed of 201 pregnant and 104 lactating women, and their dietary food intake was assessed using the 24-h recall method. General information on demographic and socioeconomic factors, as well as health-related behaviors, including the use of dietary supplements, were collected. About 88% and 60% of the pregnant and lactating women took dietary supplements, respectively. The proportion of dietary supplements used was higher in pregnant women with a higher level of education. After adjusting for potential confounders, among the pregnant women, supplement users were found to consume 45% more vegetables, and those among the lactating women were found to consume 96% more beans and 58% more vegetables. The intakes of dietary fiber and ${\beta}$-carotene among supplement users were higher than those of non-users, by 23% and 39%, respectively. Among pregnant women, the proportion of women with an intake of vitamin C (from diet alone) below the estimated average requirements (EAR) was lower among supplement users [users (44%) vs. non-users (68%)], and the proportion of lactating women with intakes of iron (from diet alone) below the EAR was lower among supplement users [usesr (17%) vs. non-users (38%)]. These results suggest that among pregnant and lactating women, those who do not use dietary supplements tend to have a lower intake of healthy foods, such as beans and vegetables, as well as a lower intake of dietary fiber and ${\beta}$-carotene, which are abundant in these foods, and non-users are more likely than users to have inadequate intake of micro-nutrient such as vitamin C and iron.

A Study on Fouling Characteristics and Applicability of Fouling Reducer in Submerged MBR Process (침지형 MBR공정에서 파울링 특성과 파울링 완화제의 적용성에 관한 연구)

  • Park, Jun Won;Park, Hong June;Kim, Min Ho;Oh, Yong Keol;Park, Chul Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.371-380
    • /
    • 2013
  • Though MBR process has many advantages, the greatest risk factors in operating MBR process are occurrence of membrane fouling and decrease of flux. It is very difficult to find exact mechanism due to complex influence by many effects, although there have been recently many studies of membrane fouling. The purposes of this study are firstly evaluating bioreactor of lab-scale and micro-filtration hollow fiber membrane, secondly investigating correlation between foulants affecting membrane performance and membrane fouling, and lastly evaluating various parameters affecting fouling and applicability of membrane fouling reducer. This study found that TMP was increasing rapidly and showed 0.32 bar and the average of flux was 88 LMH. EPS concentration tends not to change much above MLSS concentration (6,000 mg/L). However, EPS concentration variation is wide below MLSS concentration (6,000 mg/L). Also, from results of membrane surface condition and element analysis using SEM/EDX, carbon and fluorine were founded to be the highest percentage in membrane because of characteristics of membrane material. In operating continuously, inorganic fouling was generated by increase of these inorganic substances such as $Al^{3+}$ and $Mg^{2+}$. Lastly, the best filtration performance was obtained for 0.03 mg MFR/mg MLSS by results of particle size, zeta potential, $SCOD_{cr}$, EPS and MLSS concentration.

Different Sources and Levels of Copper Supplementation on Performance and Nutrient Utilization of Castrated Black Bengal (Capra hircus) Kids Diet

  • Mondal, M.K.;Biswas, P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.7
    • /
    • pp.1067-1075
    • /
    • 2007
  • Twenty eight 3-4 month old castrated Black Bengal kids (Capra hircus) were used to determine the effects of source and level of dietary copper (Cu) concentration on their performance and nutrient utilization. Cu was supplemented (0, 10, 20 and 30 mg/kg diet DM) as copper sulfate ($CuSO_4$, $5H_2O$) or copper proteinate (Cu-P). Kids were fed a basal diet containing maize (19.5%), soybean (17.0%), deoiled rice bran (56.5%), molasses (4.0%), di-calcium phosphate and salt (1.0% each) and mineral and vitamin mixture (0.5% each) supplements at 3.5% of body weight to meet NRC (1981) requirements for protein, energy, macro minerals and micro minerals, excluding Cu. The basal diet contained 5.7 mg Cu/kg, 122.5 mg Fe/kg, 110 mg Zn/kg, 0.26 mg Mo/kg and 0.32% S. $CuSO_4$ or Cu-P was added to the basal diet at the rate of 10, 20 and 30 mg/kg. Kids were housed in a well ventilated shed with facilities for individual feeding in aluminum plated metabolic cages. Blood samples were collected from the jugular vein on d 0, 30, 60 and 90 to determine hemoglobin (Hb), packed cell volume (PCV), total erythrocyte count (TEC), total leukocyte count (TLC) and serum enzymes (alkaline phosphatase, alanine transferase and aspertate transferase). A metabolism trial of 6 days duration was conducted after 90 days of experimental feeding. Statistical analysis revealed that source and level of Cu supplementation improved live weight gain (p<0.04) and average daily gain (p<0.01). No significant contribution of source and level of Cu to alter serum serum enzymes was evident. Goats fed Cu-P tended to have higher Hb, PCV and TEC than with $CuSO_4$ supplementation. Cu-P increased digestibility of ether extract (EE, p<0.02) and crude fiber (p<0.05) and showed an increasing trend (p<0.09) for digested crude protein (CP) and crude fiber (CF). Supplemental dose of Cu linearly improved (p<0.02) digestibilities of dry matter (DM), organic matter (OM), EE and nitrogen free extract (NFE). Though the absorption of nitrogen (N) was not affected (p>0.10) by both source and dose of Cu, N retention was affected (p<0.04) and there was a significant $Source{\times}Dose$ interaction (p<0.05). Final body weight (BW) was not influenced (p>0.10) by the source of Cu but increasing dose of Cu increased (p<0.04) the BW of kids. TDN intake (g/kg $W^{0.75}$) was higher (p<0.05) with the increased dose of Cu and there was a significant $Source{\times}Dose$ interaction. It was concluded that supplementation of Cu from different sources and varying dose level in a concentrate based diet may improve performance, nutrient utilization and plane of nutrition in castrated Black Bengal kids. The effects on performance and nutrient utilization are more pronounced with Cu-P than $CuSO_4$ supplementation. Higher dose of Cu showed better result than lower dose.

STRESS DISTRIBUTION OF ENDODONTICALLY TREATED MAXILLARY SECOND PREMOLARS RESTORED WITH DIFFERENT METHODS: THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS (상이한 방법으로 수복한 근관치료된 상악 제2소구치의 응력분포: 3차원 유한요소법적 분석)

  • Lim, Dong-Yeol;Kim, Hyeon-Cheol;Hur, Bock;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.69-79
    • /
    • 2009
  • The purpose of this study was to evaluate the influence of elastic modulus of restorative materials and the number of interfaces of post and core systems on the stress distribution of three differently restored endodontically treated maxillary second premolars using 3D FE analysis. Model 1, 2 was restored with a stainless steel or glass fiber post and direct composite resin. A PFG or a sintered alumina crown was considered. Model 3 was restored by EndoCrown. An oblique 500 N was applied on the buccal (Load A) and palatal (Load B) cusp. The von Mises stresses in the coronal and root structure of each model were analyzed using ANSYS. The elastic modulus of the definitive restorations rather than the type of post and core system was the primary factor that influenced the stress distribution of endodontically treated maxillary premolars. The stress concentration at the coronal structure could be lowered through the use of definitive restoration of high elastic modulus. The stress concentration at the root structure could be lowered through the use of definitive restoration of low elastic modulus.

An Optical True Time-Delay for Two-Dimensional X-Band Phased Array Antennas (2차원 X-밴드 위상 배열 안테나용 광 실시간 지연선로)

  • Jung, Byung-Min;Kim, Sung-Chul;Shin, Jong-Dug;Kim, Boo-Gyoun
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.287-294
    • /
    • 2005
  • In this paper, an optical true time-delay (TTD) for two-dimensional (2-D) phased array antennas (PAAs), composed of a multi-wavelength optical source and a fiber optic delay line matrix consisting of $2\times2$ optical switches with optical fiber connected between cross ports, has been proposed. A 2-bit $\times4-bit$ optical TTD for 10-GHz 2-D PAAs has been implemented by cascading a wavelength dependent TTD (WD-TTD) and a wavelength independent TTD (WI-TTD). The unit time delay for WD-TTD and WI-TTD have been chosen as ${\Delta}T=12ps$ and $\Delta\tau=6ps$, respectively. Time delay have been measured at all radiation angles. The maximum delay error for WD-TTD was measured to be 3 ps due to jitter incurred from gain switching. For the case of WI-TTD, error was within ${\pm}\;1\;ps$. The proposed optical TTD for a 2-D PAA has the following advantages: 1) higher gain compared to one-dimensional linear PAAs, 2) stabilization of optical power and wavelength by using a multi-wavelength optical source, and 3) fast beam scan and simple operation due to electronic control of the $2\times2$ optical switches matrix on a column-by-column basis.

Comparison on Accuracy of Static and Dynamic Contact Angle Methods for Evaluating Interfacial Properties of Composites (복합재료의 계면특성 평가를 위한 접촉각 방법의 정확도 비교)

  • Kwon, Dong-Jun;Kim, Jong-Hyun;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.23 no.3
    • /
    • pp.87-93
    • /
    • 2022
  • To analyze the interfacial property between the fiber and the matrix, work of adhesion was used generally that was calculated by surface energies. In this paper, it was determined what types of contact angle measurement methods were more accurate between static and dynamic contact angle measurements. 4 types of glass fiber and epoxy resin were used each other to measure the contact angle. The contact angle was measured using two types, static and dynamic contact angle methods, and work of adhesion, Wa was calculated to compare interfacial properties. The interfacial property was evaluated using microdroplet pull-out test. Generally, the interfacial property was proportional to work of adhesion. In the case of static contact angle, however, work of adhesion was not consistent with interfacial property. It is because that dynamic contact angle measurement comparing to static contact angle could delete the error due to microdroplet size to minimize the surface area as well as the meniscus measuring error.

Injection Characteristics Evaluation of Conductive Grout Material According to Carbon Fiber Mixing Ratio (탄소섬유 배합비에 따른 전도성 그라우트 재료의 주입특성평가)

  • Hyojun Choi;Wanjei Cho;Hyungseok Heo;Teawan Bang;Chanyoung Yune
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.1
    • /
    • pp.15-23
    • /
    • 2023
  • The grouting method is a method of construction for the purpose of waterproofing and reinforcing soft ground. When grout is injected into the ground, there are various types of penetration and diffusion of grout depending on the shape of the ground, the size of soil, the porosity, and the presence or absence of groundwater. the current situation. Therefore, in this study, to investigate the penetration performance of the grouting to conductive material, laboratory tests were performed on the addition of the conductive material. In the injection test, 0%, 3%, and 5% of the mixed water were added as conductive materials to the grout, and the original ground condition was composed of various types of ground composed of gravel and silica sand. Conductive grout is injected by pressure into the model ground using a dedicated injection device, and the injection time (t), pressure (p), flow rate (v) and injection amount (q) are measured, and the hardened body injected in the model ground is collected. Penetration performance was evaluated. In the results of the grout injection experiment, the amount of conductive material used and the grout injection rate showed an inverse relationship, and it was confirmed that the penetration pattern was changed according to the size of the soil particles in the model ground. The grout containing the conductive material has relatively good penetration into the ground and excellent strength and durability of the hardened body, so it was judged that it could be used as an additive for measuring the penetration range of the grout.