• 제목/요약/키워드: micro-cone

검색결과 71건 처리시간 0.02초

벼 잎 표면에서 액적의 이방성 흐름 특성에 관한 연구 (A Study on the Anisotropic Flow Characteristics of Droplets on Rice Leaf Surface)

  • 김태완
    • Tribology and Lubricants
    • /
    • 제33권6호
    • /
    • pp.251-255
    • /
    • 2017
  • In this study, we aimed to clarify the wettability and anisotropic flow characteristics of rice leaves as a basic study for engineering applications of anisotropic flow characteristics of rice leaf surface. To investigate the surface structure of rice leaf, the micro grooves and asperities of rice leaves were analyzed and quantified by scanning electron microscope, Confocal laser scanning microscopy, and stylus profilometer. The analysis of the structure of rice leaf surface confirmed that asymmetrical cone - like protrusions in leaf veins were inclined toward the leaf tip. The static contact angle test showed that the contact angle at the midline vein or leaf vein location where the micropapilla is concentrated is about $20^{\circ}$ higher than the leaf blade position. The contact angles of fresh and dried rice leave were also compared. The dried rice leaves showed a contact angle of about $5^{\circ}$ to $15^{\circ}$ higher than that of fresh leaves, suggesting that the volume of the protrusions decreased as the water was removed, thus reducing the contact area with the droplet. In the contact angle history test the hysteresis in the leaf tip direction was found to be much lower than that in the leaf petiole direction. This results can be explained that asymmetrical cone - like protrusions had a significant effect on the droplet flow characteristics through contact angle hysteresis experiment.

스크린 인쇄 공정 변수에 따른 진공유리용 필러의 단면형상 기울기 분석 (Analysis of Cross-Section Shape Slope of Pillar for Vacuum Glazing according to the Screen Printing Parameters)

  • 김재경;전의식
    • 반도체디스플레이기술학회지
    • /
    • 제11권4호
    • /
    • pp.43-48
    • /
    • 2012
  • The screen printing method is much used in the flat panel display field including the LCD, PDP, FED, organic EL, and etc. for forming the high precision micro-pattern. Also A number of studies of screen printing method has been conducted as the method for the cost down through the improvement of productivity. Because of being the dot printing method of the cylindrical shape not being the line printing method like the existing PDP barrier rib and phosphor, the pillar arrays using the screen printing method is deposited in the hemispherical type not being cylindrical shape in the existing printing process conditions. In this paper, the parameters were set on the screen printing device in order to deposit the cross-sectional shape with the cone or trapezoid shape of the pillar in depositing the pillars used the screen printing device for vacuum glazing. The cross-sectional shape slope of the pillar according to the parameters was measured. And analysis the effect of the screen printing process conditions on the cross-sectional shape slope of pillars based upon the result of being measured. The processing conditions were drawn to minimize the cross-sectional shape slope of pillar.

Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis

  • Magat, Guldane;Oncu, Elif;Ozcan, Sevgi;Orhan, Kaan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권1호
    • /
    • pp.41-49
    • /
    • 2022
  • Objectives: We compared changes in fractal dimension (FD) and grayscale value (GSV) of peri-implant alveolar bone on digital panoramic radiography (DPR) and cone-beam computed tomography (CBCT) immediately after implant surgery and 12 months postoperative. Materials and Methods: In this retrospective study, 16 patients who received posterior mandibular area dental implants with CBCT scans taken about 2 weeks after implantation and one year after implantation were analyzed. A region of interest was selected for each patient. FDs and GSVs were evaluated immediately after implant surgery and at 12-month follow-up to examine the functional loading of the implants. Results: There were no significant differences between DPR and CBCT measurements of FD values (P>0.05). No significant differences were observed between FD values and GSVs calculated after implant surgery and at the 12-month follow-up (P>0.05). GSVs were not correlated with FD values (P>0.05). Conclusion: The DPR and reconstructed panoramic CBCT images exhibit similar image quality for the assessment of FD. There were no changes in FD values or GSVs of the peri-implant trabecular bone structure at the 12-month postoperative evaluation of the functional loading of the implant in comparison to values immediately after implantation. GSVs representing bone mass do not align with FD values that predict bone microstructural parameters. Therefore, GSVs and FDs should be considered different parameters for assessing bone quality.

The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography

  • Kang, Se-Ryong;Bok, Sung-Chul;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • 제46권2호
    • /
    • pp.116-127
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. Methods: We measured the impact response of a dental implant placed into swine bone specimens composed of only trabecular bone without the cortical bone layer using an inductive sensor. The peak frequency of the impact response spectrum was determined as an implant stability criterion (SPF). The 3D microstructural parameters were calculated from CT images of the bone specimens obtained using both micro-CT and CBCT. Results: SPF had significant positive correlations with trabecular bone structural parameters (BV/TV, BV, BS, BSD, Tb.Th, Tb.N, FD, and BS/BV) (P<0.01) while SPF demonstrated significant negative correlations with other microstructural parameters (Tb.Sp, Tb.Pf, and SMI) using micro-CT and CBCT (P<0.01). Conclusions: There was an increase in implant stability prediction by combining BV/TV and SMI in the stepwise forward regression analysis. Bone with high volume density and low surface density shows high implant stability. Well-connected thick bone with small marrow spaces also shows high implant stability. The combination of bone density and architectural parameters measured using CBCT can predict the implant stability more accurately than the density alone in clinical diagnoses.

고점도 전도성 잉크 패터닝 기술을 이용한 고성능 미세전극 패턴 구현 (Implementation of High Performance Micro Electrode Pattern Using High Viscosity Conductive Ink Patterning Technique)

  • 고정범;김형찬;당현우;양영진;최경현;도양회
    • 한국정밀공학회지
    • /
    • 제31권1호
    • /
    • pp.83-90
    • /
    • 2014
  • EHD (electro-hydro-dynamics) patterning was performed under atmospheric pressure at room temperature in a single step. The drop diameter smaller than nozzle diameter and applied high viscosity conductive ink in EHD patterning method provide a clear advantage over the piezo and thermal inkjet printing techniques. The micro electrode pattern was printed by continuous EHD patterning method using 3-type control parameters (input voltage, patterning speed, nozzle pressure). High viscosity (1000cps) conductive ink with 75wt% of silver nanoparticles was used. EHD cone type nozzle having an internal diameter of $50{\mu}m$ was used for experimentation. EHD jetting mode by input voltage and applied 1st order linear regression in stable jet mode was analyzed. The stable jet was achieved at the amplitude of 1.4~1.8 kV. $10{\mu}m$ micro electrode pattern was created at optimized parameters (input voltage 1.6kV, patterning speed 25mm/sec and nozzle pressure -2.3kPa).

Micro-computed tomographic evaluation of a new system for root canal filling using calcium silicate-based root canal sealers

  • Tanomaru-Filho, Mario;Torres, Fernanda Ferrari Esteves;Pinto, Jader Camilo;Santos-Junior, Airton Oliveira;Tavares, Karina Ines Medina Carita;Guerreiro-Tanomaru, Juliane Maria
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.34.1-34.7
    • /
    • 2020
  • Objectives: This study evaluated by using micro-computed tomography (micro-CT) the filling ability and sealer apical extrusion promoted by a new Sealer Injection System (SIS; Angelus) with side openings needle, in comparison with the conventional injection system, associated with a new ready-to-use calcium silicate-based sealer (Bio-C Sealer). Materials and Methods: Acrylic resin models containing a main curved artificial canal and 3 simulated lateral canals in apical, middle and cervical thirds were used. The main root canals were prepared using a rotary system up to size 35.05. The canals were filled with Bio-C sealer by using a single cone technique and the conventional delivery system or SIS. Samples were scanned in micro-CT. The percentage of voids throughout the entire extension of the main root canal and in each third of the lateral canals, besides the apical extrusion of the sealer was calculated. Data were submitted to t-test (p < 0.05). Results: There was no difference between both systems in the main root canals filling. Although the volume percentage of voids was similar in the apical and middle thirds of lateral canals, SIS had the greatest filling ability of the cervical third lateral canal. Moreover, the conventional system showed the highest apical extrusion of the sealer. Conclusions: The conventional and SIS obturation systems had an appropriate filling ability of the main root canal. SIS had the best filling of the cervical third of the lateral canals, besides lower sealer apical extrusion, suggesting its clinical indication.

Endodontic micro-resurgery and guided tissue regeneration of a periapical cyst associated to recurrent root perforation: a case report

  • Fernando Cordova-Malca;Hernan Coaguila-Llerena;Lucia Garre-Arnillas;Jorge Rayo-Iparraguirre;Gisele Faria
    • Restorative Dentistry and Endodontics
    • /
    • 제47권4호
    • /
    • pp.35.1-35.9
    • /
    • 2022
  • Although the success rates of microsurgery and micro-resurgery are very high, the influence of a recurrent perforation combined with radicular cyst remains unclear. A 21-year-old white female patient had a history of root perforation in a previously treated right maxillary lateral incisor. Analysis using cone-beam computed tomography (CBCT) revealed an extensive and well-defined periapical radiolucency, involving the buccal and palatal bone plate. The perforation was sealed with bioceramic material (Biodentine) in the pre-surgical phase. In the surgical phase, guided tissue regeneration (GTR) was performed by combining xenograft (lyophilized bovine bone) and autologous platelet-rich fibrin applied to the bone defect. The root-end preparation was done using an ultrasonic tip. The retrograde filling was performed using a bioceramic material (Biodentine). Histopathological analysis confirmed a radicular cyst. The patient returned to her referring practitioner to continue the restorative procedures. CBCT analysis after 1-year recall revealed another perforation in the same place as the first intervention, ultimately treated by micro-resurgery using the same protocol with GTR, and a bioceramic material (MTA Angelus). The 2-year recall showed healing and bone neoformation. In conclusion, endodontic micro-resurgery with GTR showed long-term favorable results when a radicular cyst and a recurrent perforation compromised the success.

Midfacial soft tissue changes after maxillary expansion using micro-implant-supported maxillary skeletal expanders in young adults: A retrospective study

  • Nguyen, Hieu;Shin, Jeong Won;Giap, Hai-Van;Kim, Ki Beom;Chae, Hwa Sung;Kim, Young Ho;Choi, Hae Won
    • 대한치과교정학회지
    • /
    • 제51권3호
    • /
    • pp.145-156
    • /
    • 2021
  • Objective: The aim of this retrospective study was to assess the midfacial soft tissue changes following maxillary expansion using micro-implant-supported maxillary skeletal expanders (MSEs) in young adults by cone-beam computerized tomography (CBCT) and to evaluate the correlations between hard and soft tissue changes after MSE usage. Methods: Twenty patients (mean age, 22.4 years; range, 17.6-27.1) with maxillary transverse deficiency treated with MSEs were selected. Mean expansion amount was 6.5 mm. CBCT images taken before and after expansion were superimposed to measure the changes in soft and hard tissue landmarks. Statistical analyses were performed using paired t-test and Pearson's correlation analysis on the basis of the normality of data. Results: Average lateral movement of the cheek points was 1.35 mm (right) and 1.08 mm (left), and that of the alar curvature points was 1.03 mm (right) and 1.02 mm (left). Average forward displacement of the cheek points was 0.59 mm (right) and 0.44 mm (left), and that of the alar curvature points was 0.61 mm (right) and 0.77 mm (left) (p < 0.05). Anterior nasal spine (ANS), posterior nasal spine (PNS), and alveolar bone width showed significant increments (p < 0.05). Changes in the cheek and alar curvature points on both sides significantly correlated with hard tissue changes (p < 0.05). Conclusions: Maxillary expansion using MSEs resulted in significant lateral and forward movements of the soft tissues of cheek and alar curvature points on both sides in young adults and correlated with the maxillary suture opening at the ANS and PNS.

Effect of micro-osteoperforations on external apical root resorption: A randomized controlled trial

  • Shahrin, Azaitun Akma;Ghani, Sarah Haniza Abdul;Norman, Noraina Hafizan
    • 대한치과교정학회지
    • /
    • 제51권2호
    • /
    • pp.86-94
    • /
    • 2021
  • Objective: This study aimed to investigate the effect of micro-osteoperforations (MOPs) on external apical root resorption (EARR) during the initial orthodontic alignment phase of maxillary anterior crowding. Methods: Thirty patients (25 females, 5 males; mean age, 22.66 ± 3.27 years) who presented with moderate crowding of the upper labial segment and underwent extraction-based fixed appliance treatment were recruited. They were randomly allocated to receive adjunctive therapy with MOPs (n = 15) or treatment with fixed appliances only (control group; n = 15). EARR was measured from long-cone periapical radiographs taken at the start and the sixth month of treatment. A correction factor for the enlargement difference was used to calculate EARR. Data were analyzed with descriptive statistics and repeated-measures analysis of variance. Results: The mean root lengths of 168 teeth were measured and showed no statistically significant difference (p > 0.05) after six months of fixed appliance treatment in the MOP (mean difference [MD] = 0.13 mm; 95% confidence interval [CI] = -0.10-0.35) and control group (MD = 0.14 mm; 95% CI = -0.10-0.37). Most of the roots in the MOP and control groups (42.86% and 52.38%, respectively) showed only mild resorption. Less than 8% of the roots in both groups (7.14% in the MOP group and 4.76% in the control group) showed moderate resorption. Conclusions: Acceleration of orthodontic tooth movement with adjunctive MOPs therapy during the alignment phase does not exacerbate EARR in patients with moderate crowding of the upper labial segment in comparison with controls.

A simulation study on vertical focusing in micro-tip FED

  • Lee, Chun-Gyioo;Jo, Sung-Ho;Ko, Tae-Young;Moon, Soo-Young;Yunsoo Choe
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제3권1호
    • /
    • pp.30-32
    • /
    • 1999
  • Electron beam trajectory simulation results on the high voltage FED with cone-type field emitters predict that the cross-talk phenomena would be seen due to the divergence of the electron beam. In this study, computer simulations with design of experiment technique and the SNU-FEAT program were carried out for five input parameters of the aperture focusing structure. The results tell that the focusing voltage is a dominant factor. And, the beam divergence index could be reduced to 10.7$\mu\textrm{m}$ with the aperture focusing structure, however, the operating voltage of the field emitter is predicted to increase by 40% maximum.

  • PDF