• 제목/요약/키워드: micro focus x-ray source

검색결과 5건 처리시간 0.017초

소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발 (Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging)

  • 박정진;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

미소초점엑스선원 개발을 위한 전산모사 (Computer Simulation for Development of Micro-Focus X-ray Generator)

  • 김성수;이연승;김도윤;고동섭
    • 한국진공학회지
    • /
    • 제20권6호
    • /
    • pp.403-408
    • /
    • 2011
  • MFX tube를 개발하기 위하여, MFX tube 내에서 전계방출음극으로부터 방출된 전자의 궤적을 SIMION 프로그램을 이용하여 전산모사하였다. 전자의 출발위치와 상관없이 emitter에서 방출된 전자빔을 한곳에 집중시킬 수 있는 optimum extractor voltage Ve가 존재한다는 것을 알아내었다. Extractor voltage Ve는 source voltage Vs에 따라 변하지만, 두 전압의 비율(Ve/Vs)는 항상 일정하고, 그 값은 99.4%였다. Source와 extractor에 인가된 전압의 비율(Ve/Vs)이 99.4%일 때, 교차점에서의 빔 직경은 $1.2{\mu}m$였다. MFXG의 초점 크기는 교차점에서의 beam diameter보다 작을 수 없기 때문에, 교차점에서의 beam diameter을 작게 할 수 있는 조건을 찾는 것은 중요하다. 따라서 위의 두 결과는 MFX tube의 개발에 있어서 매우 중요한 결과로 판단된다.

Zoom-in X-ray Micro Tomography System

  • Chun, In-Kon;Lee, Sang-Chul;Park, Jeong-Jin;Cho, Min-Hyoung;Lee, Soo-Yeol
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.295-300
    • /
    • 2005
  • We introduce an x-ray micro tomography system capable of high resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest, we have obtained zoomed-in images of the region of interest without any contrast a nomalies. We have integrated a micro tomography system using a micro-focus x-ray source, a $1248\times1248$ flat-panel x-ray detector, and a precision scan mechanism. Using the cross-sectional images taken with the zoom-in micro tomography system, we measured trabecular thicknesses of femur bones in postmortem rats. To compensate the limited spatial resolution in the zoom-in micro tomography images, we used the fuzzy distance transform for the calculation of the trabecular thickness. To validate the trabecular thickness measurement with the zoom-in micro tomography images, we compared the measurement results with the ones obtained from the conventional micro tomography images of the extracted bone samples.

소 동물 촬영을 위한 Micro-CT의 개발 (Development of a Micro-CT System for Small Animal Imaging)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권2호
    • /
    • pp.97-102
    • /
    • 2004
  • 소 동물 촬영에 이용될 수 있는 고해상도의 x-선 cone-beam micro computed tomography (micro-CT) 시스템을 개발하였다 Micro-CT 시스템은 120${\times}$120 mm2 의 2차원 평판 x-선 감지기, micro-focus x-선 발생장치, 주사 기구부, 병렬처리 영상 재구성 시스템으로 이루어져 있다. 개발된 시스템의 성능을 평가하기 위해 대조도와 공간해상도를 측정하였다. 대조도 실험에서는 95 mGy 에서 36 CT-번호를 구별할 수 있음을 확인하였고, 공간 해상도 실험에서는 14 lp/mm 의 성능을 확인하였다. 소 동물 촬영 결과로 실험용 쥐의 대퇴부, 심장 그리고 복부 동맥 혈관을 촬영한 경상을 제시하였다. 개발된 micro-CT 시스템은 소 동물을 이용한 생명공학 분야 연구에 널리 이용될 수 있을 것으로 기대된다.

미소부 X-선 회절분석기를 이용한 미립조암광물의 상동정 및 배향도 측정 -$Al_{2}SiO_{5}$ 3상다형- (Phase identification and degree of orientation measurements far fine-grained rock forming minerals using micro-area X-ray diffractometer -$Al_{2}SiO_{5}$ Polymorphs-)

  • 박찬수;김형식
    • 암석학회지
    • /
    • 제9권4호
    • /
    • pp.205-210
    • /
    • 2000
  • 암석중에 미립(직경 0.3mm내외)으로 존재하는 조암광물의 동정 및 결정학적인 배향도를 미소부 X선 회절분석기를 이용하여 측정하였다. 실험에 사용된 표품들은 $A1_{2}SiO_{5}$ 3상디형(규선석, 남정석, 홍주석)으로서 모든 표품들은 박편상의 것을 측정대상으로 하였다 측정에 이용된 X선 회절분석기는 3(${\omega}\;{\chi}\;{\phi}$)축 회전 측각기 및 위치민감형 검출기로 구성되어 있으며 X선원으로는 $CuK_{\alpha}$를 사용하였으며 직경 $50\;\mu\textrm{m}$의 시준기를 사용하였다. 광물 동정은 3(${\omega}\;{\chi}\;{\phi}$)축 회전 측정법에 의해 시행되었으며, 박편표면에 우세하게 나타나는 광물상의 격자면을 알아보기 위해 2(${\omega}\;{\phi}$)축 회전 측정을 실시하였고 2축 회전 측정법에 의해 우세하게 나타난 회절선에 대한 격자방향의 배향도와 극분포를 확인하기 위하여 X-선 극점도 측정을 시행하였다. 3축 회전 측정결과 측정대상 광물상에 대해 동정이 가능하였으며 2축 회전 측정과 X-선 극점도 측정결과 규선석(310), 남성석(200), 홍주석(122)극이 절단면, 즉 박편표면의 법선방향으로 잘 발달하고 있음을 확인할 수 있었다. 본 측정법은 편광현미경을 사용하여 식별이 용이하지 않은 미립조암광물의 동정과 배향도를 알아보는데 유용하게 사용될 수 있는 분석기법이다.

  • PDF