Design of radiation detection circuit for gamma column scanning (자동 감마 증류탑 검사 장치를 위한 방사선 계측장치 설계)

  • Kim, Jong-Beom;Jeong, Seong-Hui
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.612-615
    • /
    • 2003
  • In this paper, a design of radiation detector for gamma column scanner is introduced. Distillation column is important unit in Petro-chemical industries, and its on-line diagnose is very important. To get density profile measured by the radiation transmitted through column is well method for on-line diagnose as gamma scanning. For this purpose radiation detection circuit, radiation source and mechanical system for moving source and detector are required. Conventional radiation detection circuit for this application is sensitive to electric noise because of interface between the radiation circuit and the controller for mechanical system. The radiation detection system introduced here is using loop coil instead of slip ring to remove contact noise. Radiation detection system designed here for gamma scanning consist of BGO detector, high voltage circuit, PHA circuit and FSK modem. The BGO detector is used as radiation sensor, high voltage circuit and peak height analysis circuit is essential to process the signal generated from BGO detector. Micro controller convert measured data into ASCII data. FSK modem transmit ASCII data. Transmitted ASCH data is picked up in antenna coil and processed for combined function with mechanical system. This method gives good result by isolating the controlling circuit of mechanical system from radiation detecting circuit which is sensitive to noise.

  • PDF

Determination of rebamipide in human plasma by column-switching high- performance liqiud chromatography.

  • Koung, Joung-Sun;Park, Chang-Hun;Kim, Ho-Hyun;Lee, Hee-Joo;Beom, Han-Sang
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.278.2-278.2
    • /
    • 2003
  • A column-switching semi-micro HPLC method with fluorescence detection was developed for the direct analysis of rebamipide in human plasma. Plasma was filtered through a 0.45 $\mu\textrm{m}$ membrane filter and 5 ${\mu}\ell$ of the filtrate was directly injected onto the pre-column. After elution of the plasma proteins to waste, the retained rebamipide and internal standard(ofloxacin) were transferred to a C18 semi-microcolumn (5$\mu\textrm{m}$, 150 ${\times}$2.0mm) where they were separated using acetonitrile-1.4% acetic acid (40:60, v/v) as mobile phase. (omitted)

  • PDF

Micro-Determination of D-Amino Acids in Milk by using Column Switching System (Column-Switching System을 이용한 우유속의 D-아미노산의 미량정량)

  • Lee, Sun Haing;Kim, Kyoung Hee;Lee, Young Cheol;Kim, Sang Tae
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.4
    • /
    • pp.257-265
    • /
    • 1995
  • Free amino acids were isolated from milk and their absolute amounts were determined by reversed phase high performance liquid chromatography after derivatization with dansyl chloride. The determination of D- and L-amino acids was based on achiral separation on a C18 column. It was found that milk contained totally 41.00 mg DL-amino acids in 100 mL milk. The level of D-amino acids to L-amino acids was determined by a column-switching system combining an achiral reversed phase separation and chiral chelate additive. The chiral separation was carried out with addition of the chiral Cu(N-benzyl-L-proline)2 chelate to the mobile phase in reversed phase liquid chromatography. It was found that the determination of 16 different amino acids is feasible in the milk sample with a C18 column separation and 12 D-amino acids out of the 16 amino acids can be determined via the column-switching system with chiral separation. 2.05% of D-glutamic acid and 2.93% of D-alanine were found in milk.

  • PDF

Determination of Protein Amino Acids as the N-TFA N-Butyl Esters by Gas Liquid Chromatography (Gas Liquid Chromatography에 의한 단백질 아미노산의 분석)

  • Woo, Kang-Lyung
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.88-93
    • /
    • 1990
  • For effective separation of the N-TFA n-butyl ester amino acids on the stainless steel column by GLC, dual column of the mixed stationary phases, 3.36% OV-17+3.0% SE-30(column 1) and 1% NPGS +0.5% OV-17+0.5% SE-30(column 2) on chromosorb W HP 100-120 mesh, were used. On the column 1. the nineteen amino acids except histidine were obtained. However, alanine and valine peaks were not separated by this column. On the column 2, the sixteen amino acid peaks showed good separation, but tryptophan. arginine, histidine, and tyrosine peaks were not obtained. Calibration graphs for all amino acids obtained by the plotting the ratios of their peaks hights to that of internal standard versus the micro mole of the amino acids in the range $1.25{\times}10^{-3}{\mu}mol-1.0{\times}10^{-2}{\mu}mole$ showed linearity and passed through the origin.

  • PDF

Dynamic Analysis on a Hydraulic Press for Micro-Stamping Using Sensitivity Analysis (감도 해석을 이용한 미세 스탬핑 장치의 동적 해석)

  • Choi H. G.;Lee J. W.;Kim M. J.;Lee D. S.;Lee J. M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.05a
    • /
    • pp.221-224
    • /
    • 2001
  • The dynamic characteristics of a hydraulic press for micro-stamping are investigated by Finite Element Analysis. This machine requires high precision in producing milli-structure of electric products such as TFT-LCD back-up light reflector. First, the modal analysis of the parts and the assembly of the hydraulic press is performed. Then, the sensitivity analysis is carried out. The results show that the bearing stiffness and the base mounting stiffness affect the specific mode shapes.

  • PDF

Characteristic Studies for Scan-Field Size and Visibility of Current Image in a Low Voltage Micro-Column (저 전압 초소형 전자칼럼의 주사면적 크기 및 전류영상 특성 연구)

  • Noriyuki, Ichimura;Kim, Young-Chul;Kim, Ho-Seob;Jang, Won-Kweon
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.5
    • /
    • pp.365-369
    • /
    • 2008
  • The optimal condition for focusing an electron beam was investigated employing an electrostatic deflector in a low voltage micro-column. At fixed voltage of the electron emission tip, the focusing electron beam with source lens showed a larger scan field size and poorer visibility than those with an Einzel lens. Theoretical 3-D simulation indicated that a focusing electron beam with a source lens should have a larger spot size and deflection than those of a focusing Einzel lens.

Development of Conductivity Cell and Suppressor for Capillary Column Ion Chromatography (모세관 컬럼 이온 크로마토그래피를 위한 Conductivity Cell과 Suppressor의 개발)

  • Pyo, Dongjin;Kim, Hohyun
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.89-93
    • /
    • 1999
  • In this study, conductivity cell and suppressor for micro-column ion chromatography were developed to analyze ions in small columns of samples. With a capillary column, the flow rate of the mobile phase is so small (usually $5{\sim}20{\mu}L/min$) that the usual conductivity cell can not be used. Therefore, we developed a new type of conductivity cell and suppressor which have small inner volumes. The conductivity cell was made with two Pt hypodermic needles (i.d. 0.010 mm) which are slightly separated (about $2{\mu}m$), and the suppressor was made of Nafion tubings. When several anions(fluoride, nitrite, nitrate, chlorate) were analyzed using developed conductivity cell and suppressor, a good chromatogram was obtained.

  • PDF

PYE [2-(1-pyrenyl)ethyldimethylsilylated silica] Column HPLC and HR-GC-(micro) ECD in the Accurate Determination of Toxic Co-planar PCBs and Polybrominated Diphenyl Ethers (PBDEs)

  • Kannan, Narayanan;Hong, Sang-Hee;Oh, Jae-Ryoung;Yim, Un-Hyuk;Li, Donghao;Shim, Won-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.4
    • /
    • pp.529-536
    • /
    • 2005
  • Measurement of toxicologically relevant polychlorinated biphenyl (PCB) congeners such as non-ortho(IUPAC#) 77, 81, 126, 169 and mono-ortho 105, 114, 118, 123, 156, 157, 189 and di-ortho 170, 180 and polybrominated diphenyl ethers (PBDEs) such as 47, 66, 85, 99, 100, 138, 153, 154 in environmental samples become almost mandatory in several countries now. However, most of the available methods involve expensive instrumentations such as HRGC-HRMS or ECNI-LRMS, apart from expensive extraction and clean-up (with large volume of solvents) steps. A method has been devised combining the analytical separation power of PYE [2-(1-pyrenyl)ethyldimethysilylated silica] column HPLC and high-resolution gas chromatographic techniques including micro-electron capture detection (ECD) and two dimensional gas chromatograpy-ECD techniques to determine these eco-toxic substances at parts-per-trillion (ppt) levels. This combination resolves co-elution of congeners that occur in disproportionate ratios (e.g. CB-110 and -77) and allows accurate congener-specific determination of target compounds. This method is cost effective as it requires only hexane, that in small quantities (10 mL) and GC-ECD. The elution and analysis time are optimized to less man hours. This method is effectively utilized in the analysis of co-planar PCBs and PBDEs from archived solvent extracts of samples previously analyzed for pesticides and PCBs. Structure based separation of contaminant classes improves GCECD determination at ppt levels.

Conformal coating of Al-doped ZnO thin film on micro-column patterned substrate for TCO (TCO 응용을 위한 패턴된 기판위에 증착된 AZO 박막의 특성 연구)

  • Choi, M.K.;Ahn, C.H.;Kong, B.H.;Cho, H.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.28-28
    • /
    • 2009
  • Fabrications of antireflection structures on solar cell were investigated to trap the light and to improve quantum efficiency. Introductions of patterned substrate or textured layer for Si solar cell were performed to prevent reflectance and to increase the path length of incoming light. However, it is difficult to deposit conformally flat electrode on perpendicular plane. ZnO is II-VI compound semiconductor and well-known wide band-gap material. It has similar electrical and optical properties as ITO, but it is nontoxic and stable. In this study, Al-doped ZnO thin films are deposited as transparent electrode by atomic layer deposition method to coat on Si substrate with micro-scale structures. The deposited AZO layer is flatted on horizontal plane as well as perpendicular one with conformal 200 nm thickness. The carrier concentration, mobility and resistivity of deposited AZO thin film on glass substrate were measured $1.4\times10^{20}cm^{-3}$, $93.3cm^2/Vs$, $4.732\times10^{-4}{\Omega}cm$ with high transmittance over 80%. The AZO films were coated with polyimide and performed selective polyimide stripping on head of column by reactive ion etching to measure resistance along columns surface. Current between the micro-columns flows onto the perpendicular plane of deposited AZO film with low resistance.

  • PDF

Characterization of gas-water flow in tight sandstone based on authentic sandstone micro-model

  • Liu, Yuqiao;Lyu, Qiqi;Luo, Shunshe
    • Geosystem Engineering
    • /
    • v.21 no.6
    • /
    • pp.318-325
    • /
    • 2018
  • Eight tight sandstone reservoir samples from $He_8$ and $Shan_1$ Formations of the Sulige Gas field were selected to perform gas-water micro-displacement experiment based on authentic sandstone micro-model. The gas pressure-relief experiment was proposed for the first time to simulate the pressure change and gas-water percolation characteristics in the process of gas exploitation. The experiment results show that: (1) In the process of gas accumulation, the gas preferentially flows into the well-connected pores and throats with large radius, but rarely flows into the area without pores and throats. (2) Under sufficient gas drive, the water in pores and throats usually exists in the forms of 'thin water film', 'thick water film', and 'water column', but under insufficient gas drive, gas fails to flow into new pathways in time, so that the reservoirs with large pores and throats are high in water cut. (3) Under the same water saturation, the reservoirs with better petrophysical properties has higher gas recovery factor within unit time. Under the same petrophysical conditions, the reservoirs with lower water saturation show higher gas recovery factor within unit time. The higher the permeability, the stronger the liquid carrying capacity of reservoirs.