• 제목/요약/키워드: micro column

검색결과 122건 처리시간 0.029초

Simple and Sensitive Determination of Baclofen in Human Plasma by Column-Switching and Semi-Micro High-Performance Liquid Chromatography

  • Ban, Eun-Mi;Ko, Hye-Ran;Kim, Chong-Kook
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.284.2-284.2
    • /
    • 2003
  • Using a column-switching technique. highly sensitive and selective semi-micro high-performance liquid chromatographic (HPLC) method has been developed for the determination of baclofen in human plasma. Following precipitation of plasma sample containing baclofen with zinc sulfate-acetonitrile, samples were directly injected on to the system. (omitted)

  • PDF

활성탄입경(活性炭粒徑)이 Trihalomethane의 흡착(吸着)에 미치는 영향(影響) (Effects of Particle Size on Adsorption of Trihalomethane by Activated Carbon)

  • 정태학;최상일
    • 대한토목학회논문집
    • /
    • 제4권2호
    • /
    • pp.25-33
    • /
    • 1984
  • 활성탄(活性炭)의 입경변화(粒徑變化)가 trihalomethane의 흡착(吸着)에 미치는 영향(影響)에 관하여 실험적(實驗的)으로 연구(硏究)하였다. 실험(實驗)에 사용(使用)된 활성탄(活性炭)은 평균입경(平均粒徑)이 0.73mm에서 2.03mm까지의 4종류(種類)이었으며 이들에 대하여 물리적(物理的) 특성(特性)을 조사(調査)하고 trihalomethanedml 흡착능력(吸着能力)을 등온흡착실험(等溫吸着實驗)과 micro-column 실험(實驗)을 통해 밝혀냈다. 입경(粒徑)의 증가(增加)에 따라 비표면적(比表面積)이 감소(減少)하였고 활성탄(活性炭) 내부공극(內部空隙)의 반경(半徑)이 크게 증가(增加)하였다. 또한 큰 입자(粒子)의 경우에는 공극(空隙)의 크기가 넓게 분포(分布)하였다. Trihalomethane의 흡착(吸着)은 Freundlich 공식(公式)에 의해 잘 표현(表現)되었고 입경증가(粒徑增加)에 따라 흡착능력(吸着能力)의 감소(減少)가 뚜렷하게 나타났다. Micro-column 실험결과(實驗結果)와 모형(模型)의 Simulation으로부터 물질도달계수(物質導達係數)와 내부표면광산계수(內部表面壙散係數)를 산정(算定)하였다. 입경변화(粒徑變化)에 따른 계수(係數)의 변화(變化)는 무시(無視)할 수 있었으며 입경변화(粒徑變化)에 따른 효율(効率)의 차이(差異)는 주로 흡착능력(吸着能力)의 차이(差異)에서 오는 결과(結果)로 판단(判斷)된다.

  • PDF

용융 메탈 잉크젯 시스템 (Molten Metal Inkjet System)

  • 이택민;강태구;양정순;조정대;김광영;김동수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.585-586
    • /
    • 2006
  • In this paper, we present a design, analysis, fabrication and performance test of the novel DoD metal-jet system for application to the high-density and high-temperature-melting materials. Based on the theoretical analysis, we design the metal-jet print head system and fabricate the metal-jet system, which can eject the droplet of lead-free metal solder in the high-temperature. In the experimental test, we set up the test apparatus for visualization of the droplet ejection and measure the Ejected droplet volume and velocity. As a result, the diameter, volume and the velocity of the ejected droplet are about $65-70{\mu}m$, 145-180 pl and 4m/sec. We also fabricate vertical and inclined 3D micro column structures using the present molten metal inkjet system. The measured geometries of the micro column structures are about height of $2,100{\mu}m$, diameter of $200{\mu}m$ and aspect ratio of 10.5 for vertical micro column and $1,400{\mu}m$ of height and $150{\mu}m$ of diameter for $65^{\circ}$-inclined micro column, respectively.

  • PDF

마이크로 금형 가공 및 사출성형에 관한 연구 (Micro Parts Machining and Injection Molding Technology)

  • 최두선;제태진;이응숙;신보성
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.452-457
    • /
    • 2003
  • As a fundamental study on developing elements with micro shape, micro mold parts machining and experiment of injection molding using it were performed. The ultra precision micro machining system with high functionality was fabricated, and utilized in the machining of micro parts. By using this machining system and micro end-mill tool, a micro circle column structure of high aspect ratio, diameter 60 $\mu\textrm{m}$, height 500 $\mu\textrm{m}$, was fabricated. And a micro lens molds were fabricated by using ball end-mill tool of 300 $\mu\textrm{m}$ diameter and diamond fly-cut tool of 150 $\mu\textrm{m}$ radius. A micro injection molding machine, which is clamping force 1.75 ton, injection capacity 2.8cc, was fabricated for injection molding experiment using micro molds. The injection molding experiment was performed by using the injection molding machine, micro cylinder structures and lens molds. This paper introduces these micro machining system and injection molding machine and demonstrates examples of injection molding using fabricated molds.

  • PDF

A Sperm Factor Inducing Second Polar Body Formation in Mouse Secondayy Oocyte

  • Park, Y.S;Min, S.H.
    • 한국가축번식학회지
    • /
    • 제26권4호
    • /
    • pp.369-375
    • /
    • 2002
  • A sperm factor(s) for oocyte activation during fertilization has not been clearly identified. In this study to elucidate an oocyte activation factor(s), mouse sperm were sonicated and ultra-filtered with a 30 kilo-daltons (KD) cutoff membrane and the ultra-filtrate was then sequentially fractionated over Suporose 12 column and Superdex column, The recovered fractions were micro-injected into Mⅱmouse oocytes and second polar body formation (PBF) was examined. Suporose fraction RV2.10 prepared from sperm extract significantly increased PBF. Of Superdex fractions re-separated from Suporose fraction RV2.10, fraction RV2.12 also had the strongest PBF activity. By analyzing with micro-reverse phase column (URPC), the Superdex fraction RV2.12 appeared to be glutamic acid. In microinjection test, glutamic acid significantly increased PBF. This study suggests that glutamic acid should be a type of sperm factor for second polar body formation related to oocyte activation.

디지털 현미경 홀로그래피 기법을 이용한 마이크로 액체 제트 유동에 관한 실험적 연구 (Experimental Study on the Characteristics of Micro Jet Flow Using Digital Microscopic Holography)

  • 이한얼;이재호;신원규
    • 한국가시화정보학회지
    • /
    • 제16권1호
    • /
    • pp.48-53
    • /
    • 2018
  • In this study, the effect of injection pressure on the column diameter and droplet velocity of liquid jet with the weakly turbulent Rayleigh-like breakup mode is experimentally studied using digital microscopic holography (DMH). The injection nozzle has the diameter of $50{\mu}m$ and injection pressure is varied from 0.1 to 0.4 MPa. When the micro liquid jet is injected into still air, the double-pulsed holograms was recorded on a CCD sensor and numerically reconstructed in order to obtain well focused images. In this study, the liquid column diameter from $50{\mu}m$ orifice nozzle is shown to be changed slightly but the droplet velocity is increased proportionally as the injection pressure is increased.

Pulsed Electrochemical Deposition for 3D Micro Structuring

  • Park, Jung-Woo;Ryu, Shi-Hyoung;Chu, Chong-Nam
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제6권4호
    • /
    • pp.49-54
    • /
    • 2005
  • In this paper, micro structuring technique using localized electrochemical deposition (LECD) with ultra short pulses was investigated. Electric field in electrochemical cell was localized near the tool tip end region by applying pulses of a few hundreds of nano second duration, Pt-Ir tip was used as a counter electrode and copper was deposited on the copper substrate in mixed electrolyte of 0.5 M $CuSO_4$ and 0.5 M $H_2SO_4$, The effectiveness of this technique was verified by comparison with ECD using DC voltage. The deposition characteristics such as size, shape, surface, and structural density according to applied voltage and pulse duration were investigated. The proper condition was selected based on the results of the various experiments. Micro columns less than $10{\mu}m$ in diameter were fabricated using this technique. The real 3D micro structures such as micro spring and micro pattern were made by the presented method.

$\mu$-HPLC의 Column-Switching 기술을 이용한 식품중 비타민 $B_{12}$의 분석 (Determination of Vitamin $B_{12}$ in Foods Using Column-Switching Technique in $\mu$-HPLC)

  • 박성진;김혜경;함태식;김병용
    • 한국식품영양과학회지
    • /
    • 제28권6호
    • /
    • pp.1208-1211
    • /
    • 1999
  • Semi HPLC using a column switching technique was used to determine the trace content of vitamin B12 in various foods. Total analytical time required less than 20 mins per sample and the recovery ratio was 99.9, 99.6, 100.1 and 99.8% for 1.0, 10.0, 100.0 and 1,000 g/kg, respectively. The content of vitamin B12 in various foods obtained using column switching method showed higher levels compared to labels in dried milk(0.5 g/100g) and in grain products(0.51~34.36 g/100g). Thus, this column switching method was more sensitive, effective and precise than the microbiological analysis currently used to determine the trace compounds like a vitamin B12.

  • PDF

Microfluidic Biosensor System for HDL Cholesterol

  • Kim, Joo-Eun;Paek, Se-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XIII)
    • /
    • pp.717-720
    • /
    • 2003
  • A chromogenic biosensor employing microfluidics on a chip has been developed for the determination of high-density lipoprotein (HDL) cholesterol (HDL-C) in human serum. We have investigated a plain and effective method to immobilize enzymes within the microchip without chemically modifying micro-channel or technically micro-fabricating column reactor and fluid channel network. In assessing risk factors of coronary heart disease, a micro-chip system would minimize requirements of instrument and reagent handling.

  • PDF