• Title/Summary/Keyword: micro blood vessel

Search Result 27, Processing Time 0.026 seconds

In Vivo Measurements of Blood Flow in a Chicken Embryo Using Micro PIV Technique (유정란 배아 혈액유동의 in vivo 계측)

  • Yeo Chang-Sub;Han Kyu-Yeon;Lee Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.4 s.247
    • /
    • pp.314-319
    • /
    • 2006
  • To analyze in-vivo blood flow characteristics in a chicken embryo, in-vivo experiment was carried out using micro-PIV technique. Because endothelial cells in blood vessels are subject to shear stress of blood flow, it is important to get velocity field information of the placental blood flow. Instantaneous velocity fields of an extraembryonic blood vessel using a high-speed camera and intravital microscope. The flow images of RBCs were obtained with a spatial resolution of $20\times20{\mu}m$ in the whole blood vessels. The mean velocity field data confirm that the blood flow does show non-Newtonian fluid characteristic. The blood in a branched vessel merged smoothly without any flow separation into the main blood vessel with the presence of a slight bump. This in-vivo micro-PIV measurement technique can be used as a powerful tool in various blood flow researches.

Hemodynamic Analysis of Blood Flows in the Extraembryonic Blood Vessels of Chicken Embryos (유정란 태아외부혈관 내부 혈액유동에 대한 혈류역학적 연구)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.6-9
    • /
    • 2008
  • Analyzing the characteristics of blood flow in the blood vessels is very important to diagnose the circulatory diseases. In order to investigate the hemodynamic characteristics in vivo, the measurements of blood flows inside the extraembryonic arterial and venous blood vessels of chicken embryos were carried out using an in vivo micro-PIV technique. The circulatory diseases are closely related with the formation of abnormal hemodynamic shear stress regions, thereby it is important to get blood velocity and vessel's morphological information according to the vessel configuration and the flow conditions. In this study, the flow images of RBCs in blood vessels were obtained using a high-speed CMOS camera with a spatial resolution of approximately 14.6${\mu}$m${\times}$14.6${\mu}$m in the whole circulation network of blood vessels. The blood flows in the veins and arteries show steady laminar and unsteady pulsatile flow characteristics, respectively. The mean blood flows merged (in veins) and bifurcated (in arteries) smoothly into the main blood vessel and branches, respectively, without any flow separation or secondary flow which accompanying large variation of shear stress. Vorticity was high in the inner regions for both types of vessels, where the radius of curvature varied greatly. The instantaneous flows in the arterial blood vessels showed noticeable pulsatility due to the heart beat, and the main features of the velocity waveforms, including pulsatile shape, retrograde flow, mean velocity, maximum velocity and pulsatile frequency, were significantly dependent on the pulsatile condition which dominates the arterial blood flow. In near future, these in vivo experimental results of blood flow measured in various extraembryonic blood vessels would be very useful to understand the hemodynamic characteristics of human blood flows and various blood flow researches for clinically useful hemodynamic discoveries as well.

  • PDF

Numerical Simulation of Pulsatile Flows around Micro-Stenosis for Blood Analog Fluids (혈액모사유체의 미세협착 주변 맥동유동 시뮬레이션)

  • Song, Jae Min;Hong, Hyeonji;Ha, Yi Kyung;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.2
    • /
    • pp.10-16
    • /
    • 2019
  • Considering the role of viscosity in the hemorheology, the characteristics of non-Newtonian fluid are important in the pulsatile blood flows. Stenosis, with an abnormal narrowing of the vessel, contributes to block blood flows to downstream tissue and lead to plaque rupture. Therefore, systematic analysis of blood flow around stenosed vessels is crucial. In this study, non-Newtonian behaviors of blood analog fluids around the micro-stenosis with 60 % severity in diameter of $500{\mu}m$ was examined by using CFX under the pulsatile flow conditions with the period of 10 s. Viscosity information of two non-Newtonian fluids were obtained by fitting the value of normal blood and highly viscous blood. As the Newtonian fluid, the water at room temperature was used. During the pulsatile phase, wall shear stress (WSS) is highly oscillated. In addition, high viscous solution gives rise to increases the variation in the WSS around the micro-stenosis. Highly oscillating WSS enhance increasing tendency of plaque instability or rupture and damage of the tissue layer. These results, related to the influence on the damage to the endothelium or stenotic lesion, may help clinicians understand relevant mechanisms.

Hemodynamical analysis by viscosity characteristics of artificial blood for μ-PIV experiment of Radio-cephalic arteriovenous fistula(RC-AVF) (μ-PIV기법을 이용한 동정맥루 모사혈관에서의 모사 혈액의 점도특성에 따른 혈류역학적 분석)

  • Song, Ryungeun;Lee, Jinkee
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.1
    • /
    • pp.33-39
    • /
    • 2016
  • Radio-cephalic arteriovenous fistula(RC-AVF) is the most recommended operation of achieving access for hemodialysis. However, it has high rates of early failure depending on the many haemodynamic conditions. To increase RC-AVF patency rate, many researches were performed by in-vitro experiment via artificial vessel and blood analogue fluid, and there were conflicting opinions about whether the non-Newtonian properties of blood have an influence on the flow in large arteries. To investigate the influence of viscoelasticity of blood within the RC-AVF, we fabricated three dimensional artificial RC-AVF and two kinds of blood analogue fluid. The velocity field of two fluids within the vessel were measured by micro-particle velocimetry(m-PIV) and compared with each other. The velocity profiles of both fluids for systolic phase were matched well while those for diastolic phase did not correspond. Therefore, it is desired to use non-newtonian fluid for in-vitro experiment of RC-AVF.

An Electrical Characteristics Analysis of Electronic Blood Pressure Depressor (전자혈압강하기의 전기적 특성 분석)

  • Lee, K.S.;Suh, J.H.;Lee, J.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.83-89
    • /
    • 2006
  • Recently, the seriousness of high blood pressure was appeared as the most frequent disease of a the whole sickness in the world. However, the treatment of this disease is uncertain and produces an adverse reaction of a medicine therapy. Also, the patients are burdened with a fee for medical treatment. Therefore, in this paper, we studied effectively and financially to execute the treatment of high blood pressure using the Chinese medicine theorem that is recently arousing the great interest of the people. The main theories in this paper are blood vessel theory and acupuncture, respectively. Especially, the composed circuit systems are classified the blood pressure depressor part and the meridian points discrimination part, respectively. The blood pressure depressor part is composed generally of low-frequency generation circuit, charging-discharging circuit, and micro-computer circuit. Finally, this research have the advantage of discrimination parts such as regular voltage generating circuit, stimulus circuit, amplifying circuit, and alarm circuit.

  • PDF

Red Blood Cell Velocity Field in Rat Mesenteric Arterioles Using Micro PIV Technique

  • Sugii, Y;Nishio, S;Okamoto, K;Nakano, A;Minamiyama, M;Niimi, H
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.24-31
    • /
    • 2003
  • As endothelial cells are subject to flow shear stress, it is important to determine the detailed velocity distribution in microvessels in the study of mechanical interactions between blood and endothelium. This paper describes a velocity field of the arteriole in the rat mesentery using an intravital microscope and high-speed digital video system obtained by a highly accurate PIV technique. Red blood cells (RBCs) velocity distributions with spatial resolutions of $0.8{\times}0.8{\mu}m$ were obtained even near the wall in the center plane of the arteriole. By making ensemble-averaged time-series of velocity distributions, velocity profiles over different cross-sections were calculated for comparison. The shear rate at the vascular wall also evaluated on the basis of the ensemble-averaged profiles. It was shown that the velocity profiles were blunt in the center region of the vessel cross-section while they were steep in the near wall region. The wall shear rates were significantly small, compared with those estimated from the Poiseuille profiles.

  • PDF

A Development of Electronic Blood Pressure Depressor Using Ear Acupuncture of Chinese Medicine (한방이침법을 이용한 전자혈압강하기 개발)

  • Kim, J.H.;Kim, S.T.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2712-2714
    • /
    • 2002
  • Recently, the high blood pressure is appeared the most frequent disease of a man's the whole sickness. But, to treat this disease is uncertain and produces an adverse reaction of a medicine therapy. Also, a patients are burden high price for doctor's treatment. Therefore, we studied effectively and financially to execute the treatment of the high blood pressure using the Chinese Medicine Theorem that recently arousing a great interest of the people. The main theories of this paper are Blood Vessel Theory and Acupuncture. The composed circuits are low-frequency generating circuit, charging-discharging circuit. The former will substitute a needle that use in the acupuncture therapy method and the latter will charge and discharge the bioelectric action potential of a patient in Ear Acupuncture Point. Also, all circuits will be controlled a micro-computer circuit.

  • PDF

In-vivo Measurements of Blood Flow Characteristics in the Arterial Bifurcation Cascade Networks of Chicken Embryo (유정란 태아외부혈관의 단계적으로 분기되는 동맥 분지관 내부 혈액 유동특성의 in-vivo 계측)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.121-124
    • /
    • 2006
  • The arteries are very important in cardiovascular system and easily adapt to varying flow and pressure conditions by enlarging or shrinking to meet the given hemodynamic demands. The blood flow in arteries is dominated by unsteady flow phenomena due to heart beating. In certain circumstances, however, unusual hemodynamic conditions cause an abnormal biological response and often induce circulatory diseases such as atherosclerosis, thrombosis and inflammation. Therefore quantitative analysis of the unsteady pulsatile flow characteristics in the arterial blood vessels plays important roles in diagnosing these circulatory diseases. In order to verify the hemodynamic characteristics, in-vivo measurements of blood flow inside the extraembryonic arterial bifurcation cascade of chicken embryo were carried out using a micro-PIV technique. To analyze the unsteady pulsatile flow temporally, the (low images of RBCs were obtained using a high-speed CMOS camera at 250fps with a spatial resolution of $30{\mu}m\times30{\mu}m$ in the whole blood vessels. In this study, the unusual flow conditions such as flow separation or secondary flow were not observed in the arterial bifurcations. However, the vorticity has large values in the inner side of curvature of vessels. In addition, the mean velocity in the arterial blood vessel was decreased and pulsating frequency obtained by FFT analysis of velocity data extracted in front of the each bifurcation was also decreased as the bifurcation cascaded.

  • PDF

The Essential Function of miR-5739 in Embryonic Muscle Development

  • Ji-Heon Lee;Min Sup Kim;Jin-seop Lee;Dong Hyun Lee;Chansol Park;Dong Hyuk Lee;Eun-Young Kim;Hyung Min Chung
    • International Journal of Stem Cells
    • /
    • v.16 no.2
    • /
    • pp.145-155
    • /
    • 2023
  • Background and Objectives: Embryologically, mesodermal development is closely related to the development of various organs such as muscles, blood vessels, and hearts, which are the main organs that make up the body. However, treatment for mesoderm developmental disorders caused by congenital or acquired factors has so far relied on surgery and drug treatment for symptom relief, and more fundamentally, treatment for mesoderm developmental disorders is needed. Methods and Results: In our study, microRNA (miRNA), which plays an important role in the mesoderm development process, was identified and the developmental function was evaluated. miRNAs consist of small nucleotides, which act as transcription factors that bind to the 3' untranslated region and suppressed target gene expression. We constructed the human embryonic stem cell (hESC) knockout cell line and analyzed the function and characteristics of miR-5739, which plays an important role in mesoderm lineage. miR-5739 acts as a transcription factor targeting SMA, Brachyury T, Hand1, which controls muscle proliferation and differentiation, and KDR gene, which regulates vessel formation in vitro. In vivo results suggest a role in regulating muscle proliferation and differentiation. Gene ontology analysis confirmed that the miR-5739 is closely related to genes that regulate muscle and vessel proliferation and differentiation. Importantly, abnormal expression of miR-5739 was detected in somatic cells derived from patients with congenital muscle disease. Conclusions: Our study demonstrate that miR-5739 gene function significantly affects transcriptional circuits that regulate muscle and vascular differentiation during embryonic development.

Effect of 4-hexylresorcinol on Blood Coagulation and Healing of Injured Vessel in a Rat Model

  • Park, Yong-Tae;Park, Si-Yeok;Kim, Min-Keun;Kim, Seong-Gon;Park, Young-Wook;Kwon, Kwang-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.5
    • /
    • pp.284-293
    • /
    • 2013
  • Purpose: For reconstruction of craniomaxillofacial defects caused by tumor, trauma, infection etc, free flap transplantation with microvascular surgery is a very useful method. Thrombus formation at the anastomosis site is the major cause of graft failure. 4-Hexylresorcinol (4-HR) is generally known as an antiseptic and antiparasitic agent. This study was conducted in order to evaluate the effect of 4-HR on blood coagulation in vitro. In addition, we investigated thrombus formation and endothelial repair of an injured vessel in an animal model. Methods: In the in vitro experiment, we compared blood coagulation time between the 4-HR treated group and normal blood. Thirty rats were used for in vivo animal experiments. After exposure of the right femoral vein, a micro vessel clamp was placed and the femoral vein was intentionally cut. Microvascular anastomosis was performed on all rats using 10-0 nylon under microscopy. The animals were divided into two groups. In the experimental group (n=15), 4-HR (250 mg/kg) mixed with olive oil (10 mL/kg) was administered per os daily. Animals in the control group (n=15) were given olive oil only. The animals were sacrificed at three days, seven days, and fourteen days after surgery and rat femoral vein samples were taken. Vascular patency and thrombus formation were investigated just before sacrifice. Histologic analysis was performed under a microscope. Results: Results of an in vitro blood coagulation test showed that coagulation time was delayed in the 4-HR treated group. The results obtained from an in vivo 4-HR administered rat model showed that the patency of all experimental groups was better at thirty minutes, seven days, and fourteen days after microvascular anastomosis than that of the control group at seven and fourteen days after anastomosis, and the amount of thrombus in the experimental groups was much less than that of the control group. Endothelial repair was observed in the histologic analysis. Conclusion: Findings of this study demonstrated that blood coagulation was delayed in the vitro 4-HR treated group. In addition, good vascular patency, anti-thrombotic effect, and repair of venous endothelial cells were observed in the vivo 4-HR administered rat group.