DOI QR코드

DOI QR Code

Numerical Simulation of Pulsatile Flows around Micro-Stenosis for Blood Analog Fluids

혈액모사유체의 미세협착 주변 맥동유동 시뮬레이션

  • Song, Jae Min (Department of Oral and Maxillofacial Surgery, School of Dentistry, PNU) ;
  • Hong, Hyeonji (School of Mechanical Engineering, PNU) ;
  • Ha, Yi Kyung (College of Nursing, PNU) ;
  • Yeom, Eunseop (School of Mechanical Engineering, Pusan National University (PNU))
  • Received : 2019.07.05
  • Accepted : 2019.08.10
  • Published : 2019.08.31

Abstract

Considering the role of viscosity in the hemorheology, the characteristics of non-Newtonian fluid are important in the pulsatile blood flows. Stenosis, with an abnormal narrowing of the vessel, contributes to block blood flows to downstream tissue and lead to plaque rupture. Therefore, systematic analysis of blood flow around stenosed vessels is crucial. In this study, non-Newtonian behaviors of blood analog fluids around the micro-stenosis with 60 % severity in diameter of $500{\mu}m$ was examined by using CFX under the pulsatile flow conditions with the period of 10 s. Viscosity information of two non-Newtonian fluids were obtained by fitting the value of normal blood and highly viscous blood. As the Newtonian fluid, the water at room temperature was used. During the pulsatile phase, wall shear stress (WSS) is highly oscillated. In addition, high viscous solution gives rise to increases the variation in the WSS around the micro-stenosis. Highly oscillating WSS enhance increasing tendency of plaque instability or rupture and damage of the tissue layer. These results, related to the influence on the damage to the endothelium or stenotic lesion, may help clinicians understand relevant mechanisms.

Keywords

References

  1. Toraldo, D. M., Peverini, F., De Benedetto, M. and De Nuccio, F., 2013, "Obstructive Sleep Apnea Syndrome: Blood Viscosity, Blood Coagulation Abnormalities, and Early Atherosclerosis," Lung, Vol. 191, No. 1, pp. 1-7. https://doi.org/10.1007/s00408-012-9427-3
  2. Yeom, E., 2018, "Different Adhesion Behaviors of Platelets Depending on Shear Stress around Stenotic Channels," Journal of Visualization, Vol. 21, No. 1, pp. 95-104. https://doi.org/10.1007/s12650-017-0446-2
  3. Cheng, C., Tempel, D., van Haperen, R., van der Baan, A., Grosveld, F., Daemen, M. J., Krams, R. and de Crom, R., 2006, "Atherosclerotic Lesion Size and Vulnerability Are Determined by Patterns of Fluid Shear Stress," Circulation, Vol. 113, No. 23, pp. 2744-2753. https://doi.org/10.1161/CIRCULATIONAHA.105.590018
  4. Kuo, L., Davis, M. J., Cannon, M. S. and Chilian, W. M., 1992, "Pathophysiological Consequences of Atherosclerosis Extend into the Coronary Microcirculation-Restoration of Endothelium-Dependent Responses by L-Arginine," Circulation Research, Vol. 70, No. 3, pp. 465-476. https://doi.org/10.1161/01.RES.70.3.465
  5. Hong, H., Song, J. M. and Yeom, E., 2019, "Variations in Pulsatile Flow around Stenosed Microchannel Depending on Viscosity," PLOS ONE, Vol. 14, No. 1, pp. e0210993. https://doi.org/10.1371/journal.pone.0210993
  6. Anastasiou, A. D., Spyrogianni, A. S., Koskinas, K. C., Giannoglou, G. D. and Paras, S. V., 2012, "Experimental Investigation of the Flow of a Blood Analogue Fluid in a Replica of a Bifurcated Small Artery," Med Eng Phys, Vol. 34, No. 2, pp. 211-218. https://doi.org/10.1016/j.medengphy.2011.07.012
  7. Downing, G. J., Yarlagadda, A. P. and Maulik, D., 1991, "Comparison of the Pulsatility Index and Input Impedance Parameters in a Model of Altered Hemodynamics," J Ultrasound Med, Vol. 10, No. 6, pp. 317-321. https://doi.org/10.7863/jum.1991.10.6.317
  8. Ozcan, T., Sbracia, M., d'Ancona, R. L., Copel, J. A. and Mari, G., 1998, "Arterial and Venous Doppler Velocimetry in the Severely Growth-Restricted Fetus and Associations with Adverse Perinatal Outcome," Ultrasound in Obstetrics & Gynecology, Vol. 12, No. 1, pp. 39-44. https://doi.org/10.1046/j.1469-0705.1998.12010039.x
  9. Yeom, E. and Lee, S. J., 2015, "Relationship between Velocity Profile and Ultrasound Echogenicity in Pulsatile Blood Flows," Clinical Hemorheology & Microcirculation, Vol. 59, No. 3, pp. 197-209. https://doi.org/10.3233/CH-131759
  10. Samady, H., Eshtehardi, P., McDaniel, M. C., Suo, J., Dhawan, S. S., Maynard, C., Timmins, L. H., Quyyumi, A. A. and Giddens, D. P., 2011, "Coronary Artery Wall Shear Stress Is Associated with Progression and Transformation of Atherosclerotic Plaque and Arterial Remodeling in Patients with Coronary Artery Disease," Circulation, Vol. 124, No. 7, pp. 779-788. https://doi.org/10.1161/CIRCULATIONAHA.111.021824
  11. Walker, A. M., Scott, J., Rival, D. E. and Johnston, C. R., 2014, "In Vitro Post-Stenotic Flow Quantification and Validation Using Echo Particle Image Velocimetry (Echo Piv)," Experiments in Fluids, Vol. 55, No. 10, pp. 1-16.
  12. Nejad, A. A., Talebi, Z., Cheraghali, D., Shahbani-Zahiri, A. and Norouzi, M., 2018, "Pulsatile Flow of Non-Newtonian Blood Fluid inside Stenosed Arteries: Investigating the Effects of Viscoelastic and Elastic Walls, Arteriosclerosis, and Polycythemia Diseases," Computer Methods & Programs in Biomedicine, Vol. 154, No. 1, pp. 109-122. https://doi.org/10.1016/j.cmpb.2017.11.016
  13. Lowe, G. D., 1992, "Blood Viscosity, Lipoproteins, and Cardiovascular Risk," Circulation, Vol. 85, No. 6, pp. 2329-2331. https://doi.org/10.1161/01.CIR.85.6.2329