AC Electrical Breakdown Characteristics of an Epoxy/Mica Composite

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.4
    • /
    • pp.200-203
    • /
    • 2012
  • Epoxy/mica composite was synthesized, in order to use it as an impregnation resin in a vacuum pressure impregnation (VPI) process, for manufacturing a high voltage rotary machine. The average particle size of the mica was 5~7 ${\mu}m$ and its content was 0, 20, 30 and 40 wt%. A plasticizer or a low molecular aliphatic epoxy was also used, to decrease the viscosity of the composite. The AC electrical breakdown strength was estimated in sphere-to-sphere electrodes, and the electrical breakdown data were estimated by Weibull statistical analysis. The electrical breakdown strength became higher with the addition of mica; and that of the system with 20 wt% mica was highest. The electrical breakdown strength of the system with an aliphatic epoxy was higher than that of the system with a, plasticizer.

A Study of development on Mica/Epoxy Composite (2) (마이카/ 에폭시 복합재료의 개발에 관한 연구(2))

  • Park, Chung-Hoo;Jeung, Eun-Shik;Kim, Ki-Beom
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.216-219
    • /
    • 1987
  • Dielectric and Mechanical Properties of Mica flake/ Epoxy Composite are investigated. The Mica content is about 50 wt % and its thickness is about $240{\mu}m$. The finished Mica flake/Epoxy Composite contains about 0.1-1.0 wt % of aminosilane coupling agent. Ruby Mica filler and high temperature curing Epoxy resin are used. From the viewpoint of dielectric and mechanical properities. the optimum properties is obtained for the sample post cured at $130^{\circ}C$ for 5 h ours after curing at $80^{\circ}C$ for 2 hours and with 0.5 weight % silane coupling agent.

  • PDF

A Study on Thermal, Mechanical and Electrical Properties as Silane Treated Epoxy/MICA Composites (실란처리된 Epoxy/MICA 콤포지트의 열적, 기계적 전기적 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.213-218
    • /
    • 2013
  • In this study, epoxy/mica composite was prepared by mixing with mechanical stirrer together with homogenizer, and the effect of amino-type silane coupling agent was also studied. To reduce the viscosity without any decrement of other properties, 1,4-Butanediol diglycidyl ether (1,4-BDGE) as an aliphatic epoxy reactive diluent was introduced to the epoxy/mica composite in order to use as vanish for high voltage motor and generator stator winding. It was confirmed by scanning electron microscopy (SEM) observation that interfacial characteristics between organic epoxy and inorganic mica was modified by coupling agent treatment so that glass transition temperature increased, and tensile strength and electrical breakdown strength increased. The properties were estimated by Weibull statistical analysis and the ac electrical breakdown strength was 20.2% modified by treating silane coupling agent.

A Study on the Breakdown Mechanism of Rotating Machine Insulation

  • Kim, Hee-Gon;Kim, Hee-Soo;Park, Yong-Kwan
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.3
    • /
    • pp.71-76
    • /
    • 1997
  • A lot of experiments and analyses have been done to determine the aging mechanism of mica-epoxy composite material used for large generator stator windings in order to estimate remaining life of the generator for last decades. After degrading artificially the mica-epoxy composite material, the surface analysis is performed to analyze breakdown mechanism of insulation in air and hydrogen atmosphere; i) In the case of air atmosphere, it is observed that an aging propagation from conductor to core by partial discharge effect and the formation of cracks between layers is widely carbonized surface. ii) In case of hydrogen atmosphere, the partial discharge effect is reduced by the hydrogen pressure (4kg/$\textrm{cm}^2$). Potassium ions forming a sheet of mica is replaced by hydrogen ions, which can lead to microcracks. It is confirmed that the sizes of crack by SEM analysis are 10∼20[$\mu\textrm{m}$] in length under air, and 1∼5[$\mu\textrm{m}$] in diameter, 10∼50[$\mu\textrm{m}$] in length under hydrogen atmosphere respectively. The breakdown mechanism of sttor winding insulation materials which are composed of mica-epoxy is analyzed by the component of materials with EDS, SEM techniques. We concluded that the postassium ions of mica components are replaced by H\ulcorner, H$_3$O\ulcorner at boundary area of mica-epoxy and/or mica-mica. It is proposed that through these phenomena, the conductive layers of potassium enable creation of voids and cracks due to thermal, mechanical, electrical and environmental stresses.

  • PDF

A Study on the Relationship between Aging and Partial Discharge Characteristics of the Mica/Epoxy Composite Insulation Systems (l) (Mica/Epoxy 복합 절연계통의 부분방전 특성과 열화 관계에 관한 연구(I))

  • Kang, D.S.;Lee, W.Y.;Park, C.H.;Kwak, Y.S.;Kim, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.976-979
    • /
    • 1992
  • There are lots of problem which are delaminations and partial discharge of insulation materials in high-voltage rotating machines caused by mechanical, electrical and thermal aging. Several experiments have been aiming at finding the useful diagnostic parameters from the partial discharge characteristics by applying a new measurement techniques. This paper deals with the partial discharge characteristics (pulse height, pulse angle, pulse frequency spectrum and time interval), which may be a useful diagnostic concept in predicting insulation condition of mica/epoxy composite insulation materials, by using several measurement equipments (frequency spectrum analyzer. multichannel analyzer and time interval analyzer).

  • PDF

Analysis of Insulation Aging Mechanism in Generator Stator Windings (발전기 고정자 권선의 절연열화 메카니즘 분석)

  • 김희동
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.119-126
    • /
    • 2002
  • The mica/epoxy composite used in generator(rated 22 kV and 500 MW) stator windings was aged at 180$\^{C}$ for up to 1000 hours in air and hydrogen. The degradation mechanism was investigated through the defect of evolution and microstructural analysis by performing SEM(Scanning Electron Microscope). As the thermal aging time increases, the number of voids per unit volume increases at the mica/epoxy interface of generator stator windings. The aged specimens in hydrogen showed retarded generation and growth of voids. Accelerated aging tests were conducted using the combination of thermal and electrical aging in air and hydrogen. The aging was carried out at a combined stress such as thermal aging at 110$\^{C}$, electrical aging at 5.5 kV/mm and frequencies 420 Hz in air, and electrical aging at 5.5 kV/mm and frequencies 420 Hz in hydrogen (pressure 4 kg/㎠). Thermal and electrical aging generates large voids at the mica/epoxy interface in air. Electrical aging in hydrogen also generates small voids, delaminations and cracks in mica tapes.

Electrical and Chemical Properties of Mica/Epoxy Composite Materials as Affected by Short-Time Aging

  • Kim, Hee-Dong
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.2
    • /
    • pp.59-65
    • /
    • 2003
  • Electrical properties such as permittivity and tan$\delta$ of unaged (control) and aged (72 h at 18$0^{\circ}C$) mica/epoxy composites of 130 ${\mu}{\textrm}{m}$ thickness were measured and their surface conditions were characterized using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), electron spectroscopy for chemical analysis (ESCA), differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). Both permittivity and tan6 of control specimens were higher than those of short-time aged specimens. FTIR results show a new peak at 1710 $cm^{-1}$ / for short-time aged specimens, originating from carbonyl group formed by the oxidation reaction during the aging process. ESCA results show that the binding energy at 532.9 eV representing the singlet state of oxygen ( $O_{1s}$) decreases by 13.7%, whereas that at 534.6 eV increases by 13.7%. Glass transition temperatures of control and short-time aged specimens are observed to be 95.4$^{\circ}C$ and 113.4$^{\circ}C$, which increase with the increase of aging time. TGA results indicate that the control specimens contain a smaller amount of volatile components than the short-time aged specimens.s.

A Study on Partial Discharge Propeties of Interface Layer in-Mica-Epoxy Composite Material (마이카-에폭시 복합절연계 계면층의 부분방전 특성에 관한 연구)

  • 이은학;김태성;박종건;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.83-89
    • /
    • 1991
  • The partial discharge properties of interface layer in Mica-Epoxy composite, which has been mainly used for the coil insulating material of high voltage machinery, are different from those of resins due to the abnormal interface layer to be presented between inorganic material and resin. Accordingly, the study on discharge of interface in composite insulting system is strongly requsted for not only an increasing of insulating strength, but also the basical information of diagnosis system for high voltage equipment. As a result, it has been confirmed that the interface is an abnormal resin layer and the contact states at interface is depended upon the density of silane aqueous solution. Pulse frequency at abnormal interface shows a linear increasing with enlargement of discharge quantity. Whereas, in case of normal interface, pulse frequency property represents exponential increasing at the point of saturating. A life model can be diagramed from results of time dependance of skewness, and a survival life time can be quantified from the life model suggested.

dispersion and relaxation of Epoxy/Layered Nanocomposite (에폭시/나노층상복합재료의 유전분산과 완화)

  • Ahn, Joon-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.87-87
    • /
    • 2010
  • Epoxy/mica has been used as the material of high-voltage rotator stator winding due to its high insulation performance, mechanical strength, and thermal stability. In recent years, however, it shows frequent changes in the load of generators and frequent automatic stops due to the significant increase in peak loads from the increase in the applied load of power facilities according to the introduction of advanced and high-technology equipments. Thus, it is necessary to develop new materials that highly develop the conventional insulation materials. Nanotechnology introduced in the present time has become an alternative plan that overcomes such technical limitations. In addition, the nano-scaled intercalation composite has been known as the material that represent excellent electrical, mechanical, and thermal characteristics compared to the conventional materials. This study investigated the dielectric dispersion and relaxation characteristics of the nanocomposite, which was fabricated by mixing epoxy matrix with nano-scaled intercalation mica and clay, according to changes in frequencies and temperatures.

  • PDF

The Skewness Properties at Interface in Mica-Epoxy Composite (마아카-에폭시 복합재료 계면에서의 왜도 특성)

  • Lim, Jang-Seob;Lee, Eun-Hak;Gu, Hal-Bon;Kim, Tae-Seoung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.128-131
    • /
    • 1992
  • In this paper, the skewness properties of partial discharge at interface layer in mica-epoxy composite material were investigated and studied on interface specimens which has internal electrodes. As a result, it has been confirmed that the interface exists as abnormal resin layer and the contact condition at the interface is depended upon the density of si lane aqueous solution. The Pulse frequency of discharge at abnormal interface has been shown a linear increasing with enlargement of discharge quantity according to rising of the applied voltage. Whereas, in case of normal interface, pulse frequency represented exponential increasing at the saturating point of discharge quantity. The aging model can be represented from the variable characteristics of skewness.

  • PDF