• 제목/요약/키워드: metrology

검색결과 723건 처리시간 0.027초

Improved Method and Message Structure Design for TWSTFT without Extra Network

  • Juhyun Lee;Ju-Ik Oh;Young Kyu Lee;Sung-hoon Yang;Jong Koo Lee;Joon Hyo Rhee
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권2호
    • /
    • pp.201-209
    • /
    • 2023
  • Time comparison techniques are required for generating and keeping Coordinated Universal Time (UTC) and to distribute standard clocks. These techniques play an important role in various fields, including science, finance, military, and communication. Among these techniques, Two-Way Satellite Time and Frequency Transfer (TWSTFT) ensures a relatively high accuracy, with a time comparison accuracy at a nanosecond level. However, TWSTFT systems have some limitations, such as the dependency on extra network links. In this paper, we propose an improved method for TWSTFT system operation and design a message structure for the suggestion. Additionally, we estimate the data rate and redundancy for the new TWSTFT signal with the designed message structure.

구조물의 균열 진전 탐지를 위한 광섬유 브래그 격자 센서 (Fiber Optic Bragg Grating Sensor for Crack Growth Detection of Structures)

  • 권일범;서대철;김치엽;윤동진;이승석
    • 비파괴검사학회지
    • /
    • 제27권4호
    • /
    • pp.299-304
    • /
    • 2007
  • 구조물의 주요 부재들은 임의의 부분에 과대 하중이 작용하거나 반복 하중을 받아서 재료가 열화되면 균열이 발생한다. 이러한 균열은 구조물의 안전성을 평가할 수 있는 중요한 인자이며 균열의 진전 여부가 구조물의 안전성을 평가하기 위한 중요한 지표로 사용할 수 있다. 따라서 본 연구에서는 구조물의 기존 균열이 진전하는지를 감시하기 위하여 광섬유 브래그 격자 센서를 개발하였다. 이 센서 시스템은 탐촉자, 파장제어 광원부 및 광수신부, 그리고 가진부로 구성된다. 센서 탐촉자 부분은 광섬유 브래그 격자 소자만으로 구성된다. 파장제어 광원부는 전류공급회로와 DFB(distributed feedback) 레이저 다이오드로 구성되고 파장 제어 회로는 레이저 다이오드의 온도를 바꾸어 파장을 제어한다. 또한 가진부는 강체 낙하구에 의하여 구현한다. 이렇게 구성된 센서의 성능은 알루미늄판에 임의의 균열을 만들고 센서를 작동시키면서 출력 신호를 검토하면서 확인하였다. 광섬유 브래그 격자 센서의 출력 신호의 변화는 균열 길이 변화에 따라서 크게 변화되어 나타나므로 균열 진전 탐지 가능성이 충분함을 확인할 수 있었다.

Phase Jitter Analysis of Overlapped Signals for All-to-All TWSTFT Operation

  • Juhyun Lee;Ju-Ik Oh;Joon Hyo Rhee;Gyeong Won Choi;Young Kyu Lee;Jong Koo Lee;Sung-hoon Yang
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권3호
    • /
    • pp.245-255
    • /
    • 2023
  • Time comparison techniques are necessary for generating and keeping Coordinated Universal Time (UTC) and distributing standard time clocks. Global Navigation Satellite System (GNSS) Common View, GNSS All-in-View, Two-Way Satellite Time and Frequency Transfer (TWSTFT), Very Long Baseline Interferometry (VLBI), optical fiber, and Network Time Protocol (NTP) based methods have been used for time comparison. In these methods, GNSS based time comparison techniques are widely used for time synchronization in critical national infrastructures and in common areas of application such as finance, military, and wireless communication. However, GNSS-based time comparison techniques are vulnerable to jamming or interference environments and it is difficult to respond to GNSS signal disconnection according to the international situation. In response, in this paper, Code-Division Multiple Access (CDMA) based All-to-All TWSTFT operation method is proposed. A software-based simulation platform also was designed for performance analysis in multi-TWSTFT signal environments. Furthermore, code and carrier measurement jitters were calculated in multi-signal environments using the designed simulation platform. By using the technique proposed in this paper, it is anticipated that the TWSTFT-based time comparison method will be used in various fields and satisfy high-performance requirements such as those of a GNSS master station and power plant network reference station.

Measurement of Cortisol in Human Serum by Isotope Dilution Liquid Chromatography/Mass Spectrometry and a Comparison through a Proficiency Testing

  • Lee, Hwa-Shim;Shin, Hye-Sun;Park, Sang-Ryoul;Park, Chang-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1149-1154
    • /
    • 2010
  • Liquid chromatography/mass spectrometry using isotope dilution method has been established as a primary method for the measurement of cortisol in human serum. Verification of this method was accomplished by the participation in Consultative Committee for Amount of Substance-Metrology in Chemistry (CCQM) pilot study. Two levels of cortisol certified reference materials were prepared and certified by the established method. They were used as sample materials for the proficiency testing. The expanded uncertainty in the measurement of cortisol in human serum was approximately 1.2% at 95% confidence level. The results of the proficiency testing showed a good precision among the participants, but some bias to the certified values. This means that commercial field laboratories should keep traceability chain to SI unit through available reference measurement procedures and/or available reference materials.

Pipe Wall Thinning Evaluation through the Arrival Time Delay of A0 Lamb Wave Using Magnetostrictive Patch Transducers

  • Cho, Seung-Hyun;Kwon, Hyu-Sang;Ahn, Bong-Young;Lee, Seung-Seok
    • 비파괴검사학회지
    • /
    • 제28권6호
    • /
    • pp.512-518
    • /
    • 2008
  • Guided wave technology is advantageous for fast inspection of pipe wall thinning since the guided wave propagates long distance. In this investigation, the method to evaluate gradual wall thinning in a pipe based on the arrival time delay with magnetostrictive patch transducers is presented. Low frequency A0 Lamb waves were generated and measured by the present transducer and it was applied to arrival time delay measurement experiments on a test pipe having gradual wall thinnings artificially manufactured. From experiments, consistent results that wall thinning increases the arrival time delay of A0 waves were obtained. Consequently, the feasibility of the magnetostrictive patch transducers to evaluate wall thinning was verified.

압력과 온도측정 기능을 갖는 고성능 플렉시블 촉각센서 (High-Performance Multimodal Flexible Tactile Sensor Capable of Measuring Pressure and Temperature Simultaneously)

  • 장진석;강태형;송한욱;박연규;김민석
    • 한국정밀공학회지
    • /
    • 제31권8호
    • /
    • pp.683-688
    • /
    • 2014
  • This paper presents a high-performance flexible tactile sensor based on inorganic silicon flexible electronics. We created 100 nm-thick semiconducting silicon ribbons equally distributed with 1 mm spacing and $8{\times}8$ arrays to sense the pressure distribution with high-sensitivity and repeatability. The organic silicon rubber substrate was used as a spring material to achieve both of mechanical flexibility and robustness. A thin copper layer was deposited and patterned on top of the pressure sensing layer to create a flexible temperature sensing layer. The fabricated tactile sensor was tested through a series of experiments. The results showed that the tactile sensor is capable of measuring pressure and temperature simultaneously and independently with high precision.

정밀저울을 이용한 원자힘 현미경 캔티레버의 특성평가 (Atomic Force Microscope Probe Calibration by use of a Commercial Precision Balance)

  • 김민석;최인묵;박연규;최재혁;김종호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.637-640
    • /
    • 2005
  • In this paper, we investigate the characteristics of a piezoresistive AFM cantilever in the range of $0\~30{\mu}N$ by using nano force calibrator (NFC), which consists of a high precision balance with resolution of 1 nN and 1-D fine positioning stage. Brief modeling of the cantilever is presented and then, the calibration results are shown. Tests revealed a linear relationship between the probing force and sensor output (resistance change), and the force vs. deflection. From this relationship, the force constant of the cantilever was calculated to 3.45 N/m with a standard deviation of 0.01 N/m. It shows that there is a big difference between measured and nominal spring constant of 1 N/m provided by the manufacturer s specifications.

  • PDF

Gait Feature Vectors for Post-stroke Prediction using Wearable Sensor

  • Hong, Seunghee;Kim, Damee;Park, Hongkyu;Seo, Young;Hussain, Iqram;Park, Se Jin
    • 감성과학
    • /
    • 제22권3호
    • /
    • pp.55-64
    • /
    • 2019
  • Stroke is a health problem experienced by many elderly people around the world. Stroke has a devastating effect on quality of life, causing death or disability. Hemiplegia is clearly an early sign of a stroke and can be detected through patterns of body balance and gait. The goal of this study was to determine various feature vectors of foot pressure and gait parameters of patients with stroke through the use of a wearable sensor and to compare the gait parameters with those of healthy elderly people. To monitor the participants at all times, we used a simple measuring device rather than a medical device. We measured gait data of 220 healthy people older than 65 years of age and of 63 elderly patients who had experienced stroke less than 6 months earlier. The center of pressure and the acceleration during standing and gait-related tasks were recorded by a wearable insole sensor worn by the participants. Both the average acceleration and the maximum acceleration were significantly higher in the healthy participants (p < .01) than in the patients with stroke. Thus gait parameters are helpful for determining whether they are patients with stroke or normal elderly people.

Irreversible Magnetization of MgB2 Superconductor

  • Kim, Mun-Seog;Kim, Kyu-Tae;Kim, Wan-Seop;Park, Po-Gyu;Lee, Kyu-Won;Lee, Sung-Ik
    • Journal of Magnetics
    • /
    • 제10권4호
    • /
    • pp.157-162
    • /
    • 2005
  • We report the magnetic-field dependence of the irreversible magnetization of binary superconductor $MgB_2$. For the temperature region of $T\;<\;0.9T_c$, the contribution of the bulk pinning to the magnetization overwhelms that of the surface pinning. This was evident from the fact that the magnetization curves, M(H), were well described by the critical-state model without considering the reversible magnetization and the surface pinning effect. It was also found that the M(H) curves at various temperatures scaled when the field and the magnetization were normalized by the characteristic caling factors H$\ast$(T) and M$\ast$(T), respectively. This feature suggests that the pinning mechanism determining the hysteresis in M(H) is unique below $T\;=\;T_c$.