• Title/Summary/Keyword: methylmethacrylate

Search Result 102, Processing Time 0.03 seconds

Strength Properties of Polymer-Modified Mortars Using Methylmethacrylate-Ethyl Acrylate Latexes according to Amount of Emulsifier (유화제 첨가량에 따른 MMA/EA 합성 라텍스 폴리머 시멘트 모르타르의 강도특성)

  • 형원길;조영철;김완기;이대수;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.421-424
    • /
    • 2003
  • The purpose of this study is to clarify the effect of the emulsifier ratio on strength properties of the polymer-modified mortars using methylmethacrylate-ethyl acrylate(MMA/EA) latexes, and to obtain basic data necessary to develope appropriate latexes for cement modifiers. Polymer-modified mortars using MMA/EA latexes are prepared with various monomer ratios, and tested for air content, flexural and compressive strengths. From the test results, we knew that the water-cement ratio is decreased and the air content is increased with an increase in the amount of emulsifier. In general, the superior flexural and compressive strengths of polymer-modified mortars using MMA/EA latexes is obtained at a bound MMA content of 60 percent and a emulsifier ratio of 6 percent.

  • PDF

Preparation of Properties of PC/PBT Alloy Using MBS Compatibility (MBS상용화제를 사용한 PC/PET Alloy의 제조와 그 물성)

  • Lee, Yong-Moo;Kang, Doo-Whan
    • Applied Chemistry for Engineering
    • /
    • v.5 no.1
    • /
    • pp.54-62
    • /
    • 1994
  • Bisphenol A polycarbonate(PC) and polyethylene terephthalate(PET) was blended with methylmethacrylate-butadiene-styrene(MBS) copolymer for the improvement of impact resistance strength PC/PET alloy blending with PC more than 15 parts to 100 parts of PET usually have poor compatability, but increased the compatability characteristics of PC/PET alloy prepared by addition of MBS compatabilizer. The compatability of PC and PET using compatabilizer, MBS was determined by measuring the thermal characteristics of Tg difference between PC and PET, and crystallization temperature, Tcc. As the Tg difference becoming narrow to $60^{\circ}C$, and Tcc decreasing to $150^{\circ}C$, the comparability of PC and PET was increased. And also tough rate impact strength to PC/PET alloy using MBS was increased, in case more than 15 parts of PC being blended to PET.

  • PDF

Solvent-assisted sealing of poly(methylmethacrylate) microchannel under mild conditions (용매를 이용한 Poly(methylmethacrylate)의 저온 저압 본딩 및 마이크로 채널 표면의 선택적 소수성 코팅기법 개발)

  • Lee, Jae-Seon;Lee, Nae-Yun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.110-110
    • /
    • 2017
  • 마이크로 플루이딕 디바이스는 화학, 생물학 실험 및 생체 의학 진단을 위한 플랫폼으로 지난 20년간 그 사용 및 연구가 증가되어 왔다. 마이크로 플루이딕 디바이스를 제작하는 데 있어 가장 일반적으로 사용되는 재료는 실리콘이지만 비용이 많이 들고 불투명하므로 광학 검출이 필요한 곳에 적용이 제한된다. 이러한 측면에서 열가소성 플라스틱은 상업화의 중요한 요소인 대량 생산에 있어 큰 잠재력을 가지고 있으며 저렴하고, 가공이 쉽고, 유연하고, 광학적으로 투명하고, 화학적으로 불활성이며, 생체적합성을 가진다. 본 연구에서는 열가소성 플라스틱의 일종인 PMMA Poly(methylmethacrylate)를 효율적으로 접합하기 위해 비교적 낮은 온도와 낮은 압력에서 에탄올을 활용한 접착방식을 개발하였다. 먼저, PMMA 기판의 전체 표면을 $80^{\circ}C$에서 20 분 동안 에탄올로 처리한 후, $60^{\circ}C$에서 20 분간 열 압착하는 방식으로 영구적인 결합이 이루어졌다. 결합 강도 및 채널의 sealing 정도를 확인하기 위해, 인장 강도, 누수 및 파열 테스트를 수행하였다. 결합강도는 약 12.4 MPa로 타 연구와 비교할 때 매우 높았으며 마이크로 채널의 전체 내부 체적보다 거의 450 배 높은 강한 액체 흐름을 견딜 정도로 견고한 결합이 유지되었다. 열가소성 플라스틱의 본딩에 사용되는 유기 용매는 광학 특성을 희생시키지 않으면서 결합 속도를 높일 수 있지만, 결합 공정 중에 용매로 인해 마이크로 채널이 막히는 현상이 발생될 수 있다. 따라서, 견고한 본딩을 유지하면서 채널 막힘을 방지하기 위해 마이크로 채널을 소수성으로 선택적으로 처리하여 내벽의 표면 특성을 튜닝해 주는 기법을 추가로 적용하였다. 본 연구에서 사용한 방법은 아민-PDMS (polydimethylsiloxane) 링커를 적용하여 기판 표면의 극성을 변경시켜 주었다. 아민-PDMS 링커는 PC (polycarbonate), PET (polyethylene terephthalate), PVC (polyvinyl chloride) 및 PI (polyimide)와 같은 다양한 열가소성 플라스틱의 표면 소수성을 현저히 증가시키며 화학적, 열적 안정성이 뛰어나다. 아민-PDMS 링커는 PMMA의 카보닐 그룹과 반응할 수 있는 아민 사이드 그룹을 포함하는 PDMS 백본으로 구성되며 처리된 대상표면을 소수성으로 만든다. 아민-PDMS 링커 처리 이후 채널은 소수성으로 변화되었으며 이는 접촉각(contact angle)의 증가로 확인되었다. 코팅된 채널을 에탄올로 30분간 80도에서 처리하여도 소수성은 그대로 유지되어 마이크로 채널의 선택적인 소수성 코팅이 성공적으로 수행되었다.

  • PDF

Nano-scale pattern delineation by fabrication of electron-optical lens for micro E-beam system (마이크로 전자빔 시스템을 위한 전자광학렌즈의 제작에 의한 나노 패턴 형성)

  • Lee, Yong-Jae;Park, Jung-Yeong;Chun, Kuk-Jin;Kuk, Young
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.9
    • /
    • pp.42-47
    • /
    • 1998
  • We have fabricated electron-optical lens for micro E-beam system that can overcome the limitation of current E-beam lithography. Our electron-optical lens consists of multiple silicon electrodes which were fabricated by micromachining technology and assembled by anodic bonding. The assembled system was installed in UHV chamber to observe the emission characteristics of focused electrons by the electro-optical lens. We used STM(Scanning Tunneling Microscope) tip for electron source. By performing lithography with the focused electrons with PMMA(poly-methylmethacrylate) as E-beam resist. We could draw 0.13${\mu}{\textrm}{m}$ nano-scale lines.

  • PDF

A Study on the Transesterification Reaction Between Methyl Methacylate and Diethanolamine (메틸메타크릴레이트와 디에탄올아민과의 에스테르 교환반응에 관한 연구)

  • Sohn, Byoung-Chung;Park, Keun-Ho;Jeong, Soon-Wook;Nam, Ki-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.41-47
    • /
    • 1986
  • The transesterification reaction between diethanolamine and methyl-methacrylate was kinetically investigated in the presence of various metal acetate catalysts at $120^{\circ}C$. The quantity of methylmethacrylate reacted in the reaction flask was measured by gas chromatography and liquid chromatography, and the reaction rate was investigated by measuring of the quantity of products and reactnts under various catalysts. The transesterification reaction was carried out in the first order reaction kinetics with respect to the concentration of diethanolamine and methylmethacrylate, respectively. The apparent rate constant was found to obey first-order kinetics with respect to the concentration of catalyst. The linear relationship was shown between apparent rate constant and reciprocal absolute temperature, and by the Arrhenius plot, the activation energy has been calculated as 11.08 Kcal with zinc acetate catalyst, 17.99 Kcal without catalyst. The maximum reaction rate was appeared at the range of 1.4 to 1.6 of electronegativity of metal ions and instability constant of metal acetates.

Study on the Preparation and Properties of Polyurethane-Acryl Emulsion Resin (폴리우레탄-아크릴 에멀젼 수지 제조 및 물성에 관한 연구)

  • Kim, Hong-Tae;Lee, Myung-Cheon
    • Applied Chemistry for Engineering
    • /
    • v.16 no.1
    • /
    • pp.39-44
    • /
    • 2005
  • In this study, polyurethane-acryl emulsion resins were synthesized from HDI (hexamethylene diisocyanate), IPDI (isophorone diisocyanate), Polyol, 2-HEMA (2-hydroxy ethylmethacrylate), n-BA (n-butyl acrylate) and MMA (methylmethacrylate). The effects of polyol types on the properties of polyurethane-acryl emulsion resin, such as degree of strength and water resistance and on the manufacturing process were investigated. In addition, the results were compared with those of acrylic emulsion. The test results showed that polyester type polyol demonstrated stronger tensile strength and higher water resistance with time than did acrylic emulsion and polyether type polyol.

Metastasising Recurrent Giant Cell Tumor - A Case Report - (폐 전이를 일으킨 재발성 거대세포종 - 증례 보고 -)

  • Kim, Tae-Seung;Park, Jun-Sic
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.2
    • /
    • pp.73-79
    • /
    • 2001
  • Giant cell tumor is usually found around the knee joint, especially in the distal femur or proximal tibia. Despite being classified as benign, it has unusual biological behavior of local aggressiveness and tend to have severely destructive lesion and develop rare pulmonary metastasis. Therefore, when the patient is presented to the physician with an expansile lytic lesion of challenging clinicopathologic entity extending to subchondral bone, the physician faces up to difficulties in treatment. We report a case of 25 years old patient having recurrent giant cell tumor in the right distal femur which developed metastasis to lung. The primary bone lesion was treated with local curettage and fillings with methylmethacrylate, but when he returned to the hospital two years later, the recurrence had developed with lung metastasis.

  • PDF

Novel Macromonomer as a Reactive Stabilizer in the Dispersion Polymerization of Methylmethacrylate

  • Jung, Hye-Jun;Lee, Kang-Seok;Shim, Sang-Eun;Yang, Sun-Hye;Lee, Jung-Min;Lee, Hui-Je;Choe, Soon-Ja
    • Macromolecular Research
    • /
    • v.12 no.5
    • /
    • pp.512-518
    • /
    • 2004
  • We have synthesized a novel macromonomer of vinyl-terminated bifunctional polyurethane having a molecular weight of 37,000 g/mol and successfully applied it to the dispersion polymerization of methylmethacrylate(MMA). We verified the presence of the vinyl terminal group and the macromonomer grafted onto the poly(ethylene glycol)(PEG) block in the PMMA particles by using $^1$H and $\^$13/C NMR spectroscopies. Monodisperse PMMA microspheres that have good uniformity of 1.01 were prepared at 20 wt% macromonomer content; we investigated the characteristics of the PMMA particles in terms of their molecular weight, molecular weight distribution, size of the particles, thermal properties, and glass transition temperature. We have found that the synthesized polyurethane macromonomer is an effective stabilizer.

A Study on the Preparation and Resist Characterization of the Plasma Polymerized Thin Films (플라즈마중합막의제작과레지스트 특성에 관한 연구)

  • 이덕출;박종관;한상옥;김종석;조성욱
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.5
    • /
    • pp.802-808
    • /
    • 1994
  • The purpose of this paper is to describe an application of plasma polymerized thin film as an electron beam resist. Plasma polymerized thin film was prepared using an interelectrode capacitively coupled gas-flow-type reactor, and chosen methylmethacrylate(MMA)and methylmethacrylate-tetrameth-yltin(MMA-TMT) as a monomer. This thin films were also delineated by the electron-beam apparatus with an acceleration voltage of 30kV and an expose dose ranging from 20 to 900$\mu$C/cmS02T. The delineated pattern in the resist was developed with the same reactor which is used for polymerization using an argon as etching gas. The growth rate and etching rate of the thin film is increased with increasing of discharge power. Thin films by plasma polymerization show polymerization rate of 30~45($\pm$3) A/min, and etching rate of 440($\pm$30) A/min during Ar plasma etching at discharge power of 100W. In apparently lower than that of conventional PMMA, but the plasma-etching rate of PP(MMA-TMT) was higher than that of PPMMA.

  • PDF

Treatment of Giant Cell Tumor Around Knee - by Intralesional Excision Using High Speed Burr and Methylmethacrylate - (슬관절 주변에 발생한 거대세포종의 치료 - 고속 바(High-Speed Burr)와 골 시멘트를 이용한 병소 내 절제술 -)

  • Park, Jong-Hoon;Lee, Soo-Yong;Jeon, Dae-Geun;Cho, Wan-Hyung;Song, Won-Seok;Kim, Jin-Wook;Koh, Han-Sang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.2
    • /
    • pp.160-167
    • /
    • 2005
  • Purpose : Distal femur and proximal tibia are the common sites affected by giant cell tumor of bone. There are a variety of treatment modality including wide excision and intralesional curettage. We evaluated the local recurrence rates and the post-operative functional scores of giant cell tumors around knee joint and investigated the identification of possible prognostic factors for recurrence. Materials and Methods: We reviewed 41 patients pathologically confirmed as giant cell tumors around knee joint that have undergone intralesional curettage using high-speed burr and methylmethacrylate. We evaluated the recurrence rate and post-surgical functional score and possible prognostic factors for recurrence, such as, gender, age, tumor location, size, subchondral invasion, intra-articular invasion and the Campanacci Grades. Mean follow up period was 50 (12-122) months. Results: The recurrence rate was 17% and mean recurrence onset was 10 months postoperatively. According to Musculoskeletal Tumor Society (MSTS) functional evaluation system, the average score was 27.8(93%) and 78% had excellent function. According to our study, suspected prognostic factors revealed not significant for recurrence. Conclusion: We found no significant recurrence related factors. Intralesional excision with high-sped burring and PMMA provides a low recurrence rate, similar to others in the literature, and good functional scores.

  • PDF