• Title/Summary/Keyword: methylene-blue

Search Result 886, Processing Time 0.023 seconds

Effects of Hwadamtongrak-Tang on the changes of Cerebral Flow in the rats (화담통락탕(化痰通絡湯)이 백서의 뇌혈류변화 및 허혈성 뇌손상에 미치는 영향)

  • Park, Hyoung-Bae;Yang, Seung-Jung;Wei, Tung-Sheun;Park, Hye-Sun;Jeon, Sang-Yoon;Hong, Seok
    • Herbal Formula Science
    • /
    • v.14 no.1
    • /
    • pp.105-119
    • /
    • 2006
  • Objectives & Methods : This present study was performed to investigate the effect of Hwadamtongrak-Tang extract (HTT) on the regulation of cerebral hemodynamics in terms of regional cerebral blood flow (rCBF) and mean arterial blood pressure (MABP)] in normal and cerebral ischemic rats. Also the effects of HTT on changes in local blood flow, inhibition of LD H activity in neuronal cells, and levels of cytokine production in the serum were determined in the ischemic rat model. The major findings are summarized below. Results : 1. HTT significantly increased rCBF in a dose-dependent manner, but MABP was not changed by HTT treatment. These results suggest that HTT may increase rCBF by dilating cerebral arterial diameter. 2. HTT-induced increase in rCBF was blocked by pretreatment with cyclooxygenase inhibitor indomethacin (IDN, 1 mg/kg, i.p.) and MABP was significantly increased by ID N. 3. Pretreatment of methylene blue $(MTB,\;10\;{\mu}g/kg,\;i.p.)$, an inhibitor of guanylate cyclase, significantly decreased both rCBP and MABP in HTT-treated rats. 4. HTT treatment significantly increased rCBP to a stable level during the period of cerebral reperfusion. 5. HTT significantly inhibited LD H activity in neuronal cells, suggesting a neuroprotection by HTT. 6. Serum interleukin $(IL)-1{\beta}$ and tumor necrosis factor $(TNF)-{\alpha}$ levels were significantly decreased in the femoral artery 1 hr after middle cerebral arterial occlusion in HTT-treated rats. IL-10 levels in the serum were significantly increased by HTT treatment whereas transforming growth factor $(TGF)-{\beta}$ levels were similar between HTT-treated and control groups. 7. Serum interleukin $(IL)-1{\beta}$ and tumor necrosis factor $(TNF)-{\alpha}$ levels were significantly decreased in the femoral artery 1 hr after reperfusion in HTT-treated rats. Serum IL-10 levels were significantly decreased in HTT-treated rats compared with the control group, and no significant changes in $(TGF)-{\beta}$ in the serum were observed by HTT treatment. Conclusions: The present data suggest that HTT may have an anti-ischemic effect via the improvement of cerebral hemodynamics and thus protect the brain from ischemic damage.

  • PDF

The Effects of Forsythiae Fructus n-BuOH Fraction on Atopic Dermatitis (연교(連翹) n-BuOH 분획물의 아토피 피부염 억제 효과)

  • Lee, Jin Hwa;Han, Jae Kyung;Kim, Yun Hee
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.30 no.3
    • /
    • pp.1-30
    • /
    • 2016
  • Objectives Previous studies have found out that Forsythiae Fructus (FF) extracts have anti-atopic activities by in vitro experiment. In order to understand more about FF extracts' benefit, we subdivided FF extracts depending on systematic fractionation method by using Methylene chloride (MC), Ethyl acetate (EtOAc), n-BuOH and n-hexane (n-Hx). This study is designed to examine the effect of FF fractions on the PMA- ionomycin-induced activation of RBL-2H3 mast cell lines in vitro and on the DNCB-induced activation of NC/Nga mice in vivo. Methods For this study, we examined IL-4, IL-13 production by ELISA analysis, IL-4, IL-13, IL-31, IL-31RA and TNF-${\alpha}$ mRNA expression by real-time PCR and manifestations of AP-1 and MAPKs transcription factors by western blotting in vitro. Through in vitro experiment, we selected FF n-BuOH fraction that seems the best effective in atopic dermatitis then induced it on NC/Nga mice by DNCB. We measured mice's WBC, eosinophil and neutrophil in heart blood, IL-4, IL-5, IFN-${\gamma}$ in the spleenocyte culture supernatant, the absolute cell numbers of CD4+, CD8+, B220+CD23+, CD3+CD69+ and Gr-1+CD11b+ in the PBMCs, ALN and dorsal skin, IL-5, IL-13, IL-31, IL-31RA in the dorsal skin by real-time PCR and the distribution of immune cells by H&E on dorsal skin and ANL and toluidine blue staining on dorsal skin. Results FF n-BuOH fraction suppressed IL-4, IL-13 production and mRNA expression of IL-4, IL-13, IL-31, IL-31RA and TNF-${\alpha}$. Results from the western blot analysis showed that FF n-BuOH fraction reduced the activation of the mast cell specific transduction factors involved in AP-1 by suppressing JNK and ERK phosphorylation. In the gross, atopic dermatitis induced by DNCB in NC/Nga mice were improved by oral administration of FF n-BuOH fraction. Oral FF n-BuOH fraction also decreased the level of IgE in mice's serum and the level of IL-4 and IL-5 in the spleenocyte culture supernatant, cell numbers of CD8+, B220+CD23+ in the PBMCs, CD4+ in the ALN and CD4+, Gr-1+CD11b+ in the dorsal skin and suppressed mRNA expression of IL-5, IL-13, IL-31, IL-31RA in the dorsal skin. Histological examination showed that infiltration levels of immune cells in atopic dermatitis induced NC/Nga mice were improved by FF n-BuOH fraction. Conclusions FF n-BuOH fraction can reduce pruritus by suppressing IL-31, IL-31RA secretion and modulate molecular mediators and immune cells associated with atopic dermatitis induced in NC/Nga mice which may have played a significant role in recovering atopic dermatitis symptoms.

IN VITRO STUDY ON APICAL SEAL AND SEM MORPHOLOGY IN CANALS FILLED WITH RESIN-BASED ROOT CANAL SEALER AND SELF-ETCHING PRIMER (SELF-ETCHING PRIMER와 레진계 근관 SEALER 사용시 근관벽의 형태와 치근단 근관밀폐에 대한 실험적 연구)

  • Kang, Sam-Hee;Park, Dong-Sung;You, Heyon-Mee;Oh, Tae-Seok
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.543-549
    • /
    • 2000
  • Gutta-percha와 근관sealer를 사용한 근관 충전은 가장 많이 이용되고 성공률이 높은 방법이지만, 현재 사용되는 모든 근관sealer는 미세누출을 나타낸다. 따라서 더 효과적인 근관 폐쇄를 이루기 위한 재료 및 방법들이 연구되어왔다. 이중 상아질 접착제는 근관 충전재와 함께 사용되어 미세누출을 감소시키지만, 근관 내에 사용하기에 술식이 복잡하고 기술이 요구된다. 본 연구의 목적은 gutta-percha와 레진계 근관 sealer로 충전한 근관에서 self-etching primer를 미리 도포한 경우와 도포하지 않은 경우의 치근단 미세누출을 비교하고, self-etching primer를 도포함에 있어 근관 내에 적용하는 방법에 따른 미세누출을 비교하는 것이다. 또한 근관sealer와 상아질 계면을 주사전자현미경으로 관찰하여, 이 결과를 미세누출과 관련시켜보고자 하였다. 36개의 발거된 사람의 단근치에서 치관부를 절단, 제거하고 ProFile로 근관 형성한 후, 무작위로 선택하여 4개의 군으로 분류하였다. 1군에서는 주사기와 30게이지 주사 바늘로 self-etching primer를 근관 내에 적용하였고, 2군에서는 self-etching primer를 paper point에 적셔 근관 내에 적용하였다. 3군에서는 self-etching primer를 적용하지 않았다. 1, 2, 3군의 치아를 gutta-percha와 AH26 sealer를 사용하여 continuous wave 충전법으로 충전한 후 치근단공 주위 3mm를 제외한 치근변에 nail polish를 2회 도포하였고, 4군(음성 대조군)은 치근면 전체에 도포하였다. 1군과 2군에서 각각 2개의 치아는 주사전자현미경적 관찰을 위해 준비하였다. 모든 치아를 Methylene Blue 수용액에 48시간동안 침적, 수세한 후 치아 장축에 평행하게 양분하여 10배의 실물확대현미경 하에서 치근단 색소 침투를 관찰하였다. Self-etching primer를 도포한 군과 도포하지 않은 군 사이에는 평균 미세누출량에 유의한 차이가 없었다. 주사 바늘로 적용한 군과 paper point로 적용한 군 사이에도 평균 미세누출량에 유의한 차이가 없었다. 상아질과 근관 sealer계면의 주사전자현미경 관찰 결과 일부분에서 긴밀한 접착 관계를 나타내었고, 다른 부분에서는 간극을 나타내었다.

  • PDF

THE INFLUENCE OF OBTURATION TIMING AND THICKNESS OF MINERAL TRIOXIDE AGGREGATE ON SEALING ABILITY OF CANAL WITH OPEN APEX (근관충전 시기와 MINERAL TRIOXIDE AGGREGATE의 APICAL MATRIX두께에 따른 치근단 밀폐도의 평가)

  • Kwak, Kyung-In;Park, Dong-Sung;Yoo, Hyeon-Mee;Oh, Tae-Seok
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.536-542
    • /
    • 2000
  • 임상에서 점차 Mineral Trioxide Aggregate (MTA)에 대한 우수성이 소개되면서, apical matrix로의 사용은 주목할 만하다 할 수 있다. 본 연구의 목적은 개방형근관에서 MTA가 apical matrix로 사용될 때의 치근단 밀폐효과를 알아 보고, 근관충전의 시기와 matrix의 두께가 치근단 밀폐에 미치는 영향을 치근단 미세누출의 측면과 matrix탈락빈도의 측면에서 관찰하고자 하는 것이다. 개방형 근관을 재현하고자 45개의 발거된 단근치에 #90크기로 근단공을 형성하였고, 투명레진등을 이용하여 치근단 병소를 갖는 치조골을 재현한 후, 4개의 실험 군과 1개의 대조 군으로 분류하였다. A군: 2mm두께의 MTA matrix 형성후, 열연화된 Gutta-percha와 AH26 sealer를 이용하여 즉시 근관충전. B군: 2mm 두께의 MTA matrix 형성후, A군과 같은 방법으로 24시간 후 근관충전. C군: 4mm 두께의 MTA matrix 형성후, A군과 같은 방법으로 즉시 근관충전. D군: 4mm 두께의 MTA matrix 형성후, A군과 같은 방법으로 24시간 후 근관충전. 대조군: matrix를 사용하지 않고 열연화된 Gutta-percha와 AH26 sealer를 이용하여 근관충전하였다. Matrix의 탈락이 있는 경우 기록하고 완전 수세 후 다시 시행하였다. 색소침투정도의 평가를 위해 methylene blue에 치아를 48시간 침수시킨 후 협설로 양분하였다. 각 시편들을 고배율 현미경 관찰 후 비디오촬영 하였고, digitalized image analysing program을 이용하여 두명의 관찰자가 누출의 정도를 평가한 후, One-way ANOVA로 통계적 유의성을 검증하여 다음과 같은 결과를 얻었다. 1. Matrix를 사용한 실험 군이 matrix를 사용하지 않은 대조 군에 비해 유의성 있게 낮은 누출을 보였다(p<0.05). 그러나 근관충전시기와 matrix의 두께를 달리한 실험군 내에서는 누출에 유의성 있는 차이가 나타나지 않았다. 2. 모든 실험군에서 gutta-percha를 이용한 근관충전의 시기에 matrix탈락 및 gutta-percha의 압출은 발생하지 않았다.

  • PDF

EFFECTS OF SMEAR LAYER AND DENTIN PRIMERS ON THE SEALING ABILITY OF ROOT CANAL (근관 밀폐도에 미치는 도말층 및 상아질 접착강화제의 영향)

  • Yang, Jin-Suck;Hwang, In-Nam;Kim, Won-Jae;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.527-535
    • /
    • 2000
  • The purpose of this study was to evaluate effects of smear layer and dentin primers on the sealing ability of root canals. 126 extracted human teeth with single, straight canals and mature apices were used. The Samples were first classified into six groups as follows: presence of smear layer; absence of smear layer; Scotchbond Bond Multi-Purpose; All Bond 2; Mac Bond 2; Clearfil Liner Bond 2. A Positive control was also established. All teeth except the control group were then obturated with thermoplasticized gutta-percha and AH26. Electrochemical and dye penetration technique were later used to evaluate the degree of micro leakage through the root canal. Seventy teeth were then immersed in a 1% potassium chloride solution and An external power supply(DC 10 V) was then applied to the circuit for the electrochemical microleakage test. The degree of Microleakage was determined over period of 28 days before being evaluated. In total, 48 teeth were submitted to the dye infiltration technique. All specimen were suspended in 2% methylene blue dye for 1 week before being longitudinally split. The degree of dye infiltration was measured under a stereo microscope at ${\times}10$ magnification and evaluated. The results were as follows: 1. Apical microleakage increased throughout the test period in all group and one group having a smear layer showed a dramatic increase under electrochemical test (p<0.05). In the group having smear layer, the degree of apical microleakage was the highest, and the micro leakage was much higher than in the smear layer removed group in electrochemical test (p<0.05). Scotchbond Multi-Purpose, All Bond 2, Mac Bond 2 and Clearfil Liner Bond 2 showed lower micro leakage than one group having smear layer. The All Bond 2 and Clearfil Liner Bond 2 treated groups showed the lowest microleakage in electrochemical test (p<0.05). 2. There was no significant difference between the experimental groups in dye penetration technique. These results suggested that the removal of the smear layer from root canal and concomitantly the application of dentin primer into root canal could improve the sealing ability of root canal obturation.

  • PDF

A STUDY ON THE EFFECT OF BASE MATERIALS TO PROTECT THE CERVICAL LEAKAGE OF BLEACHING AGENTS (표백제의 치경부 누출을 방지하기 위한 각종 이장재의 효과에 관한 연구)

  • Song, Byeong-Choon;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.585-601
    • /
    • 1994
  • The purpose of this study was to evaluate the ability of several intracoronal base materials to prevent cervical leakage of a bleaching agent into the dentinal tubules and along the root canal. In this study, thirty-two anterior teeth were used. After lingual access was prepared in each tooth, tooth was instrumented with a step-back technique to a Nos. 40-50 using K-type files. All teeth were obturated with a lateral condensation technique. Excess gutta percha was removed with a warm instrument to the facial level of the CEJ. Teeth were divided into four groups : Teeth in control group were not filled with base material. Teeth in groups 1, 2, and 3 had 2mm of gutta percha removed with a warm instrument, then Dycal, Fuki II LC and Z-100 were filled with palstic instruments on the top of the gutta percha respectively. All teeth were bleached for 7 days, fresh bleach was added for another 7 days, then a 10 % methylene blue dye was placed inside the access preparation. They were stored at $37^{\circ}C$ and $100^{\circ}C$ humidity for 5 days. Each tooth was sectioned perpendicular to the long axis using a diamond disk. Initial cuts were made at the most coronal level of facial and lingual CEJ's, then another cuts continued appically in the levels of 0.5mm, 1.5mm, and 2.0mm respectively. The amount of dye leakage through the dentinal tubules was determined at each cut section. In addition, when the cut specimen was determined to be last penetration of any dye, this level was recorded as depth of apical leakage from the coronal terminus of the gutta percha, Dycal, Fuji II LC and Z-100. The acquired data were analyzed by Tukey's Multiple Range Test adn Cochran-Mantel-Haenszel Test to see if there was any statistically significant difference in dye penetration and linear apical leakage among the groups. The results were as follows : 1. Control group at levels of CEJ and 0.5mm, group 3 at level of 1.5mm, and group 2 AND 3 at level of 2.0mm showed the least dye penetration through the facial or lingual dentinal tubules, but there were no significant difference among three groups. 2. Group 2 at levels of CEJ and 0.5mm, group 3 at level of 1.5mm, and group 2 and 3 at level of 2.0mm showed the least dye penetration through the proximal dentinal tubules, but there were no significant difference among control group, group 2, and group 3. 3. Group 1 showed the greatest dye penetration through the facial or lingual and proximal dentinal tubules at all levels, and there were significant difference with other three groups. 4. Control group and group 1 showed 2mm apical dye leakage at facial or lingual and proximal aspects, group 2 showed 1.5mm, and group 3 showed 0.5mm.

  • PDF

COMPARISON OF CANAL SHAPING METHODS WITH GTTM ROTARY FILE AND CONDENSATION METHODS (GT rotary file을 이용한 근관성형법과 충전방법의 비교)

  • Kang, Yu-Mi;Jin, Jeong-Hee;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.521-529
    • /
    • 2002
  • The purpose of this study was to compare the shaping time of two shaping methods and the leakage of three different obturation techniques. Ninty three canaled human molar teeth were used, which were randomly divided into two groups of forty teeth each and ten control teeth. After working length determination, the one group was prepared crown-down technique using rotary root canal instruments of GT rotary files .12/20, .10/20, .08/20 and .06/20 taper(Maillefer Instrument SA. Switzerland). The other group was instrumented with Gates Glidden burs(#1, #2, and #3) to coronal preparation and GT rotary files .08/20 and .06/30 taper to apical preparation. Shaping time was measured. After root canals were instrumented, they were divided to three subgroups and obturated as follows : Subgroup 1, obturated with single cone method Subgroup 2, obturated with lateral condensation : Subgroup 3, obturated with continuous wave technique. Three subgroups were obturated using non-standardized gutta-percha cone(Diadent, Korea, .06 or .08 taper) and AH-26(Dentsply DeTrey, Germany) as a root canal cement. Ten unobturated teeth served as positive and negative controls. After immersion in 2% methylene blue solution for 1 month, the teeth were washed during 24h. The teeth were demineralized in 10% nitric acid and dehydrated by immersion in 80, 90 and 100% ethyl alcohol. The teeth were finally cleared and stored in 100% methylsalicylate, and apical dye penetration was evaluated under stereomicroscope(Leica M420, LC, U.S.A)at $\times$8.75 magnification. Liner measurement of dye penetration was assessed with the use of digitalized image analysing system (analySIS, GmbH, Germany) The data were analysed statistically using independent T-test and Two-way ANOVA and Tukey test. The result were as follows 1. In canal prepared with GT$^{TM}$ rotary file, shaphing time taked more than the group of using Gates Glidden drill to coronal preparation without statistical significance (p>0.05) 2. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files showed significantly more apical leakage than those of lateral condensation and continuous wave technique regardless of shaping method (p<0.05). 3 The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed significantly more apical leakage than those of continuous wave technique regardless of shaping method (p<0.05). 4. Regardless of shaping method, The group of continuous wave obturation showed less apical leakage than those of lateral condensation without statistical significance (p>0.05). 5. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed more apical leakage than the group of lateral condensation using same shaping method with-out statistical significance (p>0.05).

MICROLEAKAGE AND MARGINAL HYBRID LAYER OF DENTIN ADHESIVES (상아질 접착제의 미세누출과 변연부 혼화층)

  • Cho, Young-Gon;Kim, Young-Kwan;Ahn, Jong-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.34-43
    • /
    • 2002
  • The purpose of this study was to compare microleakage and marginal hybrid layer in class V restorations using two one-bottle adhesives and one self-etching adhesive. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were pre-pared on buccal and lingual surfaces of 30 extracted human molar teeth. Prepared teeth were randomly divided into three treatment groups (n=30) and restored with three adhesives and composites: Single Bond/Filtek Z-250 (Group 1), Prime&BondNT/Esthet.X (Group 2), UniFil Bond/UniFil F (Group 3). For microleakage, samples were stored in room temperature water for 24 hours, thermocycled stained with 2% methylene blue dye, sectioned into halves, scored and analysed using Mann-whitney test and Wilcoxon signed rank sum test. For marginal hybrid layer, samples were sectioned into halves, treated with 10% phosphoric acid for 5 seconds, stored in 5% NaOCL solution for 24 hours, dried and gold coated. Occlusal and gingival margins of each sample were inspected under SEM. The results of this study were as follows ; 1. Microleakage at the occlusal margins was not evident in group 1 and group 2, but it showed in group 3 (p<0.05). 2. Microleakage in group 1 and group 3 was significantly lower than in group 2 at gingival margins (p<0.05). 3. Microleakage at gingival margins was greater than at occlusal margins in group 1 and group 2, but microleakage at occlusal margins was greater than at gingival margins in group 3 (p<0.05). 4. In group 1 and group 2, no gaps at occlusal margins showed. But gaps showed in group 3. Occlusal margins were free from a hybrid layer in all groups 5. The thickness of the marginal hybrid layers was 2.5~5 $\mu\textrm{m}$ thick in group 5 $\mu\textrm{m}$ thick in group 2 and 1.5 $\mu\textrm{m}$ thick in group 3. 6 There was no corelation between microleakage and thickness of marginal hybrid layer. In coclusion, the effect of dentin adhesives on microleakge in class V composite restorations was excellent when one-bottle adhesives were applied on enamel margin, and it was good when a self-etching adhesive was applied on dentinal margin. There was no corelation between microleakage and thickness of marginal hybrid layer.

MARGINAL MICROLEAKAGE OF SELF-ETCHING PRIMER ADHESIVES AND A SELF-ETCHING ADHESIVE (자가 산부식 프라이머와 자가 산부식 접착제의 변연 미세누출)

  • Cho, Young-Gon;Cho, Kong-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.493-501
    • /
    • 2002
  • This study evaluated the microleakage performance of four self-etcing primer adhesives(Clearfil SE Bond, Clearfil Liner Bond 2, UniFil Bond, and FL Bond) and one self-etching adhesive(Prompt L-Pop). Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of 50 extracted human molar teeth. Prepared teeth were randomly divided into five groups and restored using one of five adhesives and composite resins: Prompt L-Pop/Filtek Z 250(Group 1), Clearfil SE Bond/Clearfil AP-X(Group 2), Clearfil Liner Bond 2/Clearfil AP-X(Group 3), UniFil Bond/UniFil F(Group 4), and FL Bond/Filtek Z 250(Group 5). Following one day storage in room temperature water, the restored teeth were thermocycled for 500 cycles between 5$^{\circ}C$ and 55$^{\circ}C$. Marginal microleakage was assessed by dye penetration using 2% methylene blue dye. After 24 hours, the teeth were sectioned longitudinally and evaluated for microleakage under steromicroscope The data were statistically analysed by Kruskal-Wallis Test, Mann-Whitney and Wilcoxon signed ranked tests. The results of this study were as follows ; 1. The microleakges at both enamel and dentinal mal$.$gins were the lowest in group 4. increasing among groups in the following order: group 2, follwed by group 5, follwed by group 1, and the highest in group 3. 2. At the enamel margins, the microleakage of group 3 was significantly higher than those of groups 2. 4 and 5(p<0.05), and also the microleakage of group 1 was statistically higher than those of groups 2 and 5(p<0.05). 3. At the dentinal margins, microleakage of group 3 was signincantly higher than microleakages of groups 1, 2, 4 and 5(p<0.05). 4. Compared with microleakages between the enamel and dentinal margins of each group, groups 1, 4 and 5 at enamel margin and group 2 and group 3 at dentinal margin were higher microleakage. But there was no significant difference between enamel and dentinal microleakages of each group(p>0.05).

THE EFFECT OF SANDWICH TECHNIQUE USING FLOWABLE COMPOSITE RESIN BASE ON THE MICROLEAKAGEIN CLASS II CAVITIES OF MOLAR (구치부 제2급 와동에서 고흐름성 복합레진을 이용한 적층 충전술식의 미세누출에 미치는 영향)

  • Lee, Kang;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.502-514
    • /
    • 2002
  • The aim of this study was to evaluate the marginal adaptation of direct class II sandwich restoration with packable composites(P-60), resin modified glass ionomer cement(Fuji-II LC), flowable compomer(Dyract Flow), flowable composites(Filtek Flow) in comparison with total bond restorations. In addition, for sandwich restorations, influence of different sandwich techniques was also evaluated. Large butt-joint box typed class II cavites with cervical margins 1mm below the cemento-enamel junction were cut into 70 extracted human molars. The cavities(7 groups, n=10) were filled using a closed/open sandwich restoration or total bond restoration technique with materials according to the manufacturer's recommandation using the single-component bonding agent for each system. Teeth were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 30-second dwell time. The teeth were then coated with nail polish 1mm short of the restoration, placed in a 2% methylene blue for 24 hours, and sectioned with diamond wheel. Sections were examined with a stereoscope to determine the extent of microleakage. Dentine /Cementum margins were analyzed for microleakage on scale of 0(no leakage) to 4(entire axial wall) and interface between materials, on scale of 0(no leakage) to 3(axial wall). Results were evaluated with Kruskal Wallis Test, corrected for ties, to determine whether there were statistically significant differences among the seven groups. Pairs of groups were analyzed using the Student-Newman-Keuls Method and Dunn s Method. The results were as follows : 1. All groups showed some micoleakage in cervical portion. But there were no microleakage in interface between materials. 2. Closed sandwich restorations with Fuji-II LC and Filtek Flow had significantly lower leakage rating than total restorations with only P-60. However, open sandwich restorations with Dyract Flow showed significantly higher (P<0.05) 3. Closed sandwich restorations had significantly lower leakage rating than total restorations. However open sandwich restoration s showed significantly higher (P<0.05). 4. Sandwich restorations with Fuji-II LC were iou$.$or leakage than only P-60. Filtek Flow, Dyract Flow. But there were no statistically differences among the materials. From the results above, it could be concluded, closed sandwich restorations was effective in reducing microleakage of class II restorations. The best results showing the least microleakage were for the closed sandwich technique with Fuji-II LC and Filtek Flow.