• Title/Summary/Keyword: methylene blue value

Search Result 54, Processing Time 0.021 seconds

In vitro evaluation of a newly produced resin-based endodontic sealer

  • Song, Yoo-Seok;Choi, Yoorina;Lim, Myung-Jin;Yu, Mi-Kyung;Hong, Chan-Ui;Lee, Kwang-Won;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.3
    • /
    • pp.189-195
    • /
    • 2016
  • Objectives: A variety of root canal sealers were recently launched to the market. This study evaluated physicochemical properties, biocompatibility, and sealing ability of a newly launched resin-based sealer (Dia-Proseal, Diadent) compared to the existing root canal sealers (AHplus, Dentsply DeTrey and ADseal, Metabiomed). Materials and Methods: The physicochemical properties of the tested sealers including pH, solubility, dimensional change, and radiopacity were evaluated. Biocompatibility was measured using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. For microleakage test, single-rooted teeth were instrumented, and obturated with gutta-percha and one of the sealers (n = 10). After immersion in 1% methylene blue solution for 2 weeks, the specimens were split longitudinally. Then, the maximum length of staining was measured. Statistical analysis was performed by one-way analysis of variance followed by Tukey test (p = 0.05). Results: Dia-Proseal showed the highest pH value among the tested sealers (p < 0.05). ADseal showed higher dimensional change compared to AHplus and Dia-Proseal (p < 0.05). The solubility values of AHplus and Dia-Proseal were similar, whereas ADseal had the lowest solubility value (p < 0.05). The flow values of sealer in increasing order were AHplus, DiaProseal, and ADseal (p < 0.05). The radiopacity of AHplus was higher than those of ADseal and Dia-Proseal (p < 0.05). The cell viability of the tested materials was statistically similar throughout the experimental period. There were no significant differences in microleakage values among the tested samples. Conclusions: The present study indicates that Dia-Proseal has acceptable physicochemical properties, biocompatibility, and sealing ability.

A STUDY ON THE SHEAR BOND STRENGTHS AND MICROLEAKAGES OF THREE BONDING AGENTS ON DENTIN (상아질 접착제의 전단결합강도와 미세누출에 관한 연구)

  • Kim, Jeong-Ho;Cho, Young-Gon;Moon, Joo-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.680-692
    • /
    • 1997
  • New bonding agent systems have been supplied which operators can simply apply to conditioned tooth surfaces. The purpose of this study was to evaluate the shear bond strengths and the microleakages of three bonding agents and composite resins to dentin. Seventy-five extracted human maxillary and mandibular molar teeth were used in this study. For the shear bond strength test, the entire occlusal dentin surfaces of thirty teeth were exposed with Diamond Wheel Saw and smoothed with Lapping and Polishing Machine (South Bay Technology Co., U.S.A). For the microleakage test, Class V cavities were prepared in the buccal surfaces of fourtyfive teeth. They were randomly assigned into 3 groups according to dentin bonding agents ($Scotchbond^{TM}$ Multi-Purpose plus, ONE-$STEP^{TM}$ and Prime & $Bond^{TM}$)and composite resins (Z-100, $Aelitefil^{TM}$ and TPH $Spectrum^{TM}$) to be used. Bonding agents and composite resins were bonded to exposed dentin surfaces of the tooth crown and to Class V cavities on the buccal surfaces respectively according to manufacturer's directions. The shear bond strengths were measured by universal testing machine($U^{TM}$ AGS-100, Japan). In addition, the degree of micro leakage at the occlusal and gingival margin was examined by 2 % methylene blue and stereomicroscope(Olymous SZH 10, Japan). The results were as follows: 1. The shear bond strength to dentin was the highest value in SBMP-Plus group($16.68{\pm}7.38$ MPa) and the lowest value in Prime & Bond group($11.61{\pm}5.82$ MPa), but there was no significant difference of shear bond strength among three groups. 2. The degree of microleakage at both occlusal and gingival margin was showed the lowest in SBMP-Plus group and the highest in ONE-STEP group. 3. At both occlusal and gingival margin, there was significant difference of microleakage between SBMP-Plus and ONE-STEP/ Prime & Bond groups(p<0.05), but no significant difference of microleakage between ONE-STEP and Prime & Bond group(p>0.05).

  • PDF

A Study on the Manufacture of Activated Carbon using Indonesian Coal (인도네시아 석탄을 이용한 활성탄 제조에 관한 연구)

  • Baek, Ill-Hyun;Kim, Tae-Young;Yeon, Ik-June;Lee, Jeong-Sik;Lee, Dong-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.9 no.3
    • /
    • pp.419-423
    • /
    • 1998
  • Indonesian coal-based activated carbon was manufactured with steam-reaction method. Also effects of carbonization temperature and steam amount on the process yield and quality of the product were investigated at the activation temperature of $900^{\circ}C$. The rotary kiln type furnace was used for both carbonization and activation and the optimum operation conditions were carbonization temperature of $700^{\circ}C$, steam amount of 2.7g steam/g char and activation temperature of $900^{\circ}C$. At this condition, the iodine value of activated carbon was 1,010 mg/g. Methylene Blue Adsorption Number was 230mg/g and B.E.T. surface area was $1,020m^2/g$ with the hardness about 97.

  • PDF

THE EFFECT OF THE ENDODONTIC ACCESS CAVITY ON THE MARGINAL LEAKAGE OF CROWNS (금전장관 수복물을 통한 치수강 개방이 금전장관 수복물의 미세변연누출에 미치는 영향)

  • Kim, Eui-Seong;Chung, Jin-Ho;Kim, Yong-Kun
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.389-393
    • /
    • 2002
  • The marginal integrity of the crown can be broken during endodontic access cavity preparation due to the vibration of burs. Therefore, the purpose of this study was to evaluate the effect of endodontic access cavity preparation on the marginal leakage of full veneer gold crowns. 24 intact molars were mounted in acrylic resin blocks and prepared for crowns by a restorative dentist and crowns were cast with gold alloy. 20 Crowns were cemented with glass ionomer cement and 2 crowns were not cemented for positive control. 200 thermo-cycles from 5$^{\circ}C$ to 5$0^{\circ}C$ with a travel time of 20s were completed. Then samples were randomly divided into 2 experimental groups of 9 each. Endodontic access preparation and zinc-oxide eugenol temporary fillings were done in Group 1. Teeth in Group 2 were not treated. Samples were coated with 2 layers of nail varnish and were immersed in 1% methylene blue dye for 20 hrs. Endodontic access was prepared in 2 samples, which were coated with nail varnish on all surfaces for negative control. After washing in running water gold crowns were cut with a #330 bur. Four buccolingual sections, 2 mm apart, were cut from the central section of each tooth and were examined and scored under the microscope for dye leakage. Score 1: leakage to the cervical 1/3 of the axial wall, Score 2: leakage to the middle 1/3 of the axial wall, Score 3: leakage to the coronal 1/3 of the axial wall, Score 4: leakage to the occlusal surface. The median value for Group 1 is 4 and for Group 2 is 2. The result of this study showed that samples in Group 1 leaked more than those in Group 2. This finding was significant(P<0.001).

Modifying Effect of Indole-3-carbinol on Azoxymethane-induced Colon Carcinogenesis

  • Kang, Jin-Seok
    • Biomedical Science Letters
    • /
    • v.16 no.4
    • /
    • pp.381-385
    • /
    • 2010
  • Indole-3-carbinol (I3C), one of naturally occurring main components in cauliflower vegetables, is supposed to have a chemopreventive potential in experimental animals and humans. This study was investigated to examine chemopreventive effect of I3C on colon carcinogenesis induced by azoxymethane (AOM) using C57BL/6J mice. Mice were divided into three groups (10 or 9 mice/group). All mice were subcutaneously injected with AOM (5 mg/kg body weight, four times at weekly interval). After AOM treatment, animals of group 1 were fed by AIN-76A pellets as a basal diet. Animals of groups 2 and 3 were given I3C containing diets (100 and 300 ppm in diets, respectively) for 6 weeks until sacrifice. All mice were sacrificed at week 10 and the aberrant crypt foci (ACF) of the colonic mucosa were assessed after staining with methylene blue. Total numbers of ACF/colon in group 2 ($10.1{\pm}5.1$) or group 3 ($10.6{\pm}5.3$) were decreased compared to the values of group 1 ($14.4{\pm}10.2$). Among numbers of ACF formation, 5, 7, 8 and 10 ACF in group 2 and 3 were greatly different those of group 1. Total numbers of aberrant crypts (AC)/colon of group 2 ($20.1{\pm}10.1$) or group 3 ($22.0{\pm}10.9$) were decreased compared to the value of group 1 ($33.7{\pm}24.7$). Taken together, it suggests that I3C treatment may retard mouse colon carcinogenesis even after administration of AOM.

GINGIVAL MARGIAL LEAKAGE AND BONDING PATTERN OF THE COMPOSITE RESIN INLAY ACCORDING TO VARIOUS THICKNESS OF DIE SPACER (Die spacer의 두께에 따른 복합레진 inlay의 치은 변연부 미세누출 및 접착양태에 관한 연구)

  • Park, Tae-Il;Shin, Dong-Hoon;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.152-163
    • /
    • 1995
  • This experiment was performed to observe the adhesion pattern and microleakage in the gingival margin according to variation in the resin cement thickness which results from thickness of Die spacer. which is considered to effect the adaptability of the composite resin inlays. Clearfil CR inlays were fabricated on stone models with CR Sep applicated once and Nice fit twice, 4 times, and 6 times each. After 2nd curing within the CRC-100 oven, CR inlays were cemented with CR inlay cement. Dye(2% methylene blue) penetration and adhesion pattern were evaluated after sectioning of gingival margin into :3 pieces. The results were as follows ; 1. The thickness of resin cement showed unevenchanging pattern with that of die spacer, namely, it was increased until 4 times' application of Nice-Fit but was decreased with 6 times' application of that. 2. The degree of dye penetration wasn't affected by cement thickness within a limited value. 3. Most of dye penetration was shown through the interface between cement and enamel rather than the interface between cement and CR inlay. This shows that the affinity of resin cement for CR inlay was superior to the adhesive strength with tooth structure. 4. No gap was found at the interface between enamel and cement but some showed separation between dentin and cement. It is concidered that the contraction force of cement was less than the bond strength with the enamel. 5. Lots of voids were found in the CR inlay and resin cement. There was a pooling tendency of bonding agent and cement in the axiogingival line angle portion. 6. In some specimens, cracks were shown in enamel margin. From this it could be considered that cavity preparation and surface treatment weakened the tooth structure.

  • PDF

A STUDY ON THE MICROLEAKAGE OF RETROFILLED TEETH WITH VARIOUS MATERIALS AND INSTRUMENTS FOR CAVITY PREPARATION (역행충전시 와동형성 기구 및 수복재에 따른 변연누출에 관한 연구)

  • Lee, Jae-Yong;Cho, In-Ho;Hong, Chan-Ui;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.187-196
    • /
    • 1993
  • The purpose of this study was to evaluate the microleakage of retrofilled teeth with various materials [non-zinc Amalgam, IRM, Ketac-silver, CGP(cold-burnished, ultrafil)[and instruments for cavity preparation. Root apex were resected 2mm from apex horizontally and class I cavities were prepared in 2mm denpth, 1.5mm width and were filled with above mentioned materials. Root apex were resected 2mm from apex horizontally and class I cavities were prepared in 2mm depth, 1. 5mm width and were filled with above mentioned materials. 2% methylene blue dye solution was used for 4 days immersion and the linear leakage was measured with calipers and the volumetric leakage was determined with a spectrophotometer. The results were as follows : 1. Amalgam group showed the greatest amount of leakage and Ketac-silver group showed the least value. 2. By linear leakage test, the group retrofilled with Ketac-silver, or CGP showed better seal than the group of Amalgam or IRM. This was shown in both retrograde tip and Conventional method. 3. By volumetric leakage test, the group retrofilled with Ketac-silver showed significantly better seal than the group with IRM in retrograde tip method. 4. By volumetric leakage test, the group retrofilled with Ketac-silver showed significantly better seal than the group with Amalgam in the Conventional method.

  • PDF

Methemoglobinemia caused by a low dose of prilocaine during general anesthesia

  • Shibuya, Makiko;Hojo, Takayuki;Hase, Yuri;Kimura, Yukifumi;Fujisawa, Toshiaki
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.4
    • /
    • pp.357-361
    • /
    • 2021
  • Methemoglobinemia is a blood disorder in which an abnormal amount of methemoglobin is produced, and prilocaine is one of the drugs that can cause this disorder. The maximum recommended dose of prilocaine is 8 mg/kg. We report a case of methemoglobinemia caused by the administration of 4.2 mg/kg of prilocaine without other methemoglobinemia-inducing drugs during general anesthesia. A 17-year-old girl with hyperthyroidism and anemia was scheduled to undergo maxillary sinus floor elevation and tooth extraction. The patient's peripheral oxygen saturation (SpO2) decreased from 100% at arrival to 95% after receiving prilocaine with felypressin following induction of general anesthesia. However, the fraction of inspired oxygen was 0.6. Blood gas analysis showed that the methemoglobin level was 3.8% (normal level, 1%-2%), fractional oxygen saturation was 93.9%, partial pressure of oxygen was 327 mmHg, and arterial oxygen saturation was 97.6%. After administration of 1 mg/kg of methylene blue, her SpO2 improved gradually to 99%, and the methemoglobin value decreased to 1.2%. When using prilocaine as a local anesthetic, it is important to be aware that methemoglobinemia may occur even at doses much lower than the maximum recommended dose.

Study of Utilization of Natural Zeolites as Functional Materials for Water Purification (I): Cation Exchange Property of Domestic Zeolites (천연 제올라이트의 수환경 개선용 기능성 소재로의 활용에 관한 연구 (I): 국내산 제올라이트의 양이온 교환 특성)

    • Journal of the Mineralogical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.135-149
    • /
    • 2003
  • Domestic zeolite ores are mostly composed of Ca-type clinoptilolite, accompanying a little amounts of mordenite. However, other types of zeolite ores rich in ferrierite, heulandite, or mordenite are less commonly found. Based on the quantitative XRD analysis, zeolite contents are determined to be nearly 50∼90 wt%. Impurities (mostly > 10 wt%) in the zeolite ores chiefly consist of quartz, feldspar, smectite, and opal-CT. The determined CEC values ($CEC_{AA}$ ) of powdery samples (grain size: < 125 $\mu\textrm{m}$) of zeolite ores by the Ammonium Acetate method are mostly higher than 100 meq/100 g. Some zeolites from the Guryongpo area, corresponding to the clinoptilolite ore, are measured to be dominantly high in CEC values ranging 170∼190 meq/100 g. Cation exchange property of the zeolite ores varies greatly depending on the types or zeolite species present in the ores. Despite of the lower grade in zeolite content, the $CEC_{AA}$ of ferrierite ore is comparatively high. Compared to this, the $CEC_{AA }$ of heulandite ore is very low, though the zeolite ore exhibits the highest grade ranging up to about 90 wt%. In addition, the CEC values calculated theoretically from the framework composition of clinoptilolite-heulandite series are not consistent with those determined by the cation exchage experiment. The measured $CEC_{AA}$ of clinoptilolite ores are generally higher than those of heulandite ores. This may be due to the higher Ca abundance in exchangeable cation composition and the presence of probable stacking faults in heulandite. The variation of $CEC_{CEC}$ is roughly proportional, though not strictly compatible, to the zeolite contents in clinoptilolite ores. It seems to be caused by the fact that the $CEC_{AA}$ of clinoptilolite locally varies depending on crystal-chemical diversity, i. e., the variation in framework composition (Si/Al) and exchangeable cation composition (especially, the contents of Ca and K). In addition, the determined CEC values ($CEC_{MB}$ ) of zeolite ores by the Methylene Blue method are much higher than those calculated from smectite contents. It suggests a probable reaction of Methylene Blue ion ($C_{16}$ $H_{18}$ $N_3$S+) with larger-pore zeolites than clinoptlolite-heulandite series, i.e., ferrierite and mordenite as well as with smectite. This can be supported by the fact that the ferrierite ore accompanying little amount of smectite has the highest value in CE $C_{MB}$ .

Studies on the Post-hatching Development of Sertoli and Leydig Cells in the Testis of Korean Native Chickens (한국재래 닭 고환 지지세포와 간질세포의 부화 후 발달에 관한 연구)

  • Tae H. J.;Jang B. G.;Choi C. H.;Park Y. J.;Yang H. H.;Kim I. S.
    • Korean Journal of Poultry Science
    • /
    • v.32 no.2
    • /
    • pp.125-133
    • /
    • 2005
  • Morphometric changes in testicular Sertoli and Leydig cells from hatching to adulthood were studied using Korean native chickens of 1, 2, 4, 6, 8, 10, 12, 14, 16, 18, 21, 24, 28, 32, 44, 52 and 64 weeks (n=13 chickens per group) of age. The objective of this study was to understand the developmental phase of the Sertoli and Leydig cells with age. Testis of chickens was fixed by whole body perfusion using a fixative containing $2.5\%$ glutaraldehyde in cacodylate buffer, processed and embedded in Epon-araldite. Using 1 Um sections stained with methylene blue-azure II, qualitative and quantitative (stereological) morphological studies were performed. The average volume of a testis of 1 week old Korean native chickens was determined as $0.148\;cm^3$ and the parameter increased linearly from 1 week to 21 weeks days $(28.86\;cm^3)$, and did not change from 21 weeks to 64 weeks. The volume density of the seminiferous tubules increased with age from $32.6\%$ at week 1 to $92.89\%$ at week 64. The volume density of the interstitium represents $67.4\%$ of the testicular parenchyma at week 1. This proportion progressively diminished during development to reach a value of $7.11\%$ at week 64. The volume density of the Leydig cells decreased almost linearly from 1 week $(4.9\%)$ to 14 weeks $(1.7\%)$ and remained unchanged thereafter. In contrast, the Sertoli cells occupied a volume density of $3.4\%$ at week 1, increased progressively up to 18 weeks of age $(10.79\%)$ and remained unchanged thereafter. The absolute volume of the Leydig and Sertoli cells per testis increased significantly from week 1 to week 21 but did not change significantly from week 24 to week 64. The number of Leydig cells per testis increased almost linearly from 1 week to 21 weeks, remained high and unchanged with advancing age. The number of Sertoli cells per testis increased gradually with age from 1 week to 14 weeks and remained unchanged thereafter.