• Title/Summary/Keyword: method of measurement

Search Result 15,876, Processing Time 0.042 seconds

A Preliminary Study on the In-line Concentration Measurement of Absorbent Solution (흡수용액의 In-line 농도측정을 위한 기초연구)

  • 민병혁;황덕용;정시영;구기갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.152-158
    • /
    • 2003
  • Titration method is one of the widely used methods for the concentration measurement of absorbent ammonia/water. However, this method is inconvenient because the solution should be extracted for the measurement. Moreover, significant error can be introduced by the evaporation of ammonia during the sampling and measuring procedure. In this study a reliable in-line concentration measurement method was proposed. To prove the validity of the concept, a measuring apparatus was designed, built, and tested with water. It is found that the location of flow inlet and exit is important in the measurement accuracy. The flow inlet and exit located in the middle of the test cell showed the best result. By the error analysis, it is expected that the ammonia concentration can be measured within the error of $\pm$0.18% assuming the error of 0.1 K in temperature measurement and 0.1 g in weight measurement.

Antenna Measurement on Cylindrical Surface in Fresnel Region Using Direct Far-Field Measurement System

  • Oh, Soon-Soo;Kim, Joung-Myoun;Yun, Jae-Hoon
    • ETRI Journal
    • /
    • v.29 no.2
    • /
    • pp.135-142
    • /
    • 2007
  • The small anechoic chambers built by many small-/medium-sized companies and universities present difficulties in testing electrically large antennas because the chamber size cannot satisfy the far-field criterion of large antennas. In this paper, a method for Fresnel-region measurement on a cylindrical surface with variation of the measurement height is proposed and verified by both calculations and experiments. We implement the proposed method using a direct far-field measurement system by adding a few supporting structures. The results show good accuracy.

  • PDF

A Study on Influencing Factors of Unit-Water Measurement method according to Electrostatic capacity (정전용량에 따른 단위수량 측정기법의 영향인자에 대한 실험적 연구)

  • We, Joon-Woo;Lee, Young-Jin;Kim, Jeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.232-233
    • /
    • 2013
  • The unit-water content in fresh concrete determines consistency, and play an important role in condensing the structure of concrete and enhancing the durability of concrete. The capacitance measurement method measure quickly unit-water content and is the best way to apply to construction site. In this study, the unit-water content of capacitance measurement method is estimated according to types and replacemment ratio of admixture. and the field application of capacitance measurement method is reviewed.

  • PDF

A Practical Measurement Method of the Occupied Bandwidth for 8-VSB DTV Signal Using Modified ACPR

  • Kim, Young Soo;Lee, Bong Gyou;Song, Kyeongmin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.7
    • /
    • pp.3550-3565
    • /
    • 2019
  • This paper proposes a new measurement method for the effective measurement of the 99% occupied bandwidth (OBW) at monitoring stations. Although the OBW measurement of radio signal is recommended by the International Telecommunication Union Radio (ITU-R) with several methods, there still does not exist a clear measurement recommendation or standard for terrestrial DTV signal on-air environment. Modified adjacent channel power ratio (MACPR), which can be applied to 8-VSB (Vestigial Side Band) DTV (Digital Television) signal, is herein defined to verify the results of measurements obtained using the proposed measurement method. MACPR is a proper measuring parameter for determining the measuring area of a monitoring station. From measurement results obtained in real field environment, it has been found that the OBW of 8-VSB DTV signal can be effectively measured in areas where the MACPR value is over 35 dB and when the measurements are repeated more than 600 times in the same reception site. It also has been verified that measured results are within an error range of +/-0.1% compared to results directly obtained at a transmission station. It is expected that the proposed method is able to be employed in order to determine the proper location of monitoring station and provide a reliable OBW measurement procedure for 8-VSB DTV signal on-air environment.

Modelling Method for Removing Measurement Uncertainty in Chip Impedance Characterization of UHF RFID Tag IC (UHF RFID 태그 칩의 임피던스 산출 불확실성 제거를 위한 모델링 방법)

  • Yang, Jeenmo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.12
    • /
    • pp.1228-1235
    • /
    • 2014
  • Input impedance of UHF RFID tag chip is needed to design a tag. In determining the chip impedance, direct measurement method is adopted commonly. In this paper, problems generated from fixtures that interface between tag chip and coaxial-oriented measurement instrument are investigated and the result of the problems is shown, when the direct measurement method is applied. As an alternative to the method, a modeling method is proposed and its validity and accuracy are shown.

A Study on the Virtual Grating Projection Moire Topography for the Shape Measurement of Human Face (인체형상 측정을 위한 가상격자 영사식 무아레 방법에 관한 연구)

  • 유원재;최정표;안중근;강영준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.49-52
    • /
    • 2001
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using projection moire topogrphy is very attractive because of it s high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection moire topography tested to measuring object with the $2\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the $2\pi$-ambiguity problem can be effectively overcome so as to treat large step discontinuities in measured objects.

  • PDF

A Long Range Accurate Ultrasonic Distance Measurement System by Using Period Detecting Method (주기인식 검출방식을 이용한 장거리 정밀 초음파 거리측정 시스템 개발)

  • Lee, Dong-Hwal;Kim, Su-Yong;Yoon, Kang-Sup;Lee, Man-Hyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.8 s.197
    • /
    • pp.41-49
    • /
    • 2007
  • In this paper, we proposed a new ultrasonic distance measurement system with high accuracy and long range. To improve accuracy and enlarge range, the time of flight of ultrasonic is calculated by the period detecting method. In the proposed ultrasonic distance measurement system, the ultrasonic transmitter and receiver are separated but synchronized by RF(Radio frequency) module. The experiment has been implemented from short distance 1m to maximum available distance 30m. And the period detecting method is compared with the conventional threshold level method. Experimental results show the accuracy and range of the distance measurement are improved by this period detecting method.

A Study of Form Measurement using Noncontact Sensor (비접촉식 센서를 사용한 형상 측정 연구)

  • 송정섭;황윤호;배종일;이만형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.407-410
    • /
    • 1995
  • Many researches on measurement technology has been made and developed by various methods. Considering the measurement environment with cutting fluid, coolant and the like, contact type measurement methods are mostly used. But contact measurement method has measuring force and so the sensing head becomes worn. By these reasons, we considered sensors not influenced by the former fluid and so can acquire accrate measured values using error compensation due to temperature and vibration. For this purpose, eddy current sensors and Extended kalman Filter Algorithm for processing measured data has been used. In this paper, we present new technology that can be used for measuring workpiece with previous bad environment using direct method and comparison measurement method. We used cylindrical workpieces which were produced by grinding machine for the target.

  • PDF

Design of Measurement System and Thrust Force Analysis Method for HB-Type Linear Pulse Motor (HB형 선형 펄스모터의 추력 계산법의 비교 및 측정장치 설계)

  • Bae D.K.;Kim K.H.;Park H.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.141-145
    • /
    • 2003
  • The linear motor available for linear transition motion, because of its advantages, the motor design and its application have gradually increased, but the quantitative measurement system of thrust force has not been generalized. So, this paper proposes the modeling, computation method, and measurement system of linear thrust force in HB-type linear pulse motor. As the computation method of thrust force in linear motor is presented and the measurement system is designed, and manufactured, it would be verified that reliability of measurement method and measurement system, considering on and comparing the results of mathematical modeling with measured values of static thrust force and dynamic one.

  • PDF

Improvement of Calibration Method of Thermochromic Liquid Crystal Reflecting Measurement Angle (측정각도를 고려한 액정교정기법의 개선)

  • Yoon, Soon-Hyun;Sim, Jae-Kyung;Woo, Chang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.188-194
    • /
    • 2000
  • Thermochromic liquid crystal reflect a unique color at even temperature. Therefore, they have been successfully applied to non-intrusive heat transfer research. Hue capturing method is widely used in the quantitative measurement from the TLC image. However it is affected by several measurement conditions. The distances of camera and light source have little influence on the color, but the value of hue is seriously affected by the measurement angle. In this study, the hue capturing method is improved by considering the effect of measurement angle. This improved calibration method can diminish the misreading of temperature caused by curvature of test surface.