• Title/Summary/Keyword: metering device

Search Result 79, Processing Time 0.029 seconds

Case Study on Auto Meter Reading Protocol Certificate System for Smart Grid and Standardization (스마트 그리드를 위한 원격검침 표준 프로토콜 인증 시스템 구축과 표준화에 관한 연구)

  • Choi, In-Ji;Park, Byung-Seok;Choi, Hyo-Yeol;Myung, No-Gil;Lee, Sang-Youm
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.1B
    • /
    • pp.75-85
    • /
    • 2012
  • In this paper, we introduce the case study on the certificate system for Auto Meter Reading protocol, Device Language Message Specification which is a common language between metering devices and protocol with compatibility and conformance to the IEC 62056 standards. KEPCO has contributed to improve interoperability between different devices of multi vendors through the DLMS standard tests and led the smart metering industry in Korea. KEPCO has AMR system and successful business model for 550 thousands of households based on 24Mbps broadband powerline communications using its infrastructure. We have plan to continue on standardization activities stratagemically by participating in IEC working groups for the purpose of occupying the core technology of Smart Gird.

Data Interworking Model Between DLMS and LwM2M Protocol (DLMS와 LwM2M 프로토콜 간 데이터 연동 모델 연구)

  • Myoung, Nogil;Park, Myunghye;Kim, Younghyun;Kang, Donghoon;Eun, Changsoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.1
    • /
    • pp.29-33
    • /
    • 2020
  • Despite the same system architecture and operation principle, Advanced Metering Infrastructure (AMI) and Internet of Things (IoT) are recognized as a heterogeneous system. This is due to the different object modeling and communication protocols used in smart meters and sensors. However, data interworking between AMI and IoT is expected to be inevitable in the future. In this paper, we propose Device Language Message Specification (DLMS) to Lightweight Machine to Machine (LwM2M) conversion model. The proposed interworking model can reduce the packet size by 46.5% compared to that of the encapsulation method.

Design of Advanced Metering Infrastructure Network Based on Multi-Channel Cluster (다중채널 클러스터 기반의 AMI 네트워크 설계)

  • Choi, Seok-Jun;Shim, Byoung-Sup;Chae, Soo-Kwon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.3
    • /
    • pp.207-215
    • /
    • 2013
  • This paper is channel assignment and scheduling techniques for efficient wireless AMI network. In AMI system, the multi-channel cluster network to be proposed defines the communication channel between NC (Network Coordinator) and CDA (Clustered Data Aggregator) as the network channel. CDA and OMD(Out Meter display) and communication channel between SMD(Smart Meter Device) are defined as the group channel. AMI network of the multi-channel cluster based in which the network channel and group channel is mixed increases the administration efficiency through the physical/logical consumer channel clustering. The reliability of inspection data through the channel use distinguished between the adjacent cluster is enhanced. In addition, the fast aggregation of data is possible and the size of a metering network is increased through the channel allocation of the multichannel cluster based.

Flow rate Measurement Using Segmental Wedge as a Restriction Device for Differential Pressure (Segmental Wedge를 이용한 차압식 유량측정 방법)

  • Yoon J.Y.;Sung N.W.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.3 s.36
    • /
    • pp.22-28
    • /
    • 2006
  • The discharge coefficient in segmental wedge haying ninety degrees yeller angle for the five kinds of opening ratio with differential pressure taps located at both upstream and downstream of one diameter of pipe was measured. Main purpose of this work is placed on specifying the characteristic of discharge coefficient of a segmental wedge used as a primary element of flow metering devices, and suggestion for the fixed location of pressure taps useful. Although the range of the opening ratio over this work is more expanded than previous studies. The opening ratios of segmental wedge, namely 0.3, 0.4, 0.5, 0.6 and 0.7 were investigated. The Reynolds number based on the spool inside diameter ranges from 12,000 to 380,000.

Design and Implementation of Web-RTU Based on 8 bit MPU (8 비트 MPU 기반의 Web-RTU의 설계 및 구현)

  • Hong, Soon-Pil;Kim, Eun-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.89-91
    • /
    • 2004
  • In SCADA systems, an RTU is a device installed at a remote location that collects data, codes the data into a format that is transmittable and transmits the data back to a central station, or MTU. An RTU also collects information from the master device and implements processes that are directed by master device. RTUs are equipped with input channels for sensing or metering, output channels for control, indication or alarms and a communications port. In general, the data are transmitted via a wired communication infrastructure such as RS422 or RS485 between RTU and MTU. But, limited range of wired communication doesn't allow the system to cover remote areas over the limitation, and building a wired communication network is not easy in the circumstances. In this Paper, we design and implement a smart cost-effective Web-RTU that can communicate with MTU via Web. Web is of benefit to the Web-RTU, because it is not only free from the distance limitations, but also is built easily and cost-effectively wherever Internet resources are available. Additionally, Web can be easily applied to the SCADA system with the development of hardware and software for communications. The Web-RTU has a program memory, a data memory and a RAM inside, and uses Atmega128, low-cost 8 bit micro-processor with eight AI(Analog Input). It performs well enough to implement all existing roles of RTU.

  • PDF

Design and Application of a LonRF Device based Sensor Network for an Ubiquitous Home Network (유비쿼터스 홈네트워크를 위한 LonRF 디바이스 기반의 센서 네트워크 설계 및 응용)

  • Ro Kwang-Hyun;Lee Byung-Bog;Park Ae-Soon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.3
    • /
    • pp.87-94
    • /
    • 2006
  • For realizing an ubiquitous home network(uHome-net), various sensors should be able to be connected to an integrated wire/wireless sensor network. This paper describes an application case of applying LonWorks technology being widely used in control network to wire/wireless sensor network in uHome-net and the design and application of LonRF device that consists of a neuron chip including LonTalk protocol, a 433.92MHz RF transceiver, a sensor, and application programs. As an application example of the LonRF device, the LonRF smart badge that can measure the 3D location of objects in indoor environment and interwork with the uHome-net was developed. LonRF device based home network services were realized on the uHome-net testbed such as indoor positioning service, remote surveillance service and remote metering service were realized. This research shows that LonWorks technology based sensor network could be applicable to the control network in an ubiquitous home network and the LonRF device can be used as a wireless node in various sensor networks.

  • PDF

Development of an Integrated Meter Reading Home Concentrate Device (통합 원격검침 지시장치 개발)

  • Park, Jae-Sam
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.37-42
    • /
    • 2015
  • This paper highlights the home concentrate device(HCD) that integrates the data reading and display of the six types of meters (water, hot water, heating, cooling, gas and electricity) used in Korean residential areas. Unlike the conventional system which utilizes single MCU, the developed system uses two MCUs for one MCU to gather the meter readings and for the other MCU to communicate to the server computer. Hard ware design, communication protocols, LCD design and program structures are discussed and the test results are shown in this paper. With the implementation of integrated meter reading, the developed system can increase the popularity of automatic meter reading(AMR) with its better scalability, pricing, installation fee, maintenance and faster response.

Flowrate Measurement Using Segmental Wedge as a Restriction Device for Differential Pressure (Segmental Wedge를 이용한 차압식 유량측정 방법)

  • Yoon, J.Y.;Sung, N.W.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.302-307
    • /
    • 2005
  • The discharge coefficient in segmental wedge having ninety degrees vertex angle for the five kinds of opening ratio with differential pressure taps located at both upstream and downstream of one diameter of pipe was measured main purpose of this work is placed on developing the proper form of an equation for the discharge coefficient of a segmental wedge used as a primary element of flow metering devices, and from thata six-term equation which can express the variability of opening ratios was developed. The same assumption and hypotheses were used and tested for all procedures as conventional differential producers; however, the range of the opening ratio over this work is more expanded than previous studies. The opening ratios of segmental wedge, namely 0.3, 0.4, 0.5, 0.6 and 0.7 were investigated the Reynolds number based on the spool inside diameter ranges from 12,000 to 380,000, the resulting equation for the discharge coefficient is relatively simple; it contains only one variable-opening ratio because the characteristic of discharge coefficient of segmental wedge has little connection with the Reynolds number as shown by previous studies.

  • PDF

Survey on Software-based Power-Metering Framework for Android Platform (안드로이드 플랫폼을 위한 소프트웨어 기반의 전력 소비 측정 프레임워크 비교)

  • Yi, Jun-min;Noh, Dong-kun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.765-768
    • /
    • 2012
  • Recently, the supply ratio of smart devices application has become increasable, utilization of device increases constantly. At the same time, used application is more gentrified. However, using time of devices is decreased. To solve these problems, many research is studying about the hardware/software. One of them is profiling power consumption by process units. The process can be managed, based on measured energy consumption data. These means that it can efficiently use the residual energy. Application at the stage of program design can analyze and used-energy using the trace by considering the low-power can design. In this paper, we studied software-based power-metering framework for android platform. We survey each process-level power consumption measurement techniques, compare advantages and disadvantages of the technique and propose improved measures.

  • PDF

Applicability of Fuel Supply System for HCNG Engine (HCNG 엔진용 연료시스템의 적용성 평가)

  • Lee, Sungwon;Lim, Gihun;Park, Cheolwoong;Choi, Young;Kim, Changgi;Lee, Janghee
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.2
    • /
    • pp.146-153
    • /
    • 2013
  • CNG buses has contributed to improve air quality in cities. But it is difficult to meet the next emission regulations such as EURO-VI without the help of additional post-processing device. Hydorgen has higher flame speed and lower combustion temperature that make it thermal efficiency increase with leaner operation. Using hydrogen natural gas blend (HCNG) fuel is promising technology which can reduce $NO_x$ and $CO_2$ emissions for a natural gas vehicle. However, fuel flow rate of HCNG should be increased since hydrogen's energy density per volume is much smaller than natural gas. In the present study, the characteristics of fuel supply system and its applicability were evaluated in a heavy duty natural gas engine. The results showed that the potential of fuel pressure regulator and fuel metering valve had enough capacity with HCNG. Employed mixer did not affect the distribution characteristics of mixture.