• 제목/요약/키워드: meter unit

검색결과 186건 처리시간 0.025초

고 전력 Source Measurement Unit의 설계 및 제작 (Design and Implementation of High Power Source Measurement Unit)

  • 이상구;백왕기;박종식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.860-863
    • /
    • 2003
  • In this paper high power SMU(Source Measurement Unit) having 50V/1.5A source/measure range has been designed and implemented. The SMU has two operation mode, voltage mode and current mode. The SMU can be used as variable voltage source, variable current source, voltage meter, or current meter. Combining two different unit, output power can be doubled as 100V/1.5A. The developed SMU tan be used many semiconductor testing system and electronic device inspecting system.

  • PDF

LoRaWAN IoT 원격검침장치 개발 (Development of LoRaWAN IoT Automatic Meter Reading Systems)

  • 박재삼
    • 한국전자통신학회논문지
    • /
    • 제15권5호
    • /
    • pp.913-922
    • /
    • 2020
  • 본 논문에서는 무라타 전자의 LoRa RF 모듈을 이용한 LoRa 통신모듈을 설계하여 디지털미터기에 장착하는 구성과, 다수의 미터기 데이터를 DCU(Data Concentrate Unit)에서 정합하여 LoRaWAN 으로 네트워크를 구성하는 원격검침 네트워크 구성 방법을 제시한다. 개발된 시스템은 수요자의 구성에 따라 미터기를 직접 네트워크에 연결하거나 DCU로 정합하여 네트워크에 연결하도록 선택가능하게 함으로써 기존 시스템 보다 네트워크 구성에 있어서 용이하고 경제적으로 설치가능하다. 개발된 시스템은 디지털수도미터기를 예로하여 구성하였지만 전기, 수도, 가스, 온수 및 난방 등 타계량기의 계량값을 원격검침 하는데도 적용가능하다. 주요개발 내용은 디지털미터기, LoRa 모듈, DCU 설계, 구성 및 제작과 LoRaWAN 네트워크 연결, 미터 데이터를 서버로 전송하는 방법이며, 이들 요소들을 연계하여 시스템을 구성하고 실제 LoRaWAN 통신을 테스트하고 그 결과를 보여준다.

대형 건설장비용 주행유닛의 토크 측정기술에 관한 연구 (A study on torque measuring technique for track drive unit of earthmoving equipment with very large capacity)

  • 이용범;한승호
    • 한국기계가공학회지
    • /
    • 제8권4호
    • /
    • pp.97-103
    • /
    • 2009
  • Since a demand for an extensive range of earthmoving equipment like a hydraulic excavator with a capacity of 85tons has been asked in construction fields, a performance of its track drive unit has to be verified experimentally. Among the verification of the performances, a torque measurement is at issue, in which a torque meter is utilized widely. However, the very large scaled torque meter is necessary when a discharged torque from the track drive unit is increased significantly. In addition, the price for experimental set-up of a torque meter is too high due to its limitation of the geometry such as long length, and a break down in operation occurs frequently. In this study, to measure a high torque up to 200,000Nm, a new technique was proposed as an alternative of conventional measurement by using a torque meter. The new technique enables to measure the high torque stably in a compact space via a torque arm and two load cells. The experimental results showed a propriety of the proposed torque measuring technique for a track drive unit with very large capacity.

  • PDF

세대집중화장치를 포함하는 스마트 전력량계를 이용한 AMI 시스템 (AMI System Using Smart Electricity Meter Embedded with Home Concentrate Unit)

  • 박재삼
    • 한국전자통신학회논문지
    • /
    • 제14권3호
    • /
    • pp.537-546
    • /
    • 2019
  • 본 논문에서는 스마트 전력량계에 세대집중화장치를 내장하여 AMI에 필요한 가스, 수도, 온수, 난방 검침을 일괄검침하는 시스템과, 검침데이터를 에너지정보표시장치(IHD: In House Display)와 서버로 전송하는 방법을 구성하여 보다 경제적으로 AMI 시스템을 구축하는 방법을 제시한다. 개발된 시스템은 기존 시스템 보다 네트워크 구성에 있어서 가격이 저렴하고 운영비용이 절감되며 설치가 용이하다. 개발된 시스템을 적용하면 전기, 수도, 가스, 온수 및 난방의 5종 계량기의 계량값을 원격검침 하고 이에 대한 AMI 적용을 보다 용이하게 구성 가능하다. 주요개발 내용은 스마트 전력량계 구성과 세대집중화장치 결합 및 이들 데이터를 IHD와 서버로 전송하는 방법이며, 이들 요소들을 연계하여 시스템을 구성하고 실제 검침 동작구성을 테스트하고 그 결과를 보여준다.

A Comparative Analysis of Patient Visibility, Spatial Configuration and Nurse Walking Distance in Korean Intensive Care Units(ICUs) - Focused on single corridor, Pod and Composite type units

  • 울라 우바이드;박재승
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권4호
    • /
    • pp.37-45
    • /
    • 2016
  • Purpose: The purpose of this paper is to analyze a sample of single corridor, pod type and composite type of ICUs in terms of patient visibility, spatial configurations and nurse walking distance focused on Korean cases. Methods: The measures of static visibility were used to quantify the patient visibility (upper third part of the patient bed) from the nurse station. The measure of space programme and area distribution (patient zone percentage, staff zone percentage, circulation zone percentage, corridor length per bed, distance from nurse station (NS) to patient bed and departmental gross square meter (DGSM) per patient bed) were calculated by using AutoCAD and MS Excel programs. In the second step of analysis the values of space distribution were compared among the three type of ICUs as well as the nurse walking distance, DGSM per bed and gross factor. in the third step of analysis regression analysis was conducted for the possible correlation between visibility and space programme and area distribution factors as well as nurse walking distance factors. Results: (1) It was found that on average composite type unit offer highest value of patient visibility followed by pod type, while single corridor type unit offers the minimum value of patient visibility among the three plan typologies. (2) Average patient visibility and DGSM per bed shows a strong positive correlation ($r^2=0.75$) and p=0.026. (3) Average patient visibility and average distance from NS has a strong negative correlation ($r^2=0.78$), and P=0.02. (4) On average composite type unit offer the minimum walking distance from NS (7.22 meter) followed by pod type unit (8.35 meter) and single corridor (9.76 meter). (5) Maximum distance from NS was noted in single corridor (18.19 meter) followed by pod type unit (15.14 meter) and Composite type unit (11.1 meter). Implications: This study may contribute to the visibility analysis of existing and future ICU design in Korea to achieve maximum patient visibility and reduced nurse walking distance.

선박 유수분리기용 유분검출기의 개발 (Development of Oil Content Meter for Oily Water Separator in Ship)

  • 황정웅;정병건;김창화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.338-344
    • /
    • 2001
  • According to the MARPOL 73/78 of Convention, all ships should have oil filtering equipment and 15 ppm bilge which satisfy Requirements of MARPOL 73/78. This study is concerned with designing and manufacturing a prototype Oil content Meter(OCM) used in machinery area of ship. The prototype OCM is composed of two parts which are oil content sensing module and data processing unit. The oil content sensing module consists of infra-red light source, photo-diode light receivers, and a glass tube for bilge water sample. The data processing unit has a micro-processor as hard core and peripheral devices. The experimental results of prototype OCM and analysis of collected data reveal linear property between transmitted light and scattered light as long as the bilge water has low level content of oil. And this linear property leads to a oil content detecting method which is programmed and loaded into the data processing unit. The performance of the prototype OCM is compared with that of the commercial OCM in the market.

  • PDF

전통적인 길이 척도 환산에 대한 역사·문화적 재고 (A Study on Historical and Cultural Viewpoints of Traditional Measuring Units Conversion)

  • 이동명;김재효;강연석;고호경
    • 한국의사학회지
    • /
    • 제23권2호
    • /
    • pp.15-22
    • /
    • 2010
  • Currently, in Korea, all lengths are written in "meter" unit, and the non-statutory measuring units are banned for use. However, in some fields, traditional measuring units are widely used with necessary modifications, and people in such fields raise varying arguments on conversion to "meter" unit. This research examines traditional measuring units from historical and cultural viewpoints, and provides suggestions on how to improve consistency and standardization for more accurate and effective exchangeof scientific opinions.

대도시 주민의 근린옥외여가시설 선택모형을 기초로 한 시설지 배분에 관한 연구 (A Study on the Facilities Distribution based on the Choice Model of the Outdoor Leisure-Facilities in a Neighbourhood Unit of the Megalopolis Citizens. -In terms of the Comparison of Choice Models and the Limitations of Use Areas between the Megalopolis-)

  • 최기수;김한배;진양교;진상철;허미선
    • 한국조경학회지
    • /
    • 제23권1호
    • /
    • pp.123-139
    • /
    • 1995
  • The megalopolis citizens are reevaluating the expectant value and the perception of leisure aceording to increasing the level of their incomes, The leisure of citizens is increasing in the aspect of quantity and quality of life nowadays In the site planning of leisure, the concrete understanding about people's choice of a leisure site will be the most important thing, not only for the aspect of improvement of the quality of life but also efficiencies of the land use The purposes of chi study are firstly, to find out the factors which are influenced on a choice of Outdoor leisure facilities in neighbourhood unit and to Compare the Characteristics Of Choice models between the three metropolitan areas, secondly, to predict a limitation of use areal according to the change of a needed time based on the metropolitan's standard choice model For the choice model establishment this research used Logit Model which has been used in the field of the traffic, the tourism and the economics. This research made the results which find out the influencing variables with needed times, the accessibility and the percentage of facilities. The lindtations of use areas come out the results which are predicted according to the change of needed times as a most influencing factors. The range of each preferred leisure facility is about 956 meter distant in the neighbourhood park about 644 meter distant in the pocket park about 604 meter distant in the recreation center, about 628 meter distant in the tennis court about 974 meter distant in the private hob by facility and about 528 meter distant in the library from the apartment unit The recreation center and the library are nearer facilities than the other facilities. But these facilities are surveyed to be more or less influenced by an interesting progran, a context of events and the level of useful facilities, etc.

  • PDF

수중용 레벨메터의 제작 및 펄스-에코 특성 (Fabrication and Pulse-echo Response of Level-Meter for Underwater)

  • 양윤석;김철한;사공건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.935-937
    • /
    • 1999
  • In this study, 1-3 type composite specimens were fabricated with PZT powders prepared by the molten-salt synthesis method and Eccogel polymer matrix. A virtual level-meter was fabricated with a 1-3 type composite probe and electronic unit for underwater application. There was no difference in values between a virtual and measured level on its level meter.

  • PDF

10 nano-meter 분해능을 갖는 laser scale을 이용한 위치 결정 실험 (Experiment for Position Accuracy Using Laser Scale Unit with 10 Nano-Meter Resoultion)

  • 임선종;정광조;최재완
    • 한국정밀공학회지
    • /
    • 제17권1호
    • /
    • pp.21-26
    • /
    • 2000
  • This paper describes a positioning system for ultra-precision that will be utilized in semiconductor manufacturing field and precision machinery. This system is composed with laser scale unit with 10nm resolution, ball screw with LM guide, brushless DC servo motor, vibration isolator and is equipped in chamber for continuous measuring environment. The dynamic of table, the problem of servo control and the traceability for micro step motion are described. These data will be applied for getting more stable system with 50nm resolution.

  • PDF