• Title/Summary/Keyword: meter unit

Search Result 185, Processing Time 0.024 seconds

Design and Implementation of High Power Source Measurement Unit (고 전력 Source Measurement Unit의 설계 및 제작)

  • Lee, Sang-Gu;Baek, Wang-Gi;Park, Jong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.860-863
    • /
    • 2003
  • In this paper high power SMU(Source Measurement Unit) having 50V/1.5A source/measure range has been designed and implemented. The SMU has two operation mode, voltage mode and current mode. The SMU can be used as variable voltage source, variable current source, voltage meter, or current meter. Combining two different unit, output power can be doubled as 100V/1.5A. The developed SMU tan be used many semiconductor testing system and electronic device inspecting system.

  • PDF

Development of LoRaWAN IoT Automatic Meter Reading Systems (LoRaWAN IoT 원격검침장치 개발)

  • Park, Jae-Sam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.5
    • /
    • pp.913-922
    • /
    • 2020
  • In this paper, we propose a LoRa communication module using the LoRa RF module of Murata Electronics is designed to configure the IoT digital meter remote meter reading and a method of configuring a remote meter reading network by collecting multiple meter data in a DCU (Data Concentrate Unit) to configure a network with LoRaWAN. The developed system can be installed more easily and economically in the network configuration than the existing system by allowing the meter to be directly connected to the network or matched with a DCU to connect to the network according to the configuration of the consumer. The developed system was constructed using a digital water meter as an example, but it can also be applied to remote meter reading of the metered values of other meters such as electricity, water, gas, hot water and calorie meters. The main development contents are the design, configuration, and construction of digital meters, LoRa modules and DCUs, and how to connect the LoRaWAN network and transmit meter data to the server. By networking these devices, the system is configured, and the actual LoRaWAN communication is tested and the result is shown.

A study on torque measuring technique for track drive unit of earthmoving equipment with very large capacity (대형 건설장비용 주행유닛의 토크 측정기술에 관한 연구)

  • Lee, Yong-Bum;Han, Seung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.4
    • /
    • pp.97-103
    • /
    • 2009
  • Since a demand for an extensive range of earthmoving equipment like a hydraulic excavator with a capacity of 85tons has been asked in construction fields, a performance of its track drive unit has to be verified experimentally. Among the verification of the performances, a torque measurement is at issue, in which a torque meter is utilized widely. However, the very large scaled torque meter is necessary when a discharged torque from the track drive unit is increased significantly. In addition, the price for experimental set-up of a torque meter is too high due to its limitation of the geometry such as long length, and a break down in operation occurs frequently. In this study, to measure a high torque up to 200,000Nm, a new technique was proposed as an alternative of conventional measurement by using a torque meter. The new technique enables to measure the high torque stably in a compact space via a torque arm and two load cells. The experimental results showed a propriety of the proposed torque measuring technique for a track drive unit with very large capacity.

  • PDF

AMI System Using Smart Electricity Meter Embedded with Home Concentrate Unit (세대집중화장치를 포함하는 스마트 전력량계를 이용한 AMI 시스템)

  • Park, Jae-Sam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.3
    • /
    • pp.537-546
    • /
    • 2019
  • In this paper, a system that integrates a home concentrate unit(HCU) in a smart electricity meter to collects water, gas, hot water, and heating usage required for AMI has been proposed. The collected data could be transmitted to the in house display(IHD) and server to provide a more economical AMI system. The developed system is less expensive in the network configuration than the existing system, which could reduce the operating cost, and be easy to install. By applying the developed system, the usage of electricity, water, gas, hot water and heating could be measured and these make it easier to apply AMI system. The main contents of the development are the smart electricity meter and embedding of HCU into the smart electricity meter, and transferring these data to IHD and server to structure the AMI system. The each developed unit has been networked to structure the AMI system to perform the actual meter reading operation and show the result.

A Comparative Analysis of Patient Visibility, Spatial Configuration and Nurse Walking Distance in Korean Intensive Care Units(ICUs) - Focused on single corridor, Pod and Composite type units

  • Ullah, Ubaid;Park, Jae Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.4
    • /
    • pp.37-45
    • /
    • 2016
  • Purpose: The purpose of this paper is to analyze a sample of single corridor, pod type and composite type of ICUs in terms of patient visibility, spatial configurations and nurse walking distance focused on Korean cases. Methods: The measures of static visibility were used to quantify the patient visibility (upper third part of the patient bed) from the nurse station. The measure of space programme and area distribution (patient zone percentage, staff zone percentage, circulation zone percentage, corridor length per bed, distance from nurse station (NS) to patient bed and departmental gross square meter (DGSM) per patient bed) were calculated by using AutoCAD and MS Excel programs. In the second step of analysis the values of space distribution were compared among the three type of ICUs as well as the nurse walking distance, DGSM per bed and gross factor. in the third step of analysis regression analysis was conducted for the possible correlation between visibility and space programme and area distribution factors as well as nurse walking distance factors. Results: (1) It was found that on average composite type unit offer highest value of patient visibility followed by pod type, while single corridor type unit offers the minimum value of patient visibility among the three plan typologies. (2) Average patient visibility and DGSM per bed shows a strong positive correlation ($r^2=0.75$) and p=0.026. (3) Average patient visibility and average distance from NS has a strong negative correlation ($r^2=0.78$), and P=0.02. (4) On average composite type unit offer the minimum walking distance from NS (7.22 meter) followed by pod type unit (8.35 meter) and single corridor (9.76 meter). (5) Maximum distance from NS was noted in single corridor (18.19 meter) followed by pod type unit (15.14 meter) and Composite type unit (11.1 meter). Implications: This study may contribute to the visibility analysis of existing and future ICU design in Korea to achieve maximum patient visibility and reduced nurse walking distance.

Development of Oil Content Meter for Oily Water Separator in Ship (선박 유수분리기용 유분검출기의 개발)

  • 황정웅;정병건;김창화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.338-344
    • /
    • 2001
  • According to the MARPOL 73/78 of Convention, all ships should have oil filtering equipment and 15 ppm bilge which satisfy Requirements of MARPOL 73/78. This study is concerned with designing and manufacturing a prototype Oil content Meter(OCM) used in machinery area of ship. The prototype OCM is composed of two parts which are oil content sensing module and data processing unit. The oil content sensing module consists of infra-red light source, photo-diode light receivers, and a glass tube for bilge water sample. The data processing unit has a micro-processor as hard core and peripheral devices. The experimental results of prototype OCM and analysis of collected data reveal linear property between transmitted light and scattered light as long as the bilge water has low level content of oil. And this linear property leads to a oil content detecting method which is programmed and loaded into the data processing unit. The performance of the prototype OCM is compared with that of the commercial OCM in the market.

  • PDF

A Study on Historical and Cultural Viewpoints of Traditional Measuring Units Conversion (전통적인 길이 척도 환산에 대한 역사·문화적 재고)

  • Lee, DongMyung;Kim, JaeHyo;Kang, YeonSeok;Ko, HoKyoung
    • The Journal of Korean Medical History
    • /
    • v.23 no.2
    • /
    • pp.15-22
    • /
    • 2010
  • Currently, in Korea, all lengths are written in "meter" unit, and the non-statutory measuring units are banned for use. However, in some fields, traditional measuring units are widely used with necessary modifications, and people in such fields raise varying arguments on conversion to "meter" unit. This research examines traditional measuring units from historical and cultural viewpoints, and provides suggestions on how to improve consistency and standardization for more accurate and effective exchangeof scientific opinions.

A Study on the Facilities Distribution based on the Choice Model of the Outdoor Leisure-Facilities in a Neighbourhood Unit of the Megalopolis Citizens. -In terms of the Comparison of Choice Models and the Limitations of Use Areas between the Megalopolis- (대도시 주민의 근린옥외여가시설 선택모형을 기초로 한 시설지 배분에 관한 연구)

  • 최기수;김한배;진양교;진상철;허미선
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.23 no.1
    • /
    • pp.123-139
    • /
    • 1995
  • The megalopolis citizens are reevaluating the expectant value and the perception of leisure aceording to increasing the level of their incomes, The leisure of citizens is increasing in the aspect of quantity and quality of life nowadays In the site planning of leisure, the concrete understanding about people's choice of a leisure site will be the most important thing, not only for the aspect of improvement of the quality of life but also efficiencies of the land use The purposes of chi study are firstly, to find out the factors which are influenced on a choice of Outdoor leisure facilities in neighbourhood unit and to Compare the Characteristics Of Choice models between the three metropolitan areas, secondly, to predict a limitation of use areal according to the change of a needed time based on the metropolitan's standard choice model For the choice model establishment this research used Logit Model which has been used in the field of the traffic, the tourism and the economics. This research made the results which find out the influencing variables with needed times, the accessibility and the percentage of facilities. The lindtations of use areas come out the results which are predicted according to the change of needed times as a most influencing factors. The range of each preferred leisure facility is about 956 meter distant in the neighbourhood park about 644 meter distant in the pocket park about 604 meter distant in the recreation center, about 628 meter distant in the tennis court about 974 meter distant in the private hob by facility and about 528 meter distant in the library from the apartment unit The recreation center and the library are nearer facilities than the other facilities. But these facilities are surveyed to be more or less influenced by an interesting progran, a context of events and the level of useful facilities, etc.

  • PDF

Fabrication and Pulse-echo Response of Level-Meter for Underwater (수중용 레벨메터의 제작 및 펄스-에코 특성)

  • Yang, Y.S.;Kim, C.H.;SaGong, G.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.935-937
    • /
    • 1999
  • In this study, 1-3 type composite specimens were fabricated with PZT powders prepared by the molten-salt synthesis method and Eccogel polymer matrix. A virtual level-meter was fabricated with a 1-3 type composite probe and electronic unit for underwater application. There was no difference in values between a virtual and measured level on its level meter.

  • PDF

Experiment for Position Accuracy Using Laser Scale Unit with 10 Nano-Meter Resoultion (10 nano-meter 분해능을 갖는 laser scale을 이용한 위치 결정 실험)

  • 임선종;정광조;최재완
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.21-26
    • /
    • 2000
  • This paper describes a positioning system for ultra-precision that will be utilized in semiconductor manufacturing field and precision machinery. This system is composed with laser scale unit with 10nm resolution, ball screw with LM guide, brushless DC servo motor, vibration isolator and is equipped in chamber for continuous measuring environment. The dynamic of table, the problem of servo control and the traceability for micro step motion are described. These data will be applied for getting more stable system with 50nm resolution.

  • PDF