• 제목/요약/키워드: meter data

검색결과 842건 처리시간 0.028초

개인용 혈당측정기의 신뢰성 보증시험 개발 (Development of Reliability Demonstration Test for Personal Blood Glucose Meters)

  • 김기영;박호준;박찬수;함중걸;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제13권4호
    • /
    • pp.299-307
    • /
    • 2013
  • The value of blood sugar is measured by a personal blood glucose meter which consists of two parts: a glucose strip and a blood glucose meter. A personal blood glucose meter makes use of electric media which are composed of glucose oxidase and electron. This study is to propose a method of reliability demonstration test derived from field data analysis and FMEA(Failure Mode and Effect Analysis). Detailed Conditions for reliability demonstration test are selected from the comparison of various failure mechanisms. The most dominant failure mechanism is wear-out which is caused by strip insertion/extraction. The testing device that can reproduce the failure mechanism of strip insertion/extraction is made to conduct reliability demonstration test. Using the testing device, it is confirmed that target lifetime of selected devices is more than 2 years.

공저변형법에 의한 3차원응력측정 시스템의 개발 (Development of 3-Dimensional Stress Measurement System by Bore hole Bottom Deformation Method)

  • 이기하
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.34-41
    • /
    • 2006
  • A 3-dimensional stress measurement system based on the bore hole bottom deformation method, which is one of the stress relief methods, was developed. A pilot bore hole is drilled from the bottom of a bore hole and the stress meter is inserted into the pilot bore hole in the method. The bore hole is advanced as an over coring and the deformations in seven directions are measured by cantilever type-sensors. Using the cantilever type-sensors saves time for hardening of glue. No cable connection between the stress meter and a data logger is necessary since a compact data logger is installed in the stress meter. The accuracy of the stress meter was confirmed by a biaxial test for a Shikotsu welded tuff block although in-situ tests have not been carried out yet.

  • PDF

다중채널 클러스터 기반의 AMI 네트워크 설계 (Design of Advanced Metering Infrastructure Network Based on Multi-Channel Cluster)

  • 최석준;심병섭;채수권
    • 한국통신학회논문지
    • /
    • 제38B권3호
    • /
    • pp.207-215
    • /
    • 2013
  • 본 논문은 효율적인 무선 AMI 네트워크를 위한 채널 할당 및 스케줄링 기법에 관한 것이다. AMI 시스템에서, 제안하는 다중채널 클러스터 네트워크는 NC(Network Coordinator)와 CDA(Clustered Data Aggregator) 간의 통신 채널을 네트워크 채널로 정의 하고, CDA와 OMD(Out Meter Display), SMD(Smart Meter Device) 간의 통신채널을 그룹 채널로 정의한다. 네트워크 채널과 그룹채널이 혼합된 다중채널 클러스터 기반의 AMI 네트워크는 물리적/논리적 수용가 채널 클러스터링을 통해서 관리의 효율성을 증대하고, 인접 클러스터간 구별되는 채널 사용을 통한 검침 데이터의 신뢰성을 증대한다. 또한 다중채널 클러스터 기반의 채널할당을 통하여 데이터의 빠른 수집이 가능하며 검침망의 크기를 증가시킨다.

유량측정 오차에 미치는 유동조건의 영 향 검출방법 연구 (An Identification Method of the Influence of Flow Conditions on the Flow Metering Error)

  • 이광복;최해만;백종승
    • 설비공학논문집
    • /
    • 제3권1호
    • /
    • pp.34-41
    • /
    • 1991
  • The effect of flow conditions on flow measurement is difficult to identify from the inherent characteristics of the flowmeters and flow standard system. A new experimental approach has been attempted to detect the turbine meter error due to inlet flow conditions. In this try not only the design of the turbine meter package but also the data analysis method was altered. It was found that k factor slope of the turbine meter responds to the change of flow conditions in the test line with higher sensitivity than the degree of the data scattering. The flow standard system of $0.1m^3/s$ was chosen for the investigation. The systematic and random error of the system were less than ${\pm}0.08%$ and ${\pm}0.13%$ respectively.

  • PDF

PcMeter를 이용한 인터넷 접속을 측정 (Korean internet audience centric measurement : Internet index)

  • 이상경
    • 한국조사연구학회지:조사연구
    • /
    • 제1권1호
    • /
    • pp.125-134
    • /
    • 2000
  • 인터넷 리서치의 과학성을 담보하기 위해서는 과학적 원칙과 절차를 지켜야 한다. 그 핵심은 표본추출에 있으며, 특히 자기선택오류를 범하지 않기 위한 방안이 모색되어야 한다. 먼저 인터넷센서스를 통해 네티즌의 분포와 변화상황를 주기적으로 체크하고 그에 준한 표본추출을 실시하여 패널을 구축한다. 구축된 패널에 PcMeter 를 장착케 하여 전송된 로그를 분석하여 제시하는 이를 인터넷 인덱스라한다.

  • PDF

AMI 운영을 위한 MDMS 설계 연구 (A Study on Design of Meter Data Management System for Operation of AMI)

  • 정남준;김동욱;송재주;채창훈
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2012년도 춘계학술발표대회
    • /
    • pp.208-211
    • /
    • 2012
  • 전력시스템에서 MDMS(Meter Data Management System)는 HAN(Home Area Network)과 Smart Meter, SUN(Smart energy Utility Network)와 같은 AMI(Advanced Metering Infrastructure) 기반 환경에서 수많은 전력 또는 수도 가스 사용량과 같은 데이터를 수집, 취득하고, 이들 데이터를 처리, 가공, 분석하여 가치 있는 정보로 변환시켜, 요금서비스 및 다양한 부가서비스 창출에 활용되는 소프트웨어 인프라이다. 최근 MDMS 개발은 기능의 중요성 뿐만 아니라 다른 응용 시스템들과의 상호 운용성을 고려하여 개발하는 요구 기능을 가진다. 본 논문에서는 스마트그리드 환경에 적합한 AMI의 전력처리시스템(MDMS) 개발을 위한 설계 방안을 기술하였다.

고정밀 전력미터의 개발과 신뢰성 확보 방안에 대한 연구 (A Study on the High-Accuracy Power Meter and Reliability Verification Plan)

  • 이상훈;이창화
    • 한국멀티미디어학회논문지
    • /
    • 제20권7호
    • /
    • pp.1046-1053
    • /
    • 2017
  • We propose a design method of high accuracy power measuring device and the method of securing the reliability of the measured data. As a design method for the development of the high accuracy power measuring device, the circuit was made by reflecting the high accuracy power measuring ICs and the CT (Current Transformer). To ensure the reliability of the power meter, we requested to the watt-hour meter certified testing organization to measure the error rate, and the error rate of active power based on the "Wattmeter Technical Standard(Revision notify 2014-283)" was measure, and the error rate was confirmed to be less than 0.1%.

RTDS를 이용한 Digital 적산전력량계의 성능 평가연구 (Performance Evaluation Study of Digital Watthour Meter using RTDS)

  • 강민규;박석훈;김우현;성기철;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.163-165
    • /
    • 1999
  • This work presents the performance characteristic of digital watthour meter under the harmonics of voltage and current. Each waveform involved is different in magnitude phase, and THD(Total Harmonic Distortion). It is possible to generate harmonics and control those waveforms using RTDS(Real Time Digital Simulator). Tests were performed on a selected sample of three-phase digital watthour meter which is coupled with data acquisition system via RS 485/232 converter. The percentage error rate of the watthour meter is compared for both sinusoidal and nonsinusoidal cases and the results are given.

  • PDF

자동차(自動車) 번호표(番號標)(보통 번호표(番號標)) 숫자(數字)의 가독성(可讀性)에 대한 연구(硏究) (A Study on the Readability of the Car License Plate in Korea)

  • 백승엽;조암
    • 대한인간공학회지
    • /
    • 제7권1호
    • /
    • pp.13-20
    • /
    • 1988
  • The purpose of this study is to provide basic research data on the readability of the car number license plate in Korea by experimental procedure. This study is performed by the combination of color contrasts, character forms, and stroke widths. Additionally it is focused on the distance of distinct vision and misreading rate. The results of the this study are as follows: First, as to the color contrasts, the plate which has black on yellow contrast has better readability than current contrast between white and green (white character on green plate, vice versa). Second, as the character forms, it is showed that Quasigothic and NAMEL types have less misreading rates by 42.86% and 42.15%, respectively, than current Gothic type, and they also increase distance of distant vision by 4 meter. Third, as to the stroke widths, it is showed that 12 milli-meter and 14 milli-meter of stroke widths have less misreading rates by 63.94% and 65.33 %, respectively, than current 6 milli-meter of stroke width.

  • PDF

A Case Study on Energy focused Smart City, London of the UK: Based on the Framework of 'Business Model Innovation'

  • Song, Minzheong
    • International journal of advanced smart convergence
    • /
    • 제9권2호
    • /
    • pp.8-19
    • /
    • 2020
  • We see an energy fucused smart city evolution of the UK along with the project of "Smart London Plan (SLP)." A theoretical logic of business model innovation has been discussed and a research framework of evolving energy focused smart city is formulated. The starting point is the silo system. In the second stage, the private investment in smart meters establishes a basement for next stages. As results, the UK's smart energy sector has evolved from smart meter installation through smart grid to new business models such as water-energy nexus and microgrid. Before smart meter installation of the government, the electricity system was centralized. However, after consumer engagement plan has been set to make them understand benefits that they can secure through smart meters, the customer behavior has been changed. The data analytics firm enables greater understanding of consumer behavior and it helps energy industry to be smart via controlling, securing and using that data to improve the energy system. In the third stage, distribution network operators (DNOs)' access to smart meter data has been allowed and the segmentation starts. In the fourth stage, with collaboration of Ofwat and Ofgem, it is possible to eliminate unnecessary duplication of works and reduce interest conflict between water and electricity. In the fifth stage, smart meter and grid has been integrated as an "adaptive" system and a transition from DNO to DSO is accomplished for the integrated operation. Microgrid is a prototype for an "adaptive" smart grid. Previous steps enable London to accomplish a platform leadership to support the increasing electrification of the heating and transport sector and smart home.