• 제목/요약/키워드: meter data

검색결과 842건 처리시간 0.029초

상수도 자동 검침 시스템 구축에 관한 연구 : 부산 기장군과 김해시 사례를 중심으로 (Automatic Meter Reading System for Water-Supply)

  • 서창갑;박영재
    • 디지털융복합연구
    • /
    • 제7권3호
    • /
    • pp.103-111
    • /
    • 2009
  • In this paper, we introduce automatic meter reading system for tap water. The system is composed of automatic meter, router using RF and CDMA network, and data server. This system will easily extend to fire detect, gas, and electric charge meter system. In addition, this system will be used to monitoring a water leak and human which live in solitude. Proposed system is installed at Gimhae-City and Gijang-gun. As a result of the automatic meter reading system for tap water, The leak of water and complain of user is decreased. But The building cost is still an obstacle to expand into entire city.

  • PDF

ANSI C12.22 국제 통신 프로토콜이 적용된 스마트미터 개발 (Development of a Smart meter Applying the ANSI C12.22 International Communication Protocols)

  • 이상일
    • 한국정보통신학회논문지
    • /
    • 제17권12호
    • /
    • pp.2952-2959
    • /
    • 2013
  • 본 논문에서는 국제 통신 프로토콜이 적용된 스마트미터를 개발하였다. 스마트미터는 전력 공급 사업자와의 데이터 교환을 위해 양방향 통신 및 제어 기술, 전기 기기의 등록 및 해제를 위한 통신 프로토콜이 요구된다. 스마트미터의 통신 프로토콜은 미국과 유럽을 중심으로 표준화가 진행되고 있으며, 본 논문에서 제안하는 스마트미터의 통신 프로토콜은 북미방식인 ANSI C12.22 표준을 채택하여 적용하였다. 스마트미터는 또한 전력 사용자에게도 실시간으로 소비 전력 정보와 요금 정보를 제공해야 하며, 사용자는 이 정보를 바탕으로 적절하게 수요반응을 할 수 있어야한다. 본 논문에서는 스마트미터에서 측정되는 전력량이 실시간으로 사용자에게도 보고될 수 있도록 하였으며, IHD(In Home Display)를 윈도우즈 소프트웨어로 구현하여 개발된 스마트미터와의 연동을 실현하였다.

Binary CDMA 기술을 이용한 무선 원격검침 시스템 구현 (Implementation of Wireless AMR System using Binary CDMA)

  • 권대길;조진웅;홍대기
    • 반도체디스플레이기술학회지
    • /
    • 제12권4호
    • /
    • pp.1-7
    • /
    • 2013
  • This paper presents the AMR (Automatic Meter Reading) system using the binary CDMA (Code Division Multiple Access) radio technology. The binary CDMA is the new radio technology in domestic research. Main implementation topics includes the binary CDMA remote meter reading system, the wireless piconet configuration for the wireless automatic meter reading, and the transmission scheduling for sending and receiving data. Also, the wireless packet data encryption is very important topics for the wireless automatic meter reading. The proposed AMR system is implemented as a pilot project in Jeju and Gangwon. It can be seen that the wireless remote reading using the binary CDMA wireless technology can be applied to the AMR system.

KNIME 분석 플랫폼 기반 스마트 미터 빅 데이터 클러스터링 (Clustering of Smart Meter Big Data Based on KNIME Analytic Platform)

  • 김용길;문경일
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권2호
    • /
    • pp.13-20
    • /
    • 2020
  • 빅 데이터 관련 주요 논제 중의 하나는 방대한 시간 기반 또는 원격 측정 데이터의 가용성에 관한 문제이다. 현재 저비용 획득 및 저장 장치의 등장은 더 세밀한 분석에 사용될 상세한 시간 데이터를 얻을 수 있어서 배후 시스템에 대해 여러 가지 지식을 갖거나 미래의 이벤트를 더 정확히 예측할 수 있다. 특히, 스마트 미터가 설치된 수많은 가정 및 기업 등을 대상으로 전기 사용에 관한 고객 맞춤형 계약을 정의하는 것은 다른 무엇보다도 중요한 문제이다. 수많은 스마트 미터 데이터를 바탕으로 공통적인 전력 소비 형태를 몇 가지 그룹으로 구분할 필요가 있다. 이에 본 연구에서는 스마트 미터 측정 관련 공개 데이터와 자바 기반 공개 소스인 KNIME 플랫폼을 사용하여 스마트 미터 관련 빅 데이터 변환과 클러스터링을 나타낸다. 빅 데이터 구성 요소는 공개 소스는 아니지만, 시험판으로 사용할 수 있다. 스마트 미터 빅 데이터를 가져오고, 정리하고, 변환한 후 전력 사용량 행위와 관련된 각 미터 ID의 해석과 클러스터링에 적합한 DTW 접근 방식을 통해 전력 사용 행위에 관한 스마트 계약을 정의할 수 있다.

상수도 원격 검침 데이터 송수신 위한 Client/Server 소켓 프로그램 개발 (Development of a Client/Server Socket Program using Remote Measurement of Digital Water Meters)

  • ;박용만;권종원;김희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.153-155
    • /
    • 2006
  • An automatic remote water measurement system was developed. This system sends automatic remote measured and collected water meters data automatically from the transmitter with CDMA modem through SK-Telecom network The water meter data are received through LAH TCP/IP and displayed as test file on IE(Internet Explorer) window. The existing water meters of mechanical type have so many problems to measure data. The person must visit the location of each water meters and write down the data records manually. In this system the RF module has attached each water meter Client/Server programs are developed by network socket programming.

  • PDF

차세대 디지털 적산전력계 개발에 대한 연구 (A Study on the Development of ADWHM(Advanced Digital Watt-Hour Meter))

  • 고윤석;윤상문;서성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.262-264
    • /
    • 2003
  • This paper develops an ADWHM(Advanced Digital Watt Hour Meter) based on RISK type'8bit micro-controller, which has voltage management data recording function, load management data recording function as well as the existing watt-hour data recording data function. It can enhance greatly the economics of the existing remote meter reading system. Also it can improve highly the quality of power supplied to the electric customer by minimizing the voltage management cost and by enhancing the efficiency of load management.

  • PDF

주유기 유량 변조방지를 위한 주유기 엔코더 신호 펄스 파형 모니터링 및 정량확인 시스템 개발 (Development of monitoring system and quantitative confirmation device technology to prevent counterfeiting and falsification of meters)

  • 박규백;이정우;임동욱;김지훈;박정래;하석재
    • Design & Manufacturing
    • /
    • 제16권1호
    • /
    • pp.55-61
    • /
    • 2022
  • As meters become digital and smart, energy data such as electricity, gas, heat, and water can be accurately and efficiently measured with a smart meter, providing consumers with data on energy used, so that real-time demand response and energy management services can be utilized. Although it is developing from a simple metering system to a smart metering industry to create a high value-added industry fused with ICT, illegal counterfeiting of electronic meters is causing problems in intelligent crimes such as manipulation and hacking of SW. The meter not only allows forgery of the meter data through arbitrary manipulation of the SW, but also leaves a fatal error in the metering performance, so that the OIML requires the validation of the SW from the authorized institution. In order to solve this problem, a quantitative confirmation device was developed in order to eradicate the act of cheating the fuel oil quantity through encoder pulse operation and program modulation, etc. In order to prevent the act of deceiving the lubricator, a device capable of checking pulse forgery was developed, manufactured, and verified. In addition, the performance of the device was verified by conducting an experiment on the meter being used in the actual field. It is judged that the developed quantitative confirmation device can be applied to other flow meters other than lubricators, and in this case, accurate measurement can be induced.

빅데이터 기반 인공지능 동파위험 정보서비스 개발을 위한 연구 (A Study on the development of big data-based AI water meter freeze and burst risk information service)

  • 이진욱;김성훈;이민재
    • 한국건설관리학회논문집
    • /
    • 제24권3호
    • /
    • pp.42-51
    • /
    • 2023
  • 겨울철 동파는 물사용 불가, 2차 피해 및 계량기 교체비용 발생 등 많은 사회적 비용을 발생시키고 있다. 정부에서는 지방상수도 시설의 현대화를 위해 많은 노력을 기울이고 있으며, 특히나 전국적으로 SWM 사업을 추진 중에 있다. 본 연구에서는 수용가의 최접점에 설치되는 스마트 미터링에 착안하여 기존의 대기온도가 아닌 계량기 함내 온도를 기반으로 하는 새로운 동파위험 알림 정보서비스를 계획하였다. 또한 본 연구에서는 전국적으로 설치된 스마트미터의 수량적인 한계를 극복하기 위하여, 온도센서로부터 취득된 자료들을 바탕으로 물리적인 온도센서가 없는 지역의 온도를 예측하는 인공지능 기반의 온도예측 모델을 개발하였고, 최적화 과정을 통해 전국을 대상으로 하는 수도계량기 동파위험 정보서비스(안)을 구상하였다.

스마트카드 기반의 전력원격검침 프레임워크 (Smart Card based Framework for Electricity AMR)

  • 강환수
    • 한국콘텐츠학회논문지
    • /
    • 제9권7호
    • /
    • pp.121-129
    • /
    • 2009
  • 전력검침은 전력 사용요금을 부과하기 위하여 전력사용량을 측정하는 행위를 말하며, 이를 자동화한 시스템을 전력원격검침(AMR: Automatic Meter Reading)이라 한다. 전력원격검침은 검침 인력을 시스템으로 대체해 원가를 줄이고 고객 서비스를 강화할 수 있는 시스템으로 부각되고 있다. 본 논문에서는 기존의 전력원격검침 모델의 대안으로 스마트카드 기반의 전력원격검침 프레임워크 SCEMS를 제안하고 구현하였다. 제안된 SCEMS 프레임워크는 자바카드 기반의 다기능 스마트카드를 사용하며, 스마트카드에 수집된 자료와 가구의 전력사용 패턴을 활용하여 다양한 요금제를 지원하는 등의 고객서비스를 제공한다. 제안된 원격검침 모델 연구는 전력산업의 환경변화에서 초래할 다원화, 이질화, 복합화에 대한 해결방안이 될 수 있을 것으로 보인다.

세대집중화장치를 포함하는 스마트 전력량계를 이용한 AMI 시스템 (AMI System Using Smart Electricity Meter Embedded with Home Concentrate Unit)

  • 박재삼
    • 한국전자통신학회논문지
    • /
    • 제14권3호
    • /
    • pp.537-546
    • /
    • 2019
  • 본 논문에서는 스마트 전력량계에 세대집중화장치를 내장하여 AMI에 필요한 가스, 수도, 온수, 난방 검침을 일괄검침하는 시스템과, 검침데이터를 에너지정보표시장치(IHD: In House Display)와 서버로 전송하는 방법을 구성하여 보다 경제적으로 AMI 시스템을 구축하는 방법을 제시한다. 개발된 시스템은 기존 시스템 보다 네트워크 구성에 있어서 가격이 저렴하고 운영비용이 절감되며 설치가 용이하다. 개발된 시스템을 적용하면 전기, 수도, 가스, 온수 및 난방의 5종 계량기의 계량값을 원격검침 하고 이에 대한 AMI 적용을 보다 용이하게 구성 가능하다. 주요개발 내용은 스마트 전력량계 구성과 세대집중화장치 결합 및 이들 데이터를 IHD와 서버로 전송하는 방법이며, 이들 요소들을 연계하여 시스템을 구성하고 실제 검침 동작구성을 테스트하고 그 결과를 보여준다.