• Title/Summary/Keyword: meter

Search Result 3,744, Processing Time 0.029 seconds

A Study on the Needed Function of Low Voltage Solid State Meter Considering Electricity Tariff Policy (요금정책을 고려한 저압용 전자식 전력량계의 필요기능에 관한 연구)

  • Kim, Jae-Sung;Lee, Tae-Hyung;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.800-802
    • /
    • 1999
  • The meters for low voltage customer presently being used in Korea are all mechanical type and there is strict limitation on applying various customized tariff structure. Recently low voltage solid state meter is under development by several makers of the watt hour meter in Korea. Also, KEPCO has a plan to use the solid state meter for low voltage customer to reduce peak power. So, this paper suggests the needed function of low voltage solid state meter considering electricity tariff policy.

  • PDF

The Evaluation of Dynamic Load for the Cone Type Venturi Flow meter (원추형 벤튜리 유량계에 관한 동하중 평가)

  • 김중권;장경영;조남오
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.140-144
    • /
    • 1997
  • Although the cone type venturi flow meter is superior to another differential pressure type flow meter in precision, the venturi is installed at the pipe as an L beam, so that the dynamic load due to drag force and flow-induced force is generated in the flow meter. In this paper we propose a methodology to evaluate this dynamic load directly by using stain-gages attached on the venturi and we discuss about the dynamic characteristics on the basis of flow-induced vibration theory.

  • PDF

IMPLEMENTATION OF DIGITAL POWER METER USING TMS320C5X

  • Ku, Bon-Hyouk;Chok, Myung-Ryul
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.575-580
    • /
    • 1998
  • A power meter is an instrument for measuring in watts the power flowing in a electric equipment. Since the value which a conventional power meter measures is analog, the power meter is hard to determine a phase difference between the voltage and current for a inductive load. The phase difference causes a loss of electric power and a increase of power-line load. In this paper, we propose a digital power meter using TI's DSP(Digital Singnal Processor) TMS320C5x, which is employed to calculate the phase difference and more accurate power consumption.

  • PDF

Study on the High Sensitive Three Phase Power Factor Meter and Relay (고감도 삼상력률계전기에 관한 연구)

  • 박정후
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.16 no.1
    • /
    • pp.43-47
    • /
    • 1980
  • The author designed and tested the high sensitive three-phase power factor meter and relay circuit, and dealt with the circuit to detect the phase of the current and the voltage. An operational amplifier comparator circuit and two single-phase transformers are used to control and detect the phase angle between the current and the voltage. The results obtained are as follows: 1. Converting the sine wave input current into the constant amplitude rectangular wave form by using a transistor chopper circuit, the power factor can be measured precisely over the load current of 0.08 A. 2. Using the moving coil type current meter, the power factor meter can be read in uniform . scale all over the range. 3. Using the three-phase power factor meter, the power factor relay which works at any power factor can be made.

  • PDF

Present Situation and Prospects for the Solid State Meter Considering Electricity Tariff Policy (전자식전력량계의 도입현황과 요금구조의 장기방향을 고려한 발전전망)

  • Kwon, O-Hyung;Kim, Jae-Sung;Jo, Jin-Sub
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.760-762
    • /
    • 1998
  • Due to the reinforcement of government's DSM(Demand Side Management) policy. Solid State Meter was introduced in Korea since 1993 and it is applied to the high voltage customer exceeding 100kW in order to equalize daily load curve. In recent days, KEPCO has a Plan to use the Solid State Meter which has a data recording and remote meter-reading function for low voltage customer to introduce the real-time pricing system and reduce peak power in the near future. So, this paper suggests the specification and function of Solid State Meter.

  • PDF

The Study on the Automated Meter Reading using Low Voltage Power (저압 배전선 반송 방식의 원격검침 실증 연구)

  • Park, Sang-Man;Ha, Bok-Nam;Lee, Joong-Ho;Cho, Nam-Hun;Kim, Myong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.985-987
    • /
    • 1997
  • AMR(Automated Meter Reading) has been considered to solve the lack of meter mem caused by the rise of cost, inefficiency of manual meter reading. Demand forecasting and efficient management of facilities can be accomplished by increasing meter reading efficiency and correcting various data. In this paper, we introduce AMR system using LV PLC in KANG-DONG blanch office of KEPCO.

  • PDF

Characteristics on the Harmonic Sensitivity of an Induction Watthour Meter (유도형 적산전력량계의 고조파 민감도 특성)

  • Jang, Seok-Myeong;Lee, Seong-Ho;Park, Yeong-Tae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.587-596
    • /
    • 1999
  • The use of Switching elements in power systems causes the current or voltage to involve harmonic waves. Harmonics bring about registration errors of the equipment for measuring power. In case the induction watthour meter designed on sinusoidal source is used in the measurement of power with harmonics, the precise measurement of power has many problems because harmonics cause a decrease of power factor and vibration by the unstable driving force on the aluminum disc. In this paper, analysis and test results on the harmonic sensitivity of an induction watthour meter is reported when the input voltage and current with harmonics were supplied to single-phase watthour meter.

  • PDF

Remote gas meter-reading system using magnetic sensor (자계 센서를 이용한 원격 가스 검침 시스템)

  • Koo, JaYl
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.2
    • /
    • pp.90-94
    • /
    • 2002
  • This paper is related to remote meter-reading using magnetic sensor. Scan system which is developed recently has week point of temperature, humidity, dust, oscillation To solve these problems, this study used magnetic action to measure the consumption of gas. Gas consumption was detected by interaction of a permanent magnet and hall element. Permanent magnet was pasted on rolling change-gear in normal gas meter and hall sensor was pasted on the external wall of normal gas meter. This experiment proved high accuracy and wasn't influenced by temperature, humidity, oscillation and dust

Calcu;ation of Groundwater Inflow Rates with respect to the Subusection of Tunnel: Application of the Current Meter (터널내 구간별 지하수 유입량 산정방법 : 유속계의 이용)

  • 조병욱
    • Economic and Environmental Geology
    • /
    • v.32 no.6
    • /
    • pp.661-667
    • /
    • 1999
  • Estimation of inflow rates into subsection of a tunnel is establishing the proposed grouting part, measuring the degree of grouting, and settling the dispute over deplrtion of groundwater which may be resulted from tunneling. A current meter was used to calculate inflow rates of groundwater to each subsection of the tunnel. The study area is composed of section 1 and 2 of Imha-Youngchun waterway trnnel which has 32.976km length, with each section having 3,745m and 4,079m, respectively. The depth from groung surface to tunnel ranges from 122.45m to 358.3m. Total inflow rates of groundwater into each section measured three times by the current meter, together with bottle and eye measurement, were compared with groundwater inflow rates of each section measured by datalogger. The calcuated inflow rates of the sections by bottle and eye measurement were 8.8%∼54.7% of inflow rate (averaging 27,4%), whwewas those by the current meter were 76.9%∼110.6%(averaging 92.9%). Therfore, the current meter is regarded as useful method to calculate groundwater inflow rates into subsections of a tunnel.

  • PDF

On-line Measurement of Oil Consumption Using Oil Consumption Meter (오일소모 측정센서를 이용한 오일소모량의 실시간 측정)

  • 김기대;이재곤
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.688-694
    • /
    • 2002
  • Several methods were developed for on-line measuring oil consumption in gasoline engine using an oil consumption meter. The oil consumption meter indicates the oil quantity by real-time-measuring the oil level in the sump. In order to measure the oil consumption, the oil consumption meter proposed in this paper requires shorter time, less additional procedures, and shows better results than the traditional drain method. Under steady-state engine-operating conditions, the results obtained through the regression or the difference method show an good agreement with those through the drain method. Under transient engine-operating conditions, on the other hand, good results can be obtained through the reference method.