• Title/Summary/Keyword: metal waste

Search Result 918, Processing Time 0.034 seconds

A Study on the Scale-up of Highly Effective Copper Metal Recovery from Waste Jelly-filled Communication Cables (폐 젤리충진 통신케이블로부터 고순도 구리회수를 위한 대형화 방안 연구)

  • Cho, Sungsu;Lee, Sooyoung;Seo, Minhye;Uhm, Sunghyun
    • Applied Chemistry for Engineering
    • /
    • v.25 no.2
    • /
    • pp.157-160
    • /
    • 2014
  • We examined and compared the feasibility of vegetable oils with synthetic thermal conductive oils to recover highly purified copper metal from waste jelly-filled communication cables. While polydimethylsiloxane shows relatively poor separation efficiency under entire operating conditions, dibenzyltoluene and waste vegetable oil show the high separation efficiency if the appropriate operating temperature and time were given. By running 50 kg-class equipment with waste vegetable oils, we obtained 100% copper metal recovery with 99.2% purity at $300^{\circ}C$ for 60 min.

Status Analysis for the Confinement Monitoring Technology of PWR Spent Nuclear Fuel Dry Storage System (경수로 사용후핵연료 건식저장시스템의 격납감시 기술현황 분석)

  • Baeg, Chang-Yeal;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.1
    • /
    • pp.35-44
    • /
    • 2016
  • Leading national R&D project to design a PWR spent nuclear fuel interim dry storage system that has been under development since mid-2009, which consists of a dual purpose metal cask and concrete storage cask. To ensure the safe operation of dry storage systems in foreign countries, major confinement monitoring techniques currently consist of pressure and temperature measurement. In the case of a dual purpose metal cask, a pressure sensor is installed in the interspace of bolted double lid(primary and secondary lid) in order to measure pressure. A concrete storage cask is a canister based system made of double/redundant welded lid to ensure confinement integrity. For this reason, confinement monitoring method is real time temperature measurement by thermocouple placed in the air flow(air intake and exit) of the concrete structure(over pack and module). The use of various monitoring technologies and operating experiences for the interim dry storage system over the last decades in foreign countries were analyzed. On the basis of the analysis above, development of the confinement monitoring technology that can be used optimally in our system will be available in the near future.

Thermal Shock Durability Test of a Gasoline Turbocharger Waste Gate Valve Assembly Manufactured by a Metal Injection Molding (금속분말사출성형공법을 이용한 가솔린 터보차저의 웨이스트 게이트 밸브 어셈블리 열 충격 내구 시험)

  • Nam, Chungwoo;Han, Manbae;Chun, Bongsu;Shin, Jaesik;Kim, Jongha;Min, Doosik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.4
    • /
    • pp.69-74
    • /
    • 2014
  • A waste gate valve (WGV) assembly for a gasoline turbocharger is typically manufactured by means of precision casting. In this study, however, it was newly manufactured in a more innovative way, metal injection molding (MIM) using Inconel 713C alloy, and its performance was tested in a 1.6L direct injection gasoline engine by a thermal shock durability test that lasted 300 hours, after which the results were compared to those of a precision-cast WGV assembly with regard to the engine intake boost pressure, turbine wheel speed, and transient intake pressure. It was found that the two WGV assemblies showed similar performance levels throughout the durability test.

Behavior of Radioactive Metal Surrogates Under Various Waste Combustion Conditions

  • Yang, Hee-Chul;Lee, Jae-Hee;Kim, Jung-Guk;Yoo, Jae-Hyung;Kim, Joo-Hyung
    • Nuclear Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.80-89
    • /
    • 2002
  • A laboratory investigation of the behavior of radioactive metals under the various waste combustion atmospheres was conducted to predict the parameters that influence their partitioning behavior during waste incineration. Neodymium, samarium, cerium, gadolinium, cesium and cobalt were used as non-radioactive surrogate metals that are representative of uranium, plutonium, americium, curium, radioactive cesium, and radioactive cobalt, respectively. Except for cesium, all of the investigated surrogate metal compounds converted into each of their stable oxides at medium temperatures from 400 to 90$0^{\circ}C$, under oxygen- deficient and oxygen-sufficient atmospheres (0.001-atm and 0.21-atm $O_2$). At high temperatures above 1,40$0^{\circ}C$, cerium, neodymium and samarium in the form of their oxides started to vaporize but the vaporization rates were very slow up to 150$0^{\circ}C$ . Inorganic chlorine (NaCl) as well as organic chlorine (PVC) did not impact the volatility of investigated Nd$_2$O$_3$, CoO and Cs$_2$O. The results of laboratory investigations suggested that the combustion chamber operating parameters affecting the entrainment of particulate and filtration equipment operating parameters affecting particle collection efficiency be the governing parameters of alpha radionuclides partitioning during waste incineration.

The Adsorption Properties of Heavy Metal Ions on to Cotton Fabrics Treated with Reactive Anionic Agent (반응형 음이온화제 처리 면직물에 대한 중금속 이온의 흡착특성)

  • Kim Mi-Kyung;Yoon Seok-Han;Kim Tae-Kyeong;Lim Yong-Jin
    • Textile Coloration and Finishing
    • /
    • v.17 no.1
    • /
    • pp.20-29
    • /
    • 2005
  • Cotton fabric was treated with a reactive anionic agent in order to have anionic sites(-S03-) on it, which made it possible for the fabric to adsorb various cationic materials. In this study, the adsorptivity of various heavy metal ions such as Pb(II), Cd(II), Cr(III), Co(II), Cu(II), Ni (II) and Cr(VI) on the cotton fabrics treated with anionic agent was examined at the various conditions; concentrations of heavy metal ions, pHs of solution, reaction time and temperature. As a result, the adsorptivity of the heavy metal ions on the cotton fabrics treated with the anionic agent was highly increased comparing to that of untreated cotton fabrics. The order of the adsorptivity was as follows: $Pb(II)>Cd(II)>Cu(II)\geqNi(II)\geqCo(II)>Cr(III)\ggCr(VI)$. The adsorption amounts of most heavy metal ions were increased in weak alkaline conditions and were reached to an adsorption equilibrium within 10 ~ 30 minutes. The maximum adsorption ratios of Pb(II) and Cd(II) were respectively 99% and 80% of the initial concentration of heavy metal ions. Therefore the anionized cotton fabrics seem to be utilized as an adsorption fabrics for the removal of heavy metal ions in the waste water.

The Leaching of Valuable Metal from Mine Waste Rock by the Adaptation Effect and the Direct Oxidation with Indigenous Bacteria (토착박테리아의 중금속 적응효과와 직접산화작용에 의한 폐광석으로부터 유용금속 용출)

  • Kim, Bong-Ju;Cho, Kang-Hee;Choi, Nag-Choul;Park, Cheon-Young
    • Journal of the Mineralogical Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.209-220
    • /
    • 2015
  • The aim of this study was leaching valuable metal ions from mine waste rocks which were abandoned mine site using indigenous aerobic bacteria. In order to tolerate the the indigenous aerobic bacteria to the heavy metal ions they were repeatedly adapted in $CuSO_4{\cdot}5H_2O$ environment. As the repeated generation-adaptation progressed, the pH values of the growth-medium were gradually decreased. During bio-leaching experiments with indigenous aerobic bacteria raised in a heavy metal ion environment for 42 days, the pH of the leaching solution was decreased while increasing the adaptation period. The indigeous bacteria were much more active on the surface of Younhwa waste rocks which contained relatively few the chalcopyrite and Cu content than the Goseong mine waste rocks, and also the amount of Cu and Fe ions were leached more in the Younhwa sample(leaching rate of 92.79% and 55.88%, respectively) than the Goseong sample(leaching rate of 66.77% and 21.83%, respectively). Accordingly, it is confirmed that valuable metal ions can be leached from the mine waste rocks, if any indigenous bacteria which inhabits a mine environment site for a long time with heavy metal ions can be used, and these bacteria can be progressively adapted in the growth-solutions containing the target heavy metals.

An Equilibrium Analysis to Determine the Speciation of Metals in the Incineration of Waste Containing Chlorine (염소를 함유한 폐기물의 소각시 생성되는 유해 중금속류 결정에 대한 화학 평형 계산)

  • ;;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.12
    • /
    • pp.3372-3381
    • /
    • 1995
  • An equilibrium analysis was carried out to determine principal species of heavy metals in waste incineration and their behaviors with variation of temperature, chlorine concentration, excess air ratio, and C/H ratio. The waste was assumed as a compound of hydrocarbon fuel, chlorine, and metals. Calculated results showed that the most important parameter to determine the principal species was temperature. Chlorine concentration also affected on mole fractions of the principal species. Generally principal species at high temperature were chlorides while there were some metals of which principal species were oxides. At low temperature mole fractions of the principal species increased, but at high temperature mole fractions of some metal species decreased. C/H ratio of the hydrocarbon fuel and excess air ratio had little effect on mole fractions of the metal species, compared to the temperature and chlorine concentration.

Preparation of ion exchanger from waste paper cup and removal characteristics of heavy metal (폐종이컵을 이용한 이온교환체 제조와 중금속제거특성)

  • 유수용;이훈용;정원진;문명준;이민규
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.993-999
    • /
    • 2002
  • Waste paper cup was sulfonated to be used as ion exchanger. Removal characteristic of copper and lead ion by prepared ion exchanger was investigated. The sulfonation was conformed by the high intensity band of $SO_3H$ group around 1100~$1160cm^{-1}$. The synthesized ion exchanger had greater removal ability for copper and lead ion than the original waste paper cup. Ion exchange system reached the final equilibrium plateau within 30min. The maximum removal capacities $q_{max}$ were calculated as 9.79mg/g fur copper and 15.95mg/g for lead, respectively. The affinity of lead based on a weight was higher than that of copper. The ion exchange phenomena appeared to follow a typical Freundlich isotherm.