• Title/Summary/Keyword: metal complex

Search Result 1,252, Processing Time 0.033 seconds

Beryllium(II) Recognition by Allosteric Effects in 1,2-Ethylenedioxybenzene Based Ditopic Receptors

  • Kim, Dong-Wan;Kim, Jung-Hwan;Hwang, Jae-Young;Choi, Myong-Yong;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2643-2647
    • /
    • 2011
  • Efficient ditopic receptor, uranyl(II) N,N'-(ethylenedioxy)benzenebis(salicylideneimine) (3) for beryllium ion has been obtained upon functionalization of 1,2-ethylenedioxybenzene (1) with a uranyl-salphen (salphen = N,N'-phenylenebis(salicylideneimine)) unit. Binding affinities of the receptor, 3 in AN-DMSO (v/v 95:5) solution have been measured for alkali and alkaline earth metal ions by conductometry comparing 1. The results showed that both monotopic 1 and ditopic receptor 3 were selective for $Be^{2+}$ ions over other cations, while especially 3 that can complex both with cations (coordinated to basic oxygen of ethylenedioxybenzene) and anions (coordinated to the Lewis acidic uranyl center) results in an increase of the stability constants by a factor of $10^{2.42}$ with respect to 1. Furthermore, the $Be^{2+}$-3 interactions are demonstrated by $^1H$ NMR experiments in highly polar solvent medium, DMSO-$d_6$. Higher selectivities were also observed for $Be^{2+}$ when the ditopic receptor, 3 was incorporated into PVC membranes and tested as ion selective electrodes at neutral pH.

Synthesis and Characterization of New Mono-N-functionalized Tetraaza Macrocyclic Nickel(II) and Copper(II) Complexes

  • Kim, Hyun-Ja;Kang, Shin-Geol
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2565-2570
    • /
    • 2011
  • The reaction of bromoacetonitrile with 3,14-dimethyl-2,6,13,17-tetraazatetracyclo[$16.4.1^{2.6}.0^{1.18}.0^{7.12}$]tricosane ($L^{10}$) containing a N-$CH_2$-N linkage produces 17-cyanomethyl-3,14-dimethyl-2,6,13,17-tetraazatetracyclo-[$16.4.1^{2.6}.0^{1.18}.0^{7.12}$]tricosane ($L^{11}$). The mono-N-functionalized macrocyclic complexes $[ML^2]^{2+}$ (M = Ni(II) or Cu(II); $L^2$ = 2-cyanomethyl-5,16-dimethyl-2,6,13,17-tetraazatricyclo[$16.4.0.0^{7.12}$]docosane) can be prepared by the reaction of $L^{11}$ with nickel(II) or copper(II) ion in acetonitrile. The N-$CH_2CN$ group attached to $[ML^2]^{2+}$ readily reacts with water or methanol to yield the corresponding complexes of $HL^3$ bearing one N-$CH_2CONH_2$ pendant arm or $L^4$ bearing one $N-CH_2C(=NH)OCH_3$ group. The $N-CH_2CONH_2$ or $N-CH_2C(=NH)OCH_3$ group of each complex is coordinated to the central metal ion. Both $[NiL^4(H_2O)]^{2+}$ and $[CuL^4]^{2+}$ are quite stable in acidic aqueous solutions, but undergo hydrolysis to yield $[Ni(HL^3)(H_2O)]^{2+}$ or $[Cu(HL^3)]^{2+}$ in basic aqueous solutions. In contrast to $[Cu(HL^3)]^{2+}$, $[Ni(HL^3) (H_2O)]^{2+}$ is readily deprotonated to form $[NiL^3 (H_2O)]^+$ ($L^3$ = a deprotonated form of $HL^3$) in basic aqueous solutions.

Voltammetric Determination of Copper(II) Using Glassy Carbon Electrodes Modified with Nafion-DTPA-Glycerol

  • Park, Chan-Ju;Park, Eun-Heui;Chung, Keun-Ho
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.177-180
    • /
    • 2003
  • A glassy carbon electrode(GCE) modified with nafion-DTPA-glycerol was used for the highly selective and sensitive determination of a trace amount of Cu$\^$2+/. Various experimental parameters, which influenced the response of nafion-DTPA-glycerol modified electrode to Cu$\^$2+/, were optimized. The copper(II) was accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface was characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry, A linear range was obtained in the concentration range 1.0${\times}$10$\^$-8/M∼1.0${\times}$10$\^$-6/M Cu(II) with 7 min preconcentration. Further, when an approximate amount of lead(II) is added to the test solution, nafion-DTPA-glycerol modified glassy carbon electrode has a dynamic range of 2 orders magnitude(1.0${\times}$10$\^$-9/M∼1.0${\times}$10$\^$-7/M). The detection limit(3 $\sigma$) was as low as 5.0${\times}$10$\^$-6/M(0.032ppb). The interferences from other metal ions could be reduced by adding KCN into the sample solutions. This method was applied to the determination of coppe,(II) in certified reference material(3.23${\times}$10$\^$-7/M, 21ppb), sea water(9.50${\times}$10/sup-7/M, 60ppb). The result agrees satisfactorily with the value measured by Korea Research Institute of Standard and Science.

  • PDF

Lead Levels in Blood of Residents in Industrial Area (일부 공단지역 주민의 혈 중 납 농도에 관한 연구)

  • Jou, Hye-Mee;Cho, Tae-Jin;Yang, Won-Ho;Lee, Jong-Wha;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.2
    • /
    • pp.86-94
    • /
    • 2009
  • This study analyzed the concentration of the lead in blood (n=774) from May, 2007 to Oct 2007. The subject was residents in G, Y, H industrial area, Jeollanam-do, in which exposure to the lead is expected due to the adjacency of the industrial complex. As to the lead concentration in the blood of the residents in the whole exposed region and the comparing region, $2.81{\mu}g/dl$ in the exposed region group, and $2.86{\mu}g/dl$ in the comparing region group Respectively, which indicates that the concentration of the comparing group was higher than that of the exposed group. The geometric mean concentration of lead in blood was $3.26{\mu}g/dl$ as to men, and $2.46{\mu}g/dl$ as to women, which indicates that the concentration of men is higher than that of women (p<0.01). The lead concentration for each age group increased in proportion to age except those under 10 for some substances (p<0.01). As to geometric mean concentration in blood according to the smoking history of the subject, the concentration of the smoking group and the non-smoking group was $3.57{\mu}g/dl$ and $2.66{\mu}g/dl$ respectively, which indicates the former is higher than the latter (p<0.01). To clarify the factors affecting the heavy metal concentration in blood among the subjects, the multiple regression analysis was conducted. As a result, it turned out that as to lead content in blood, gender, age, smoking all affect the lead concentration of the subjects ($R^2$=23.3%).

Analysis of Properties of Flake Sendust EM Wave Absorber according to Granularity (입도에 따른 Flake Sendust 전파 흡수체의 특성 분석)

  • Park, Soo-Hoon;Kim, Dong-Il;Choi, Dong-Han;Kim, Seong-Yeon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.1051-1057
    • /
    • 2008
  • In this paper, we analyzed the characteristics of the EM wave absorber which was fabricated by using flake sendust (soft metal magnetic powder). The flake sendust was made of 3 different granularity by attrition mill. First, we have fabricated 3 kind of EM wave absorbers using the flake sendust and CPE(Chlorinated Polyethylene) and measured the S-parameters of the EM wave absorber. The complex relative permittivity and permeability were calculated from the measured data and the variations according to a change of granularity were researched. As a result, it was confirmed that the EM wave absorber using flake sendust with the $140{\mu}m$ average granularity has outstanding absorption ability in high frequency range(C band) for the reduction of eddy current loss(increase of permeability) and the increase of space charge polarization(increase of permittivity).

Design of a Time-Multiplexing CNN Chip (시다중처리 셀룰러 신경망 칩설계)

  • 박병일;정금섭;전흥우;신경욱
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.2
    • /
    • pp.505-516
    • /
    • 2000
  • Cellular Neural Networks(CNN) is a nonlinear information-processing system that has a locally connected characteristic and is widely used in the real-time high speed image processing. In this paper, a practical system approach of time-multiplexing CNN implementations suitable for processing large and complex images using small CNN arrays is presented and $6\times6$ CNN hardware is designed for the processing of a large image. While previous implementations are mostly suitable for black and white applications because of the thresholded outputs, our approach is especially suitable for applications in gray image processing due to the analog nature of the state node. CNN chip is designed using a 0.65${\mu}{\textrm}{m}$ 2P2M(double poly, double metal) N-Well CMOS process technology. It contains about 15,400 devices on an area of about $1.85\times1.75$ md. The designed $6\times6$ CNN is tested for the edge detection of a large image input and it's performance is verified.

  • PDF

Purification and Characterization of a Lectin from Arisaema tortuosum Schott Having in-vitro Anticancer Activity against Human Cancer Cell Lines

  • Dhuna, Vikram;Bains, Jagmohan Singh;Kamboj, Sukhdev Singh;Singh, Jatinder;Shanmugavel;Saxena, Ajit Kumar
    • BMB Reports
    • /
    • v.38 no.5
    • /
    • pp.526-532
    • /
    • 2005
  • A lectin with in-vitro anticancer activity against established human cancer cell lines has been purified by affinity chromatography on asialofetuin-linked amino activated silica beads from the tubers of Arisaema tortuosum, popularly known as Himalayan Cobra lily, a monocot plant from the family Araceae. The bound Arisaema tortuosum lectin (ATL) was eluted with glycine-HCl buffer, pH 2.5. ATL was effectively inhibited by asialofetuin, a complex desialylated serum glycoprotein as well as by N-acetyl-D-lactosamine, a disaccharide. It gave a single band corresponding to a subunit molecular weight of 13.5 kDa in SDS-PAGE, pH 8.8 both under reducing and non reducing conditions. When subjected to gel-filtration on Biogel P-200, it was found to have a molecular weight of 54 kDa, suggesting a homotetramer structure, in which individual polypeptides are not bound to each other with disulfide bonds. ATL is a glycoprotein with 0.9% carbohydrate content, stable up to $55^{\circ}C$ and at pH 2 to 10. The lectin had no requirement for divalent metal ions i.e. $Ca^{2+}$ and $Mn^{2+}$ for its activity. However, as reported for other monocot lectins, ATL gave multiple bands in isoelectric focusing and Native PAGE, pH 8.3. The lectin was found to inhibit in vitro proliferation of human cancer cell lines HT29, SiHa and OVCAR-5.

Acoustic Metal Impact Signal Processing with Fuzzy Logic for the Monitoring of Loose Parts in Nuclear Power Plang

  • Oh, Yong-Gyun;Park, Su-Young;Rhee, Ill-Keun;Hong, Hyeong-Pyo;Han, Sang-Joon;Choi, Chan-Duk;Chun, Chong-Son
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.1E
    • /
    • pp.5-19
    • /
    • 1996
  • This paper proposes a loose part monitoring system (LPMS) design with a signal processing method based on fuzzy logic. Considering fuzzy characteristics of metallic impact waveform due to not only interferences from various types of noises in an operating nuclear power plant but also complex wave propagation paths within a monitored mechanical structure, the proposed LPMS design incorporates the comprehensive relation among impact signal features in the fuzzy rule bases for the purposes of alarm discrimination and impact diagnosis improvement. The impact signal features for the fuzzy rule bases include the rising time, the falling time, and the peak voltage values of the impact signal envelopes. Fuzzy inference results based on the fuzzy membership values of these impact signal features determine the confidence level data for each signal feature. The total integrated confidence level data is used for alarm discrimination and impact diagnosis purposes. Through the perpormance test of the proposed LPMS with mock-up structures and instrumentation facility, test results show that the system is effective in diagnosis of the loose part impact event(i.e., the evaluation of possible impacted area and degree of impact magnitude) as well as in suppressing false alarm generation.

  • PDF

Synthesis and Electrochemical Characterization of The New Luminescent Metal-Chelate Complexes (새로운 금속 킬레이트 착물 발광체의 합성과 전기화학적 특성 연구)

  • Park, Jee Young;Choi, Don Soo;Kim, Young Kwan;Ha, Yun Kyoung
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.3
    • /
    • pp.243-248
    • /
    • 2000
  • Oganic electroluminescent devices (OELD) with multilayer structures have been studied actively for the application to a flat-panel display. Netal-chelate complexes hrboxylate. These complexes were characterized by FT-IR, MS/FAB, $^1$H-NMR, UV-vis and photoluminescence (PL). More importantly, the electrochemical gap (Eg), electron affinity(EA) and ionization potential (IP) of these complex films were investigated. Data from cyclic voltammetry(CV) were compared with the bandgap obtained from UV-vis and discussed. Further studies on the EL of these new materials are now in progress.

  • PDF

Studies on Electrochemical Behavior of Some Light Lanthanide Ions in Nonaqueous Solution, Flow Injection Determination and Photochemical Characterization of Heavy Metal Ion Chelate Eight Coordinated Complexes. (Part 2) (비수용액에서 가벼운 란탄족 이온의 전기화학적 거동, 흐름 주입법에 의한 정량 및 중금속 이온의 킬레이트형 8-배위 착물의 광화학적 특성 연구 (제 2 보) : 계면활성제 존재하에서 Chromeazurol S를 사용하여 몇 가지 란탄이온의 흐름주입법에 의한 정량)

  • Gang, Sam U;Jang, Ju Hwan;Kim, Il Gwang;Han, Hong Seok;Jo, Gwang Hui
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.1
    • /
    • pp.50-54
    • /
    • 1994
  • Spectrophotometric determination of some light lanthanide ions by flow injection method is described. Chromeazurol S forms water soluble complex with lanthanide ions in the presence of DTAB. The absorption maximum of the complexes are from 650 nm to 655 nm and the molar absorptivities were ca. $1.8{\times}10^5\;L mol^{-1}cm^{-1}$ on Tris buffer (pH 10.5). The calibration curves for Nd(III), Eu(III) and Sm(III) obtained by FIA are over the range of 0.1 to 0.6 ppm and the correlation coefficient were ca. 0.9993. The detection limits (S/N) were from 10 ppb for Nd(III) and Eu(III) to 20 ppb for Sm(III). The relative standard deviations was ${\pm}$.2% for 0.4 ppm sample. The samples throughput was ca. $50\;cm^{-1}$.

  • PDF