• Title/Summary/Keyword: metal balloon

Search Result 17, Processing Time 0.026 seconds

Development of the Micro Metal Balloon Using Sirasu-balloons as a Core Material

  • Uezono, Tsuyoshi;Sodeyama, Ken-ichi;Onomae, Hiroshi;Sakka, Yoshio
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.604-605
    • /
    • 2006
  • Recently the Marangoni convention is supposed to be an important phenomenon that significantly affects the solidification. For understanding the Marangoni convection mechanism, visualizing the convention phenomenon of molten tin with ultrasonic has been conducted. This paper reports developing a tracer material of micro metal balloon that is used in the molten system. We have succeeded in coating the surface of Shirasu-ballons with nickel by plating process. The obtained metal balloon is spherical and some characterizations were conducted.

  • PDF

Identification of Transition Characteristics and Bio-concentration Factors of Heavy Metal (loid)s in the Selected Perennial Root Medicinal Plants

  • Kim, Won-Il;Noh, Hyun Myung;Hong, Chang-Oh;Kim, Da-Young;Kim, Kwon-Rae;Oh, Kyeong-Seok;Moon, Byeong-Churl;Kim, Ji-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.4
    • /
    • pp.251-258
    • /
    • 2017
  • This study was conducted to identify transition characteristics of arsenic (As), cadmium (Cd), and lead (Pb) and to calculate bio-concentration factors (BCF) in the three perennial root medicinal plants, namely Codonopsis lanceolata (Deoduck), Platycodon grandiflorum (Balloon flower) and Panax ginseng (Korean ginseng) grown in major medicinal plant producing districts in Korea. Average BCF values ranged from 0.009~0.029 in As, 0.334~1.453 in Cd, and 0.021~0.023 in Pb in three perennial root medicinal plants. The BCF values increased in the order of ginseng (0.029) > deodeok (0.012) > balloon flower (0.009) for As, balloon flower (1.453) > deodeok (0.685) > ginseng (0.334) for Cd, and ginseng (0.023) > deodeok (0.022) > balloon flower (0.021) for Pb. The BCF values calculated in this study will be useful for predicting the uptake of heavy metal (loid)s. Further study on uptake and accumulation mechanism of toxic metal (loid)s by agricultural products is required to assess the human health risk associated with soil contamination.

Heavy Metal Uptake by Balloon Flower Together with Investigating Soil Properties and Heavy Metal Concentrations in the Cultivated Soils

  • Bae, Jun-Sik;Seo, Byoung-Hwan;Lee, Sin-Woo;Kim, Won-Il;Kim, Kwon-Rae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.3
    • /
    • pp.172-178
    • /
    • 2014
  • Soil properties and heavy metal (HM) concentrations in the field soils where balloon flowers (Platycodon grandiflorum, BF) were cultivated, were investigated together with HM (Cd, Cu, Pb, and Zn) accumulation by the BF roots. Basically, in most soils examined (51-97% among 65 samples), the chemical properties including soil pH, organic matter, available-P, and exchangeable cation contents appeared to be lower than the optimal ranges for balloon flower cultivation. There were no samples exceeding the standard limits for HM in soils. Instead, the total HM concentration levels in soils appeared to be maintained at around background levels for general soil in Korea. This implied that elevated HM accumulation in the soils caused by any possible input sources was unlikely. Even though the BF cultivated soils were not contaminated by HM, it was appeared that substantial amount of Cd was accumulated in BF roots with 1.5% and 35% roots samples exceeding the standard limits legislated for BF root ($0.81mg\;kg^{-1}DW$) and herbal plants ($0.3mg\;kg^{-1}DW$), respectively. This implied that the soil HM standard limits based on the total concentration does not reflect well the metal accumulation by plants and also it is likely that the Cd standard limits for BF and herbal plants is too restrict.

Coating defects in polymer-coated drug-eluting stents

  • Bedair, Tarek M.;Cho, Youngjin;Park, Bang Ju;Joung, Yoon Ki;Han, Dong Keun
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.1 no.3
    • /
    • pp.131-150
    • /
    • 2014
  • Vascular stenting has a great attention as a treatment for coronary arteries diseases as compared with percutaneous balloon angioplasty. In-stent restenosis and thrombosis are side effects resulting from using bare metal stent (BMS). Employing platelet therapy allowed to reduce the rate of thrombosis, however, the rate of restenosis remains a major problem. In 2002, drug-eluting stents (DESs) were introduced as an effort to reduce the restenosis. The commercially available DESs continue to suffer from coating defects that might lead to a series of adverse effects. Most importantly, multiple concerns remain regarding the polymer coating integrity on metal surfaces or the relation of polymer irregularities to longterm adverse events.

Self-Expandable metallic Stent in Benign Tracheobronchial Stenosis (양성기관지 협착증 환자에서 팽창성 금속성 스텐트의 사용경험)

  • Shin, Dong-Ho;Park, Sung-Soo;Lee, Jung-Hee;Jeon, Seok-Chol;Chung, Won-Sang;Kim, Kung-Hun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.4
    • /
    • pp.318-324
    • /
    • 1992
  • Acquired tracheobronchial stenosis has resulted from vehicular accidents, prolonged tracheal intubation, sleeve resection, tuberculosis and sarcodosis. Various modalities of therapy for the relief of such stenosis included surgery, cryotherapy, laser photoresection, and sometimes balloon dilatation. Several recent reports have described the use of self-expandable metal stents for the dilatation of stenotic areas in the tracheobronchial tree. Three patients of benign acquired tracheobronchial stenosis were treated with self-expandable metal stents, who had shown little response to several times of balloon dilatations; One patient had a tracheal stenosis caused by intubation, one a right main bronchial stenosis developed after reconstructive surgery of traumatic bronchial rupture, and the other a left main bronchial stenosis caused by longstanding endobronchial tuberculosis. We found that the using stent in benign acquired tracheobronchial stenosis can be effectively performed with alleviation of clinical symptoms and lung function. And even in longstanding localized stenosis of main bronchus without distal bronchial destruction, lung perfusion also improved.

  • PDF

Comparison on the Error Rates of Calibration Modes in Intervention (인터벤션에서 Calibration Mode에 대한 오차율 비교)

  • Kong, Chang gi;Ryu, Young hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.619-626
    • /
    • 2020
  • This study aimed to identify the error rates in Catheter Calibration Mode, Auto Calibration Mode, and Segment Calibration Mode among many calibration modes as a quantitative evaluation tool used for predicting the diameter and length of balloon or stent in percutaneous intravascular balloon dilatation or stent insertion. Our experiment was conducted with Copper Wire of 2 mm × 80 mm (diameter × length) manufactured elaborately for quantitative evaluation in calibration and Metal Ball of 5, 10, 15, 30, and 40 mm and Acryl Phantom of 25 mm, 50 mm, 75mm, 100 mm, 125 mm, 150mm, 175 mm, and 200 mm. At each height, subtraction images were acquired with a cineangiograph and Stenosis Analysis Tool as a software provided by the equipment company was used for measurement. To evaluate the error rates in Catheter Calibration Mode, Copper Wire was put on each acryl phantom before shooting. Copper Wire of 2 mm in diameter was set as a diameter for catheter, and Copper Wire of 8 mm in length was measured with Multi-segments. As a result, the error rates appeared at 1.13 ~ 5.63%. To evaluate the error rates in Auto Calibration Mode, the height of acryl was entered at each height of acryl phantom and the length of 8 mm Copper Wire was measured with Multi-segments and as a result, the error rates appeared at 0 ~ 0.26%. To evaluate the error rates in Segment Calibration Mode, each metal ball on the floor of table was calibrated and the length of 8 mm Copper Wire on each acryl phantom was measured and the length of 8 mm Copper Wire depending on the changes of acryl phantom height was measured with Mutli-segments and as a result, the error rates appeared at 1.05 ~ 19.04%. And in the experiment on OID changes in Auto Calibration Mode, the height of acryl phantom was fixed at 100mm and OID only changed within the range of 450 mm ~ 600 mm and as a result, the error rates appeared at 0.13 ~ 0.38%. In conclusion, it was found that entering the height values in Auto Calibration Mode, among these Calibration Modes for evaluating quantitative vascular dimensions provided by the software was the calibration method with the least error rates and it is thus considered that for calibration using a metal ball or other objects, putting them in the same height as that of treatment sites before calibrating is the method that can reduce the error rates the most.

Development Study of A Precooled Turbojet Engine for Flight Demonstration

  • Sato, Tetsuya;Taguchi, Hideyuki;Kobayashi, Hiroaiki;Kojima, Takayuki;Fukiba, Katsuyoshi;Masaki, Daisaku;Okai, Keiichi;Fujita, Kazuhisa;Hongoh, Motoyuki;Sawai, Shujiro
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.109-114
    • /
    • 2008
  • This paper presents the development status of a subscale precooled turbojet engine "S-engine" for the hypersonic cruiser and space place. S-engine employs the precooled-cycle using liquid hydrogen as fuel and coolant. It has $23cm{\times}23cm$ of rectangular cross section, 2.6 m of the overall length and about 100 kg of the target weight employing composite materials for a variable-geometry rectangular air-intake and nozzle. The design thrust and specific impulse at sea-level-static(SLS) are 1.2 kN and 2,000 sec respectively. After the system design and component tests, a prototype engine made of metal was manufactured and provided for the system firing test using gaseous hydrogen in March 2007. The core engine performance could be verified in this test. The second firing test using liquid hydrogen was conducted in October 2007. The engine, fuel supplying system and control system for the next flight test were used in this test. We verified the engine start-up sequence, compressor-turbine matching and performance of system and components. A flight test of S-engine is to be conducted by the Balloon-based Operation Vehicle(BOV) at Taiki town in Hokkaido in October 2008. The vehicle is about 5 m in length, 0.55 m in diameter and 500 kg in weight. The vehicle is dropped from an altitude of 40 km by a high-altitude observation balloon. After 40 second free-fall, the vehicle pulls up and S-engine operates for 60 seconds up to Mach 2. High altitude tests of the engine components corresponding to the BOV flight condition are also conducted.

  • PDF

Feasibility of Percutaneous Pancreatic Stent Placement in Postoperative Pancreaticojejunostomy Stenosis

  • Juil Park;Kichang Han;Joon Ho Kwon;Man-Deuk Kim;Jong Yun Won;Sungmo Moon;Gyoung Min Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1241-1248
    • /
    • 2023
  • Objective: To evaluate the role of percutaneous pancreatic stent placement in postoperative pancreaticojejunostomy stenosis (PJS). Materials and Methods: This retrospective single-center study included seven procedures in five patients (four males and one female; median age, 63 years) who underwent percutaneous pancreatic stent placement for postoperative PJS between January 2005 and December 2021. The patients were referred to interventional radiology because of unfavorable anatomy or bowel abnormalities. The pancreatic duct was accessed under ultrasound and/or computed tomography guidance. A stent was placed after balloon dilatation of the PJS. Moreover, plastic stents were placed for the first two procedures, whereas bare-metal stents were used for the remaining five procedures. Technical success was defined as the successful placement of stents for the PJS, meanwhile, clinical success was defined as the normalization of pancreatic enzymes without recurrence of pancreatitis. Results: Pancreatic duct access and stent placement were successfully performed in all patients (technical success rate: 100%). All the procedures initially yielded clinical success. However, recurrence of pancreatitis was observed after two procedures that used plastic stents because of stent migration at 0.3 and 3 months after the procedure. In contrast, no instances of recurrent pancreatitis were noted after metal stent placement for a follow-up duration of 1-36 months. No serious procedure-related adverse events were observed. Conclusion: Percutaneous pancreatic stent placement may be a viable option for patients with postoperative PJS in whom an endoscopic approach is not feasible. Metal stents may be considered over plastic stents for the management of PJS, considering the possible lower stent migration and infeasibility of frequent endoscopic stent exchange due to the altered anatomy.

Use of Drug-eluting Stents Versus Bare-metal Stents in Korea: A Cost-minimization Analysis Using Population Data

  • Suh, Hae Sun;Song, Hyun Jin;Jang, Eun Jin;Kim, Jung-Sun;Choi, Donghoon;Lee, Sang Moo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.46 no.4
    • /
    • pp.201-209
    • /
    • 2013
  • Objectives: The goal of this study was to perform an economic analysis of a primary stenting with drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients with acute myocardial infarction (AMI) admitted through an emergency room (ER) visit in Korea using population-based data. Methods: We employed a cost-minimization method using a decision analytic model with a two-year time period. Model probabilities and costs were obtained from a published systematic review and population-based data from which a retrospective database analysis of the national reimbursement database of Health Insurance Review and Assessment covering 2006 through 2010 was performed. Uncertainty was evaluated using one-way sensitivity analyses and probabilistic sensitivity analyses. Results: Among 513 979 cases with AMI during 2007 and 2008, 24 742 cases underwent stenting procedures and 20 320 patients admitted through an ER visit with primary stenting were identified in the base model. The transition probabilities of DES-to-DES, DES-to-BMS, DES-to-coronary artery bypass graft, and DES-to-balloon were 59.7%, 0.6%, 4.3%, and 35.3%, respectively, among these patients. The average two-year costs of DES and BMS in 2011 Korean won were 11 065 528 won/person and 9 647 647 won/person, respectively. DES resulted in higher costs than BMS by 1 417 882 won/person. The model was highly sensitive to the probability and costs of having no revascularization. Conclusions: Primary stenting with BMS for AMI with an ER visit was shown to be a cost-saving procedure compared with DES in Korea. Caution is needed when applying this finding to patients with a higher level of severity in health status.

Retrievable Nitinol Stent for Treatment of Tuberculous Tracheobronchial Stenosis -A case report- (결핵성 기관-기관지 협착에서 제거형 니티놀 스텐트 삽입요법 -1례-)

  • Chung, Bong-Kyu;Kim, Kwang-Taik;Park, Sung-Min;Sun, Kyung;Kim, Hyoung-Mook;Lee, In-Sung
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.107-111
    • /
    • 2000
  • Although a tracheal stent can be an option for inoperable tracheal stenoses there still are some troublesome side effects including overgranulation from foreign body irritation restenosis and patient's discomfort associated with the procedure. We report a successful case of a retrievable stent made of self-expandable 'shape memory' metal and polyurethane in a 24 year old female patient with respiratory distress and tight stenosis in the trachea and left main bronchus, The stent was inserted following a balloon dilatation and was successfully removed on the 7th days after the procedure. She regained a normal active life without any repiratory symptoms and a follow-up of 8 months showed satisfactory results.

  • PDF