• Title/Summary/Keyword: mesh graft

Search Result 37, Processing Time 0.026 seconds

Modified Anterior Craniofacial Osteotomy Using Partial Nasal Bone Division and Reconstruction in Frontoethmoidal Sinus Meningioma

  • Park, Eon Ju;Kim, Hong Il;Park, Jin Hyung;Yi, Hyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.2
    • /
    • pp.117-121
    • /
    • 2017
  • Typical transcranial approaches are insufficient for adequate visualization and resection of skull base tumors. Different approaches with multiple modifications have been attempted. Here, we describe a new approach for a lesion that is central and hard to treat by conventional craniotomy and successful reconstruction with calvarial bone graft and titanium mesh plate. A 69-year-old female patient presented with recurrent meningioma. The tumor had invaded the frontal lobe, right supraorbital rim, and ethmoidal bone. We performed a modified anterior craniofacial approach that fully exposed the tumor and invaded bone. In consideration of the patient's age and cosmetic result, the tumor and invaded bone was resected and the defect area was reconstructed with titanium mesh and calvarial bone graft. At 6 months postoperative the patient had no complications and was satisfied with the esthetic result. We report this case to demonstrate the successful approach and reconstruction using this technique.

The Experimental Reconstruction of the Trachea with A Heavy Marlex Mesh and Pericardium (Heavy Marlex Mesh 와 심낭편을 이용한 기관재건술의 실험적 연구)

  • 왕영필;이홍균
    • Journal of Chest Surgery
    • /
    • v.10 no.1
    • /
    • pp.7-17
    • /
    • 1977
  • The increasing frequency of post-tracheostomy stenosis parallels the increase in the incidence of tracheostomy. The development of stenosis of trachea following the operation of tracheal tumor or tracheostomy is a very serious complication. The continuing need for an adequate tracheal substitute has not been answered, despite the necessities of excision and reconstruction of the trachea to keep for effective ventilation. Experimental tracheal reconstuction, with a prosthesis of heavy Marlex mesh and pericardium, _ vas performed in twelve dogs. Five to six tracheal ring circumferential defects were created and were bridged with heavy Marlex mesh fashioned into a tube of suitable diameter. Group A: A prepared cylinder of Marlex mesh was anastomosed outside the cut ends of the trachea. Group B: The external surface of the prepared cylinder of Marlex mesh was completely covered with suitably sized patch of pericardium and overlapped all margin of the Marlex mesh by 2 to 3 mm in each direction. Group C: The internal surface of the prepared cylinder of Marlex mesh was covered with suitably sized patch of pericardium and overlapped all margin of the Marlex mesh by 2 to 3 mm in each direction. The results of this exepriment were as follow: 1. In group A and B, the graft was well bridged with new granulation and fibrous tissue, and the lumen of trachea kept good patency for effective ventilation.. The interstices of Marlex became uniformly infiltrated with young well vasculated connective tissue. Epithelization has not yet occurred at 4 weeks in each group, but there were evidences of new growing mucosa at grafted site in 6 weeks. The remainder of the prosthesis was completely covered with glistening epithelium and the underlying fibrous tissue became more matured with little inflammation. These findings were more striking in group B than group A. 2. In group C, the covered pericardium was necrotized with stenosis of the lumen of grafted site due to poor blood supply.

  • PDF

Preliminary Surgical Result of Cervical Spine Reconstruction with a Dynamic Plate and Titanium Mesh Cage

  • Chung, Dae-Yeong;Cho, Dae-Chul;Lee, Sun-Ho;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.2
    • /
    • pp.111-117
    • /
    • 2007
  • Objective : The objective of this study was to validate the effects of a titanium mesh cage and dynamic plating in anterior cervical stabilization after corpectomy. Methods : A retrospective study was performed on 31 consecutive patients, who underwent anterior cervical reconstruction with a titanium mesh cage and dynamic plating, from March 2004 to February 2006. Twenty-four patients had 1-level and 7 had 2-level corpectomies. Ten patients underwent surgery with a cage of 10-mm diameter and 21 with 13-mm diameter. Neurological status and outcomes were assessed according to Odom's criteria. Sagittal angle, coronal angle, settling ratio, sagittal displacement, and cervical lordosis were used to evaluate the radiological outcomes. Results : In overall, 26 [83.9%] of 31 showed excellent or good outcomes. Thirteen percent [4 cases] of the patients developed surgical complications, such as hoarseness, transient dysphagia, or nerve root palsy. Seven [22.6%] patients had reconstruction failure:5 [20.8%] in the 1-level corpectomy group and 2 [28.5%] in the 2-level corpectomy group. Revisions were required in 2 patients with plate pullout due to significant instability. However, none of 5 patients who demonstrated cage displacement or screw pullout, underwent a revision. Radiographs revealed bony consolidation in 96.3% of the patients, including 6 patients with implantation failure during the follow-up period. Conclusion : Based on our preliminary results, the titanium mesh cage and dynamic plating was effective for cervical reconstruction after corpectomy. The anterior cervical reconstruction performed with dynamic plates is considered to reduce stress shielding and greater graft compression that is afforded by the unique plate design.

GUIDED BONE REGENERATION OF CALVARIAL BONE DEFECTS USING BIOABSORBABLE MEMBRANE AND DEMINERALIZED FREEZE DRIED BONE IN RATS (백서에서 흡수성막과 탈회동결건조골을 이용한 두개골결손부의 골재생)

  • Kim, Soo-Min;Yeo, Hwan-Ho;Kim, Su-Gwan;Lim, Sung-Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.4
    • /
    • pp.290-301
    • /
    • 2002
  • The purpose of this study was to evaluate new bone formation and healing process in rat calvarial bone defects using $BioMesh^{(R)}$. membrane and DFDB. Forty eight rats divided equally into 4 groups of 1 control group and 3 experimental groups. Standardized transosseous circular calvarial defects (8 mm in diameter) were made midparietally. In the control group, the defect was only covered with the soft tissue flap. In the experimental group 1, it was filled with DFDB only, in the experimental group 2, it was covered $BioMesh^{(R)}$. membrane only, and in the experimental group 3, it was filled DFDB and covered with membrane. At the postoperative 1, 2, 4, 8 weeks, rats were sacrificed and histologic and histomorphometric analysis were performed. These results were as follows. In histomorphometric analysis, It showed the greatest amount of new bone formation through experimental in the experimental group 3 (P<0.001). The amount of new bone formation at the central portion of the defect was greater in the experimental group 3 than experimental group 2. $BioMesh^{(R)}$. membrane began to resorb at 1 week and resorbed almost completely at 8 weeks after operation. The collapse of membrane into the defect was observed through the experimental periods in the experimental group 2. In the area of collapsed membrane, new bone formation was restricted. These results suggest that maintenance of some space for new bone to grow is required in the use of $BioMesh^{(R)}$. membrane alone in the defect. It is also thought that use of the membrane may promote new bone growth in DFDB graft.

The Efficacy of Titanium Mesh Cage in Tuberculous Spondylitis Treated with Anterior Intervertebral Fusion (척추 결핵의 전방유합술시 Titanium Mesh Cage의 효과)

  • Jeong, Ju-Ho;Lee, Sang-Gu;Yoo, Chan-Jong;Han, Ki-Soo;Kim, Woo-Kyung;Kim, Young-Bo;Park, Cheol-Wan;Lee, Uhn
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.8
    • /
    • pp.998-1003
    • /
    • 2001
  • Objective : The maintenance of the correction of kyphotic deformity is one of the difficult problem in tuberculous spondylitis after anterior debriment and fusion with tricortical bone graft. The goal of this study is to find out the efficacy of titanium mesh cage impacted with autogenous bone chip in tuberculous spondylitis treated with anterior intervertebral fusion. Materials and Method : Twelve patients were treated with anterior intervertebral fusion using titanium mesh cage for tuberculous spondylitis from January 1996 to June 1999. We analized the changes in the correction of kyphotic deformity, changes of ESR and CRP, fusion state and recurrence after anterior intervertebral fusion with titanium mesh cage. Results : Clinical symptoms were improved in all twelve patients without any neurologic complications. The mean kyphotic angle corrected was 7.3 degrees immediately after operation, but the loss of correction of kyphotic angle was 2.2 degrees after 3 months and 2.6 degrees after 6 months. We found that the loss of correction of kyphotic deformity occurred mainly within the first 3 months after surgery. Only one patient, suffered from acute hepatic failure after first operation and had an insufficient anti-tuberculous medication therapy, showed recurrence of tuberculous spondylitis after 6 months. The patient underwent a second operation with posterior fixation procedure with good outcome. The changes of ESR and CRP were not specifically important factor to reveal recurrence of tuberculosis of the spine in our series. Conclusion : The surgical procedure of tuberculous spondylitis using titanium mesh cage with bone chip seems to be an effective procedure to minimize loss of the correction of kyphotic deformity without any aggravating inflammatory change and recurrence with titanium mesh cage, when sufficient debridement and anti-tuberculous chemotherapy are achieved.

  • PDF

Effects of different sizes of Hydroxyapatite/$\beta$-Tricalcium phosphate particles on vertical bone augmentation (수직골 증대술에서 $\beta$-Tricalciumphosphate/Hydroxyapatite 골 이식재 입자 크기의 영향)

  • Huh, Jung-Bo;Jung, Dong-Hee;Kim, Ji-Sun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.259-265
    • /
    • 2010
  • Purpose: This study was aimed to evaluate the effect of different sizes of $\beta$-TCP/ HA particles on vertical bone augmentation using titanium mesh in the cranium of rabbits. Materials and methods: Six white rabbits weighing 5kg were used. Four circular grooves of 6mm diameter were made by trephine, and five small holes were drilled in the inner surface of each circular gooves. Different sizes of grafts (small 0.3 - 0.5 mm, medium 0.5 - 1.0, large 1.0 - 2.0 mm) were placed respectively in the experimental groups. Titanium mesh (height 3 mm, width 6 mm) was placed. After 8weeks healing period, the rabbits were euthanized, and the specimens were prepared for histological findings. New bone formation and remaining graft area were measured to calculate the ratio of areas occupying the inner space of titanium mesh. Mann-Whitney U-test and Wilcoxon signed rank-test were used for statistical analysis ($\alpha$ = .05). Results: The experimental groups with $\beta$-TCP/HA graft showed a significantly higher new bone formation (P = .003). Comparing different sizes of $\beta$-TCP/HA, there was no statistical difference in terms of new bone formation. The vertical bone formation (i.e. new bone and graft area) was significantly greater in $\beta$-TCP/HA groups (P = .001). In comparison between different sizes of $\beta$-TCP/HA, medium size group had significantly greater area than large particle size group (P = .039). Conclusion: The use of $\beta$-TCP/HA with titanium mesh showed a higher vertical bone formation, particularly the medium sized $\beta$-TCP/HA particles (0.5 - 1.0 mm) produced better results in vertical bone augmentation.

Anterior Decompression and Internal Fixation with Anterior Instrument and Surgical Titanium Mesh in Thoracolumbar Unstable Spine Injuries (Long-term Follow-up Results) (흉·요추 불안정성 척추 손상 환자에서 전방 감압술과 전방기기 및 Surgical Titanium Mesh를 이용한 내고정술 (장기적 추적 검사 결과))

  • Park, Hwan Min;Lee, Seung Myung;Cho, Ha Young;Shin, Ho;Jeong, Seong Heon;Song, Jin Kyu;Jang, Seok Jeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.58-65
    • /
    • 2000
  • Objective : Thoracolumbar junction is second most common level of injury next to cervical spine. The object of this study is to study the usefulness of surgical titanium mesh instead of bone graft, as well as to evaluate the correction of spinal deformity and safety of early ambulation in patients with injury at thoracolumbar junction. Patients and Methods : This review included 51 patients who were operated from July 1994 to December 1997. The injured spine is considered to be unstable, if it shows involvement of two or more columns, translatory displacement more than 3.5mm, decrease more than 35% in height of vertebral body and progression of malalignment in serial X-ray. The decision to operate was determined by (1) compression of spinal cord or cauda eguina, (2) unstable fracture, (3) malalignment and (4) fracture dislocation. The procedure consisted of anterior decompression through corpectomy and internal fixation with anterior instrument and surgical titanium mesh which was impacted with gathered bone chip from corpectomy. Results : Fifty-one patients were followed up for at least 12 months. The main causes of injury were fall and vehicle accident. The twelfth thoracic and the first and the second lumbar vertebrae were frequently involved. Complete neural decompression was possible under direct vision in all cases. Kyphotic angulation occurred in a patient. Radiologic evaluation showed correction of deformity and no distortion or loosening of surgical titanium mesh with satisfactory fixation postoperatively. Conclusions : We could obtain neurological improvement, relief of pain, immediate stabilization and early return to normal activities postoperatively. Based on these results, authors recommend anterior decompression and internal fixation with surgical titanium mesh in thoracolumbar unstable spine injuries.

  • PDF

Cryptogenic Temporal Hollowing

  • Park, Ie Hyon;Kwon, Heeyeon;Kim, Sang Wha
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.4
    • /
    • pp.218-221
    • /
    • 2016
  • Temporal hollowing is a common complication that occurs after coronal approach surgeries. However, temporal hollowing without previous nerve damage or trauma history is rare. Herein, we present a patient with cryptogenic temporal hollowing. A 22-year-old man without any history of craniofacial interventions or trauma presented with temporal hallowing. Magnetic resonance imaging revealed fatty degeneration of the left temporalis muscle. Electromyography and nerve conduction study showed no signs of neurologic abnormalities. The patient received autologous fat injection of 30 mL harvested from the left thigh using the modified Coleman technique. Temporal hollowing is commonly caused by atrophy of the superficial temporal fat pad. Its incidence is reported to be as high as 6% after coronal approach operation. Augmentation using porous hydroxyapatite or titanium mesh is a treatment option. Autologous fat graft can also be an option for mild to moderate temporal hollowing. In this case, a patient with no history of trauma, surgery, or myogenic disease developed temporal hollowing. Further study of the little-known cryptogenic form of temporal hollowing is warranted.

A Case of Forearm Muscle Herniation after Radial Forearm Sensory Tendocutaneous Free Flap (요골 전완부 감각신경 유리건피판술 후 생긴 근육탈출증의 증례보고)

  • Lee, Paik Kwon;Kim, Min Cheol;Jun, Young Joon;Oh, Deuk Young;Rhie, Jong Won;Ahn, Sang Tae
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.205-207
    • /
    • 2008
  • Purpose: Although muscle hernia has been well described in the lower-extremity, muscle hernias in the upper extremity are extremely rare. As with lower extremity muscle hernias, the forearm muscle hernia may result from forced exertion of strenuous activity or following blunt trauma. The objective of this paper is to report an extraordinary case of forearm muscle hernia after radial forearm sensory tendocutaneous free flap with references. Methods: A 58-year-old male patient received wide excision and radical neck dissection and lower lip reconstruction with radial forearm sensory tendocutaneous free flap for squamous cell cancer on the lower lip. 16 weeks after the operation, he complained of protruding mass on the forearm and the size was increasing. In postoperative 18 weeks, MRI showed herniation of flexor digitorum superficialis. For unaesthetic cause and preventing progress, the authors performed direct fascial closure and Mesh graft. Results: In 12 months after the surgery there was no recurrence and the patient remained symptom-free. Conclusion: Pain on extremity exertion and unaesthetic buldge of forearm due to forearm muscle hernia were the primary indications for surgery which consist of direct closure, fasciotomy, fascia lata onlay graft, fascia lata inlay graft, etc. The authors experienced uncommon forearm muscle hernia after radial forearm free flap and satisfying result of treatment.

Design and Implementation of 2.5D Mapping System for Cloth Pattern (의복패턴을 위한 2.5D 맵핑 시스템의 설계 및 구현)

  • Kim, Ju-Ri;Joung, Suck-Tae;Jung, Sung-Tae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.4
    • /
    • pp.611-619
    • /
    • 2008
  • 2.5D Mapping system that embody in this paper can make new design by doing draping to live various texture and model picture image of fashion clothes by pattern, and can confirm clothes work to simulation without producing direction sample or product directly. Also, the system can support function that can forecast fabric design and state of end article exactly, and the system can bring competitive power elevation of fashion industry and cost-cutting effect by doing draping using database of fabric and model picture image. 2.5D Mapping system composed and embodied by mesh warp algorithm module, light and shade extraction and application module, mapping path extraction module, mesh creation and transformation module, and 2.5D mapping module for more natural draping. Future work plans to study 3D fashion design system that graft together 3D clothes technology and 3D human body embodiment technology to do based on embodiment technology of 2.5D mapping system and overcomes expression limit of 2.5D mapping technology.