• Title/Summary/Keyword: mercury ions

Search Result 87, Processing Time 0.035 seconds

Pore Size Distribution and Chloride Diffusivity of Concrete Containing Ground Granulated Blast Furnace Slag

  • Moon Han-Young;Kim Hong-Sam;Choi Doo-Sun
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.277-282
    • /
    • 2004
  • In a hardened concrete, diffusion of oxygen, carbon dioxide, aggressive ions, and moisture from the environment to the concrete takes place through the pore network. It is well known that making dense cement matrix enhances the durability of concrete as well as all the characteristics including strength of concrete. In this paper,9 mix concretes with water to cementitious material ratio (40,45, and $50\%$) and replacement ratio of GGBFS (40 and $60\%$ of cement by weight) were studied on the micro-pore structure by mercury intrusion porosimetry and the accelerated chloride diffusion test by potential difference. From the results the average pore diameter and accelerated chloride diffusivity of concrete were ordered NPC > G4C > G6C. It is concluded that there is a good correlation between the average pore diameter and the chloride diffusivity, and the mineral admixtures has a filling effect, which increases the tortuosity of pore and makes large pores finer, on the pore structure of cement matrix due to the latent hydraulic reaction with hydrates of cement.

Determination of measuring time for decision of heavy metal ion concentration in Square Wave Voltammetry with FPGA (FPGA를 이용한 네모파 전압전류법의 계측시간 분석)

  • Lee, Jaechoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.4
    • /
    • pp.25-31
    • /
    • 2016
  • In this research, to analyze the concentration of heavy metal ions in water, we tried to find the measuring time at which the faradaic electric currents flowing by the pure oxidation-reduction reaction from the pushing up mercury electrode of the stripping scan square wave voltammetry(SV+SWV) methods system becomes larger than the capacitance electric current. In order to do this, a method for analyzing signals using FPGA has been designed and we conducted 120 experiments using it. As a result, when the frequency of the square wave is 40Hz, The valid potential-current signal was measured from 96.6667% to 96.7155% of the end of the pulse of the forward and reverse, and the optimal signal was measured at 96.6667%. In addition, the experiment was carried out 40 times by changing the pulse height of the square wave from 10Mv to 40Mv. As a result, at a size smaller than 40Mv, there is little change in the magnitude of the potential-current, and an invalid signal was generated when it is out of this size.

Determination of Silver with Mercaptans (I). Amperometric Titration of Silver with 2,5-Dimercapto-1,3,4-Thiadiazole (Mercapto 화합물에 의한 은의 정량 (제1보) 2,5-Dimercapto-1,3,4-Thiadiazol에 의한 은의 전류 적정)

  • Young Gu Ha;Q. Won Choi
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.2
    • /
    • pp.126-129
    • /
    • 1973
  • An amperometric method has been developed for the titration of silver with 2,5-dimercapto-1,3,4,-thiadiazole in ammonical solution (1N) using rotating platinum electrode as an indicator electrode and the mercury-mercury (II) iodide as reference electrode. Direct titration of milligram amount of silver (0.05-1.0mg) is possible in the presence of a number of foreign ions in ammonical solution containing ethylenediaminetetraacetic acid as masking agent under atmosphere. The interfering elements are gold and platinum. The milligram amount of silver can be determined by the proposed method within an error ${\pm}3{\%}$.

  • PDF

Nanofiber Membrane based Colorimetric Sensor for Mercury (II) Detection: A Review (나노 섬유 멤브레인을 기반으로 한 수은(II) 색변화 검출 센서에 대한 총설)

  • Bhang, Saeyun;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.31 no.4
    • /
    • pp.241-252
    • /
    • 2021
  • Rapid industrialization with growing population leads to environmental water pollution. Demand in generation of clean water from waste water is ever increasing by scarcity of rain water due to change in weather pattern. Colorimetric detection of heavy metal present in clean water is very simple and effective technique. In this review membrane based colorimetric detection of mercury (II) ions are discussed in details. Membrane such as cellulose, polycaprolactone, chitosan, polysulfone etc., are used as support for metal ion detection. Nanofiber based materials have wide range of applications in energy, environment and biomedical research. Membranes made up of nanofiber consist up plenty of functional groups available in the polymer along with large surface area and high porosity. As a result, it is easy for surface modification and grafting of ligand on the fiber surface enhanced nanoparticles attachment.

Study on Optical Characteristics of 8-Hydroxyquinoline Synthesized Derivative as Sensing Material of the Fiber-Optic Copper Ion Sensor in Aqueous Environment (수질환경에서 광섬유 센서의 구리 이온 감지 물질로서 8-Hydroxyquinoline 합성유도체의 광학적 반응 특성 연구)

  • Kim, Beom Kyu;Park, Byung Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.100-105
    • /
    • 2017
  • An 8-hydroxyquinoline compound that was synthesized with 8-hydroxyquinoline-2-carboxaldehyde and 4-aminoantipyrine was investigated for use as the sensing material of a fiber-optic copper ion sensor in an aqueous environment. The experiment was conducted with a fiber-optic measurement system, in order to evaluate the relationship between the absorbance peak and copper ion concentration. The synthesized derivative exhibited a (highly selective) chromogenic phenomenon for copper ions among various metal ions in an aqueous environment and showed a specific absorbance peak at a wavelength of 530 nm for copper ions. The effect of mercury ions was investigated to evaluate the selectivity of the prepared synthesized derivatives toward Cu ions. The absorbance was measured at various concentration ratios of Cu and Hg ions (Cu:Hg ratios from 0.05 to 20), and it was found that the absorbance at 530 nm tended to increase with increasing Cu ion concentration. The experimental results also showed the linear relationship between the logarithmic concentration of copper ions and the specific absorbance peak at a wavelength of 530 nm. These results indicate that the synthesized 8-hydroxyquinoline compound has selectivity for copper ions and can be used as a sensing material for fiber-optic copper ion sensors.

X-ray and Spectroscopy Studies of Mercury (II) and Silver (I) Complexes of α-Ketostabilized Phosphorus Ylides (α-케토안정화된 일리드화 인의 수은(II) 및 은(I) 착물에 대한 X-선 및 분광학적 연구)

  • Karami, K.;Buyukgungor, O.;Dalvand, H.
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.1
    • /
    • pp.38-45
    • /
    • 2011
  • The complexation behavior of the $\alpha$-ketostabilized phosphorus ylides $Ph_3P$=CHC(O) $C_6H_4-X$ (X=Br, Ph) towards the transition metal ions mercury (II) and Silver (I) was investigated. The mercury(II) complex {$HgX_2$ [Y]} 2 ($Y_1$=4-bromo benzoyl methylene triphenyl phosphorane; X=Cl(1), Br(2), I(3), $Y_2$=4-phenyl benzoyl methylene triphenyl phosphorane; X=Cl(4), Br(5), I(6)) have been prepared from the reaction of $Y_1$ and $Y_2$ with $HgX_2$ (X=Cl, Br, I) respectively. Silver complexes [$Ag(Y_2)_2]$ X(X=$BF_4$(7), OTf(8)) of the $\alpha$-keto-stabilized phosphorus ylides ($Y_2$) were obtained by reacting this ylide with AgX (X=$BF_4$, OTf) in $Me_2CO$. The crystal structure of complexes (1) and (4) was discussed. These reactions led to binuclear complexes C-coordination of ylide and trans-like structure of complexes $[Y_1HgCl_2]_2$. $CHCl_3$ (1) and $[Y_2HgCl_2]_2$ (4) is demonstrated by single crystal X-ray analyses. Not only all of complexes have been studied by IR, $^1H$ and $^{31}P$ NMR spectroscopy, but also complexes 1-3 have been characterized by $^{13}$CNMR.

Hg(II) ion- Selective Electrodes with Neutral Carriers of Macrocycles (거대고리 중성 운반체를 갖는 Hg(II)이온 선택성 전극)

  • 정오진
    • Journal of Environmental Science International
    • /
    • v.5 no.2
    • /
    • pp.211-220
    • /
    • 1996
  • New thin-and diselena-crown ethers containing two suffer and selenium donor atoms have been prepared. And then, mercury ($Hg^{2+}$) ion-selective electrodes with PVC-plasticizer (STPB) based on some macrocycles as neutral carriers were also made. The electrochemical selectivities for various ions, and the effects for macrocycles, matrix of membranes, ratio of plasticizer to macrowcles, concentration and pH of test solution were investigated on the $Hg^{2+}$ ion-selective electrodes. The 1, 10-diselena-18-crown-6-PVC-STPB (sodium tetraphenylborate) exhibited good linear responses of ${28.2}\pm{0.6}$ decade-1 for $Hg^{2+}$ ion in the conientration ranges of $10^{-2}~10^{-6}$ M $Hg^{2+}$ ion. This electrode exhibited comparatively good selectivities for $Hg^{2+}$ ion in comparison with alkali and alkaline earth metal ions, some heavy metal ions and rare earth metal ion in the range of pH 2.5~6.0. In addition, this electrode was applied as a sensor in the titration of $Hg^{2+}$ ion with $1^-$ ion in water.

  • PDF

Effect of High Pressure on Polarographic Parameters of Metal Ions (金屬이온의 폴라로그래프法的 파라미터에 미치는 壓力의 影響)

  • Heung Laek Lee;Zun Ung Bae;Jong Hoon Yun
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.315-322
    • /
    • 1984
  • The dependence of polarographic parameters on the pressure for the reduction of In(III), Cr(III), Cd(II), Pb(II), Mn(II), Co(II), Tl(I) in 0.1M KCl aqueous solution at the dropping mercury electrode have been discussed. In this experiment the temperature varied from $25^{\circ}C\;to\;35^{\circ}C$ and the pressure ranges from 1 atmosphere to 1,800 atmospheres. By increasing the pressure the reduction half-wave potentials of all metal ions are shifted markedly to more negative values and the diffusion currents of all metal ions become considerably larger. The slope of the linear relationship of E vs. log[$\frac{id-i)}{i}$] become much larger with increase in pressure, which indicates more irreversible reduction. The temperature coefficient observed over the range of the temperature from $25^{\circ}C\;to\;35^{\circ}C$ are not sensitive with increase in pressure.

  • PDF

A Study on the Permeabilities of Concretes Containing Silica Fume (실리카 흄을 혼입한 콘크리트의 투과특성에 관한 연구)

  • 형원길;장효식;소형석;소승영;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.443-448
    • /
    • 1999
  • Tests have been carried out on four concrete containing different levels of silica fume to measure their permeability coefficient using water and oxygen, chloride ion. The total cementitious content was 351kg/㎥, and the water/cementitious materials ratio was 0.55. The results show that a dramatic reduction in permeability of concrete containing silica fume occurs due to formation of a discontinuous macro-pore system which inhibits flow. Porosity estimates from mercury-intrusion porosimetry are used to develop an explanations for the water and air permeability reduction. And, results of the rapid permeability test showed that the resistance of concrete to the penetration of chloride ions increases significantly as a contents of silica-fume is increased. The current intensity passing through the concrete containing silica fume is presented from 664C to 2166C.

  • PDF

METALLOTHIONEIN GENE EXPRESSION BY CADMIUM IN CRUCIAN CARP (CARASSIUS AURATUS)

  • Nam, Seong-Sook;Heekyung Bae;Kim, Eunkyoung;Moon, Chang-Kiu;Jeon, Seong-Hwan;Na, Jin-Gyun;Park, Kwangsik
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2002.05a
    • /
    • pp.127-127
    • /
    • 2002
  • Methallothioneins(MTs) are low-molecular-mass cysteine-rich metal-binding proteins with high affinity for heavy metal ions, found in a large variety of organisms. Although the biological functions of MTS have not been fully elucidated, they are thought to play an important role in detoxification of toxic elements such as cadmium and mercury.(omitted)

  • PDF